The THYROTRONIC Rectifier line from Benning is designed to address critical DC load powering and battery charging requirements in a wide range of stationary battery plant applications. Our THYROTRONIC Rectifiers combine microprocessor control with well established power conversion technology, to provide you with the highest quality rectifiers on the market today. These units can be equipped to meet all of your battery charging requirements. They are compatible with Valve Regulated Lead Acid (VRLA), Free Vented Lead Acid (FVLA) and Nickel-cadmium type battery plants. They can be configured for nominal charging voltages from 24 VDC to 120 VDC. These units comply with the stringent requirements of power utilities, communications providers, railroads, power substations, microwave relay sites and switchgear applications.
Key Features
Microprocessor Controls And Digital Display Panel Including An RS-232 Port For Ease Of Set Up, Operation and Maintenance Programmable Float/Equalize Operation Including Pre-programmed Automatic Equalization Functions Pre-programmed Battery Commissioning Functions Commercial AC Input Monitoring And Automatic Re-start Sequencing For Large Sites with Multiple Rectifiers Automatic Rectifier Output MonitoringInsures Rectifier Is Capable Of Delivering Full Output Current When Required Battery Circuit/Battery Availability FunctionAutomatically Tests Battery For Presence and Can Periodically Test The Battery Plant To Insure Expected Battery Reserve Time Is Available High/Low Output Voltage MonitoringInsures The Rectifier Is Providing Proper Output Voltage To Maintain The Standby Battery Plant Earth Fault MonitoringTests The Resistance Of The Battery Leads To Detect Leakage Resistance To Ground Redundant Hardware ControlsProvides Analog Hardware Settings Which Take Over Control In Case of A Microprocessor Control Failure Voltage Drop CompensationCan Automatically Correct For Long Battery Cable Runs Which Can Lead To Excessive Voltage Drop
Thyrotronic(R1_10) Benning Power Electronics 2010 Specifications are subject to change without notice
Output
Voltage: 24, 48, 60, 120 VDC Current: 10, 25, 50 , 100 ,150 ,200 ,400A Voltage Regulation: 0.5% Ripple Voltage: <2% with 3 X I battery
Standards
NEMA Complaint NFPA 70 ANSI C37.90.1 DIN 41773 OSHA 29CFR1910 UL, cUL Pending
10
Wall
24,48,120VDC
25
Wall
165 (75)
47.2 x 23.6 x 23.6 (1200x600x600) 47.2 x 23.6 x 23.6 (1200x600x600) 59.1 x 23.6 x 23.6 (1500x600x600) 59.1 x 35.4 x 23.6 (1500x900x600) 78.7 x 31.5 x 31.5 (2000x800x800)
882 (401) 992 (451) 1102 (501) 1213 (551) 2095 (952)
10 and 25 A Rectifiers are normally arranged for 1, 208, or 240 VAC input (Multi-tap) 50 and 100 A Rectifiers are normally arranged for 1, 240, or 3,480 VAC input 100 A and larger units would normally be arranged for 3, 480 VAC input Note: 3, 208, and 480 VAC inputs are available for all units as special order. Other Input voltages are available on request Benning Power Electronics, Inc. 11120 Grader St . Dallas . TX 75238 E-Mail: [email protected] WEB: www.benning.us
Thyrotronic(R1_10) Benning Power Electronics 2010 Specifications are subject to change without notice