Micros 60: Technical Specifications: Smart Hematology

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Resource_307189_a 9/30/03 11:48 AM Page 1

M I C R O S
8 or 16 Parameters

6 0

T E C H N I C A L
Reagents

S P E C I F I C AT I O N S
3 reagents (Diluent, Lysing agent and Cleaner) Integrated reagents during selected cycles 2 lines of 40 alphanumerical characters Single button Startup and Standby operations Software selected cleaning cycles Instrument (Last sample analyzed) Memory Smart Card (optional) (60 patient sample results) Automatic QC Smart Card up to 99 control results, 3 levels, 33 results/level 80 columns dot matrix printer RS 232 output including graphics 16.5" x 14" x 12.5" (H x W x D) 31 lbs. 90 V to 240 V 50 Hz to 60 Hz

WBC, RBC, HGB, HCT, PLT, MCV, MCH, MCHC RBC & PLT histograms MPV, RDW, Lymphocytes (% and #) Monocytes (% and #) Granulocytes (% and #) LMG histogram Open tubes Closed tubes on a 4-position variable sized tube holder Only 10 L of whole blood Automatic sample probe cleaning and rinsing (internally / externally) 60 samples/hour (Open Tube systems) 55 samples/hour (Closed Tube systems) Alphanumerical touch key panel - Patient I.D. - Sequence # Barcode reader (optional) Aperture impedance Counting failure flags Programmable normal limits Pathological flags (WBC, RBC and PLT)

LCD screen

Sample processing Sample Volume

Maintenance

Memory

Throughput

Calibration Quality control

Sample Identification

Printer Interfacing

Measurement principle Flags

Dimensions Weight Electrical power supply

Hemalink Data Management ready

Parameters WBC RBC HGB HCT PLT (Hgb>2g/dl,) PLT (Hgb<2g/dl,)

Error Limits (Absolute or %) 0.3 or < 7.5% (whichever is greater) 0.07 or < 3% (whichever is greater) 0.3 or < 3% (whichever is greater) 2 or < 3% (whichever is greater) 10 or < 10% (whichever is greater) 10 or < 10% (whichever is greater)

Linearity Limits* 0 - 100 0 - 8.0 0 - 24 0 - 70 0 - 2.200 0 - 4000


* V1.6 software version
Subject to technical modifications HAN 340A

SMART HEMATOLOGY

ABX DIAGNOSTICS 34 BUNSEN DRIVE IRVINE CA 92618-4210 PHONE 949.453.0500 888.903.5001 FAX 800.537.4666 abx.com

Resource_307189_a 9/30/03 11:48 AM Page 2

MICROS 60
8 O R 1 6 PA R A M E T E R S F U L LY- AU TO M AT E D A N A LY Z E R

Subject to technical modifications

HAN 340A

Simple and easy to use Closed or open tube sampling Provides fast and accurate results

Resource_307189_a 9/30/03 11:48 AM Page 3

Micros 60 Open Tube

MICROS 60
How can you resist superb Performance and Reliability?
8 or 16 parameters sampling on closed or open tubes 60 samples per hour automatic sample probe cleaning and rinsing single button operator interface only 10 L of whole blood per cycle automatic calibration smart cards for multiple patient sample storage and Quality Control RS 232 computer interface. MICROS 60 combines the accuracy and reliability of ABX technology in a compact and robust instrument for maximum cost effectiveness.

SIMPLE

FLEXIBLE

ECONOMICAL

Automatic and compact

Safe and easy to use

Cost effective

Single button operation


for Start analysis cycle

Sampling on closed
tubes with a 4-position variable sized tube holder (125 or 500 L, 3 or 5 mL)

Only 3 reagents (Diluent,


Lysing agent, and Cleaner)

Single button operation for Startup and Standby modes Completely automated
analysis cycle

Minimal reagent
consumption

No biohazard risk with


closed tubes

Automatic sample
probe cleaning and rinsing

Easy to use software


menus

MICROS 60 Closed Tubes

Resource_307189_a 9/30/03 11:48 AM Page 4

MICROS 60
A complete hematology profile at the touch of a button...

MICROS 8 PARAMETERS

WBC, RBC, HGB, HCT PLT, MCV, MCH, MCHC RBC & PLT histograms
MICROS 16 PARAMETERS

WBC, RBC, HBG, HCT


PLT, MCV, MCH, MCHC MPV, RDW

Lymphocytes Monocytes Granulocytes


(% and absolute count)

WBC, RBC & PLT


histograms

RELIABLE

INNOVATIVE

QUALITY

An instrument you can trust

Integrity with system features such as:

Accurate results with differential screening

Membrane valves
(no pinch valves)

Automatic calibration Automated smart cards


used for : - QC up to 99 samples, 3 levels, 33 results/level - Patient data storage up to 60 results Platelet linearity to 4 million on platelet concentrates

Sampling on 10 L of
whole blood (no pre-dilution required)

Very minimal tubing for fluidics and pneumatics No compressor Mechanical reliability
and safety

Alphanumerical
patient I.D. or Barcode patient I.D. (optional)

Normal limits printed


on patient results