Vigilon Fire Detection: Section 5
Vigilon Fire Detection: Section 5
Vigilon Fire Detection: Section 5
Section 5:
by Honeywell
SECTION 5: page
Section 5.1:
by Honeywell
Vigilon
SECTION 5: page 5
5 . : V Ig IlON FI r E DETECTION
by Honeywell
The feature-packed Vigilon analogue addressable fire detection and alarm system from Gent offers medium to large sized building Vigilon offers a degree of system sophistication that has not previously been available and incorporates a host of features designed to make it the simplest system to install, configure and use. As well as providing the user with clear comprehensive information in the event of a fire, Vigilon additionally provides an entire historic log of the systems management information. Should a system fault occur a detailed explanation is shown and the user can at any time navigate through the faults history.
Repeat Panel
Spur
T-breaker
Alarm Sounder
Interface Units
Beam Transmitter
Beam Receiver
Loop 1
Node
Secure Fibre Optic Loop 2 Loop 3 Domain Loop 4 (Max 200 panels per system)
Loop 1
ACU
SECTION 5: page
System Architecture
SECTION 5: page
5 . : V Ig IlON FI r E DETECTION
by Honeywell
1 3 5 7
The Power of Vigilon Supports the largest number of fire detection and alarm products on the same 2 cables with soft or SAFE (Soft Addressed Firmware Encoded) addressing options. Minimise False Alarms The combined power of S-Quad and the Vigilon panel provides quick, intelligible decision making. The S-Quad dual angle optical sensor recognises a clear distinction between smoke and steam. rapid Fire Detection The 4 separate sensing elements in the
S-Quad, including CO, can be set with individual sensitivity levels and sensor states can be programmed for different time periods to suit all applications and environments. Cost Savings Cable runs are shorter. 2 core costs less than 4 core. Overall cable costs are normally 30% less than other systems. Create Seamless Network Connect up to 200 panels together and retain control on large or complex sites. Also, new buildings or extensions are easily accommodated onto the existing system. Customise your Fire Plans Evacuating public areas or production
lines is disruptive and costly. Vigilon Compacts powerful software gives you flexibility. Areas throughout the building can be sectored to give an evacuate or alert signal on alarm, or can be configured with pre-set delays. Safe Evacuation of a fire. loop powered sounder/strobe Loop powered sounder/strobes save on cabling and interface costs whilst ensuring compliance with the Disability Discrimination Act 1995. Built-in high intensity flashing strobes warn those with hearing difficulties of a potential fire hazard now a legal requirement in all public buildings. Voice messaging capability through the sounder
Clear Information An 8-line by 40 character display means the user is not limited in describing the position or nature of an emergency. A clear backlit LCD display reduces confusion and speeds response. Integrated Voice and graphics Systems Vigilon may be integrated with Gents Vigilon Voice evacuation system, or connected to Supervisor, a graphic display for single point control and monitoring.
SECTION 5: page
Vigilon 1-6 loop control panels can accommodate up to 200 devices on each loop. The panel is available with 24 or 72 hour standby facility. Advanced networking options allow multi-domain networks of up to 250 panels. Vigilons backlit 8-line by 40 character display presents clear indication of fire or fault locations. To meet the requirements of BS 5839 Part 1: 2002 the panel also has separate zonal indication. This comprises 32 fire LEDs which give an overview indication at a glance without the need for manual intervention by fire fighters.
TEChNICAl SPECIFICATION Type Max No of Loops Loop Capacity Batteries Battery Standby Approx Weight Operating Temperature Relevant Standard Cable Entry Approvals Control panel 4 200 2 x 12V @12Ah 24 hours standby + 30 minutes alarm upgradeable to 72 hours standby + 30 minutes alarm 16.5 Kg 0C to 45C EN54 Parts 2 & 4 Top and rear knockins LPCB approval to EN 54 Parts 2 & 4 pending Control panel 6 200 4 x 12V @ 12Ah 72 hours standby + 30 minutes alarm 16.5 Kg 0C to 45C EN54 Parts 2 & 4 Top and rear knockins LPCB approval to EN 54 Parts 2 & 4 pending
The standard Vigilon Panel has 24 hour battery standby and up to 4 loops and a network card. The enhanced panel can offer 6 loops and a network card and up to 72 hour battery standby. Fire to plans can be tailored project
precisely
meet
requirements.
B 59 09
C 5 2
OrDEr CODES
EN54 Control Panels 1-4 Loop Panel with 1 Loop Card 1-6 Loop Panel with 1 Loop Card Additional loop Network Card Fibre Net Stainless Steel Door for Vigilon Main Control Panel Vigilon Main control panel flush mounting kit VIG-FLUSH-SS
For existing systems to BS 5839, compatible panels are still available for expansion. Contact Gent for details.
SECTION 5: page 9
Section 5.2:
by Honeywell
Vigilon Compact
SECTION 5: page
by Honeywell
Vigilon Compact analogue addressable 1-2 loop panels offer small to medium sized building owners the unique system functionality of Vigilon with the very best in control panel aesthetics stainless steel door options are available to provide a discreet and luxurious feel in upmarket office environments. The introduction of innovative design features into this panel means that the wall space needed to mount the panel is now 60% smaller than a standard Vigilon installation. Vigilon Compact analogue addressable panels fully comply with EN54: Parts 2 & 4 and can be specified with 1 or 2 detection loops, each capable of accommodating up to 200 Vigilon devices including repeat panels, interfaces, manual call points and S-Quad sensor/sounder/strobes. Gents innovative new S-Quad is a combined multi-sensor range with speech, sounder and strobe in one intelligent unit. Fully compatible with Gents S-Cubed alarm devices (offering sound, speech or strobe effects in combination), Vigilon Compact also offers the familiar advantages of combined sensor-sounders and loop powered beam detection with integral short circuit isolators fitted into every loop device.
Additional features
l l l l
Vigilons powerful software allows the fire alarm system to be configured to meet the fire alarm needs of the building Combining the proven reliability of the Vigilon range of sensors and true analogue sensing keeps false alarms to a minimum Alarm sound levels can be increased by simply replacing a sensor with a sensor/sounder, saving costly additional wiring To meet the requirements of BS 5839-1: 2002 the Vigilon Compact is supplied with separate zonal indication, visible at access level 1. This comprises 32 fire LEDs (secret till lit) which enables at a glance overview indication, without the need for manual intervention by fire fighters
SECTION 5: page 2
MCP
A4 Mimic Display
System Sounder
Beam Transmitter
Beam receiver
MCP
Note: Speech and standard tone sounders can both be used on a system to meet site requirements, but should not be mixed within an alarm zone.
SECTION 5: page
by Honeywell
1 3
Compact size The introduction of innovative design features into this panel means that the wall space needed to mount the panel is now 60% smaller than a standard Vigilon installation. The power of Vigilon Supports the largest number of fire detection and alarm products on the same 2 cables with soft or SAFE (Soft Addressed Firmware Encoded) addressing options. Minimise false alarms The combined power of S-Quad and the Vigilon Compact panel provides quick, intelligent decision making. The S-Quad dual angle optical sensor recognises a clear distinction between smoke and steam. rapid fire detection The 4 separate sensing elements in the S-Quad, including CO, can be set with individual sensitivity levels and sensor states can be programmed for different time periods to suit all applications and environments.
5 7
Cost savings Cable runs are shorter. 2 core costs less than 4 core. Overall cable costs are normally 30% less than other systems. Customise your fire plans Evacuating public areas or production
lines is disruptive and costly. Vigilon Compacts powerful software gives you flexibility. Areas throughout the building can be sectored to give an evacuate or alert signal on alarm, or can be configured with pre-set delays. Safe evacuation of a fire. loop powered sounder/strobe Loop powered sounder/strobes save on cabling and interface costs whilst ensuring compliance with the Disability Discrimination Act 1995. Built-in high intensity flashing strobes warn those with hearing difficulties of a potential fire hazard now a legal requirement in all public buildings. Voice messaging capability through the sounder
Clear information An 8-line by 40 character display means the user is not limited in describing the position or nature of an emergency. A clear backlit LCD display reduces confusion and speeds response. Compliance with the relevant industry standards GENT are LPCB approved for both systems and products and Vigilon Compact complies with BS/EN standards.
SECTION 5: page 4
A one to two loop panel accommodating devices other Panels. Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and total system management. LCD display of allows fire or clear fault
Vigilon Compact Control Panel
TEChNICAl SPECIFICATION Type Loop Capacity Networking Capacity Ingress Protection Approx Weight Operating Temperature Relevant Standards Batteries Battery Standby Supply Voltage Power Consumption Cable Entry Auxiliary Contacts Sounder Circuits Monitored input Communication ports Approvals Pending Control panel 200 Upto 32 panels IP31 16.6 Kg (with batteries) 0oC to +45oC EN54 Pt 2 & 4 2 x 12V @ 12 Ah 24 Hours + 30 minutes alarm 216V 253V 50Hz 140 W Top and rear knockins Programmable to activate on Fire, Fault or Disablement. (1 x SPCO 1 x DPCO) 2 circuits @ 250mA each 1 input which is programmable to perform a logical action via a command build 2 x RS485, 1 x RS232 selectable functions LPCB
up
per
loop
indication location.
Site specific fire plans can be programmed to meet the evacuation building. needs of the
Dimensions (mm)
OrDEr CODES
Control Panel LCD Repeat panel Flush fixing frame Additional Loop card COMPACT-24-N COMPACT-RPT COMPACT-FLUSH COMPACT-LPC COMPACT-NC Optical only sensor Stainless Steel Options: Stainless steel door Stainless steel flush frame COMPACT-FLUSH-SS VIG-RPT-DOOR-SS S4-715 40
SECTION 5: page 5
Repeat Panel
by Honeywell
A repeat panel repeats all information provided to the main control panel and provides mains control functions. The repeat panel is connected directly to the loop but requires a mains supply to run its battery backed power supply.
Dimensions (mm)
40
OrDEr CODES
Repeat Panel Repeat panels require a first fix Stainless steel door VIG-RPT-1ST-FIX VIG-RPT-DOOR-SS VIG-RPT
0
SECTION 5: page
The LCD repeat panel indicates Fire, Fault and Disablement information on a 40 character display, either directly as events occur or by accessing the logs via dedicated keys. A maximum of 4 Repeat Panels can be connected to a Vigilon Compact control panel.
TEChNICAl SPECIFICATION Type Ingress Protection Supply Voltage LCD Repeat Panel (Indication Only) IP30 21 30V dc Approx 30 mA 0.75 Kg 0oC to +45oC 1x RS485 to communicate with the main control panel Top and rear knockins N/A
Power Consumption Approx Weight Operating Temperature Communication ports Cable Entry Approvals Dimensions (mm)
20
49
Wiring Details lCD repeat Panel (indication only) Max Cable length 000M
One lCD repeat panel can be powered from the control panel, additional repeat indicators must be powered from an additional power supply.
rS 45 24Vdc
OrDEr CODES
LCD Repeat panel COMPACT-RPT
The communication link to the panel is monitored, so if power to the repeat indicators fails the fault will be reported at the control panel.
SECTION 5: page
Mimic Panels
by Honeywell
The A2 and A4 Mimic Panels provide a pictorial representation of the buildings layout allowing rapid indication of fire location. The mimic panels have a selection of programmable LEDs onto which a CAD drawing of the site is overlaid. Alternatively a zonal overlay kit may be used. Overlays are easily updated if site details alter.
A2 Mimic
TEChNICAl SPECIFICATION Type Max Quantity per Loop Batteries Battery Standby Approx Weight Operating Temperature Relevant Standard Cable Entry Load Factor 3 Top conduit knockins A2 Mimic 4 12V @ 7Ah 20 Kg A4 Mimic 4 12V @ 7Ah Display 2.3 Kg, Control panel 10.4 Kg 0oC to 45oC BS 5839: Part 4 + EN54: Part 2 & 4 Rear 3
B 0 0
C 90
A4 Mimic Display
OrDEr CODES
A4 Mimic Panel A4 Zonal Mimic A2 Mimic Panel B C A2 Zonal Mimic VIG-MIM-A4 VIG-ZONE-A4 VIG-MIM VIG-ZONE
SECTION 5: page
Notes