OVENS
DNO-D Series, Drying Oven With Natural Convection
Routline drying and sterilization applications up to 200C and storage at precisely controlled elevated temperature are the strengths of DNO drying ovens. Hot air ovens are suitable for various applications in the elds of agricultural, and industrial researches for heating, drying, sterilizing and baking in laboratories, hospitals, and industries. PID temperature control provides automatic compansation after load changes, setting changes or door opening for excellent accuracy.
DNO-series
Natural convection heat distribution combines with adjustable air vents to provide excellent uniformity. Double wall construction, berglass insulation and silicon rubber door sealing reduce heat loss and power drain. Stainless steel interior chamber and shelves are corrosion resistant,durable & easy to clean. Power coating exterior is beautiful, durable, and corrosion resistant. Features: Simple keypad input allows easy temperature setting. LED digital display enable users to monitor the chamber temperature at any given time. Visual alarm indicator alerts users of abnormal conditions if the chamber temperature exceeds the setting point by 10C. The temperature can be controlled and maintained to 200C. Ovens feature a see-through window to view contents without opening. Adjustable shelves are included. The temperature stability is 0.5C at 100C; 1.0C at 200C. Optional cable port. Optional gas inlet.
DNO-30
Specications:
Model Convection Working temperature Capacity (liters) Chamber dimen.(mm) Power watts Dimensions (mm) Accessory Optional accessory Power supply
30 W325xD310xH315 700 W425xD420xH610 50 W380xD365xH390 1000 W480xD475xH695
DNO-30
DNO-50
DNO-80
Natural convection Ambient +5C ~ 200C 80 W420xD450xH463 1200 W522xD560xH770
DNO-150
DNO-300
215
OVENS
DFO-36
DFO-80
DFO-150
DFO-240
DFO series units are primarily used in applications needing rapid drying and sterilization. Totally homogenous temperature distribution, rapid dynamic response. This modern range of ovens is available in 4 sizes. DFO series offers excellent uniformity and stability & are used for many applications as Glassware drying, warming, sterilizing, ageing , curing, softening, annealing, preheating and testing , drying slieds. The inner case is constructed from polished stainless steel. All units are provided with wire plated shelves with multi-position settings. All models are with fan assisted air circulation, the chamber ventilation and exhaust vent are easily adjustable. Wide choice of control options is available, PID controller & timer is tted as standard with dual display of measured value and setpoint. Options: 38 mm cable port Gas inlet 5 programs of 8 segments model: 3216CP 4 programs of 16 segments model: 2416P4 RS-232 / 485 communication model: 3216E Specications:
Model Temp. range Temp. constancy Temp. uniformity Temp. control Temp. sensor Heater: Oven Inside Material Timer Window (mm) Safety devices Inside dimensions (mm) Outside dimensions (mm) Capacity (liters) Shelfs Weight
W400xD300xH300 W525xD420xH595 36 34kg W200xH300 Short circuit breaker, over heat protector, sensor abnormality W500xD400xH400 W620xD520xH620 80 2 47kg 60kg W600xD500xH500 W720xD620xH720 150 W600xD500xH800 W720xD620xH1020 240 3 76kg 1100W 1500W sus-304 99hr 59min W200xH500
O
DFO-36
DFO-80
0.1OC 1 C at 100OC PID Thermo couple K 1800W 2200W
DFO-36
DFO-150
O
DFO-240
216
OVENS
MRC High Performance Ovens are engineered to meet the most critical temperature requirements. They are designed for continuous drying operations at temperatures up to 300C. Factory-set over temperature protection prevents control failure from damaging contents and guards against burnout. The Watlow controller provides a 24-step ramp and soak, 0.1C control, multiple levels of operator access and automatic resumption of program following a power failure. Time and temperature are displayed in a three-digit LED readout for fast and accurate setting. In addition, the sealed membrane touch-pad control panel is water and acid resistant. Horizontal air ow provides fast heat-up and recovery and ensures rapid drying. Heated air is continuously circulated by twin turbo blowers. Blowers also circulate air to motor bearings to prolong motor life. Punched stainless steel shelves are adjustable on 1/2 inch centers. Adjustable three air intake and exhaust ports can be opened for fast drying of high-moisture content samples. The 3.5 inch thick wrap-around berglass insulation on all sides minimizes heat loss. A high temperature gasket door seal eliminates air leakage and ensures longer gasket life while being subjected to extreme operational temperatures. This unit includes long-lasting, low-watt density heating elements. It also has adjustable heavy-duty hinges & a door latch that are designed for lifetime service. The HF4 has rugged, welded construction with a double-walled, corrosionresistant type 304 stainless steel interior and a powder-coated exterior.
Model Capacity (liters) Interior dimension (cm) Enterior dimension (cm) Temperature range Temperature uniformity Electrical specications Temperature recovery time Heat-up (min) Shelves HF4-2
133 W52xD50.8xH51 W89xD73.7xH96.5 15C above ambient to 300C +/-1.0C at 110C Volts: 220V Hz:50/60 Watts: 2200 Amps: 12 4 min to reach 110C 10 min to 110C (20 min to 180C) 2 Supplied (8 maximum)
HF4-2
The CE Oven Series incorporates the Sure Load shelf system, triple wall construction, and easy-to-read microprocessor controls. Users can adjust the air exhaust from the chamber without being near the the heat source. Even at operating temperatures of 225C, the outer skin of this unit meets all CE requirements, so workspaces remain cool. The 99 hr 59 min digital timer has an independent control, so its use is optional. Once the timer expires, the heating elements turn off while the blower continues running to cool the samples inside the oven. Whatever the application, these forced air ovens deliver precise uniformity, air distribution and the peace of mind expected from the MRC brand. All of the MRC CE series ovens are CE approved. The CE family is our lastest installment of a product of Constant. Sure Load Shelf Design Non-Tip Shelves Microprocessor Controls Horizontal Air Flow Cool Touch Damper Digital Timer to 99hr & 59 min CE Approval.
Model Capacity (liters) Inside Dimen.(mm) Outside Dimen.(mm) Temperature Range Temp. Uniformity Electrical Spec. Temp. Recovery Time Heat-up (min) Shelving CE3F-2
85 W420xD495xH420 W648xD680xH850 15C above ambient to 225C +/-1.75C at 150C Volts: 220V Hertz: 50/60 Hz Watts: 1100 Amps: 5
CE5F-2
141 W533xD495xH533 W760xD680xH965 15C above ambient to 240C +/-2.0C at 150C Volts: 220V Hertz: 50/60 Hz Watts: 1500 Amps: 6.5
CE3F-2
217
OVENS
PF-Serie, 300C Ovens
PF-30
This modern range of ovens provides a combination of excellent performance & reliability. Increased power and low thermal mass encased bre insulation ensure both fast heat up times & reduced recovery times. Reduced holding power once at set temp., together with the insulation, makes the range economical & outer case temperatures have been signicantly reduced. Both gravity & forced air circulation models are available with a wide choice of control options allowing the most critical performance criteria to be met. Where processes involve the liberation of ammable vapours, a stoving & curing option is available. Also, where processes involve large amounts of water, a moisture extraction option is available.
Features: The outer cases are fabricated from corrosion resistant zinc coated mild steel & nished in two tone hard wearing stoved epoxy/polyester coating. The inner case is constructed from polished stainless steel. All units are provided with non-tilt bright nickel wire plated shelves with multi-position settings for convenient loading and unloading. Adjustable air ventilation The chamber ventilation and exhaust vent are easily adjustable from the front control panel, on all bench top models. Digital temperature control The control module is able to house many variations of digital instrumentation with simultaneous display of measured and set temperature. Microprocessor based PID controllers are tted as standard. Economy and efciency Insulation around the oven chamber utilises totally encased bre material. This material has a very low thermal mass and thermal conductivity, ensuring very efcient insulation. This also ensures reduced holding power, making the units economical to operate once set temperature has been reached. Door action A ush tting door latch with a concealed mechanism is both simple to use & provides a handle when unlatched. The lever action ensures gentle closure. The door seal design includes a newly formulated silicone compound, providing longer life & durability at maximum temp. The design also allows convenient replacement if necessary. Control panel The side mounted control panel avoids damage from accidental spillage. Safety standards All units meet the relevant European health and safety at work legislation & the performance criteria of BS 2648 & DIN 50011. They are manufactured to comply with BS EN 61010: safety standard & also the low voltage & EMC European Directives. Options: Range of over temp. protection systems in accordance with DIN12-880 Part 2. Stoving & curing option available for processes involving liberation of ammable vapours. Timers: Process timers-manual or automatic. Mechanical or electronic time switches. Top access port for independent probe. Lockable door latch. Exhaust fan * Variable speed fan * Inert gas connection * Flow meter & needle valve. Viewing window in door * Interior light. Air inlet lter. Cable entry port * Door switch. Stands & trolleys. Chart recorders. * These options may affect Chamber Uniformity Specications:
Model Max. Temp (OC) (H) Chamber Dimensions (W) (mm) (D) Outside Dimensions (mm) Weight (kg) Shelves Number Supplied Max. Possible Max. Dist load/shelf kg Max load kg Performance Power Rating at 240V (watts) Holding Power* at Max. temp. (watts) Temp. Uniformity* (at Max. temp. as a%) Temp. Stability on/off control (OC) Temp. Stability PID control ( C)
O
PF30
300 300 292 320 470 665 470 28 30 2 3 10 20
PF60
300 400 392 420 570 765 570 66 45 2 5 10 30
PF120
300 500 492 520 670 865 670 128 60 2 9 10 40
PF200
300 750 592 520 920 965 670 230 75 2 15 10 50
Heat up Times* (Mins) 240V Recovery Times* (Mins) Door Open 60sec 240V Air Exchanges
218
OVENS
FD-400/600, 200C Large Capacity Ovens
These ovens - with fan assisted air circulation are widely used in the eld of biochemistry, chemical pharmacy, medical sanitation, agriculture & environment protection, etc. & are available in 430 or 600litre capacities. The ovens are ideally suited for the drying of considerable quantities of glassware or large individual pieces. The ovens will accept a greater number of trays, or without trays can be used for processing large components. Three-dimensional heating technology ensures the solid temperature uniformity in the working chamber. Sound airway structure & gentle airow circulation design. Mirror stainless steel chamber, electro polished stainless steel shelves & toughened glass internal door.
FD-600
Applications: drying of glassware warming sterilising ageing curing burning-in long term stability testing softening
Specications:
Model Control mode Display mode Blow mode Temperature range (C) Temperature adjusting precision (C) Temperature uctuations (C) Temperature uniformity (C) Security function Additional function Capacity (liters) Number of clapboard (piece) Net weight (kg) Inside dimension (mm) Outside dimension (mm) Packing dimension (mm) Power (W) Voltage FD-400
Fuzzy logic control technology LED Bottom vertical airow Ambient +5~200 0.5 (200C) 0.1 2.5 (200C) Upper and lower temperature limit exceeding alarm, independent exceeding guard Timing operation, monitoring timer, power-off recovery, parameter recalling, correction of temperature indicator 430 2 (Maximum 4) 170 W700xD650xH950 W890xD780xH1420 W1010xD900xH1590 3100 AC 220V 50/60Hz 210 W800xD780xH1000 W990xD910xH1470 W1110xD1030xH1640 3700 600
FD-600
219
OVENS
Large Capacity Ovens. Models FX14-2 features 385 liter and FX28-2 793 liter are perfect for high volume sample processing and drying applications including production processes. Precise Temperature Control: Technology. The independent overtemperature protection (DTP) control is user adjustable and provides added security against temperature overshoot. Include a precision microprocessor controller, 99 hr./59 min. electronic timer and true forced air horizontal airow. 90mm of insulation, wrapped in two layers. A chamber door gasket eliminates heated air leakage. The door hinges are user adjustable to maintain a positive seal over the life of the oven. True Horizontal Airow. The blower-assisted airow design facilitates temperature uniformity and fast recovery. A turbo blower and heavy-duty motor combine to direct heated air over the shelves and samples for even, constant drying, curing and baking.
FX14-2
FX28-2
FX28-2 AirFlow Diagram
Features: True horizontal airow provides excellent uniformity and faster heat-up Microprocessor control for precise temperature control Independent Safety Controller 99 hr/59 min Electronic Timer automatically turns off at selected time Adjustable exhaust port controls the rate of drying. Specications:
Model System type Controls/Display Chamber capacity (liters) Temperature range Temperature uniformity High limit control External dimensions (cm) Internal dimensions (cm) Shelves supplied Maximum shelves Shipping weight (kg) Element wattage
Electrical requirements Max. amp draw at 220Vac Power frequency/phase
FX14-2*
Mechanical convection Single setpoint mProc. 385 lit. Amb.+5 to 200C 3C at 110C Yes W94xD86.4xH119.4 W78.74xD63.5xH78.74 3 Shelves 8 Shelves 154 2000 10 50-60Hz/single phase
FX28-2*
Mechanical convection Single setpoint mProc. 793 lit. Amb.+5 to 200C 3C at 110C Yes W94xD86.4xH200 W78.74xD63.5xH157 6 Shelves 16 Shelves 204 4000 19 50-60Hz/single phase * - 2 Denotes 220V
Applications: Batch Testing Sterilizing Electronic Burn-in Aging Tests Glassware Drying Stability Testing
220
Economy
VACUUM OVENS
KF-Series, Vacuum Drying Ovens
The Vacuum Drying Oven well combines vacuum condition with drying heating technique, signicantly reduces boiling point and vapor tension, in order to provide the experiments a dustless, nonvortex, gentle working room. Therefore, it will be convenient to collect, discharge and reuse the vapor. Moreover, because the whole procedure of experiment, like storage, heating, drying, all processes in the vacuum or inert gas chamber, the specimen wont be oxygenated readily. There are Three optional modes of 22L, 47L, and 77L.
KF500
KF400
KF300
Application: It is broadly applied to biochemistry, chemical pharmacy, medical sanitation, agriculture and environment protection, such as the powder drying, baking and sterilizing and disinfection of glass container. It is particularly t for quick drying disposal of thermal sensitive, ssile, oxidizing substance and complex compounds.
KF300
Features: Vacuum electromagnetic valve makes it easy to switch the vacuum pump. Built-in large-scale plate heating design ensures the ne uniformity of temperature in the chamber. Mirror stainless steel chamber. electro polished stainless steel shelves and toughened glass observe window indoor. the luxurious and elegant prole with aesthetic designing. Specications:
Model Temperature range (C) Temperature uniformity Duration to max temperature Range of vacuum degree Capacity (liters) Number of shelves (piece) Net weight (kg) Inside dimension (mm) Outside dimension (mm) Power (w) Voltage
22 1 50 W300xD300xH250 W510xD435xH720 300 75 W350xD350xH385 W560xD485xH845 800 AC 220V 50/60Hz 70 minutes 133mbar (1Torr) 47
KF500
Options: Temperature Programer 4 programs of 16 segments, Model: Eurotherm 2416P4 RS-232/485 comunication. Model: Eurotherm 3216E. Oil vacuum pump. Diaphragh vacuum pump.
KF300
40 ~ 180
O
KF400
40 ~ 200 5 C of set point
KF500
40 ~ 250
80 minutes
221
VACUUM OVENS
Analog
1407-2/1408-2, Small Vacuum Ovens
Vacuum ovens are used for a wide variety of vacuum drying, curing and moisture content testing. Common applications include drying heat sensitive samples, moisture determination, & drying heat sensitive samples under a controlled atmosphere. MRC vacuum ovens are specically designed for unparalleled performance when utilized for these, and other, applications. Since there is no air in the vacuum chamber, heat is transferred from the heating elements
1407-2
to the interior chamber wall, then to the shelves, and nally to the samples. MRC Vacuum ovens maximize conductive heat techniques. To minimize conductivity resistance, ALUMINIUM shelves are provided with all MRC vacuum ovens. The oven chambers are wrapped in high temperature insulation which aids overall performance and promotes energy efciency. MRC offers both standard ANALOG vacuum ovens with mechanical thermostat & Digital PID controlled models. Both ranges include unique design features which enhance the overall performance of the ovens. These features include durable construction with corrosion resistance stainless steel chambers, true vacuum valves, cross-ow ventilation through the oven chamber, and interchangeable door gasket for application specic use. Independent, resettable circuit breakers prevent any electrical overload. Analog Model For Accuracy and Economy The Models 1407-2/1408-2 feature hydraulic thermostats & corrosion resistant stainless steel interior. A 13mm thick tempered glass observation window resists breakage under vacuum & permits easy viewing of the chamber interior. Glass viewing windows are "spring mounted" which allows the door to close squarely, thus ensuring a tight seal around the oven door. Furthermore, the door gasket has a beaded edge which also ensures vacuum integrity. Door gaskets are designed to be easily removable & interchangeable. The standard gasket supplied with all models is made of highly resistant SILICONE rubber. Also available as optional accessories are application specic gaskets. The BUNA-N gasket is available for solvent applications & is limited to a maximum temperature of 125C. The FLOUROSILICON gasket is available for applications involving acids & is limited to a maximum temperature of 200C. Digital Model for Top Performance and Accuracy The Model 1407DIG feature PID (Proportional Integral Differential) controllers. This controller delivers precise temp. stability & repeatability. Dual digital display of setpoint & actual chamber temperature. Specications:
Model Analog Model Digital Chamber Capacity (liters) Temperature Range Temperature Uniformity Heat up time, Minutes Shelves Supplied Outside dimensions(mm) Inside dimensions(mm) Weight Watts/Amps-230Volt Cycle Phase
H565xD420xW362 H229xD305xW229 27Kg 550/2.4 50/60 Hz Single
1408-2
1407-2 1407DIG
16 40-210OC
1408-2 1408DIG
47
3.5OC @ 100OC 5OC @ 200OC 30 minutes to 100OC 2 H640xD622xW440 H305xD508xW305 50Kg 1200/5.2
Options: Temperature Programer 4 programs of 16 segments, Model: Eurotherm 2416P4. RS-232/485 comunication. Model: Eurotherm 3216E. Oil vacuum pump. Oil Free vacuum pump.
1408-2
222
Small/Medium Capacity
VACUUM OVENS
This unit is durably constructed with seamless welds and strong bracing. All vacuum ovens are built with a stainless steel chamber for exceptional durability. We use solid brass vacuum valves with Teon seats to prevent leaks. Our double plenum design resulting in a cool outer surface. The doors on these units have positive latch handles with spring-loaded glass to facilitate a good vacuum seal without hinge binds that shorten the gasket life. A selection of gaskets (for specic applications) and a small bench top footprint increase the versatility of these ovens. Our unique cross-ow ventilation forces inert gas to ll the entire chamber.
1425-2
Cross-Flow Ventilation featured in all Vacuum Ovens Users can choose from 3/8 inch orices or a KF25 tting to withstand heavy use, minimize draw-down time and achieve low vacuum levels. We offer a full line of gaskets to suit applications involving high temperatures, acids, or solvents.
1445-2/1465-2
Features: Cross Ventilation Air Flow Design. Teon Seated Vacuum Valves. Achieve Impressive Vacuum Levels. Sizes Range from 16-125 liter. Built-in Over temperature Protection. Specications:
Model Capacity (liters) Inside dimensions (cm) Outside dimensions (cm) Temperature range Temperature uniformity Electrical specication Temperature control Heat-up (min) Shelves Agency Approval
35 minutes at 100C Volts: 220V Hertz: 50/60 Hz Watts: 750W Amps: 3.5A
1425-2
16 W22.9xD30.5xH22.9 W43xD48xH58
1445-2
45 W30.5xD50.8xH30.5 W52xD71.75xH67.75 10C above ambient to 240C 3.5% of set point Volts: 220V Hertz: 50/60 Hz Watts: 1100W Amps: 5.0A 1C 45 minutes at 100C 3 Supplied UL and CE Approved
1465-2
125 W45.7xD61xH45.7 W66xD79xH81
65 minutes at 100C
223
VACUUM OVENS
Large Capacity
Unique Design. The Model 1495D is a general purpose vacuum oven specially designed for professional and industrial use. The combination of the oven and a ruggedly constructed mobile stand creates an ideal vacuum application station. The stand is designed for mounting a vacuum pump at the base. All vacuum plumbing and KF25 connections are provided (vacuum pump not included). Precision Controllers. The Waltow 981 temp. controller, programmable and microprocessor-based, offers multiple ramp and soak capabilities, including storing and running up to 24 temperature proles. The controls are easily adjustable and the control panel is user friendly. A digital vacuum gauge shows chamber vacuum level in measurements of Torr and m/Torr. The display range is 760 Torr down to 0 mil Torr. A secondary independent high limit controller provides over temperature safety protection. Rugged Construction. High grade stainless steel construction is used for the exterior and chamber interior. Vacuum valves incorporate 3/8 brass orices to withstand heavy use.
1495D
Features/Benets: Large capacity is efficient and accommodating Ramp and Soak Controller Stainless Steel Interior KF40 Fitting Included All stainless steel construction Programmable Controller Digital Vacuum Gauge for accuracy Cross-flow ventilation allows for a dry oxygen free environment. System ready to receive vacuum pump Pannel: Introduced Gas Saturates Chamber Uniformly. Our unique cross-ow ventilation design forces nitrogen or other inert gases to ll the entire chamber. Gas is forced across the greatest distance of the chamber, purging the chamber as it passes over the samples. Corrosion-resistant stainless steel tubing is used for the gas purge piping system. Use this feature to reduce effects of oxidation. The oven chamber is wrapped in high temperature insulation which aids overall performance and promotes energy efciency. Powder coat construction, true vacuum valves and crossow ventilation through the oven chamber enhance total performance. The vacuum oven is secured to a ruggedly constructed mobile stand to create a vacuum pump at the base. Although the oven is not supplied with a vacuum pump, all vacuum plumbing and KF25 connections are provided. Specications:
Model System Type Controls/Display Chamber Capacity (liters) Temperature range Temp. uniformity Heat up (min) High Limit Control Outside Dimen. (cm) Inside Dimen. (cm) Vacuum Gauge Standard Gasket Material Shelves Supplied Maximum Shelves Shipping Weight in kilograms Element Wattage Electrical Requirements: Max. Amp draw at 220Vac Power Frequency/Phase
Vacuum Oven Station Digital mProc. 255 Amb. +15C to 220C 7.0C at 150C 90 minutes at 150C Yes-Independent W92xD114.3xH157.5 W71xD61xH61 Digital-m/Torr Scale Viton 3 Aluminium 7 Shelves 445kg 3500 16 50-60 Hz/ Single Phase
1495D
Aplications: Vacuum drying & curing Moisture determination Out-gassing solids & liquids Aging tests
224
* - 2 Denotes 220V
OVENS
HF2-2
133 W52xD50.8xH51 W89xD73.7xH96.5 15C above ambient to 300C +/-1.0C at 110C Volts: 220V Hz:50/60 Watts: 2200 Amps: 12 4 min to reach 110C 10 min to 110C (20 min to 180C) 2 Supplied (8 maximum)
HF2-2
Shelves
MRC clean air ovens incorporate all the special features needed for high temperature clean room work: an all heliarc-welded type 304 stainless steel interior, two adjustable perforated stainless steel shelves, rapid heat recovery, and two separate LED digital displays for time and temperature that show set point or up-to-the-second process information. The PID (Proportional Integral Differential) controller provides a 24-step ramp and soak, 0.1C control, and multiple levels of operator access. A sealed membrane touch-pad control panel protects the controllers. These units also have three adjustable air intake & exhaust ducts that are easily removed for cleaning & allow the use of either room or recirculated air. A nitrogen inlet port for purging is standard to prevent contamination. MRC clean room ovens are made with 3.5 inches of high-temperature, wrap-around insulation and a high-temperature silicone rubber door seal. Options: Horizontal Air Flow. Encapsulated Insulation. Nitrogen Purging. 24-Step Ramp and Soak PID Controller. Stainless Steel Interior & Durable powder coated exterior paint. Built-in Overtemperature Protection. Hepa lteration (Model CR1).
Model: CR-1, Inert Gas Class 100 Cleanroom Oven, 200OC, HEPA Filter
Model Capacity (liters) Interior dimension (cm) Enterior dimension (cm) Temp. range Temp. uniformity Electrical specications Temp. recovery time Heat-up (min) Shelves CR-1
110 W43.2xD50.8xH51 W89xD73.7xH96.5 15C above ambient to 200C +/-1.0C at 110C Volts: 220V Hertz: Watts: 2200 Amps: 12 4 minutes to reach 110C 10 min to 110C (35 min to 180C) 2 Supplied (8 maximum) Triple Wrap Insulation Interior & Exterior #304 Stainless Steel 2 Door Gakets To Ensure Seal 24-Step Programmable Microprocessor Internal HEPA Filter Strudy Shelves Adjustable Air Intake & Exhaust
CR-1
Horizontal Airow
225
OVENS
CR-Serie, Class 100 Clean Room Ovens
Options: Over-temperature protection to DIN 12-880 class 2 (recommended to protect valuable contents & for unattended operation) HEPA filtered airflow available Digital process control timers & multi segment programmers available Paperless DAQ (Data Acquisition) graphical recorders available Top access port for independent thermocouple Cable access port Viewing window door Through door illumination system Stacking frame to enable units to be stacked one upon another Key-lock door Door switch to cut off power when the door is open Fully customised through wall (flange fitted) designs are available Up to 300,400,500,600OC.
Dimensions Shelf Temp. Heat-up Recovery Max. Temp. Uniformity Shelves Loading Volume Max. time to time to Model Temp. Stability Fitted/ Each/ (liters) Power Internal External (OC) Max. Max. (OC) (OC) Accepted Total (W) O HxWxD(mm) HxWxD(mm) @250 C (mins) (mins) (kg) CR/30 CR/70 CR/130 CR/180 CR/220 CR/330 CR/450 CR/840
250 250 250 250 250 250 250 250 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.3 3.0 3.0 4.0 5.0 5.0 5.0 5.0 5.0 5.0 35 35 35 58 75 80 75 4 4 4 5 4 6 9 310x310x310 310x470x470 550x470x470 770x470x470 610x610x610 655x460x670 655x620x820 895x620x820 1115x620x820 1130x780x850 2/3 2/5 3/9 3/15 3/15 4/8 5/11 6 5 10 20 10 30 10 40 10 50 15 45 15 60 15 75 15 15 30 68 121 170 227 340 450 850 1810 1000 1500 2000 2500 3000 4500 6000 12000 18000
Power Supply
230V single phase 230V single phase 230V single phase 230V single phase single phase single phase or 3 phase 3 phase 3 phase 3 phase
CR/1790 250
Minimum operating temperature approximately ambient plus 200OC Uniformity values are measured in an empty chamber, with vents closed after a stabilisation period Shelf loadings are based on evenly distributed weight
226
DRYING OVENS
Most vapour explosions in ovens occur when materials that can absorb large quantities of solvent are being processed; typical examples being colls & similar electrical equipment, breboard & textiles. Every ammable solvent has a lower & upper ammable limit, & unless the concentration of the solvent vapour is within this range it will not explode. The range widens, for most solvents, with increasing temp. Precautions must be taken to ensurs that no substantial volume of vapour/air mixture within the rarge of aamability can occur in the oven. It is not sufcient to permit an explosive mixture to form and attempt to obtain safety by preventing foreseeable means of ignition. The precautions must be directed towards keeping the concentration of solvent vapour down and this is achieved by permitting only the minimum Quantity of solvent to enter the oven and by ventilating the oven continuously in use, to diluts the solvent vapours emitted to one quarter of the lower ammable limit. The ash-point of a substance is the temperature at which it evolves sufcient vapour to form an ignitable mixture with air when tested under standard conditions. Thus, if the ash point of a liquid is below the temperature of the work room it will give off vapour until (and beyond) the point where the whole room is full of a ammable mixture, or until all the liquid has evaporated. If the ash point is higher than room temperature, then the PF30-SC liquid will never give off enough vapour to form a ammable mixture in the room. Low ash point solvents are thus intrinsically dangerous. However, the choice of a solvent with a high ash point will usually make no difference to the safety of the oven used to evaporate it, since the oven almost Inevitably has a working temperature higher than the ash point. It is still most desirable to choose solvents with the highest possible ash points to reduce danger at the dipping, spraying and other processes prior to the oven. Pre-Treatment: The rst step should be to limit as far as possible the amount of solvent entering the oven at each loading. Particular care is neaded with articles which have been dipped in paint or varnish to give a thicker coating than is usually obtained by spraying. As much drying as possible should be carried out before the articles are added Into the oven. Where the process permits, it is a good practice, both for safety and economy of heat, to allow the load to remain for a short time in a semi-enclosure provided with mechanical exhaust ventilation, so that air at room temperature can remove some of the solvent. This arrangement also has the advantage that dripping in ths oven is reduced, whereby the accumulation of paint and varnish residues in the oven became less of a problem. Ventilation: Reliance on natural convection currents up the chimney is not normally an acceptable method of introducing sufcient fresh air into the oven to prevent a solvent/air explosion mixture forming. The oven should be tted with mechanical exhaust ventilation. It is important that Model PF30-SC PF60-SC PF120-SC PF200-SC the exhaust draught should be applied at O 300 300 300 300 points in the oven where the rate of Max. Temp ( C) evaporation is a maximum, and that there 300 400 500 750 (H) are no dead spots in the oven space 292 392 492 592 Chamber Dimensions (W) where there is Tittle air movement, witn 320 420 520 520 (D) little dilution of the ammable vapours as a (mm) result. In order to improve the temperature 470 570 670 920 (H) distribution and to obtain an even ow of 665 765 865 965 Outside Dimensions (W) air throughout the oven it is normal to have 470 570 670 670 (mm) (D) some form of air recirculatlon. A proportion of the vapour and fume laden air should be Chamber Capacity (liters) 28 66 128 230 extracted through a ue tted with its own 30 45 60 75 Weight (kg) separate exhaust fan. Reliance on spillage of sufcient vapour and fume laden Shelves air through a rotund draught ue from the Number Supplied 2 2 2 2 redrculation system tends to be 3 5 9 15 Max. Possible unsatisfactory. An interlock between the 10 10 10 10 Max. Dist load/shelf kg heat source and the exhaust ventilation is 20 30 40 50 the normal method of ensuring that Max load kg sufcient air is Introduced into the oven for Performance safety. Explosion Relief & Door Fastening: Power Rating at 240V (watts) 1000 1500 2000 2700 Although an oven may be provided with 350 600 800 1250 Holding Power* at Max. temp. (watts) comprehensive precautions, explosions can still occur due to failure of components, O 1.0 1.0 1.0 1.0 Temp. Stability on/off control ( C) inadequate servicing, or deliberate scotching of safety devices. The probability Temp. Stability PID control (OC) 2.0 2.0 2.0 2.0 of fatal or serious injury to workpeople, O 4.5 4.5 4.5 5.5 Heat up Times* 100 C or serious damage to the oven, can be 12 12 12 14 (Mins) 200OC reduced substantially if suitable explosion 25 25 25 30 relief is provided, coupled with adequate 240V 300OC securing of the doors of the oven to pre1 1 1 1.5 100OC vent their becoming missiles in the event of Recovery Times* 2.5 2.5 2.5 3 an explosion. It is recommended that ex(Mins) 200OC 4 4 4 5 O plosion relief panels are tted to all solvent Door Open 60sec 300 C evaporating ovens Irrespective of chamber 240V volume. These notes cover the bare 10,000 10,000 10,000 10,000 Air Exchanges vol (l/h) @ 100OC essentials of the requirements for solvent evaporating ovens used in stpvlng and 360 153 79 44 Air Exchanges (Exchanges/Hour) curing processes.
227
OVENS
LHT 6/60
Options: Cable entry ports . Over temperature protection to DIN 12-880 class 2 (recommended to protect valuable contents & for unattended operation )*. A range of sophisticated digital control & multi segment programmers is available. Optional overtemperature protection recommended for continuous operation & to protect valuable contents. Process timer. RS232! RS485 communications. Viewing window.
Model
Dimensions Temp. Heat-up Recovery Max. Temp. Uniformity time to time to Temp. Stability Internal External (OC) Max. Max. (OC) (OC) O @250 C (mins) (mins) HxWxD(mm) HxWxD(mm)
400 400 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 5.0 50 50 70 10 16 20 10 16 20 10 10(+) 300x300x305 570x830x570 400x400x405 670x930x670 650x480x405 920x1030x670 300x300x305 570x830x570 400x400x405 670x930x670 650x480x405 920x1030x670 300x300x305 570x830x570 400x400x405 670x930x670 650x480x405 920x1030x670
Shelves Volume Max. Weight Fitted/ Power (kg) Accepted (liters) (W)
Power Supply
230V single phase 230V single phase 230V single phase 230V single phase 230V single phase 230V single phase or 3 phase 230V single phase 230V single phase 230V single phase or 3 phase
LHT4/30 LHT4/60
LHT6/120 600
228
3 phase (uses 2 phases & neutral of 380/220V - 415/240V supply) (+) Recovery to 500OC set -pomt
OVENS
Standard features: 4000C, 5000C or 6000C Operating temperatures. 28, 95 & 220 litre capacities. Digital PID temperature control using 301 controller including over- temperature protection. Rear mounted fan & side air guides give horizontal airflow. Manual gas control via needle valves & flowmeters (nickel brass). Corrosion resistant, ferritic grade 430, stainless steel interior with perforated non-tip shelves & runners.
Copper pipe-work with brass flow-meter & solenoid valves . Single side hinged door, with metal heat seal & rubber gas tight seal, closed using none slam lever switch. Suitable for continuous operation (see options*). Double skin construction for cool, safe, outer case. Hard wearing, zinc coated & staved epoxy polyester coated exterior. Options: Automatic gas control (requires a 3508 series programmable controller). Manual electronic gas control using 2x flow-meters & solenoid valves . Stainless steel pipe-work with brass flow-meter & solenoid valves . Stainless steel pipe-work, flow-meter & solenoid valves.
A range of sophisticated digital control & multisegment programmers are available. RS232 / RS485 communications. Fixed or castor mounted floor stands. A range of gas tight high temperature ovens for use with inert atmospheres in a batch production environment.
Model
Dimensions Heat Recovery Max. -up to Temp. time to time Internal External Max. O ( C) Max. HxWxD(mm) HxWxD(mm) (mins) (mins)
400 400 400 500 500 500 600 600 600 50 75 120 50 75 120 50 75 120 10 16 20 10 16 20 10 16 20 305x305x305 455x455x455 880x675x885 1010x880x1120
Shelves Volume Max. Weight Fitted/ Power (kg) Accepted (liters) (W)
Power Supply
230V single phase 230V single phase 230V single phase 230V single phase 230V single phase 230V single phase or 3 phase 230V single phase 230V single phase 230V single phase or 3 phase
610x610x610 1160x1030x1280
Uniformity is measured in an empty chamber with vents closed, after a stabilisation period * Nominal values based upon a representative sample of products
229