Procedure Using UT Slide

1. Draw the weld profile and its mirror image on a transparent sheet. Measure the beam path length (BPL) value, such as 42mm, from the ultrasonic test. 2. Measure the stand-off distance from the probe index to the weld center, such as 40mm. Mark the BPL value from the stand-off distance on the transparent sheet. 3. Draw a line from the defect upwards to determine the exact location and depth of the defect, such as 3mm deep, on the original weld image. Then mark the surface distance, such as 36mm, on the test plate.

Uploaded by

Tonyo Ayshiyu
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
2K views

Procedure Using UT Slide

1. Draw the weld profile and its mirror image on a transparent sheet. Measure the beam path length (BPL) value, such as 42mm, from the ultrasonic test. 2. Measure the stand-off distance from the probe index to the weld center, such as 40mm. Mark the BPL value from the stand-off distance on the transparent sheet. 3. Draw a line from the defect upwards to determine the exact location and depth of the defect, such as 3mm deep, on the original weld image. Then mark the surface distance, such as 36mm, on the test plate.

Uploaded by

Tonyo Ayshiyu
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

Steps Using Ultrasonic Beam Plotter

1. Draw the actual weld profile on the transparent(plastic) ,draw also the mirror image. 2. If you got a signal, maximize and read the BPL value .For example 42mm 3. From the test plate, measure the distance from the Probe Index to the Center of the Weld using a ruler. This is called the Stand-off Distance.For example 40mm. 4. On the slide, put the probe index at Stand- Off(40mm )from the center weld. See below.
Stand Off=40mm

Center of weld

60

BPL

5. Mark the BPL (42mm)on the slide. This is where the defect is located on the weld on its mirror image. Note that, If the BPL does not landed on the weld area, it means it is a non-relevant indication.
Stand Off=40mm
10 20 30

Center of weld

10 20 30 40

10 20

Defect
BPL

30

6.Draw straight line from the defect upwards to know the exact location above the surface and depth of the defect on its original image. 7. From the slide, read the surface distance and mark on the test plate.
Surface Distance=36mm

Center of weld
10 20 30

Depth= 3mm
10 20 30 40 50 20 10

Defect
BPL

30

Note:
Stand Off Distance= Distance from Probe Index to the weld center line Surface Distance = Distance from Probe Index to the defect above the surface.