Matacryl RB
Installation Benefits
Cold applied and does not require heating or conditioning Available in both Hand and Spray applied grades (MATACRYL MANUAL membrane only) Available in both Horizontal and Vertical Grades VOC compliant and contains no solvent Reduced application times between Coats and layers Rapid installation and handover to Client / User Only requires 3mm dry film thickness ( d.f.t ) applied in one or two Coats Variety of Primers to suit each exposure Chemically inert and not requiring Hazmat precautions when disposing of Rain resistant within 30 minutes of application Setting and Curing times may be adjusted to suit ambient and site conditions No Protection Boards or additional Alternative Protective Layers ( APL ) required Limited manpower required Insignificant amount of equipment and plant required
1. 2. 3. 4.
Matacryl Primer + natural quartz Matacryl Membrane Layer Matacryl Membrane Layer, second coat Matacryl STC (optional) broadcasted with quartz sand
Note: Matacryl STC (optional) is only used if the membrane layer stays exposed for several weeks to UV.
MATACRYL Membrane
Physical Properties
Dynamic puncture resistance under railway ballast
Engineering Properties
Value
Meets specification of no rupture of the membrane after 2 million loading cycles Passes 3,4 MPa - rupture in concrete At 23C: 2.4 mm thickness - 8 mm At 0C: 2.1 mm thickness - 6.5 mm At -20C: 2.7 mm thickness - 8.8 mm At 0.5 mm I3 At 1.5 mm I4 At 0.5 mm L3 At 1.5 mm L4 23.3 % 60 IRHD (1 hour after application) 85 IRHD (3 hours after application) 55.7 mg after 500 turns 63.9 mg after 1000 turns 24 MPa / 107% elongation 0 blisters at 2.5 BAR
Test Method
SNCF Method
Test Institute
SNCF (French Railways) Laboratoire, Vitry-sur-Seine
Crack-bridging capacity
BPG fr Beschichtungen
ETAG 005 Part 1 No. 5, 3, 3, 2, 2 TR 000 ETAG 005 Part 1 No. 5, 3, 3, 2, 2 TR 007 DIN 53512 N FP 98 285
Taber abrasion, load 1000 gr. Roll CS 10 Tensile strength at -20C Negative side hydrostatic pressure test Crack bridging capability Shear strength Chloride ion ingress
ISO 7784-2
VTT 2632
VTT, Finland
Average of 5.58 at -30C > 0.65 N/mm2 Maximum increase in chloride ion concentration not more than 0.04% No cracks in the membrane
BBA Method
BBA Method
BBA
This brochure is not intended to establish product recommendations for any installation. To the best of our knowledge the information contained herein is true and accurate at the time of issue, but is subject to change without prior notice. No part of this brochure may be copied without written authorisation of RPM/Belgium N.V. - RPM/Belgium N.V.
Authorised applicator:
RPM/Belgium N V - 10/2009 - Doc 283/GB
Warranty RPM/Belgium N.V. and Alteco Technik GmbH warrant all goods to be free from defects and will replace materials proven to be defective. The given information corresponds to our present standard of knowledge. However, it is the buyers responsibility to determine the suitability of the products in individual cases by conducting own tests.
RPM/Belgium N.V. and Alteco Technik GmbH are subsidiaries of RPM Inc., USA, a public owned American company and are leading manufacturers of industrial flooring systems, coatings, sealants and membranes. RPM/Belgium N.V. and Alteco Technik GmbH are certified by Lloyds to the ISO 9001 quality standard.
RPM/Belgium N.V.
Industriepark Noord H. Dunantstraat 11B B-8700 Tielt Tel.: + 32 (0) 51 / 40 38 01 Fax: + 32 (0) 51 / 40 55 90 E-mail: [email protected] http://www.rpm-belgium.be