CoreBrace Brochure Dec 2011
CoreBrace Brochure Dec 2011
CoreBrace Brochure Dec 2011
MAXIMUM EFFICIENCY
Building codes recognize the improved seismic behavior of Buckling Restrained Braced Frames (BRBFs), allowing UP TO A 25% DESIGN LOAD REDUCTION, compared to other commonly used lateral systems. This means: FEWER frames LESS structural weight SMALLER foundations CoreBrace BRBs are engineered to have essentially the same capacity in tension and compression, resulting in less overstrength built into the structure. Additionally, they can be used in single diagonal configurations without design penalties. This means: FEWER braces and connections SMALLER frame columns and beams SMALLER connections to the structure and foundations
LATERAL SYSTEM SEISMIC LOAD COMPARISON
BASE SHEAR COEFFICIENT
0.18 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0.00 0 10 20 30
Buckling Restrained Braced Frame (BRBF) Special Concentrically Braced Frame (SCBF)
LVL 5 W14x145 15'-0" LVL 6 W14x132 15'-0"
GL
CALIFORNIA SITE
30'-0" W16x77
GL
GL
30'-0" W27x281
GL
BR B in
4.
W14x145
W16x77
SS
9.
W27x368
LVL 6 15'-0"
62 SS H SS 1 H H SS 14 SS H
HS
BR B in
7.
W16x77
BR B in
14
W36x395
x0 6x
W40x503
9.
40
50
60
70
80
90
100
LVL 4
11 BR .2 B 5 in
W16x77 W14x283
15'-0"
BR
in
.5
BRBF
12
16
W40x503
.6 25 6 S1 x0
W16x77
BR
LVL 1
13
.2
in
LVL 1
1.0
1.5
PERIOD T (SEC)
2.0
2.5
3.0
3.5
4.0
4.5
x0
.6
SCBF
25
x0
W40x503
.6
25
0.
43
.3
75
5x
0.
37
COMPLETE CONTROL
CoreBrace BRBs are manufactured in our AISC CERTIFIED SHOP, located adjacent to our design offices in West Jordan, Utah. This means: Fabrication constantly monitored to meet the HIGHEST QUALITY STANDARDS Maximum SCHEDULE CONTROL
NON-PROPRIETARY SYSTEM
BRBs are a codified building lateral load resisting system. This means:
Community Financial Services Bank, Benton, KY
CoreBraces superior seismic performance means lower risk with cost savings
Engineering Overview
HIGHLY DUCTILE PERFORMANCE
CoreBrace Buckling Restrained Braces are structural elements composed of a steel core encased in a grout-filled steel tube. The grout/ casing assembly confines the core, increasing its critical load to a point that the axial capacity in compression is only limited by the yield stress of the steel. The concept allows the core to resist the design axial forces utilizing the FULL STEEL STRENGTH while the casing resists flexural buckling. Proprietary Interface Material is used to separate the two resisting systems, with MINIMIZED FRICTION. The result is a high performance brace that DOES NOT BUCKLE.
2000
1000
-1000
1
-4.0 -2.0 0.0 2.0 4.0 6.0
-2000
-6.0
2 3 4
DESCRIPTION Flat () or cruciform shape (+) Square, rectangular or round Casing infill Bolted (shown), welded or pinned
MATERIAL SPECIFICATIONS ASTM A36 ASTM A500 Gr B ASTM A-53 Per CoreBrace specification ASTM A572 Gr 50
In this mechanism the steel core yields in tension and compression, dissipating energy with a SUSTAINED SYMMETRIC HYSTERETIC BEHAVIOUR. As a consequence, the braces act as structural fuses, concentrating all the activity in the plastic range while gussets, beams and columns remain elastic during a seismic event. CoreBrace BRBs use a STABLE END PROJECTION from the casing, which eliminates the need for CJP welds. This provides improved redundancy in the load path and allows for post-event visual inspection.
Brace Deformation ()
BRBF SCBF
TESTING
Independent SUBASSEMBLAGE TEST results show that CoreBrace BRBs exceed the requirements of AISC 341, providing consistent hysteretic behavior during multiple load cycles, at deformations up to 22 times the yield elongation.
Testing of CoreBrace Bolted Lug Braces was performed at the University of Utah, the University of California, San Diego and the National Center for Research on Earthquake Engineering (NCREE) facilities in Taiwan. CoreBrace has successfully tested a brace spliced in the center and installed in two pieces, ideal for retrofit applications. Tested braces: Area: 4.0 in2 to 27.0 in2 Length: up to 31-0
CoreBrace Spliced Plate Braces have been tested at the University of Utah and the University of California, San Diego. Tested braces: Area: 1.5 in2 to 27.0 in2 Length: 15-0 to 19-0
CoreBrace Pinned Braces have been tested at the University of California, San Diego and the National Center for research on Earthquake Engineering (NCREE) facilities in Taiwan. Tested braces: Area: 4.0 in2 to 27.0 in2 Length: 12-0 to 21-2
Testing of CoreBrace Welded Braces has been performed at the University of California, San Diego. Tested braces: Area: 2.0 in2 to 18.0 in2 Length: 21-6
Additionally, to assist with the generation of project documents, CoreBrace will provide CONNECTION DETAILS and REVIT FAMILIES.
Lwc
s/2
d p
Db Dwb
Lwb
Dwb
Lwb
rg
BOLTED LUG
PIN
Dwc
Lwc
Dwc
Lwc
s
Dwsg Dwb Lwb TYP
Lwc
s/
d p
Dwb
Lwb
n B at olts s
Dwb Db
Lwb
rg
Dwg
TYP
PIN
SPLICE PLATE
Lwc
s
Dwsg TYP
Lwc
s/
SET E E N
n B at olts s
Dwc
Lwc
d p
s
Dwsg Dwb Lwb TYP
WELDED
CONSTRUCTION ADMINISTRATION
Db Dwb
Lwb
SPLICE PLATE
d
rg
Dwb
Lwb
Dwg
TYP
The CoreBrace team is ready to assist in the construction BOLTED LUG We pride ourselves on phase of the project when needed. providing PROMPT RESPONSE to any job site inquiries and RFIs and on making every effort to help contractors meet schedule.
PIN
WELDED
SAMPLE PROJECTS
LAPD Headquarters