Overall Measurement Accuracy
Overall Measurement Accuracy
Box 801304 Houston, TX 77280-1304 Abstract This paper presents methods for determining the uncertainty of both differential and linear metering stations. It takes into account the type of meter, number of meters in parallel, type of secondary instruments, and the determination of physical properties. The paper then relates this information to potential influence on system balance. Introduction Gas measurement uncertainty is a function of the following items: Selection of the appropriate metering device. Correct Installation of the metering device. Proper operation and processing of the metering information. Proper maintenance of the metering device. Understanding how measurement uncertainty applies to metering requires a basic knowledge of the terminology and assumptions used in the calculation of measurement uncertainty. Measurement uncertainties can be categorized as the following: Pseudo Pseudo uncertainties are potential human errors or those associated with the malfunction of an instrument. Once identified, these errors can usually be corrected and are not included in the calculation of measurement uncertainty. Random uncertainties are potential measurement errors that have an equal chance of being higher or lower than the true value of the measured variable. If a large number of measurements are made, the random error in the individual measurements cancel and the mean of the measurements will be approximate to the correct value. Systematic uncertainties are measurement errors that are directional or contain a bias. Because these errors are directional, they do not cancel as additional measurements are made. The elements of the random and systematic uncertainties are classified as either independent or dependent and must be determined before the total measurement uncertainty can be obtained. The determination of gas measurement uncertainty has been and is addressed in numerous industry articles and standards publications. Three such articles and publications that were referenced in the preparation of this paper are: (1) Norman and Jepson, (2) Tiemstra, Rans, and Backus, (3) AGA Report No.3 Part 1 1990. However, for the purposes of evaluation, this paper will not concern itself with the influence of the interdependence of variables. But will utilize the calculation procedure given in A.G.A. Report No. 3 (API MPMS 14.3, ANSI 2530, GPA 8185-90) Part I 1990 to determine the orifice meter measurement uncertainty and will apply the same metrology to the linear meter (turbine, rotary, or diaphragm meter) measurement uncertainty. The uncertainty for a single meter run is evaluated from the random and systematic uncertainty of the primary element (orifice, turbine, rotary, or diaphragm meter) and its instrumentation. The uncertainty of the primary element includes the uncertainty associated with the flow coefficient, expansion factor, diameter of the meter run, diameter of the orifice plate bore, and calibration of the linear meters. For an Individual meter run: Random uncertainty reduces as the number of measurements increases. However, additional measurements will not reduce the systematic uncertainty. Because the random and systematic uncertainties are characteristically different, the calculation of each must be performed independently. The combination of the two independently performed calculations then forms the total measurement uncertainty.
Random
U TM = U RM + U SM
Where UTM - Total meter run uncertainty URM - Meter run random uncertainty
Systematic
U RM =
(U Ri )
U SM =
(U Si )
U Si = (X i A i )
The percent random uncertainty contributed by each variable, URi , is defined as follows:
U Ri = (X i A i )
The sensitivity coefficient of each variable at the point of evaluation, Xi, can be determined by calculating the results for the conditions of evaluation, R, and the change in the result, R, produced independently by the accuracy variation of each variable at the conditions of evaluation and substituting into the following equation:
The accuracy of the calibration standards (Ai) are expressed as a percent of reading so they can be substituted directly into the USi equation along with the sensitivity coefficients (Xi ) calculated for the appropriate element to determine the systematic uncertainty contribution by each variable. The total systematic uncertainty is determined using the USM equation.
U SM =
(U Si )
R Xi = R
The percent accuracy of each variable at the point of evaluation, e.g. average differential pressure, is determined as follows: For variables whose accuracy is stated as function of its full-scale value, the percent accuracy is the value of the accuracy at full scale, AF, divided by the value of the variable at the conditions of evaluation, VCE.
However, since the criteria applied for the determination of the sensitivity coefficient, can vary and is specific to an application, the sensitivity coefficients used for the orifice meter uncertainty were chosen from A.G.A. Report No.3 (API MPMS 14.3, ANSI 2530, GPA 8185-90), Part 1 1990 and similar sensitivity coefficient were developed for the linear meters. The use of these particular sensitivity coefficients can result in a small understatement of the uncertainty estimates resulting from not accounting for the interdependence of some of the elements.
A Ai = F V CE
100
Differential Meter Uncertainty The variable elements of a gas orifice meter measurement uncertainty calculation are as follows: Differential Pressure, dp Static Pressure, Pf Flowing Temperature, Tf Gas Relative Density, Gr Gas Compressibility Factor, Zf & Zb (Fpv) Orifice Meter Coefficient of Discharge, Cd Orifice Bore Diameter, d Meter Tube inside Diameter, D Expansion Factor, Y Differential Pressure Calibrator, dpc Static Pressure Calibrator, Pfc Flowing Temperature Calibrator, Tfc Gas Relative Density Calibrator, Grc To calculate the measurement uncertainty for a multiple meter run station, the variables that are independent on a per run basis are differential pressure, static pressure, temperature, and meter run tolerances. The variables common to all runs in the station are the relative density (specific gravity), gas composition, and calibration standards. The total percent measurement uncertainty for a meter station is as follows:
As an example, assume that one of the variables is a differential pressure value whose accuracy is stated as 0.1% of full scale, its full scale is 100 and the point of evaluation is 50. The percent accuracy of the variable at the point of evaluation, Ai, would be:
U TS = U RS + U SS
Where UTS - Total orifice meter station uncertainty URS - Total orifice meter station random uncertainty USS - Total orifice meter systematic uncertainty The total orifice meter station random uncertainty is given as:
U RS =
U Ri n
2 per Run
(U Ri ) 2
per Station
Where n is the number of meter runs. And the total linear meter station systematic uncertainty, USS, as:
U RS =
U Ri n
2 per Run
(U Ri )
2 per Station
U SS =
(U SM ) 2
per Run
Where n is the number of meter runs. And the total orifice meter station systematic uncertainty, USS, as:
U SS =
(U SM ) 2
per Run
Since there are numerous combinations of equipment, operating conditions, and calculation methods existing for linear metering, it is impossible to establish a single uncertainty relationship. The most practical approach is to provide uncertainty ranges for the most typical linear metering combinations.
Since there are numerous combinations of equipment, operating conditions, and calculation methods existing for orifice metering, it is impossible to establish a single base line uncertainty relationship. The most practical approach is to provide uncertainty ranges for the most typical orifice metering combinations. LINEAR Meter Uncertainty (Ultrasonic, Turbine, Rotary, and Diaphragm) The variable elements of a gas linear meter measurement uncertainty calculation are as follows: Static Pressure, Pf Flowing Temperature, Tf Gas Relative Density, Gr Gas Compressibility Factor, Zf & Zb Linear Meter Linearity, K factor, PML Linear Meter Calibrator, PMpc Static Pressure Calibrator, Pfc Flowing Temperature Calibrator, Tfc Gas Relative Density Calibrator, Grc To calculate the measurement uncertainty for a multiple meter run station, the variables that are independent on a per run basis are linear meter calibration or proof, static pressure, and temperature. The variables common to all runs in the station are the relative density (specific gravity), gas composition, and calibration standards. The total percent measurement uncertainty for a meter station is as follows:
Energy Determination Uncertainty The measurement of total energy received or delivered is customarily the product of the measured volume and the heating value (Hv) per unit volume. The heating value per unit volume is typically an inferred measurement resulting from a chromatographic analysis of a representative sample of the gas being received or delivered. In addition to heating value per unit volume, relative density (specific gravity) used in the determination of volume is also obtained from the chromatographic analysis. Industry standards, which address the performance of chromatographic analysis, the calculation of heating value per unit volume, and relative density of a gas sample, are: (4)ASTM D 1945-96 (GPA 2261-95) - Standard Test Method Analysis of Natural Gas by Gas Chromatography (5)ASTM D 3588-98 (GPA 2172-96) - Standard Practice for Calculating Heat Value, Compressibility Factor, and Relative Density(Specific Gravity) of Gaseous Fuels The industry standards, ASTM D 1945-96 (GPA 226195) and ASTM D 3588-98 (GPA 2172-96) provide a precision statement for repeatability and reproducibility as a function of the mole fraction of each component in the gas mixture. The repeatability is the expected precision within a laboratory using the same equipment and the same analyst. The reproducibility is the expected precision when different laboratories using different equipment and different analysts use the same method. Tables 1 and 2 provide the given repeatability and reproducibility tolerances.
U TS = U RS + U SS
Where UTS - Total orifice meter station uncertainty URS - Total orifice meter station random uncertainty USS - Total orifice meter systematic uncertainty The total linear meter station random uncertainty is given as:
Component Mole %
Repeatability %
0 to 0.1 0.01 0.1 to 1.0 0.04 1.0 to 5.0 0.07 5.0 to 10 0.08 Over 10 0.10 Table 1 - ASTM D 1945-96 Precision Repeatability Criteria Component Mole % Reproducibility %
Since the ASTM D 1945-96 repeatability and reproducibility criteria originated from a statistical examination of interlaboratory test results, it includes the influences of properly prepared calibration gas standards. The Hv and relative density precision values assume that the sampling methods and sampling systems utilized provide a representative sample of the flowing gas stream for analysis. System Balance Influence Engineering departments can use metering station uncertainty information in selecting the type of equipment to be use in a meter station. Equipment can be selected to meet a system balance expectation or uncertainty. It can be used by gas control departments to estimate when the uncertainty of a meter stations measurement is increasing. It can be used to help manage lost and unaccounted-for numbers. If all one type of equipment is installed on the inlet and all of another type on the outlet, the metering system may not produce the desired system balance results. It can be used by maintenance to understand on which pieces of equipment to concentrate their efforts.
0 to 0.1 0.02 0.1 to 1.0 0.07 1.0 to 5.0 0.10 5.0 to 10 0.12 Over 10 0.15 Table 2 - ASTM D 1945-96 Precision Reproducibility Criteria The individual component reproducibility tolerances were combined using the square root of the sum of the squares method as shown in ASTM D 3588-98 (GPA 2172-96) to obtain a precision statement. This is a common methodology employed when determining the tolerance of calculated values containing random individual elemental tolerances. Chromatographic analysis and the calculations of Hv and relative density performed using industry standards, ASTM D 1945-96 (GPA 2261-95) and ASTM D 3588-98 (GPA 2172-96), will produce heating value results to within 0.25% and relative density results to within 0.003 relative density units for a typical pipeline natural gas having the following composition: Mixture Component
References (1) Calculation defines uncertainty of unaccounted-for gas, Norman, R and Jepson, P., Oil & Gas Journal Report April 6, 1987 (2) Comparison of Orifice and Turbine meter Accuracy, Tiemsyra, P., Rans, R., and Bacus, H., American Gas Association Distribution/Transmission Conference April, 1991, Nashville, Tennessee (3) Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids, Part 1 - 1990, General equations and uncertainty guidelines. American Gas Association Report No. 3, Third Edition, Arlington, VA, October 1990. (4) Standard Test Method Analysis of Natural Gas by Gas Chromatography - ASTM D 1945-96 (GPA 2261-95) (5) Standard Practice for Calculating Heat Value, Compressibility Factor, and Relative Density (Specific Gravity) of Gaseous Fuels - ASTM D 3588-98 (GPA 2172-96)
Mole %
Methane 96.5222 Ethane 1.8186 Propane 0.4596 Isobutane 0.0977 n-Butane 0.1007 Isopentane 0.0473 n-Pentane 0.0324 n-Hexane 0.0664 Nitrogen 0.2595 Carbon Dioxide 0.5956 BTU/Ft3 1036.06 Ideal Gross Hv per Real Ft3 @14.73 & 60F 0.582 Real Relative Density @14.73 & 60F