Sensor Installation Manual: Enviromux Series
Sensor Installation Manual: Enviromux Series
MAN057
TABLE OF CONTENTS
Connect Sensors to ENVIROMUX-MINI....................................................................................................................... 2 ENVIROMUX-T, RH, or TRH....................................................................................................................................... 2 ENVIROMUX-LD ......................................................................................................................................................... 3 Contact Sensors .......................................................................................................................................................... 3 Connect Sensors to ENVIROMUX-SEMS-16............................................................................................................... 4 RJ45 Sensors .............................................................................................................................................................. 4 Temperature and Humidity ....................................................................................................................................... 4 Liquid Detection ........................................................................................................................................................ 4 Contact Sensors ....................................................................................................................................................... 5 Digital In Terminals................................................................................................................................................ 5 BEACON and SIREN Connections ............................................................................................................................ 7
TABLE OF FIGURES
Figure 1- Connect sensors to ENVIROMUX-MINI ............................................................................................................................. 2 Figure 2- Liquid detection sensor....................................................................................................................................................... 3 Figure 3- Terminal block for dry-contact sensors............................................................................................................................... 3 Figure 4- Sensors connected by cables with RJ45 connectors.......................................................................................................... 4 Figure 5- ENVIROMUX-LDS sensor mounting .................................................................................................................................. 4 Figure 6- Contact sensor wired to RJ45 socket ................................................................................................................................. 5 Figure 7- DIGITAL IN terminal block on ENVIROMUX-SEMS-16 ................................................................................................... 5 Figure 8- Basic DIGITAL IN Terminal Connections ........................................................................................................................... 6 Figure 9- Connections for sensor with tamper switch ........................................................................................................................ 6 Figure 10- Connect visual and audible external indicators................................................................................................................. 7
INTRODUCTION
Many different sensors can be connected to the ENVIROMUX Series Environment Monitoring Systems. Series models include ENVIROMUX-MINI (and related models) and ENVIROMUX-SEMS-16 (and related models). A complete listing of available sensors and accessories can be found at http://www.networktechinc.com/enviro-rems.html for the ENVIROMUX-SEMS-16, and at http://www.networktechinc.com/enviro-mini.html for the ENVIROMUX-MINI. Manuals for each Environment Monitoring System covering installation and configuration for all features can also be found at these websites. This manual is only provided to instruct how to connect the various sensors to these systems.
2.
Note: Mounting the sensor in the path of a fan or on a heated surface may affect the accuracy of the sensors readings. Note: For best results, use the ENVIROMUX-T-IND with model ENVIROMUX-MINI-IND.
ENVIROMUX-LD
Connect the liquid detection sensor ENVIROMUX-LD to the terminals marked "WATER" or CONTACT. The twisted orange sensing cable should be placed flat on the surface (usually the floor) where liquid detection is desired. If tape is required to hold the sensor in place, be sure to only apply tape to the ends, exposing as much of the sensor as possible. At least 5/8" of the sensor must be exposed for it to function. (See Figure 2)
Contact Sensors
Up to four dry-contact sensors or liquid detection sensors can be connected to the terminals marked CONTACTS. Sensors with 16-26 AWG connection wires that operate on 5V at 10mA maximum current may be used. A contact resistance of 10k or less will be interpreted by the ENVIROMUX-MINI as a closed contact. Examples of Dry-Contact Sensors for the ENVIROMUX-MINI: NTI # ENVIROMUX-EBS ENVIROMUX-IMD-P ENVIROMUX-M-DCS Description Emergency Button Infrared Motion Sensor w/power Door Contact Sensor NTI # ENVIROMUX-SDS-PA ENVIROMUX-TDS Description Smoke Detection Sensor-Power added Tamper Switch
To install the dry-contact sensor(s): A. Attach the positive lead to a terminal corresponding to a "+5V" marking on the ENVIROMUX-MINI and the ground lead to the next terminal to the right that will correspond to a marking on the ENVIROMUX-MINI. Tighten the set screw above each contact. Terminal sets are numbered 1-4. B. Mount the sensors as desired.
1 +5V
1 + 5 V
C O N T A C T S
2 3 + 5 V
4 + 5 V
Example: Device with potential-free break/make contact relay (i.e. door switch)
+ 5 V
Note: Shielded CAT5 cable is required between the sensor and the ENVIROMUX to maintain CE compliance of the sensor.
Liquid Detection
Connect the liquid detection sensor of the ENVIROMUX-LDS to the two-wire cable and secure the two-wire cable to the terminals marked "WATER SENSOR". The twisted orange sensing cable should be placed flat on the surface (usually the floor) where liquid detection is desired. If tape is required to hold the sensor in place, be sure to only apply tape to the ends, exposing as much of the sensor as possible. At least 5/8" of the sensor must be exposed for it to function.
Contact Sensors
Some sensors do not have RJ45 connectors on them and instead have terminal blocks. These can either be connected to the "DIGITAL IN" connectors or they can be terminated and plugged into the remaining RJ45 connectors (see Figure 6). (The illustration uses CAT5 patch cable to make cable connection easy.) Examples of these sensors include ENVIROMUX-IMD (motion detector), ENVIROMUX-IMD-CM (ceiling mount motion detector), ENVIROMUX-VSS (vibration sensor), ENVIROMUXSDS (smoke detection), and ENVIROMUX-GBS (glass break sensor). ( For more on these and other sensors, see the ENVIROMUX-SEMS-16 manual, pages 2 and 3.)
Note: For sensors requiring 5VDC power source, substitute the wire connected to pin 4 (see below) instead of pin 7.
When applying CAT5 cables to contact sensors for plug-in to the RJ45 Sensor sockets, the following socket-to-sensor wiring must be followed:
Digital In Terminals
To connect contact sensors without using RJ45 connectors, terminal blocks have been provided labeled "DIGITAL IN". Two wire switch-only type sensors can be connected to the plus (+) and minus (-) terminals of each or 4 sets of terminals. If the sensors require a 12V power source to operate, additional 12V and ground terminals have been provided for each set of terminals. Connect each two-wire or four-wire contact sensor using 16-26 AWG wire. Devices connected to DIGITAL IN terminals 1-7 must be rated at 50mA or less. Devices connected to DIGITAL IN terminal 8 must be rated at 650mA or less.
1 2 3
+ 12V
DIGITAL IN
+ 12V + 12V
+ 12V
7
+ 12V
8
+ 12V
+ 12V + 12V
3
+ 12V
4
+ 12V
+ 12V + 12V
For additional examples for sensor and accessory wiring diagrams, see the ENVIROMUX-SEMS-16 manual.
WARNING
Devices connected cannot exceed 180mA contact load.
See a complete listing of available sensors and accessories at http://www.networktechinc.com/enviro-rems.html for the ENVIROMUX-SEMS-16, and at http://www.networktechinc.com/enviro-mini.html for the ENVIROMUX-MINI. Manuals for each product covering installation and configuration for all features can also be found at these websites.
Pin 1 2 3 4 5 6 7 8
Wire Color White/Orange Orange White/Green Blue White/Blue Green White/Brown Brown
Pair 2 2 3 1 1 3 4 4
T R T R T R T R 1 2 3 4 5 6 7 8 + - + - + - + -
TRADEMARK ENVIROMUX is a registered trademark of Network Technologies Inc in the U.S. and other countries. COPYRIGHT Copyright 2008, 2011 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. CHANGES The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users.