JC International Limited: Certificate of Visual Examination and Mpi

JCI conducted visual examinations and magnetic particle inspections of various lifting equipment on the Monitor Rig for Transocean Support Services in September 2011. Inspector Sunday Anyebe examined king post padeyes, fabricated padeyes, and other lifting equipment and found no defects. Some fabricated padeyes were noted to need future load testing to verify their safe working loads. All inspected equipment was determined to be fit for use at the time of examination.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

JC International Limited: Certificate of Visual Examination and Mpi

JCI conducted visual examinations and magnetic particle inspections of various lifting equipment on the Monitor Rig for Transocean Support Services in September 2011. Inspector Sunday Anyebe examined king post padeyes, fabricated padeyes, and other lifting equipment and found no defects. Some fabricated padeyes were noted to need future load testing to verify their safe working loads. All inspected equipment was determined to be fit for use at the time of examination.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

JCI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

JC International Limited RC 413243


CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

49024 Identification Number Qty

21/09/2011

SUNDAY ANYEBE Description of Equipment

SNT LEVEL II MT, PT & UT

KING POST PADEYE PE 70 1pc King Post Padeye SWL: 10 TE

Date of Next Examination: 20-03-12

LOCATION: STBD KING POST Load Tested By: REEL


MPI METHOD: Wet Visible

LOAD TEST DETAILS Date of Test: Cert No. N/A Not Given

SWL: 10 TE
JOP-020

Proof Load Applied: Not Seen


White Contrast Aid Black Magnetic Ink

SPECIFICATION: BS EN ISO 9934-1:2001, BS 2573

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

PARTS EXAMINED: Entire Body of the Padeyes RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Transocean Support Services

Address of premises where Test / Examination was held: Monitor Rig

We hereby certify that on 21/09/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCIC-020

Cert No.227173

JCI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

JC International Limited RC 413243


CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

49025 Identification Number Qty

21/09/2011

SUNDAY ANYEBE Description of Equipment

SNT LEVEL II MT, PT & UT

KING POST PADEYE PE 71 1pc King Post Padeye SWL: 10 TE

Date of Next Examination: 20-03-12

LOCATION: STBD KING POST Load Tested By: REEL


MPI METHOD: Wet Visible

LOAD TEST DETAILS Date of Test: Cert No. N/A Not Given

SWL: 10 TE
JOP-020

Proof Load Applied: Not Seen


White Contrast Aid Black Magnetic Ink

SPECIFICATION: BS EN ISO 9934-1:2001, BS 2573

TEST PROCEDURE: CONTRAST MEDIA: INDICATOR:

PARTS EXAMINED: Entire Body of the Padeyes RESULTS: No defect as at the time of inspection. Fit for use Name and address of equipment owner: Transocean Support Services

Address of premises where Test / Examination was held: Monitor Rig

We hereby certify that on 21/09/2011 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCIC-020

Cert No.227173

JCI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

JC International Limited RC 413243

VISUAL EXAMINATION AND MPI REPORT FOR FABRICATED PADEYE Report No: 49027
Equipment Name: Equipment ID: Parts Examined: Specification: Location: Comment: Fabricated Padeye PE 900 Entire Body of the Padeye BS EN ISO 9934-1:2001 STBD Main Deck Padeyes needs to be load tested, No Defect Found

Inspectors Name/Qualification: SUNDAY ANYEBE

Signature/Date :

23/09/2011

Client Name: Transocean Support Services

Place Of Inspection: Monitor Rig

Cert No.227173

JCI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

JC International Limited RC 413243

VISUAL EXAMINATION AND MPI REPORT FOR FABRICATED PADEYE Report No: 49029
Equipment Name: Equipment ID: Parts Examined: Specification: Location: Comment: Fabricated Padeye PE 901 Welded Areas BS EN ISO 9934-1:2001, BS 2573 STBD Main Deck This Padeye needs to be load tested

Inspectors Name/Qualification: SUNDAY ANYEBE

Signature/Date :

23/09/2011

Client Name: Transocean Support Services

Place Of Inspection: Monitor Rig

Cert No.227173

JCI

Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

JC International Limited RC 413243

VISUAL EXAMINATION AND MPI REPORT FOR FABRICATED PADEYE Report No: 49030
Equipment Name: Equipment ID: Parts Examined: Specification: Location: Comment: Fabricated Padeye PE 902 Welded Areas BS EN ISO 9934-1:2001, BS 2573 STBD Main Deck This Padeye needs to be load tested

Inspectors Name/Qualification: SUNDAY ANYEBE

Signature/Date :

23/09/2011

Client Name: Transocean Support Services

Place Of Inspection: Monitor Rig

Cert No.227173