The TeSys range provides more simplicity, compactness, openness and exibility ... so many evolutions and new items to aid your productivity. Accurate and reliable control of motors
Increase your productivity, adopt our solutions which help to simplify setting-up.
Motor starters p Ready-to-use component combinations, designed to work together in perfect harmony. p Safe operation and level of coordination guaranteed by a major manufacturer. Power circuit control p A wide range of components. p Solutions for a variety of power control applications: lighting, capacitor switching, heating, changeover contactor pairs, resistive loads, upstream protection.
Contents
Motor control components
New
TeSys contactors .................................................................... 2 to 11 p Contactors, TeSys K, D, F, B p Variable composition contactors, TeSys CV TeSys protection components ........................................... 12 to 33 p Thermal-magnetic circuit-breakers p Magnetic circuit-breakers p Fuse carriers, switch-disconnector-fuses p Thermal overload relays p Electronic thermal overload relays p Electronic overload relays p Starter-controller, TeSys T p Multifunction protection relays p Switch disconnectors Mini Vario and Vario TeSys starters ..................................................................... 34 to 41 p Combination motor starters p Starter-controller, TeSys U p Controller, TeSys U p Enclosed motor starters TeSys installation system ................................................... 42 to 43 p For motor starter components with spring terminals, TeSys Quickt technology
The new TeSys GV3 circuit-breakers, LC1D 40/50/65 contactors, LRD3 thermal relays are equipped with the new terminal block:
EverLink
Long lasting connection quality. Schneider Electric patented technology.
TeSys protected
TeSys T is an advanced motor management and protection system. It is able to guard against all motor malfunctions: overland, current peak, excessive consumption, etc.
With open communication across CANopen, Probus DP, Modbus, AS-Interface, Modicon STB, DeviceNet and Ethernet networks, TeSys U has openness in mind.
TeSys K
Contactors
0.065.5 kW
Connections
N screw clamp terminals Rated operational current Rated operational power in category AC3 Contactor type (1)* Reversing contactor type * with mechanical interlock b spring terminals Add the gure 3 before the voltage code. Example: LC1K0610 becomes LC1K06103 b Faston connectors, 1 x 6.35 or 2 x 2.8 Add the gure 7 before the voltage code. Example: LC1K0610 becomes LC1K06107 b solder pins for printed circuit boards Add the gure 5 before the voltage code. Example: LC1K0610 becomes LC1K06105 (1) Basic reference, to be completed by adding 01 for NC auxiliary contact, or 10 for NO auxiliary contact. * Basic reference to be completed by adding the coil voltage code Ie max AC-3 (Ue 440 V) Ie AC-1 ( 40 C) 220/240 V 380/400 V415/440 V 660/690 V500 V a c a c 6A 1.5 kW 2.2 kW 3 kW LC1K06 LP1K06 or LP4K06 LC2K06 LP2K06 or LP5K06 9A 20 A 2.2 kW 4 kW 4 kW LC1K09 LP1K09 or LP4K09 LC2K09 LP2K09 or LP5K09 12 A 3 kW 5.5 kW 4 kW LC1K12 LP1K12 or LP4K12 LC2K12 LP2K12 or LP5K12
Coil with integral suppression device available, add 3 to the code required. Example: JD3 Low consumption Contactors LP4K (0.71.30 Uc), coil suppression as standard Volts Code 12 JW3 20 ZW3 24 BW3 48 EW3 72 SW3 110 FW3 120 GW3
Composition Reference
N electronic time delay
2NO LA1KN20
2NC
4NO LA1KN40
4NC
LA1KN02
LA1KN04
Relay outputs, with common point changeover contact, a or c 2448, 2 A maximum Control voltage 0.851.1 Uc Maximum switching capacity 250 VA or 150 W Operating temperature -10+ 60C Reset time: 1.5 s during the time delay period, 0.5 s after time delay period Type Timing range Composition Voltage Reference On-delay 130 s 1 a or c 2448 V LA2KT2E a 110240 LA2KT2U
Suppressor modules
For LC1, LP1-K Type Voltage Reference Varistor (a and c) 1224 V LA4KE1B 3248 V LA4KE1E 50129 V LA4KE1FC 130250 V LA4KE1UG Diode (c) + Zener 1224 V LA4KC1B 3248 V LA4KC1E RC (a) 220250 V LA4KA1U
TeSys D
Contactors
0.0675 kW
Connections
screw clamp terminals or connectors
Rated operational voltage Rated operational current Rated operational power in category AC3 Ie max AC-3 (Ue 440 V) Ie AC-1 ( 60 C) 220/240 V 380/400 V 415/440 V 500 V 660/690 V 1000 V Contactor type * Reversing contactor type * with mechanical interlock
N spring terminals (1)
690 V 9A 25 A 2.2 kW 4 kW 4 kW 5.5 kW 5.5 kW LC1D09 LC2D09 3 kW 5.5 kW 5.5 kW 7.5 kW 7.5 kW LC1D12 LC2D12 12 A 18 A 32 A 4 kW 7.5 kW 9 kW 10 kW 10 kW LC1D18 LC2D18 25 A 40 A 5.5 kW 11 kW 11 kW 15 kW 15 kW LC1D25 LC2D25 32 A 50 A 7.5 kW 15 kW 15 kW 18.5 kW 18.5 kW LC1D32 LC2D32 9 kW 18.5 kW 18.5 kW 18.5 kW 18.5 kW LC1D38 LC2D38 38 A
Add the gure 3 before the voltage code. Example: LC1D09P7 becomes LC1-093P7
N lug-clamps (2)
Add the gure 6 before the voltage code. Example: LC1D09P7 becomes LC1-096P7
N Faston connectors (3) 2 x 6.35 (power) and 1 x 6.35 (control) up to D12 only
Add the gure 9 before the voltage code. Example: LC1D09P7 becomes LC1-099P7 * Basic reference to be completed by adding the coil voltage code
(1)
(2)
(3)
24 B7 B5 B6 12 JD JD JW -
42 D7 D5 24 BD BD BW BD
48 E7 E5 E6 36 CD CD CW -
110 F7 F5 F6 48 ED ED EW ED
220 M7 M5 M6 72 SD SD SW SD
230 P7 P5 110 FD FD FW FD
240 U7 U5 U6 125 GD GD GD
380 Q7 Q5 Q6 220 MD MD MW MD
400 V7 V5 250 UD UD UD
415 N7 N5 440 RD RD RD
440 R7 R5 R6
500 S7 S5 -
Contactors LC1D09D150 (coils D115 and D150 with integral suppression device tted as standard)
Contactors LC1D115 and D150 (coils with integral suppression device tted as standard)
5 AL
12 JL
20 ZL
24 BL
48 EL
110 FL
120 ML
250 UL
1000 V on a supply, 690 V on c supply 80 A 125 A 22 kW 37 kW 45 kW 55 kW 45 kW 45 kW LC1D80 LC2D80 25 kW 45 kW 45 kW 55 kW 45 kW 45 kW LC1D95 LC2D95 95 A 115 A 200 A 30 kW 55 kW 59 kW 75 kW 80 kW 75 kW LC1D115 LC2D115 40 kW 75 kW 80 kW 90 kW 100 kW 90 kW LC1D150 LC2D150 150 A
Set of connections LAD-9R1V LA9D8069 LA9D8069 LA9D11569 LA99R1 LAD9R3 LA9D8069 LA9D8069
Mechanical interlock included LA9D4002 LA9D8002 LA9D11502 included included LA9D50978 LA9D80978
LC1-D09D38
N with integral electrical interlocking
LC1-D80 and D95 (a) LC1-D80 and D95 (c) LC1-D115 and D150
N without electrical interlocking
LC1-D09D38 LC1-D40AD65A LC1-D80 and D95 (a) LC1-D80 and D95 (c)
TeSys D
Contactors
Auxiliary contacts
Contact type
Block mounting References Contact 1 NO 1 NC 1 NO + 1 NC 2 NO 2 NC 2 NO + 2 NC 1 NO + 3 NC 3 NO + 1 NC 4 NO 4 NC
Contact type
Block mounting Temporisation References On-delay Off-delay
Time delay
Front mounting or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1
TeSys D
Contactors
Suppressor modules
Type of module
Mounting For use with contactor References Voltage 2448 VAC 50127 VAC 110240 VAC 380415 VAC
RC circuits (Resistor-Capacitor)
Side clip-on D09D38(3P) DT20DT40(4P) LAD4RCE LAD4RCG LAD4RCU Front clip-on LAD4RC3E LAD4RC3G LAD4RC3U LAD4RC3N Screw xing LA4DA2E LA4DA2G LA4DA2U LA4DA2N
Type of module
Mounting For use with contactor References Voltage 2448 VAC 50127 VAC 110240 VAC 2448 VDC 50127 VDC 110240 VDC
Type of module
Mounting For use with contactor References Voltage 24250 VDC
Flywheel diodes
Side clip-on D09D38(3P) DT20DT40(4P) LAD4DDL Front clip-on LAD4D3U Screw xing LAD4DC3U
Type of module
Mounting For use with contactor References Voltage 24 VAC 24 VDC 72 VAC 72 VDC 125 VDC 250 VDC 600 VDC
TeSys F
Contactors
90450 kW
Rated operational current Rated operational voltage Number of poles Rated operational power in category AC3
225 A 315 V 1 000 V 3 or 4 63 kW 110 kW 110 kW 110 kW 129 kW 129 kW 100 kW LC1F225 LC2F225
265 A 350 A 1 000 V 3 or 4 75 kW 132 kW 140 kW 140 kW 160 kW 160 kW 147 kW LC1F265 LC2F265
330 A 400 A 1 000 V 3 or 4 100 kW 160 kW 180 kW 200 kW 200 kW 220 kW 160 kW LC1F330
Contactor type* Reversing contactor type* * Basic reference to be completed by adding the coil voltage code
400 A 500 A 1 000 V 2, 3 or 4 110 kW 200 kW 220 kW 250 kW 257 kW 280 kW 185 kW LC1F400
500 A 700 A 1 000 V 2, 3 or 4 147 kW 250 kW 280 kW 295 kW 355 kW 335 kW 335 kW LC1F500 For customer assembly
630 A 1 000 A 1 000 V 2, 3 or 4 200 kW 335 kW 375 kW 400 kW 400 kW 450 kW 450 kW LC1F630
780 A 1 600 A 1 000 V 3 or 4 220 kW 400 kW 425 kW 425 kW 450 kW 475 kW 450 kW LC1F780
800 A 1 000 A 1 000 V 3 250 kW 450 kW 450 kW 450 kW 450 kW 475 kW 450 kW LC1F800
dust & damp protected contacts Composition NO NC 1 2 1 2 Reference LADN11 LADN20 LADN02 Composition NO NC 2 1 4 3 2 2 3 4 1 2 LADN22 LADN13 LADN40 LADN04 LADN31 LADC22 Reference Composition NO NC 2 2 2 2 2 2 1 1 LA1DX20 LA1DY20 LA1DZ40 LA1DZ31 Reference
N time delay 1 NO + 1 NC
Type On-delay
Off-delay
TeSys B
Contactors
400900 kW
Rated operational current Rated operational voltage Number of poles Rated operational power in category AC3
1000 A 1250 V 1 000 V 1 to 4 280 kW 500 kW 530 kW 560 kW 600 kW 670 kW 530 kW
1500 A 2000 A 1 000 V 1 to 4 425 kW 750 kW 800 kW 800 kW 700 kW 750 kW 670 kW
1800 A 2750 A 1 000 V 1 to 4 500 kW 900 kW 900 kW 900 kW 900 kW 900 kW 750 kW
4 instantaneous contact congurations 2 NC + 2 NO, 3 NO + 1 NC, 1 NO + 3 NC or 4 NO Contactor type* LC1BL LC1BM LC1BP LC1BR * Basic reference to be completed by adding the coil voltage code, followed by the instantaneous contact conguration.
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts 48 110 125 127 220 a 50400 Hz c ED F FD GD G M MD
230 P -
240 U -
380 Q -
400 V -
415 N -
440 R RD
500 S -
Example: To order a 1500 A contactor with 127 V c coil with 3 NO + 1 NC, select LC1BP33G31
Mounting accessories
Description Bar support bracket for mounting on 120 or 150 mm centres Mechanical interlock and locking device components LC1B EZ2LB0601 For contactor LC1BL to BR Reference LA9B103
10
TeSys
CV1-B, CV3-B
Reference to compiled by the customer
Contactor type, according to required use a supply 690 V, c supply 220 V/pole a supply 1000 V, c supply 440 V/pole Contactor rating CV1: 80 A CV1: 200 A CV1: 300 A CV1: 470 A CV1: 630 A CV1: 1000 A Number of poles (PN1 main poles for CV1 and PA3 main poles for CV3) Normally Open main poles 1 NO 2 NO 3 NO 4 NO 5 NO Normally Closed main poles 1 NC 2 NC 3 NC No main poles Operational current 10 A 20 A 40 A 80 A 125 A 170 A 200 A 250 A 300 A 320 A 470 A 500 A 630 A 1000 A Control circuit voltage 48 V 110 V 120 V 208 V 220 V 230 V 240 V 380 V 400 V 440 V Operating frequency 50 Hz 60 Hz 50/60 Hz c c + economy resistor Instantaneous auxiliary contacts Normally Open 1 NO 2 NO 3 NO 4 NO Normally Closed 1 NC 2 NC 3 NC 4 NC Without instantaneous contact On-delay Off-delay 1 CO 1 CO CV3: 80 A CV3: 170 A CV3: 250 A CV3: 320 A CV3: 500 A
CV1B CV3B F G H J K L 1 2 3 4 5 1 2 3 0 Z E N P F R W G S H T J V K L 0 Z E N P F R W G S H T J V K L E F K L M P U Q V R 5 6 7 D R 1 2 3 4 1 2 3 4 0 0 J N
Example 1/ for single-phase capacitor switching: 400 V - 80 A - 1 NO pole - Control circuit 220 V / 50 Hz, 1 NO and 1 NC auxiliary contacts: CV1BF1F0ZM511. 2/ for heating circuits, d.c. supply 800 V - 150 A - 2 NO poles - Control circuit 48 V c , 1 NO + 1 NO On-delay auxiliary contacts: CV3BG2W0ZED10J
Other versions: please consult our Customer Care Centre.
11
TeSys
GV2-ME, GV2-P
Thermal-magnetic circuit-breakers
0.0615 kW
Thermal-magnetic circuit-breakers GV2-ME and GV2-P for connection by screw clamp terminals
GV2-ME with pushbutton control, GV2-P control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.75 1.1 1.1 1.5 1.5 2.2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 H > 100 kA (1) as % of Icu (2) combined with a recommended contactor Icu kA ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( 15 ( 15 50 15 50 15 50 10 50 ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( 50 ( 50 50 40 50 40 50 50 50 Ics (1) 500 V P kW 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 Icu kA ( ( ( ( ( ( ( ( ( 50 ( 10 50 10 50 6 42 6 10 4 10 4 10 4 10 ( ( ( ( ( ( ( ( ( 100 ( 100 100 100 100 75 75 75 75 75 75 75 75 75 75 Ics (1) 690 V P kW 0.37 0.55 0.75 1.1 1.5 1.5 2.2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 22 22 Icu kA ( ( ( ( 3 8 3 8 3 3 3 6 3 6 3 6 3 6 3 6 3 4 3 4 3 4 ( (( ( 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 Ics (1) Setting range of thermal trips A 0.10.16 0.160.25 0.250.40 0.400.63 0.400.63 0.631 11.6 11.6 11.6 1.62.5 1.62.5 2.54 2.54 2.54 2.54 46.3 46.3 610 610 610 610 914 914 914 914 1318 1318 1723 1723 2025 2025 2432 2432 Magnetic tripping current A (d 20%) 1.5 2.4 5 8 8 13 22.5 22.5 22.5 33.5 33.5 51 51 51 51 78 78 138 138 138 138 170 170 170 170 223 223 327 327 327 327 416 416 GV2ME32 GV2P32 GV2ME22 (2) GV2P22 GV2ME21 GV2P21 GV2ME20 GV2P20 GV2ME16 GV2P16 GV2ME16 GV2P16 GV2ME14 GV2P14 GV2ME14 GV2P14 GV2ME10 GV2P10 GV2ME08 GV2P08 GV2ME08 GV2P08 GV2ME01 GV2ME02 GV2ME03 GV2ME04 GV2ME04 GV2ME05 GV2ME06 GV2ME06 GV2ME06 GV2ME07 GV2P07 GV2P01 GV2P02 GV2P03 GV2P04 GV2P04 GV2P05 GV2P06 GV2P06 GV2P06 Reference
12
TeSys
GV2-L, GV2-LE
Magnetic circuit-breakers
0.06 to 15 kW
Magnetic circuit-breakers GV2-LE and GV2-L for connection by screw clamp terminals
GV2-LE control by rocker lever, GV2-L control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.75 1.1 1.5 1.5 2.2 2.2 3 3 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 Icu kA ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( 15 50 15 50 15 50 15 50 10 50 ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( ( 50 50 50 50 40 50 40 50 50 50 Ics (1) 500 V P kW 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 3 3 4 4 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 Icu kA ( ( ( ( ( ( ( ( 50 ( 10 10 10 6 10 6 10 4 10 4 10 4 10 ( ( ( ( ( ( ( ( 100 ( 100 100 100 75 75 75 75 75 75 75 75 75 75 Ics (1) 690 V P kW 0.37 0.55 0.75 1.1 1.5 1.5 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 22 22 Icu kA ( ( ( ( 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 ( ( ( ( 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 Ics (1) Magnetic protection rating A 0.4 0.4 0.63 0.63 1 1 1 1 1.6 1.6 2.5 2.5 2.5 4 4 4 6.3 6.3 10 10 10 10 10 14 14 14 14 18 18 25 25 25 25 32 32 Tripping current d 20% A 5 5 8 8 13 13 13 13 22.5 22.5 33.5 33.5 33.5 51 51 51 78 78 138 138 138 138 138 170 170 170 170 223 223 327 327 327 327 416 416 LR2K0302 LR2K0304 or LRD03 LR2K0304 or LRD04 LR2K0305 or LRD04 LR2K0305 or LRD05 LR2K0306 or LRD05 LR2K0306 or LRD06 LR2K0306 or LRD05 LR2K0307 or LRD06 LR2K0307 or LRD06 LR2K0308 LRD07 LR2K0308 or LRD08 LR2K0310 LRD08 LR2K0312 or LRD08 LR2K0312 LRD10 LR2K0314 LRD12 LR2K0316 or LRD14 LRD14 LRD14 LRD16 LRD16 LR2K0321 LRD16 LRD21 LRD21 LRD22 LRD22 LRD22 LRD22 LRD32 LRD32 GV2LE03 GV2LE03 GV2L03 GV2LE04 GV2L04 GV2LE04 GV2L04 GV2LE05 GV2L05 GV2LE05 GV2L05 GV2LE05 GV2L05 GV2LE05 GV2L05 GV2LE06 GV2L06 GV2LE06 GV2L06 GV2LE07 GV2L07 GV2LE08 GV2L08 GV2LE08 GV2L08 GV2LE08 GV2L08 GV2LE10 GV2L10 GV2LE14 GV2L14 GV2LE14 GV2L14 GV2LE14 GV2L14 GV2LE16 GV2L16 GV2LE16 GV2L16 GV2LE20 GV2L20 GV2LE22 GV2L22 GV2LE22 GV2L22 GV2LE32 GV2L32 Use in association with thermal overload relay Reference
H > 100 kA (1) as % of Icu Common accessories GV2 / GV3, see page 5/15
Other versions: please consult our Customer Care Centre.
13
TeSys
GV3-P/GV3-L
Circuit-breakers
Thermal-magnetic 5.530 kW with EverLink terminal blocks
30 50 (1) as % of lcu
Accessories
Type
Cover
IP20 for lug type terminals IP20 for lug type terminals when used with contactor Wide spacing UL 508 type E
Busbars
Set of 3-pole 115 A busbars for 2 circuit-breakers GV3G264 Set of 3-pole 115 A busbars for 3 circuit-breakers GV3G364 S form for side by side mounted circuit-breaker/ contactor GV3G66 GV3S
References (3) Common add-on blocks and accessories GV2 / GV3, see page 5/15
LAD96570
LAD96575
(4) For spring terminal version add 3 to the end of the reference. Example: GV-AED011 becomes GV-AED0113
Other versions: please consult our Customer Care Centre.
14
TeSys
GV2/GV3
Circuit-breakers
Accessories
GV2-P
GV2APN01 GV2APN02 GV2APN04
GV3-P
GV3APN01 GV3APN02 GV3APN04
NO + NC GVAE11 GVAN11
NO + NO GVAE20 GVAN20
(fault) + NC
(fault) + NO
CO common point
GVAE1
NO (fault) NC (fault)
GVAD1001 GVAD0101
GVA115 GVA125
GVA116 GVA115
15
TeSys
GV7-R
Thermal-magnetic circuit-breakers
0.7590 kW
16
Add-on blocks
Contact blocks Auxiliary contacts Contact type Thermal or magnetic fault discrimination z 2448 V or c 2472 V GV7AD111 Electric trips Voltage Undervoltage trip (1) Shunt trip (1) (1) For mounting of a GV7-AD or a GV7-AU or AS 50/60 Hz 50 Hz GV7AU055 GV7AS055 GV7AU107 GV7AS107 GV7AU207 GV7AS207 GV7AU387 GV7AS387 48 V 110 130 V 200 240 V 380440 V 525 V GV7AU525 GV7AS525 z 110240 V GV7AD112 CO GV7AE11
Accessories
Terminal shields IP 405 Supplied with sealing accessory Phase barriers Safety accessories used when tting of shields is impossible Insulating screens Ensure insulation between the connections and the backplate Kit for combination with contactor Allowing link between the circuit-breaker and the contactor Rotary handles Handle Legend plate
N direct N extended
GV7AC01 GV7AC04
GV7AC05
IP 40 IP 55 IP 43
Conversion accessory for mounting on enclosure door Locking device For circuit-breaker not tted with a rotary handle
17
TeSys
GV3-ME
Thermal-magnetic circuit-breakers
37 kW
(1) as % of Icu
18
TeSys
GK3-EF
Magnetic circuit-breakers
37 kW
19
TeSys DF
Fuse carriers
0125 A
Type
Rated insulation voltage (Ui) Fuse size Conventional thermal current (Ith) References Number of poles 1P N 1P+N 2P 3P 3P+N
Type
Rated insulation voltage (Ui) Fuse size Conventional thermal current (Ith) References Number of poles 1P 1P + N 2P 3P 3P + N
Accessories
Type
Fuse carrier to be equipped Fuse size Number of poles Number of contacts References
Type
Fuse carrier to be assembled Fuse size Kit contents References
20
TeSys
LS1, GK1
Fuse carriers
0125 A
Type
Rated insulation voltage (Ui) Rating Fuse size Connection Single-phase protection device Number of early break contacts Reference Number of early break contacts Reference
Type
Rated insulation voltage (Ui) Rating Fuse size Connection Single-phase protection device Number of early break contacts Reference Number of early break contacts Reference
21
TeSys
LS1, GK1
Fuse carriers
Accessories
Type
Fuse carrier rating For use with fuse carrier Contact type References
Type
Fuse carrier rating For mounting on References
Type
Fuse carrier rating For mounting on References
Type
Fuse carrier rating Number of poles Single-phase protection device References
Padlocking devices
32 A 3 or 4 Without Integrated 50 A 3 Without GK1AV07 With GK1AV08 4 Without GK1AV08 With GK1AV09
Type
Fuse carrier rating References
Tubular link
32 A DK1CB92 50 A DK1EB92 125 A DK1FA9
22
TeSys GS
Switch-disconnector-fuses
Handles
Type
Switch rating References Black/grey Red/yellow
(1) For external front operators with Test facility, insert the letter T in the reference. Example: GS2AH510 becomes GS2AHT510
Type
Switch rating References Black/grey Red/yellow
(2) For external LH side-mounted operators, replace the number 2 in the reference by 3. Example: GS2AH210 becomes GS2AH310
Type
Switch rating References Length of shaft 200 mm 320 mm 400 mm
Type
Switch rating Type of operator References
23
TeSys GS
Switch-disconnector-fuses
321250 A
Type
Rated insulation voltage (Ui) Conventional thermal current (Ith) Fuse size External front-mounted and RH side-mounted operator External LH side-mounted operator Direct RH side-mounted operator (1) Compact fuse for German market (2) 3-pole + switched neutral (3) Direct front-mounted operator 3-pole 4-pole 3-pole 4-pole 3-pole 4-pole
Switch-disconnector-fuse switch bodies for use with NF C or DIN fuses Handle to be ordered separately (see previous page)
690 V 32 A 10 x 38 GS1DD3 GS1DD4 (2) GS1DD3 GS1DD4 (2) GS1DD3 (3) GS1DD4 (2) (3) 50 A 14 x 51 GS2F3 GS2F4 GS2FG3 GS2FG4 GS1FD3 GS1FD4 63 A Size 00C (1) GS2G3 GS2G4 GS2GG3 GS2GG4 GS1GD3 GS1GD4 100 A 22 x 58 GS2J3 GS2J4 GS2JG3 GS2JG4 GS1JD3 GS1JD4
Type
Rated insulation voltage (Ui) Conventional thermal current (Ith) Fuse size External front-mounted and RH side-mounted operator 3-pole 4-pole
Switch-disconnector-fuse switch bodies for use with BS fuses Handle to be ordered separately (see previous page)
690 V 32 A A1 GS1DDB3 GS1DDB4 (2) 32 A A1 GS2DB3 GS2DB4 63 A A2-A3 GS2GB3 GS2GB4 100 A A4 ( 31 mm) GS2JB3 GS2JB4
Accessories
Type
Switch rating Number of contacts Operator external front-mounted or RH side-mounted external LH side-mounted direct RH side-mounted direct front-mounted
Auxiliary contacts
Early break and/or O, I and Test signalling O and I signalling
321250 A 1 NO GS1AM110 GS1AM110 1 NC GS1AM101 GS1AM101 501250 A 1 NO + NC GS1AN11 GS1AN11G GS1AN11 2 NO + 2 NC GS1AN22 GS1AN22G GS1AN22
Type
Number of contacts Switch rating Fuse size References 3-pole 4-pole
Auxiliary blown fuse signalling contacts for use with NF C and DIN fuses
1 NO/NC 50 A 14 x 51 GS1AF1 GS1AF1 100 and 125 A 22 x 58 GS1AF23 GS1AF24 160 A Size 0 GS1AF33 GS1AF34 250 and 400 A Size 1 and Size 2 GS1AF43 GS1AF44
24
125 A 22 x 58 GS2K3 GS2K4 GS2KG3 GS2KG4 GS1KD3 GS1KD4 Size 00 GS2KK3 GS2KK4 GS2KKG3 GS2KKG4 GS1KKD3 GS1KKD4
160 A Size 00 GS2LL3 GS2LL4 GS2LLG3 GS2LLG4 GS1LLD3 GS1LLD4 Size 0 GS2L3 GS2L4 GS2LG3 GS2LG4 GS1LD3 GS1LD4
630 A Size 3 GS2S3 GS2S4 GS2SG3 GS2SG4 GS2S3 (3) GS2S4 (3)
1250 A Size 4 GS2V3 GS2V4 GS2VG3 GS2VG4 GS2V3 (3) GS2V4 (3)
2nd NO/NC 630 A Size 3 GS2AF63 GS2AF64 1250 A Size 4 GS2AF73 GS2AF74 501250 A GS1AF GS1AF
Other versions: please consult our Customer Care Centre.
25
TeSys K
Thermal overload relays for use on class 10A unbalanced loads: for above references LR2-K0305 to LR2-K0316 only, replace the prex LR2 with LR7.
Accessories
Prewiring kit Allowing direct connection of the NC contact of relay LRD-0135 or LR3-D01 D35 to the contactor Terminal blocks (1) For clip-on mounting on 35 mm mounting rail (AM1-DP200) or screw xing For independent mounting of the relay EverLink Terminal blocks Separate terminal block Terminal block adapter For mounting a relay beneath an LC1-D115 or D150 contactor Stop or electrical reset Remote (3) Tripping or electrical reset device Remote (3) All relays except LRD0135 and LR3D01D35 LA7D03 (4) (1) Terminal blocks are supplied with terminals protected against direct nger contact and screws in the open ready-to-tighten position. (2) To order a terminal block for connection by lug-clamps, the reference becomes LA7-D30646. (3) The time for which the coil of remote tripping or electrical resetting device LA7-D03 or LAD-703 can remain energised depends on its rest time: 1 s pulse duration with 9 s rest time; maximum pulse duration of 20 s with a rest time of 300 s. Minimum pulse time 200 ms. (4) Reference to be completed by adding the code indicating the control circuit voltage. LRD0135 and LR3D01D35 LAD703 (4) LRD3, LR3D3, LRD35 LA7D3058 LRD313 LRD365 LAD9R3 LRD0135 and LR3D01D35 LRD3, LR3D3, LRD35 LR2K LAD7B10 LA7D3064 (2) LA7K0064 For use on LC1D09D18 LC1D25D38 LAD7C1 LAD7C2
26
TeSys D
Thermal overload relays for use with unbalanced loads Class 10A with connection by screw clamp terminals and lug-clamp terminals:
In the reference selected above, change LRD(except LRD4ppp) to LR3D Example: LRD01 becomes LR3D 01 Example with EverLink terminals: LRD340 becomes LR3D 340 Example with lug-clamp terminals: LRD3406 becomes LR3D 3406 (2) For independent mtg. on a DIN rail, order an EverLink LAD96560 terminal block.
Other versions: please consult our Customer Care Centre.
27
TeSys
LR9
Fuse to be used with selected relay aM gG 160 250 80 125 200 250 315 500 800 800
Compensated and differential Class 10 Class 20 LR9D5567 LR9F5569 LR9F5557 LR9F5563 LR9F5567 LR9F5569 LR9F5571 LR9F7575 LR9F7579 LR9F7581
60100 90150 3050 4880 60100 90150 132220 200330 300500 380630
D115 and D150 D115 and D150 F115F185 F115F185 F115F185 F115F185 F185F400 F225F500 F225F500 F400F630 and F800
LR9D5367 LR9D5369 LR9F5357 LR9F5363 LR9F5367 LR9F5369 LR9F5371 LR9F7375 LR9F7379 LR9F7381
Accessories
Remote control Function Electrical reset (1) Reset by exible cable (length 0.5 m) Adapter for door interlock mechanism Operating head for pushbutton Spring return Rod with snap-off end Adjustable from 17 to 120 mm Insulated terminal blocks For relays LR9-F557, F563, F567, F569, F57, F63, F67 and F69 Set of 2 blocks LA9F103 (1) The time for which the coil of remote electrical reset device LA7-D03 can remain energised depends on its rest time: 1 s pulse with 9 s rest time; 5 s pulse duration with 30 s rest time; 10 s pulse duration with 90 s rest time: maximum pulse duration 20 s with rest time of 300 s. Minimum pulse time: 200 ms. (2) Reference to be completed by adding the coil voltage code, see page 5/27
Other versions: please consult our Customer Care Centre.
28
TeSys
LR/LT
Relay type
Relay setting range For use with contactor References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC
0.560 A
Relay type
Relay setting range References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC
Relay type
Relay setting range References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC Accessories: please consult your Schneider Electric agency.
29
TeSys T
Type of eldbus
Supply voltage References Current range 0.48 A 1.3527 A 5100 A
Ethernet
24 VDC LTMR08EBD LTMR27EBD LTMR100EBD 100240 VAC LTMR08EFM LTMR27EFM LTMR100EFM
Modbus
24 VDC LTMR08MBD LTMR27MBD LTMR100MBD 100240 VAC LTMR08MFM LTMR27MFM LTMR100MFM
Probus DP
24 VDC LTMR08PBD LTMR27PBD LTMR100PBD 100240 VAC LTMR08PFM LTMR27PFM LTMR100PFM
Type of eldbus
Supply voltage References Current range 0.48 A 1.3527 A 5100 A
CANopen
24 VDC LTMR08CBD LTMR27CBD LTMR100CBD 100240 VAC LTMR08CFM LTMR27CFM LTMR100CFM
DeviceNet
24 VDC LTMR08DBD LTMR27DBD LTMR100DBD 100240 VAC LTMR08DFM LTMR27DFM LTMR100DFM
Extension module
Type of module
Inputs voltage References
Control unit
Type of terminal
Supply voltage Reference
Compact display
24 VDC LTMCU
30
TeSys T
Type of transformer
Operational current References primary secondary
External
100 A 1A LT6CT1001 LT6CT2001 LT6CT4001 LT6CT8001 200 A 400 A 800 A
Closed
65 A 30 TA30 85 A 50 PA50 160 A 80 IA80 250 A 120 MA120 400 A 200 SA200 630 A 300 GA300
Split
85 A 46 POA 250 A 110 GOA
Triple
90C 110C 120C DA1TT120 130C 140C 150C 160C 170C
DA1TT090 DA1TT110
Accessories (1)
Type of accessory
Length of cable References
Connecting cable
Controller / Extension module 0.04 m LTMCC004 0.3 m LU9R03 1m LU9R10
Type of accessory
Length of cable References (1) For other connection accessories, see www.schneider-electric.com
Connecting cable
Controller/ Display 1m 3m 5m
Connection kit
PC serial port
31
TeSys
LT3, LT6
Relay type
For use with contactor Motor current Basic reference, to be completed
Protection unit
Type
without fault memory Connection by cage connectors a 50/60 Hz c On front panel: fault and voltage signalling indicator a 50/60 Hz c a 50/60 Hz or c with fault memory
with automatic reset with thermistor short-circuit detection Voltage 115 V 230 V 24 V 115/230 V 24/48 V 24230 V Output contact NC NC NC NC + NO NC + NO 2 CO Reference LT3SE00F LT3SE00M LT3SE00F LT3SA00M LT3SA00ED LT3SA00MW
On front panel: fault and voltage signalling indicator, Test and Reset button a 50/60 Hz 400 V 24/48 V 115/230 V c a 50/60 Hz or c 24/48 V 24230 V NC + NO NC + NO NC + NO NC + NO 2 CO LT3SM00V LT3SM00E LT3SM00M LT3SM00ED LT3SM00MW
Accessories
Type
Normal operating temperature (NOT) Integrated triple probes Normal operating temperature (NOT) Surface probes PTC thermistor probes for LT3 relays 90 C DA1TT090 60 C DA1TS060 110 C DA1TT110 70 C DA1TS070 120 C DA1TT120 80 C DA1TS080 130 C DA1TT130 90 C DA1TS090 140 C DA1TT140 100 C DA1TS100 150 C DA1TT150 160 C DA1TT160 170 C DA1TT170
32
TeSys
Vario
Switch disconnectors
12175 A
1/L1
3/L2 4/T2
2/T1
Type
Colour: Handle / Front plate Front plate dimensions (mm) Fixing Degree of protection Rated insulation voltage (Ui) Thermal current in open air (Ith) 12 A 20 A
6/T3
5/L3
1/L1
3/L2 4/T2
2/T1
Type
Colour: Handle / Front plate Front plate dimensions (mm) Fixing Degree of protection Rated insulation voltage (Ui) Thermal current in open air (Ith) 12 A 20 A 25 A 32 A 40 A 63 A 80 A 125 A 175 A
6/T3
5/L3
Add-on modules
Main pole modules Switch rating References Neutral pole module with early make and late break contacts Switch rating References Earthing module Switch rating References Auxiliary contact block modules Contact type References
For mini-Vario
12 A VZN12 1220 A VZN11 1220 A VZN14 NO VZN05 NC VZN06 20 A VZN20
For Vario
12 A VZ02 1240 A VZ11 1240 A VZ14 NO + NC VZ7 20 A VZ01 25 A VZ0 32 A VZ1 40 A VZ2 63 A VZ3 80 A VZ4
33
TeSys
GV2, LC
D.O.L. starters
with circuit-breaker Level of service Power at 400 V Type of components Basic reference, to be completed Coordination: Up to: Type 1 5.5 kW incorporated in the circuit-breaker GV2ME GV2DM GV2DP 15 kW Combination automatic motor starter with overload protection with fuse protection Type 2 37 kW Fuse carrier + plate-mounted contactor LC4D
Starters GV2-ME
Non-reversing Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (kW) 400/415 V 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 440 V 0.37 0.55 0.75 1.1 1.5 2.2 4 5.5 500 V 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 914 170 GV2ME16 LC1K12 GV2ME16K1 GV2ME16K2 610 138 GV2ME14 LC1K09 GV2ME14K1 GV2ME14K2 46.3 78 GV2ME10 LC1K06 GV2ME10K1 GV2ME10K2 2.54 51 GV2ME08 LC1K06 GV2ME08K1 GV2ME08K2 1.62.5 33.5 GV2ME07 LC1K06 GV2ME07K1 GV2ME07K2 11.6 Setting range of thermal trips Fixed magnetic tripping current 13 Irth 22.5 GV2ME06 LC1K06 GV2ME06K1 GV2ME06K2 For customer assembly Motor circuit-breaker Contactor Factory assembled Basic reference, to be completed with code indicating control circuit voltage Reversing
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts a 50400 Hz c (1) 24 B7 BW3 110 F7 220/230 M7 230 P7 230/240 U7 380/400 Q7 -
(1) Low consumption coil (1.5 W), wide range (0.71.3 Uc) and with integral suppression device as standard.
34
(1) Circuit-breaker GV3P without downstream EverLink terminal block. A standard GV3P can also be used by removing the downstream terminal block. (2) For side by side circuit-breaker/contactor mounting, order accessory GV3S.
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts 24 220 a 50400 Hz c (3) B7 BD M7
230 P7
(3) Low consumption coil, wide range (0.7 to 1.25 Uc) and with suppression device as standard (bidirectional peak limiting diode).
Other versions: please consult our Customer Care Centre.
35
TeSys U
=
Function characteristics, LUB + LUCA Maximum motor power
< 400/415 V - Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual reset following thermal fault. 0.09 kW 0.25 kW 1.5 kW 5.5 kW 7.5 kW 15 kW LUB12 LUB12 LUB12 LUB12 LUB32 LUB32
+
Power base
Non-reversing Reversing (1) LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp
Power base
Non-reversing LUB120 LUB120 LUB120 LUB120 LUB320 LUB320
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual reset following thermal fault. - Thermal overload test function. (3) For single-phase-motors, replace LUCBpppp by LUCCpppp.
Power base
Non-reversing LUB120 LUB120 LUB120 LUB120 LUB320 LUB320
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual, automatic or remote reset, - Thermal overload test function, - Overtorque and no-load running, alarm, - Motor operation log, - Motor parameters display on LUCM.., PC or HMI, - Integrated Modbus communication.
(1) Complete the references of the power bases according to the following table. (2) Complete the references of the control units according to the following table. Standard control circuit voltages 24 V DC 24 V AC 48 V AC / 4872 V DC 110240 V AC / 110220 V DC
pp pp BL B ES FU
36
TeSys U
+
Type of optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
=
Thermal overload alarm
NO NO YES NO 1 NO NA LUFW10
Communication modules
Type of communication
Only compatible with 24 V DC control units LUCA..BL, LUCB..BL, LUCD..BL, LUCM..BL Transfer speed Number of slaves Pre-wired coil connection (A1 A2) Connecting cable to PC References (1) Network Interface Module.
Modbus
YES 19.2 Kbps 31 per Modbus master LU9BN11C, LU9MRC
Modicon STB
YES
Probus DP CANopen
YES YES 20 K1 Mbps module LU9BN11L, LU9MRL TSXCANCpp LULC08
DeviceNet
YES
Dpg. on NIM (1) 9.612 Mbps Dpg. on Network LU9BN11L, LU9MRL LU9RDDpp Interface Module module LU9BN11L, LU9MRL TSXPBSCApp LULC07
125500 Kbaud 167 Kbps 63 per DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09 ASILUFC51 master LU9BN11C, LU9MRC XZCG0142
Contact blocks
Type of contact block
Signalling contacts 2 auxiliary contacts module References Screw clamp terminals Without connections of any fault position of control handle
Add-on
NC (95-96) NO (17-18) LUA1C11 LUA1C110 NO (97-98) NO (17-18) LUA1C20 LUA1C200
Auxiliary
NO (33-34) NO (43-44) LUFN20 NC (31-32) NO (43-44) LUFN11 NC (31-32) NC (41-42) LUFN02
37
TeSys
LUTM
TeSys GV3L Circuit-breakers
=
Control base for use with contactors
TeSys D (LC1D..) LUTM10BL
+
Multifunction control unit
TeSys F (LC1F..) LUTM20BL Class 5 to 35 LUCMT1BL
Function characteristics
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual, automatic or remote reset, - Thermal overload test function, - Overtorque and no-load running, alarm, - Motor operation log, - Motor parameters display on LUCM.., PC or HMI, - Integrated Modbus communication.
ADVANCED protection
Function characteristics
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual reset following thermal fault. - Thermal overload test function.
Current transformers
Type of transformer
Supply voltage Operating current References Primary Secondary 24 V DC 30 A 1A LUTC0301 LUTC0501 LUTC01001 LUTC02001 LUTC04001 LUTC05001 50 A 100 A 200 A 400 A 800 A
Above 32 A, the TeSys U controller provides a motor starter management system solution identical to that provided by the TeSys U starter-controller. Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter whose functions are the same as those of a TeSys U starter-controller and, in particular, provides the following functions: overload protection, motor starter control and application monitoring. It comprises a control unit, whose adjustment range is compatible with the secondary of current transformers, and a control base that also enables the tting of a function module or communication module. It requires a 24 V DC external power supply.
Other versions: please consult our Customer Care Centre.
38
TeSys
LUTM
+
Type of optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
=
Thermal overload alarm
NO NO YES NO 1 NO NA LUFW10
TeSys rotating handles for Kit IP54 black handle IP54 kit red handle and yellow front IP65 kit red handle and yellow front
Communication modules
Type of communication
Only compatible with 24 V DC control units LUCA..BL, LUCB..BL, LUCD..BL, LUCM..BL Transfer speed Number of slaves Pre-wired coil connection (A1 A2) Connecting cable to PC References
Modbus
YES 19.2 Kbps 31 per Modbus master LU9BN11C, LU9MRC VW3 A8 306 Rpp LU9RDDpp LUFC033
Modicon STB
YES Dpg. on NIM (1) Dpg. on Network Interface Module LU9BN11L, LU9MRL LU9RCDpp LULC15
CANopen
YES 20 K1 Mbps 128 per CANopen module LU9BN11L, LU9MRL TSXCANCpp LULC08
DeviceNet
YES 125500 Kbaud 63 per DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09
Parallel wiring
YES NA 8 per LU9GC02 splitter box LU9Rxx TSXCDPppp LUFC00
39
TeSys
Starters
N
D.O.L.
0.0637 kW L L L L GV2ME GV3PC GV3CE LE2K LE2D 0.5530 kW L L L GV2LC GV-NGC 0.375.5 kW L L L L LE1GVME 0.2545 kW L L LE1M LE1D
N standard
Standard power ratings of 3-phase motors in category AC3 400/415 V Starters Isolating device manual auto switch-disconnector-fuse circuit-breaker fuse carrier Protection Communication Basic reference Non-reversing short-circuit overload
Reversing
40
2 stage
7.575 kW L L L L LE6D LE3D
0.0611 kW L L L L GV2ME
41
TeSys
Quickt
Installation system
Presentation
TeSys Quickt is a modular system which standardises and simplies the implementation of motor starters with its pre-wired control and power circuits. Installation of a motor starter becomes quick, simple, safe and exible. In addition, this system: b enables the motor starter to be customised at a later date, b reduces maintenance time and b optimises panel space by reducing the number of terminals and intermediate interfaces and the amount of ducting. The motor starters concerned are those created by combining: GV2 ME or GV3 P circuit-breakers, with an operating limit of 80% of the maximum current at an ambient temperature of 60 C, up to 690 V with 9 to 65 A TeSys D (LC1) contactors. This offer comprises components for pre-wiring b the power part, b the control part.
Type
Maximum c.s.a. of connection Use Number of starters Reference
Downstream
6 mm2 Motor cables LAD331
Type
Composition Reference (1) For a reversing starter order 2 connection kits LAD252
42
Type
TeSys D coil voltage Type of coil control relay Type of motor starter Reference
Connection module
12250 V AC or 5130 V DC Electronic Direct LAD9AP31 Reversing LAD9AP32 24 V DC Without relay Direct LAD9AP3D1 Reversing LAD9AP3D2
Type
PLC/motor starter side connectors Reference
Accessories
Type
Connectors Gauge / c.s.a. Reference L = 0.3 m 0.5 m 1m 2m 3m 5m
(1) From connection module LAD9AP3p to splitter box LU9G02 or module STBEPI2145
Type
Use Reference
43
Components
Sodium vapour lamps
N low pressure
Non-corrected P (W) IB (A) C (F) Max. number of lamps 31.2 6 12 15 21 27 35 50 100 140 152 174 198 250 338 496