0% found this document useful (0 votes)
39 views

International Limited: Certificate of Visual Examination

This document provides 3 certificates of visual examination from JC International Limited certifying that 3 pieces of lifting equipment were examined on 17/06/2012 and found to be fit for use with no defects. The examined equipment included 2 hydraulic tuggers and 1 wire rope sling. Each certificate provides details of the equipment, its specifications, the parts examined, and certification by the inspector that no defects were found.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views

International Limited: Certificate of Visual Examination

This document provides 3 certificates of visual examination from JC International Limited certifying that 3 pieces of lifting equipment were examined on 17/06/2012 and found to be fit for use with no defects. The examined equipment included 2 hydraulic tuggers and 1 wire rope sling. Each certificate provides details of the equipment, its specifications, the parts examined, and certification by the inspector that no defects were found.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

JCInternationalLimited

RC.413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 1370 Identification Number Qty

Date of Examination 17/06/2012

Examiner KELVIN OSUJI TARE WT SWL GROSS WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT Proof Load Applied Date of next
Examination

Description of Equipment

HYDRAULIC TUGGER
TT 3169-AJ-01 1pc

Hydraulic Tugger winch c/w 16mm X 150mtrs non rotating wire rope with ferrule secured thimble eye and shur-loc eye hook on one end and other end secured

N/A

4t

N/A

N/A

16-12-12

LOCATION: ON DECK
SPECIFICATION : BS MA 31/ISO 3078, ISO 4309 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection Fit for use

Name and address of equipment owner: EMAS

Address of premises where Test / Examination was held: LEWEK TOUCAN

We hereby certify that on 17/06/12(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI

Doc No: JCI-C-V-01

JCInternationalLimited
RC.413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 1371 Identification Number Qty

Date of Examination 17/06/2012

Examiner KELVIN OSUJI TARE WT SWL GROSS WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT Proof Load Applied Date of next
Examination

Description of Equipment

HYDRAULIC TUGGER
TT 3169-AJ-02 1pc

Hydraulic Tugger winch c/w 16mm X 150mtrs non rotating wire rope with ferrule secured thimble eye and shur-loc eye hook on one end and other end secured

N/A

4t

N/A

N/A

16-12-12

LOCATION: ON DECK
SPECIFICATION : BS MA 31/ISO 3078, ISO 4309 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection Fit for use

Name and address of equipment owner: EMAS

Address of premises where Test / Examination was held: LEWEK TOUCAN

We hereby certify that on 17/06/12(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI

Doc No: JCI-C-V-01

JCInternationalLimited
RC.413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 1372 Identification Number Qty

Date of Examination 17/06/2012

Examiner KELVIN OSUJI TARE WT SWL GROSS WT

Qualifications LEEA, SNT LEVEL II MT, PT & UT Proof Load Applied Date of next
Examination

Description of Equipment

WIRE ROPE SLING APL/11/957 1pc 44mm X 5mtrs X single legged sling c/w master link assembly at one end and hook other end N/A 24t N/A N/A 16-12-12

LOCATION: ON DECK
SPECIFICATION : BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection Fit for use

Name and address of equipment owner: EMAS

Address of premises where Test / Examination was held: LEWEK TOUCAN

We hereby certify that on 17/06/12(date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination
Revision No: 01

Name of Inspector: KELVIN OSUJI

Doc No: JCI-C-V-01