10 Sample Preparation

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

10 Sample Preparation

SAMPLE PREPARATION
GLASSWARE
Liquid Chromatography Columns
These have a coarse glass frit at the bottom end, and come with or without PTFE stopcock. Also available without frit; please call for information. Description 10 mm ID x 300 mm Glass Column with Frit 10 mm ID x 300 mm Glass Column with Frit and Stopcock 19 mm ID x 400 mm Glass Column with Frit and Stopcock 22 mm ID x 400 mm Glass Column with Frit and Stopcock Item No. AUC476310 AUC477310 AUC477419 AUC477422

SOLID PHASE EXTRACTION


Liquid Chromatography Column Solid Phase Extraction cartridges from KONIK provide fast and ecient sample clean-up and concentration prior to analysis. Our cartridges use medical grade polypropylene tubes, porous polyethylene frits, and highly reproducible sorbents. All of our SPE syringe cartridges are equipped with male Luer tips, for versatility in connections and processing.

Choosing the Proper Packing Type


Reversed Phase - C18, C8, C4, C2 and Phenyl bonded phases are available and oer a variety of selectivities. Non-polar to moderately polar compounds in a polar matrix are retained by reversedphase sorbents. Reversed-phase packings require conditioning with an organic solvent followed by an aqueous solvent prior to use. Elution of moderately polar compounds is often accomplished with mid-polarity solvents while non-polar compounds require less polar solvents. Normal Phase - Silica, Florisil, Amino, Cyano, Diol and Alumina are usually used to retain polar compounds from non-polar matrices. Conditioning is carried out with a non-polar solvent. Elution is accomplished with more polar solvents. Compounds with pH basic functional groups are readily retained by silica. However, very polar compounds such as carbohydrates can be irreversibly retained on silica surface. In this case, a bonded and mid-polarity phase such as Diol or Amino is a better choice. Ion Exchange - Strong anion (SAX) and cation (SCX) exchangers are available. Anions and cations are retained on the corresponding resin by exchanging the anion or cation in the buers, 0.1 M - 0.5 M, or by changing the pH of elution solvent such that the sample compound is no longer charged. These resins are silica based and lose some exchange capacity with increasing organic solvent content in the sample. SPE Cartridges

Cap. 10: 2

Konik-Tech

SAMPLE PREPARATION
General Extraction Protocols
Reversed Phase
Rinse packing bed with 3 - 5 mL methanol. Rinse with 3 - 5 mL water or buer. Do not let packing dry. Apply sample solution to the top of the packing bed. Push or draw through the bed at 1-5 mL/min. Collect sample for analysis if desired compound has passed through the bed without being retained. If desired compound was retained, wash o weakly retained interfering compounds with a polar solvent. Elute desired compound with 1 -2 mL of non-polar solvent and collect for analysis.

Normal Phase
Rinse packing bed with 3 - 5 mL of a non-polar solvent. Do not let packing dry. Apply sample solution to the top of the packing bed. Push or draw through the bed at 1-5 mL/min. Collect sample for analysis if desired compound has passed through the bed without being retained. If desired compound was retained, wash o weakly retained interfering compounds with a non-polar solvent. Elute desired compound with 1 - 2 mL of polar solvent and collect for analysis.

Ion Exchange
Rinse packing bed with 5 mL deionized water or low-ionic strength buer. Apply sample solution to the top of the packing bed. Push or draw through the bed at 1-2 mL/min. Collect sample for analysis if desired compound has passed through the bed without being retained. If desired compound was retained, wash o weakly retained interfering compounds with deionized water or low-strength buer. Elute analyte with 1 - 5 mL of a high salt concentration solution, or change elution buer pH so analyte is no longer ionized.

Reverse Phase SPE Cartridges, Non-Polar


Description C18 (ODS) C18, 100 mg/ 1 mL C18, 200 mg/ 3 mL C18, 500 mg/ 3 mL C18, 500 mg/ 6 mL C18, 1000 mg/ 6 mL C8 (Octyl) C8, 100 mg/ 1 mL C8, 200 mg/ 3 mL C8, 500 mg/ 3 mL C8, 500 mg/ 6 mL C8, 1000 mg/ 6 mL Phenyl Phenyl, 100 mg/ 1 mL Phenyl, 200 mg/ 3 mL Qty Item No.

100/pk 50/pk 50/pk 50/pk 30/pk

AUC186311 AUC186312 AUC186313 AUC186314 AUC186315

100/pk 50/pk 50/pk 50/pk 30/pk

AUC186321 AUC186322 AUC186323 AUC186324 AUC186325

100/pk 50/pk

AUC186341 AUC186342

SPE Cartridges

www.konik-group.com

Cap. 10: 3

SAMPLE PREPARATION
Non-Silica SPE Cartridges
Description Alumina A Alumina A, 500 mg/ 3 mL Alumina A, 500 mg/ 6 mL Alumina A, 1000 mg/ 6 mL Alumina B Alumina B, 100 mg/ 1 mL Alumina B, 500 mg/ 3 mL Alumina B, 500 mg/ 6 mL Alumina B, 1000 mg/ 6 mL Alumina N Alumina N, 500 mg/ 3 mL Alumina N, 500 mg/ 6 mL Alumina N, 1000 mg/ 6 mL Florisil Florisil, 100 mg/ 1 mL Florisil, 200 mg/ 3 mL Florisil, 500 mg/ 3 mL Florisil, 500 mg/ 6 mL Florisil, 1000 mg/ 6 mL Qty Item No.

50/pk 50/pk 30/pk

AUC186463 AUC186464 AUC186465

100/pk 50/pk 50/pk 30/pk

AUC186471 AUC186473 AUC186474 AUC186475

SPE Cartridges

50/pk 50/pk 30/pk

AUC186483 AUC186484 AUC186485

100/pk 50/pk 50/pk 50/pk 30/pk

AUC186491 AUC186492 AUC186493 AUC186494 AUC186495

Cap. 10: 4

Konik-Tech

SAMPLE PREPARATION
Normal Phase SPE Cartridges, Polar
Description Silica Silica, 100 mg/ 1 mL Silica, 200 mg/ 3 mL Silica, 500 mg/ 3 mL Silica, 500 mg/ 6 mL Silica, 1000 mg/ 6 mL Diol Diol, 100 mg/ 1 mL Diol, 200 mg/ 3 mL Diol, 500 mg/ 3 mL Cyano (CN) Cyano, 100 mg/ 1 mL Cyano, 200 mg/ 3 mL Cyano, 500 mg/ 3 mL Cyano, 500 mg/ 6 mL Amino (NH2) Amino, 100 mg/ 1 mL AUC186371 Amino, 200 mg/ 3 mL AUC186372 Aminol, 500 mg/ 3 mL Amino, 500 mg/ 6 mL AUC186374 Amino, 1000 mg/ 6 mL Qty Item No.

100/pk 50/pk 50/pk 50/pk 30/pk

AUC186361 AUC186362 AUC186363 AUC186364 AUC186365

100/pk 50/pk 50/pk

AUC186391 AUC186392 AUC186393 SPE Cartridges

100/pk 50/pk 50/pk 50/pk

AUC186381 AUC186382 AUC186383 AUC186384

100/pk 50/pk 50/pk AUC186373 50/pk AUC186375

30/pk

Ion Exchange SPE Cartridges


Description SAX SAX, 100 mg/ 1 mL SAX, 200 mg/ 3 mL SAX, 500 mg/ 3 mL SAX, 500 mg/ 6 mL SAX, 1000 mg/ 6 mL SCX SCX, 100 mg/ 1 mL SCX, 200 mg/ 3 mL SCX, 500 mg/ 3 mL Qty Item No.

100/pk 50/pk 50/pk 50/pk 30/pk

AUC186411 AUC186412 AUC186413 AUC186414 AUC186415

100/pk 50/pk 50/pk

AUC186421 AUC186422 AUC186423

www.konik-group.com

Cap. 10: 5

SAMPLE PREPARATION
VACUUM MANIFOLDS
12 and 24-port manifolds Glass chamber for visual monitoring Accepts standard male luer devices Vacuum manifolds allow the processing of multiple samples simultaneously. Manifold systems come complete with components shown below. Includes polypropylene needles; stainless steel or PTFE needles are available separately. Glass chamber Vacuum valve and gauge Polypropylene lid Stopcock valves Collection rack plates Support posts for collection racks Retaining clips for collection racks Lid legs Manifold inlet caps Polypropylene needles

Vacuum Manifold SPE Cartridges not included

Description Manifolds 12 Position Vacuum Manifold, Complete 24 Position Vacuum Manifold, Complete Accessories for 12 Position Vacuum Manifold Glass Chamber Cover with Gasket & 12 Stopcocks Gaskets, 2/pk Vacuum Valve, Gauge and Glass Block Needles, Polypropylene, 12/pk Stopcocks, 12/pk

Item No.

AUC61000 AUC61200

Needles: Stainless steel, polypropylene, PTFE with control valve

AUC61002 AUC61003 AUC61004 AUC61006 AUC61019 AUC61015

Cap. 10: 6

Konik-Tech

SAMPLE PREPARATION
MININERT VALVES & REACTION VIALS
Mininert Valves
These are unique push-button PTFE vial closures featuring inertness and syringe access without exposure of the vial contents. When used with a glass vial, only PTFE and glass are in contact with the sample. A silicone rubber gasket above the PTFE valve stem (isolated from the contents) provides a seal for the needle and prevents leakage or exposure of the contents during sampling. Push the green button to open, insert the needle and take sample, withdraw the needle, then push the red button to close. The needle seal septum may be replaced as needed with the valve closed to avoid exposing contents. Mininert Valves can be used up to 105C. 12/pk. Description 13 mm Screw Cap Mininert Valve 15 mm Screw Cap Mininert Valve 18 mm Screw Cap Mininert Valve 20 mm Screw Cap Mininert Valve 24 mm Screw Cap Mininert Valve 20 mm Crimp Cap Mininert Valve Replacement Septa, 50/pk Septum Installing Tool, each Thread Size 13-425 15-425 18-400 20-400 24-400 NA NA NA Item No. AUC614158 AUC614160 AUC614161 AUC614170 AUC614163 AUC614250 AUC644350 AUC644850 Closed Open

AUC614163

Mininert Valves for use with Miniature Tubing


These are now available with 1/4-28 threads and can be used with Cheminert and other similar miniature connectors to create an almost endless number of piping and plumbing combinations. They are quick-acting and tight-sealing and are suitable for low-pressure applications requiring positive, on/o uid control. Description 1/4-28 Male to Mininert 1/8 Male NPT to Mininert 1/4-28 Female to Mininert 1/8 Female NPT to Mininert 1/4-28 Male to 1/4-28 Male Mininert 1/4-28 Female to 1/4-28 Female Mininert Qty each each each each each each Item No. AUC631201 AUC631202 AUC631203 AUC631204 AUC631205 AUC631206

AUC614250

Reaction Vials
These are useful for micro and semi-micro scale reactions or concentration work. The vials have thick walls, conical tapered interiors and come complete with PTFE-faced silicone liners and openhole screw caps. Vials have graduation marks (except 0.1 and 0.3 mL). Made from borosilicate glass. 12/pk. Description 0.1 mL Reaction Vials 0.3 mL Reaction Vials 1.0 mL Reaction Vials 3.0 mL Reaction Vials 5.0 mL Reaction Vials 10.0 mL Reaction Vials Thread Size 8-425 13-425 13-425 20-400 20-400 24-400 Item No. AUC099400 AUC099410 AUC099420 AUC099430 AUC099440 AUC099450

AUC631201

Reaction vials are also available in amber.

Reaction Vials, 5 mL and 1 mL

www.konik-group.com

Cap. 10: 7

SAMPLE PREPARATION
SYRINGE FILTERS, DISPOSABLE SYRINGES
Syringe Filters
KONIK oers a wide range of syringe lters for most of your sample clean up applications. Filter housings are made from polypropylene and have luer hubs to t all luer lock syringes. Two membrane materials are available; nylon (hydrophilic) for general ltration of aqueous samples and many solvents, and PTFE for gases, air virtually all solvents, and highly corrosive acids and bases. PTFE can be used with aqueous samples by pre-wetting with methanol. 4 mm size - Low sample hold-up; hold up is less than 10 l. 100/pk 17 mm size - For general laboratory sampling. Filters have higher sample capacity than the 4 mm size. Maximum pressure for ltering is 5 bar (75 psi). 100/pk 30 mm size - For all around lab use. The 30 mm diameter allows greater through-put when hold-up of some sample is not critical. Maximum pressure is 5 bar (75 psi). 100/pk Description 4 mm Nylon Filter, 0.2 micron 4 mm Nylon Filter, 0.45 micron 4 mm PTFE Filter, 0.2 micron 4 mm PTFE Filter, 0.45 micron 17 mm Nylon Filter, 0.2 micron 17 mm Nylon Filter, 0.45 micron 17 mm PTFE Filter, 0.2 micron 17 mm PTFE Filter, 0.45 micron 30 mm Nylon Filter, 0.2 micron 30 mm Nylon Filter, 0.45 micron 30 mm PTFE Filter, 0.2 micron 30 mm PTFE Filter, 0.45 micron Item No. AUC189000 AUC189001 AUC189002 AUC189003 AUC186502 AUC186503 AUC186500 AUC186501 AUC186055 AUC186054 AUC186057 AUC186058

Syringe Filters

Disposable Syringes
These disposable syringes are useful for sample preparation, especially when used with our syringe lters. Syringes are made from polypropylene and polyethylene and are silicone-free. Extractables are minimized compared with rubber-tipped plunger syringes. Syringes are individually wrapped in sterile peel packs. 100/pk. Description 3 mL Disposable Syringe 5 mL Disposable Syringe 10 mL Disposable Syringe 20 mL Disposable Syringe Item No. AUC186603 AUC186605 AUC186610 AUC186620

Disposable Syringe

Cap. 10: 8

Konik-Tech

SAMPLE PREPARATION
SAMPLE CONCENTRATION, EVAPORATORS
Adjustable Mini-Vap
This is a versatile concentrator/evaporator for use with a single container. Adjustable design allows use with any size vessel from mini-vial to 250 mL beaker. It is nickel-plated for resistance to solvents and dilute acids, and comes with instructions. Description Adjustable Mini-Vap (Single) Item No. AUC201001

6-Port Mini-Vap
This concentrator/evaporator handles up to six miniature vials or containers simultaneously. It comes with six stainless steel needles, a nickel-plated needle valve, and 3 feet of plastic tubing. The needle valve allows ne control of the nitrogen or dry air ow for the evaporator. Instructions are included. Description 6-Port Mini-Vap Replacement Parts 4 Stainless Steel Luer Needles, 6/pk Spare Luer Lock Adapters, 6/pk O-Ring Seal, 6/pk Plastic End Caps, 100/pk Item No. AUC201006 AUC201001

AUC201007 AUC201114 AUC201115 AUC205122

AUC201006

www.konik-group.com

Cap. 10: 9

SAMPLE PREPARATION
NEW HAMILTON SOFTGRIPTM PIPETTES
Best overall accuracy and precision Fully autoclavable Ergonomic by design Made in the U.S.A. The new SoftGrip boasts an enlarged ejector button, dual needle volume indicator, slimmer ejector sleeve, redesigned plunger button, and a more stain resistant grip. These modications have enhanced the functionality of the SoftGrip while maintaining the principles of quality, ergonomics, and functionality that made the SoftGrip popular. Fixed volume pipettes

Fixed Volume Pipettes - 5 l - 1 mL


Volume 5 l 10 l 25 l 50 l 100 l 200 l 250 l 500 l 1 mL Color Steel Blue Purple Forest Green Sandstone Violet Mustard Burnt Orange Olive Green Sky Blue At 100% of Pipette Volume Accuracy Precision within +/- % within +/-% 4.10 0.75 0.80 0.40 0.80 0.30 0.60 0.30 0.50 0.20 0.40 0.18 0.40 0.18 0.40 0.18 0.30 0.12 Item No. ACH1708-03 ACH1708-05 ACH1708-07 ACH1708-09 ACH1708-11 ACH1708-13 ACH1708-15 ACH1708-19 ACH1708-21

Volume Adjustment

Adjustable Volume Pipettes


At 10% of Pipette Volume Increments Accuracy Precision l Color +/- % +/-% 0.02 Forest Green 4.50 1.50 0.2 Violet 1.80 0.70 At 100% of Pipette Volume Accuracy Precision +/-% +/-% Item No. 0.80 0.20 ACH1708-34 0.60 0.15 ACH1708-36

Volume 2.5 - 25 l 10 - 100 l

New Pipette Plunger Design

Cap. 10: 10

Konik-Tech

SAMPLE PREPARATION
Hamilton Pipette Accessories
AdvanTipTM Non-Filter Tips
AdvanTip precision pipette tips for routine high-throughput work where an extensive range of universal tips and multiple packaging options are needed to meet laboratory requirements. Tips include extended length, lter tips, and macrovolume tips. Hamilton pipette tips are universal-t and deliver outstanding accuracy and precision. AdvanTip products are certied to be free of RNase, DNase and pyrogens. Description 10 l, 96/rack, 10 racks/box 200 l, 96/rack, 10 racks/box Total Tips 960 960 Item No. ACH11006-01 ACH11006-03 Pipette Tips

AdvanTip Filtered Tips


Use lter tips for the ultimate protection against contamination when working in applications such as PCR, DNA amplication and sequencing, and other techniques involving the use of vaporous, radioactive, biohazardous or corrosive materials. Description 10 l, 96/rack, 10 racks/box 300 l, 96/rack, 10 racks/box Total Tips 960 960 Item No. ACH1007-02 ACH1007-07

SoftGrip Pipette Stand


Single or multi-channel pipette rack keeps pipettes in easy reach. Constructed of a heavy, nonskid, metallic casting. Description Six Position Pipette Stand Item No. ACH53578-01

ACH53578-01

www.konik-group.com