0% found this document useful (0 votes)
530 views5 pages

Dynamo 250

The document provides technical specifications and instructions for MH-635 power fuse lamps. It details dimensions, weights, voltages and amperages for various models. It also provides guidelines for fixture cleaning and controlling the unit via DMX controller, preprogrammed functions or easy controller. Safety warnings are provided to handle the unit properly.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
530 views5 pages

Dynamo 250

The document provides technical specifications and instructions for MH-635 power fuse lamps. It details dimensions, weights, voltages and amperages for various models. It also provides guidelines for fixture cleaning and controlling the unit via DMX controller, preprogrammed functions or easy controller. Safety warnings are provided to handle the unit properly.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Technical Specifications

MH-635 Power Fuse Lamps Dimension Weight AC 120V 50 / 60Hz AC 230 250V 50Hz T5A T3.15A EFP 12V 100W 385x170x122mm 3.8kg MH-635B AC 120V 60Hz AC 230 250V 50Hz T6.3A T5A ELC 24V 250W 405x170x122mm 4.5kg MH-635S AC 120V 60Hz AC 230 250V 50Hz T6.3A T5A ELC 24V 250W 385x170x122mm 4.5kg

Intelligent Scanner
Professional Lighting Technology

================================================================ For further requirements, contact the nearest authorized technical assistance office ================================================================

User Guide
Please read the instructions carefully before use

E.

FIXTURE CLEANING

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the units optics.

Clean with a soft cloth using normal glass cleaning products. Always dry the parts carefully. Clean the external optics at least once every 20 days. Clean the internal optics at least every 30/60 days.

INDEX

A. GENERAL INSTRUCTIONS B. MAIN FEATURES

EC Declaration of Conformity

C. LAMP
We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 89/336/EEC. 2D

EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996, EN61000-4-11: 1994. & Harmonized Standard

D. HOW TO CONTROL THE UNIT -----(1) By universal DMX controller -----(2) Preprogrammed function -----(3) By easy controller E. FIXTURE CLEANING

EN60598-1: 2000+ALL:2000+A12:2002 Safety of household and similar electrical appliances Part 1 : General requirements

( 2 ) Preprogram functions The unit can be linked together in daisy chain as many as you need in master/slave mode to perform the great built-in pre-programmed lighting shows triggered by music. In Master/Slave mode refer to the DMX settings below: Master unit: DMX start address MUST be set to 001. (first DIP switch = ON, all other are OFF) Slave units: DMX start address may have any value but NOT 001 (example: set the first 3 DIP switches to ON) 2-light show Dipswitch 10 off means the unit works normally and on means inversion. In order

to create a great light show, you can set dip switch 10 on on any unit that is linking to the master unit to get contrast movement to the master unit, even if you have two units only. 3D Dipswitch 10 on the first ( Master ) unit is no use for the 2-light show as it

is the master unit that operates the light show.

( 3 ) By easy controller The easy remote control is used only in master/slave mode. By connecting to the 1/4 microphone jack of the first unit (its DMX input plug is not used), you will find that the remote control on the first unit will control all the other units for Stand by, Function and Mode.

Built-in lighting shows triggered by Easy Controller:


Stand by Function Blackout the unit Strobe 1. sync. strobe 2. two-light strobe Strobe/ Sound (LED off) X/Y moving pattern selection (12 patterns) Pattern/ Sound (LED blinking) Color/Gobo selection

Mode

Sound (LED on)

A.

GENERAL INSTRUCTIONS
Please read the enclosed instructions carefully as they include important points about safety for the installation, usage and maintenance of the unit.

WARNING

Please keep this booklet with the unit for future consultation. If you sell the unit to another user, be sure that the new user also receives this instruction booklet thus giving them the necessary information about the use and general warnings regarding the unit. Before the initial start-up, please unpack and carefully check all components in case any damage may have occurred during shipping. Locate a suitable spot for your device where there is good ventilation. Also, make sure that no ventilating fans or slots are blocked. Protect our environment! Please dispose of the packing boxes properly. 4D Start the address How to address your DMX512 system: 1. Select the channels of DMX controller 2. Dipswitches Dip Value #1 1 #2 2 #3 4 #4 8 #5 16 #6 32 #7 64 #8 128 #9 256 The electrical work that is necessary for installation must done by qualified personnel. Always remember to unplug the unit from the main power before any service is done. Do not open the unit. There are no serviceable parts inside. It is very important to ground the yellow/green conductor to earth in order to meet regulations for safety. Check the surrounding area and make sure there are no flammable liquids, water or metal objects that could enter the fixture. If a foreign object enters the unit, immediately disconnect the main power. Also, place the fixture in a well-ventilated room at about 15 cm from the walls. Do not touch any wires during operation, as high voltage is hazardous. In the event of serious operating problems, stop using the unit immediately. Never try to repair the unit yourself. Repairs carried out by unqualified personnel can lead to damage or malfunction. Please contact the nearest authorized Technical Assistance Center. Always use genuine spare parts.

Examples: Channel 01dip / on : #1=1 Channel 05dip / on : #1, #31+4=5 Channel 09dip / on : #1,#41+8=9 Channel 13dip / on : #1,#3,#41+4+8=13

B.

MAIN FEATURES

D.

HOW TO CONTROL THE UNIT

The unit is a DMX512 scanner. It features full DMX512 control, 10 gobos/colors plus open and white, focus adjustable accurate optics system and stepper motor with blackout feature. Fan cooled. It can be operated by DMX512 control or can be used as an individual unit without controller. It can be linked together as many as required in master/slave mode, and perform the great built-in programmed lighting shows triggered by music. Please use a 3 pin XLR cable/plug when connecting them together. It features different pre-programmed chase patterns.

( 1 ) By universal DMX controller The DMX512 is widely used in intelligent lighting control, with a maximum of 512 channels.

C.

LAMP
A DMX512 system requires a controller, lighting equipment and cable. These are 5D connected together in a daisy chain with the terminator at the end. The cable cannot be branched or split to a Y cable. The terminator requires a 90-120 Ohm 1/4 Watt resistor soldered between two

Always switch off the mains supply and never handle the lamp or luminaire when it is hot. Do not touch the bulb with bare hands. If this does happen, clean the lamp with denatured alcohol and wipe with a lint free cloth before installing.

MH-635

signal cables. The DMX512 uses a very high-speed signal. Inadequate or damaged cables, bad solder joints or corroded connectors can easily distort the signal and shut down the system. A reliable DMX512 system starts with good quality cables. Each lighting unit needs to have an address set to receive the data sent by the

MH-635B

controller. The address number is between 0-511. The end of the DMX512 system should be terminated reducing signal errors. 3 pin XLR connectors are more popular than 5 pin XLR. 3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

MH-635S

5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)

You might also like