0% found this document useful (0 votes)
53 views4 pages

International Limited: Defect / Non Compliance Report

Frederick Mina conducted inspections of various lifting equipment on board Transocean Support Services vessels on December 1st and 7th, 2012. He issued non-compliance reports documenting defects found in an eye and jaw swivel, hook, and two shackles that rendered them unfit for use, including cracks, corrosion, and deformation. The equipment was to be removed from service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views4 pages

International Limited: Defect / Non Compliance Report

Frederick Mina conducted inspections of various lifting equipment on board Transocean Support Services vessels on December 1st and 7th, 2012. He issued non-compliance reports documenting defects found in an eye and jaw swivel, hook, and two shackles that rendered them unfit for use, including cracks, corrosion, and deformation. The equipment was to be removed from service.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7887597 Identification Number

07/12/2012

FREDERICK MINA

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment EYE & JAW SWIVEL

SWL

SW 03

Eye and Jaw Swivel 1pc

15 tonnes

LOCATION: POOP DECK


Particulars of defects found which are, or could, become a danger to persons or none Crack found (Not fit for Use) Name and address of equipment owner: Particulars of any repair, alteration to remedy defect or none Remove from service Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 07/12/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: FREDERICK MINA Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

87598
Identification Number

07/12/2012

FREDERICK MINA

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment HOOK Hook

SWL

933287-0-1-4

1pc

50 tonnes

LOCATION: POOP DECK


Particulars of defects found which are, or could, become a danger to persons or none Crack found (Not fit for Use) Name and address of equipment owner: Particulars of any repair, alteration to remedy defect or none Remove from service Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 07/12/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: FREDERICK MINA Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7887587 Identification Number

01/12/2012

FREDERICK MINA

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID:

AX 73

1pc

Bow Safety Pin Shackle

13.5 tonnes

LOCATION: MAIN DECK


Particulars of defects found which are, or could, become a danger to persons or none Excessively corroded shackle pin (Not fit for Use) Name and address of equipment owner: Particulars of any repair, alteration to remedy defect or none Remove from service Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 01/12/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: FREDERICK MINA Conducting: Examination only

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

DEFECT / NON COMPLIANCE REPORT


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

7887586 Identification Number

01/12/2012

FREDERICK MINA

LEEA, SNT LEVEL II MT, PT & UT

Qty

Description of Equipment SHACKLE

SWL

Shackle ID:

AX 72

1pc

Bow Safety Pin Shackle

13.5 tonnes

LOCATION: MAIN DECK


Particulars of defects found which are, or could, become a danger to persons or none Deformed Bow (Not fit for Use) Name and address of equipment owner: Particulars of any repair, alteration to remedy defect or none Remove from service Address of premises where Test / Examination was held:

Transocean Support Services

AD 10

We hereby certify that on 01/12/2012 (date) defect was found on the item/s described on this Certificate as at the time of inspection. Signature of Inspector: Conducting Examination Name of Inspector: FREDERICK MINA Conducting: Examination only