Gyptone Brochure (03 - 04)
Gyptone Brochure (03 - 04)
Gyptone Brochure (03 - 04)
CI/SfB
(35)
SRf7
ARTECO
Gyptone
A unique combination Acoustics and aesthetics
Total systems As part of the British Gypsum total system, the Arteco Gyptone range is backed by the expertise of the UKs leading supplier and foremost authority on internal wall and ceiling systems, with a proven record of providing effective solutions for many of the worlds most prestigious buildings. Our unrivalled experience, technical expertise and state-of-the-art technology has enabled us to develop unique systems that meet the most demanding performance and build criteria and the most rigorous quality standards, yet are simple and quick to install.
SY
STEM W
that comes with every British Gypsum proprietary systems now benefit from SpecSure, our ground-breaking new lifetime system warranty that supports and protects the integrity of our market leading drywall systems from specification to installation. Arteco ceilings are no exception. It is this guaranteed performance that continues to convince professional specifiers to choose our products and systems above all others for their entire internal lining solutions.
Technical support The Arteco Gyptone range is supported by the most comprehensive technical support resource in the industry, the British Gypsum Drywall Academy. Through the Drywall Academy we can
Front cover Gyptone LINE 4 tiles Top opposite page Gyptone LINE 6 board Bottom opposite page Gyptone QUATTRO 20 tiles Top Gyptone QUATTRO 47 board Bottom Gyptone LINE 6 board
offer advice and assistance with product selection, design and detailing, health and safety, statutory requirements and any other installation issues.
In addition to the
RR
ANTY
Performance warranty
SP
LIFETIM
E
ECSURE
Gyptone
The Gyptone range of perforated, pre-finished gypsum tiles, planks and boards offers a high performance and outstanding quality ceiling while still providing limitless design options for the interiors of a wide variety of buildings. Gyptone unites distinctive designs, gypsums durability and superb sound absorption characteristics. It also offers easy maintenance and enables redecoration without affecting acoustic performance.
Sound attenuating Sound absorbing Class 0 / Euroclass B RH70 Distinctive geometric patterns Ceiling and wall lining Creative freedom
The versatile range is available in a number of geometric perforations; these include QUATTRO, POINT and LINE, which can be combined with unperforated boards and tiles to allow a natural transition between open areas. With their stylish perforated patterns and special acoustic tissue bonded to the back face, Gyptone gives designers and users an ideal acoustic environment while maintaining its exciting aesthetic appeal.
Gyptone boards
The Gyptone range of boards brings a new creative freedom to ceiling and wall lining design, whether the concept calls for sweeping yet elegant links between open areas or for a simple, natural transition between rooms. Gyptones attractive boards for flat or curved surfaces can be decorated and redecorated without affecting acoustic performance, and add gypsums fire safety and durability to a true aesthetic appeal.
QUATTRO 41 board
56.5 487 113
QUATTRO 46 board
106.5 387 213
Size Thickness Edge Grid system Perforation size Perforated area Weight PSR number* Reaction to fire
1200 x 2400mm 12.5mm Tapered CasoLine MF 12 x 12mm 16% 8kg/m2 C10A091 Class 0 / Euroclass B
Size Thickness Edge Grid system Perforation size Perforated area Weight PSR numbers* Reaction to fire
1200 x 2400mm 12.5mm Tapered CasoLine MF 12 x 12mm 10% 8kg/m2 C10A014, C10A015 Class 0 / Euroclass B
Dn,c dB
Dn,c dB
RO TT A U Q
41
0.8
0.8
0.6
0.6
RO TT A U Q
0.4
0.4
46
RO TT A U Q
0.2
0.2
0.0
0.0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
47
Absorption Class / Plenum depth Class D / 400mm Class D / 400mm with 100mm Isowool General Purpose Roll
E N LI
e rv Cu
40
40
20
20
E N LI
6
0
0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
QUATTRO 47 board
106.5 87 63 213
Size Thickness Edge Grid system Perforation size Perforated area Weight PSR numbers* Reaction to fire
1200 x 2400mm 12.5mm Tapered CasoLine MF 12 x 12mm 6% 8kg/m2 C10A016, C10A017 Class 0 / Euroclass B
Size Thickness Edge Grid system Perforation size Minimum radius Perforated area Weight PSR numbers* Reaction to fire
900 x 2400mm 6.5mm Tapered CasoLine CURVE 6 x 80mm 1200mm 14% 5kg/m2 C10A018, C10A019 Class 0 / Euroclass B
0.8
0.8
0.6
0.6
0.4
0.4
0.2
0.2
0.0
0.0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
40
40
Dn,c dB
20
Dn,c dB
500
20
125
250
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
LINE 6 board
80 440 160 80 40
Size Thickness Edge Grid system Perforation size Perforated area Weight PSR numbers* Reaction to fire
1200 x 2400mm 12.5mm Tapered CasoLine MF 6 x 80mm 13% 8kg/m2 C10A012, C10A013, C10A001, C10A002 Class 0 / Euroclass B
0.8
0.6
0.4
0.2
0.0
125
250
500
1000
2000
4000
Frequency (Hz)
40
Dn,c dB
20
125
250
500
1000
2000
4000
Frequency (Hz)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
BASE 31 tile
27.5 95
LINE 4 tile
55
600 x 600mm 12.5mm A / E15 - 15mm T Section D1 - CasoLine T24 D1 Unperforated 9kg/m2 C10A008 Class 0 / Euroclass B
Size Thickness Edge / Grid system Perforation size Perforated area Weight
600 x 600mm 12.5mm E15 - 15mm T Section 6 x 95mm 18% 8kg/m2 C10A004 Class 0 / Euroclass B
31
BA an SE k 33
pl
LI NE
pl an k
8
1.0
0.8
0.6
0.4
0.2
0.0
125
250
500
1000
2000
4000
Frequency (Hz)
11
pl PO an IN k
T
Hz
125 250
500
1k
2k
4k
w 0.65
NRC 0.60
15
PO IN T
12
40
40
Dn,c dB
Dn,c dB
20
20
QU
AT
TR
pl QU an A k
O
20
TT RO
55
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
dB 17.1 27.6 33.8 40.5 43.3 42.5 (No quilt) dB 16.6 31.0 35.9 41.5 44.9 47.0
QU AT TR O
POINT 11 tile
34.25
POINT 12 tile
34.25 111.5 308.5
Size Thickness Edge / Grid system Perforation size Centres between holes Perforated area Weight
600 x 600mm 12.5mm E15 - 15mm T Section 6.5mm 15mm 12% 8kg/m2 C10A005 Class 0 / Euroclass B
Size Thickness Edge / Grid system Perforation size Centres between holes Perforated area Weight
600 x 600mm 12.5mm E15 - 15mm T Section 6.5mm 15mm 5% 8kg/m2 C10A006 Class 0 / Euroclass B
0.8
0.8
0.6
0.6
0.4
0.4
0.2
0.2
0.0
0.0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
40
40
Dn,c dB
20
Dn,c dB
125 250 500 1000 2000 4000
20
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
QUATTRO 20 tile
32.25
QUATTRO 22 tile
32.25 126 283.5
Size Thickness Edge / Grid system Perforation size Centres between holes Perforated area Weight
600 x 600mm 12.5mm E15 - 15mm T Section D1 - CasoLine T24 D1 9 x 9mm 19mm 18% 8kg/m2 C10A003 Class 0 / Euroclass B
Size Thickness Edge / Grid system Perforation size Centres between holes Perforated area Weight
600 x 600mm 12.5mm E15 - 15mm T Section D1 - CasoLine T24 D1 9 x 9mm 19mm 9% 8kg/m2 C10A007 Class 0 / Euroclass B
0.8
0.8
0.6
0.6
0.4
0.4
0.2
0.2
0.0
0.0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
40
40
Dn,c dB
20
Dn,c dB
500
20
125
250
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
dB 16.6 31.0 35.9 41.5 44.9 47.0 39 (-2;-8) (with 100mm Isowool General Purpose Roll)
10
BASE 33 plank
LINE 8 plank
178 25 95 55
POINT 15 plank
34 31
300 x 1800mm 300 x 2100mm 12.5mm E15 / A CasoLine T15p Unperforated 9kg/m2 C10A011 Class 0 / Euroclass B
Size Thickness Edge Grid system Perforation size Perforated area Weight
300 x 1800mm 300 x 2100mm 12.5mm E15 / A CasoLine T15p 6 x 95mm 15% 8kg/m2 C10A009 Class 0 / Euroclass B
Size Thickness Edge Grid system Perforation size Centres between holes Perforated area Weight
300 x 1800mm 300 x 2100mm 12.5mm E15 / A CasoLine T15p 6.5mm 15mm 11% 8kg/m2 C10A010 Class 0 / Euroclass B
0.8
0.8
0.6
0.6
0.4
0.4
0.2
0.2
0.0
0.0
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
40
40
40
Dn,c dB
Dn,c dB
20
20
Dn,c dB
125 250 500 1000 2000 4000
20
125
250
500
1000
2000
4000
125
250
500
1000
2000
4000
Frequency (Hz)
Frequency (Hz)
Frequency (Hz)
dB 17.1 27.6 33.8 40.5 43.3 42.5 (No quilt) dB 16.6 31.0 35.9 41.5 44.9 47.0
11
QUATTRO 55 plank
119
44
Size Thickness Edge Grid system Perforation size Centres between holes Perforated area Weight
300 x 1800mm 300 x 2100mm 12.5mm E15 / A CasoLine T15p 12 x 12mm 25mm 15% 8kg/m2 C10A034 Class 0 / Euroclass B
0.8
0.6
0.4
0.2
0.0
125
250
500
1000
2000
4000
Frequency (Hz)
40
Dn,c dB
20
125
250
500
1000
2000
4000
Frequency (Hz)
12
Grid Systems
CasoLine MF CasoLine T24 D1 CasoLine T15p 15mm or 24mm T sections
Edge Profiles
Edge A Edge D1 E15
3 6.25 6.25
12.5
Tapered
35gr 5.0
3.5
Technical information
Limitations Gyptone tiles, planks and boards are unsuitable for use in areas subject to continuously damp or humid conditions or subjected to temperatures consistently above 49C. They can be exposed to freezing temperatures without risk of damage. Environment Gyptone tiles, planks and boards are suitable for use under normal occupancy conditions. Buildings in which Gyptone is used should be dry, glazed and enclosed with environmental conditions of no greater than 70% relative humidity at 10-20C. Handling and storage British Gypsum fully accepts its responsibilities as a supplier of building materials and systems as required by Section 6 of the Health and Safety at Work Act 1974. However, in designing and installing systems incorporating British Gypsum products, full consideration must be taken of the legal requirements of: 1 Manual Handling Operations Regulations 1992. 2 Construction (Design and Management) Regulations 1994. 3 Control of Substances Hazardous to Health Regulations 1988 (COSHH). Your attention is brought to the following publications which give approved guidance: 1 Manual Handling Guidance on Regulations, ISBN 0 11 886335 5. 2 Managing Construction for Health and Safety ACOP, ISBN 0 7 7176 0792 5. 3 A Guide to Managing Health and Safety in Construction, ISBN 0 7176 0755 0. 4 Designing for Health and Safety in Construction, ISBN 0 7176 0807 7. 5 The Control of Substances Hazardous to Health in the Construction Industry, ISBN 0 11 885526 3. Safety Data Sheets (giving safety, handling and storage details) are available on request, or from our website: www.british-gypsum.com Contact British Gypsum Drywall Academy Advice Centre on 08705 456123. Reaction to fire The exposed surface of Gyptone tiles, planks and boards achieve Class 0 rating when tested to BS 476: Parts 6 and 7. Under Building Regulations Part B 2000 -Amendment 2002, the exposed surfaces of Gyptone tiles, planks and boards are designated Euroclass B. Gyptone ceilings provide good fire performance owing to the unique behaviour of the non-combustible gypsum core when subjected to high temperatures. Gypsum board is designated a material of limited combustibility within Building Regulations 1991. Acoustic performance Sound absorption Gyptone QUATTRO, POINT and LINE provide sound absorption when used in conjunction with an air space behind the ceiling. Tests have been carried out to BS EN 20354: 1993 and ISO 354: 1985 with a range of plenum depths . Increased levels of sound absorption can be achieved by including glass mineral wool over the back of the ceiling. The single figure rating practical sound absorption coefficients w , shown in tables on pages 4 - 12 are calculated in accordance with EN ISO 11654: 1997. The Noise Reduction Coefficient (NRC ) figures shown in tables on pages 4 - 12, are calculated in accordance with ASTM C423 -90a: 1992. Sound attenuation Gyptone QUATTRO, POINT and LINE are perforated tiles, planks and boards with an integral acoustic tissue designed to provide sound absorption within the area they are installed. Where room-toroom sound insulation is required the sound attenuation Dncw can be increased to 39dB with the inclusion of 100mm Isowool General Purpose Roll over the back of the ceiling. Alternatively, other design considerations can be adopted such as extending adjoining partitions into the ceiling void or installing a plenum barrier. Gyptone BASE is an unperforated product and has been tested to BS EN 20140-9: 1994 for room-to-room sound insulation. All products quote a PSR number. This is a unique number we allocate to all products and systems that references all the latest substantiations we hold. By quoting these figures on enquiries about the product, we are able to give you the most accurate and up to date advice and information.
13
Sitework Installation Gyptone boards are fixed to CasoLine MF or CasoLine CURVE systems. A range of access panels are available that allow access to the ceiling void. Gyptone D1 edge tiles are installed into CasoLine T24 D1 grid, and Gyptone planks are installed into CasoLine T15p grid systems. Gyptone A and E15 edge tiles are installed in a 15mm or 24mm grid. The designer should ensure the system used is capable of supporting the tile load. All ceiling tiles and planks are fully demountable, allowing access to the ceiling void. For full installation details, please refer to White Book and SiteBook sections c10 - CasoLine MF, c10.1 - CasoLine CURVE and c12 - CasoLine GRID. Fixtures Spot lights and downlighters are best located in Gyptone BASE or in the unperforated zones of other Gyptone designs. Maintenance Gyptone can be cleaned using a damp cloth. Most standard mild detergents can be used. Gyptone can be re-decorated, if required, using a roller and a suitable emulsion paint. The perforated tiles should not be spray painted as this may impair the sound absorption performance. Finishing Gyptone boards Refer to White Book and SiteBook section n15 - Jointing.
14 1
ARTECO
Other brochures in the Arteco range
British Gypsum
UK market leader in gypsum plaster and plasterboard systems, British Gypsum markets its products under the Gyproc, Thistle, Gypframe, Glasroc, Arteco, Rawl and Isowool* brand names. All British Gypsum management systems have been independently audited and certified as conforming with ISO 9001: 2000. The company maintains the quality and leading edge performance of its products and systems through an extensive and on-going programme of research, development and testing, supported by in-house fire, acoustic and system test facilities which are unique amongst building product manufacturers and match the best available anywhere in the UK.
Ceiling products
Perforated gypsum plasterboards. Design and acoustics.
Casoprano
Vinyl faced ceiling tiles. The practical choice.
Rigitone
Acoustic performance data.
Gyprex
Acoustic
Access panels
British Gypsum quality does not stop at the products themselves - CAD and technical support for specifiers; comprehensive on-site Gyptone support and off-site training through three access panels. dedicated product training centres at East Leake near Nottingham, Kirkby Thore in Cumbria, and Erith in Kent, and ex-stock or next day availability through around 4000 stockists nationwide are just a part of a customer support package that has, for many years, set British Gypsum apart in the marketplace. British Gypsum further benefits from being a member of Europes leading gypsum company, BPB plc, which has interests in a wide range of associated building products and provides an extensive pool of knowledge and experience to the benefit of all its member companies.
* Gyproc, Thistle, Gypframe, Glasroc, Arteco and Rawl are all registered trade names of BPB United Kingdom Limited. Isowool is a registered trade name of British Gypsum-Isover Ltd, a joint venture between the insulation division of British Gypsum and Isover Saint-Gobain.
British Gypsum reserves the right to revise product specification without notice. The information given is correct to the best of our knowledge at the time of publication, but it is the users responsibility to ensure it remains current prior to use. The enclosed information should not be read in isolation as it is meant only as guidance for the customer, who should always ensure that they are fully conversant with the products and systems being used and their subsequent installation prior to the commencement of a job. We advise that you read and familiarise yourself with all the information contained in this literature prior to the commencement of the work or specification. For further details refer to our Health and Safety Guidance Sheet which is available on request. For a comprehensive and up to date library of information visit our website at: www.british-gypsum.com
Technical enquiries British Gypsum Limited Drywall Academy Advice Centre East Leake Loughborough Leicestershire LE12 6JT
FM 52358