Procedure Using UT Slide
Procedure Using UT Slide
1. Draw the actual weld profile on the transparent(plastic) ,draw also the mirror image. 2. If you got a signal, maximize and read the BPL value .For example 42mm 3. From the test plate, measure the distance from the Probe Index to the Center of the Weld using a ruler. This is called the Stand-off Distance.For example 40mm. 4. On the slide, put the probe index at Stand- Off(40mm )from the center weld. See below.
Stand Off=40mm
Center of weld
60
BPL
5. Mark the BPL (42mm)on the slide. This is where the defect is located on the weld on its mirror image. Note that, If the BPL does not landed on the weld area, it means it is a non-relevant indication.
Stand Off=40mm
10 20 30
Center of weld
10 20 30 40
10 20
Defect
BPL
30
6.Draw straight line from the defect upwards to know the exact location above the surface and depth of the defect on its original image. 7. From the slide, read the surface distance and mark on the test plate.
Surface Distance=36mm
Center of weld
10 20 30
Depth= 3mm
10 20 30 40 50 20 10
Defect
BPL
30
Note:
Stand Off Distance= Distance from Probe Index to the weld center line Surface Distance = Distance from Probe Index to the defect above the surface.