100% found this document useful (7 votes)
4K views1 page

Ut Rule of Thumb

This document provides guidelines for using ultrasound to determine depth and identifies the optimal probe angle for root checks. It also contains information on x-ray exposure times and distances according to the inverse square law. A 70 degree probe is recommended for root checks over a 60 degree probe to better identify defects. Exposure time must increase with distance and decrease with proximity to maintain the same radiation intensity.

Uploaded by

Tonyo Ayshiyu
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (7 votes)
4K views1 page

Ut Rule of Thumb

This document provides guidelines for using ultrasound to determine depth and identifies the optimal probe angle for root checks. It also contains information on x-ray exposure times and distances according to the inverse square law. A 70 degree probe is recommended for root checks over a 60 degree probe to better identify defects. Exposure time must increase with distance and decrease with proximity to maintain the same radiation intensity.

Uploaded by

Tonyo Ayshiyu
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

RULE OF THUMB

ULTRASONIC To find a Depth , given a reading in a screen or the BPL by approximation: On the Half skip area:
D

For 70: D= BPL 3 For 60: D=BPL 2 For 45 D= BPL 1.4

On the full skip area:


D

For 70: D= 2T-(BPL 3) For 60: D= 2T-(BPL 2) For 45 D=2T- (BPL 1.4)

Root Check Technique: A s much as possible a 60 probe is not use for a root check because even a good root bead will produced a high signal which will be easily mistaken for a root defect. A 70 is a better option because a good root bead will produced only a small echo, which means a root defect that produces a high signal like lack of root penetration will be easily identified. See sketch below.

60 Probe

Signal not reflected Reflected signal More sounds reflected back to the probe produces High signal on the screen.

70 Probe
Less signal reflected back to the probe produces small echo on the screen.

RADIOGRAPHY: The intensity of radiation is inversely proportional to the SFD. Inverse Square Law: I x D = I x D When the distance is doubled increased the exposure time by 4 times. When the distance is reduced to half of its original distance, the exposure time will reduce to of the its original exposure time. Time x Dist. = Time x Dist. RADIOGRAPHY: Safe Distance Safe Distance=26 Curies Safe Distance= Ci x 37 x130 By Approximation Exact formula

Edmundo T. Botor Jr.


Senior CSWIP 3.2 No.3147-2 PCN Level 2 No.207763

7.5

You might also like