Air Cooled Chiller Air To Water Heat Pump: Features Options / Accessories

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

WATER SYSTEMS

Features

Options / Accessories

Very compact units


New Design
Leaving and Return Water Temperature control
Hydro Pack Standard
Buffer Tank supresion function
Dynamic Set Point Function
Fan Speed Control as standard
Condenser protection grill as standard
Very safety units: including filter and sight glass
Anti-corrosion coated condenser fins as standard

Unit available without Hydro Pack


Anticorrosion condenser fins
BMS Communication
Remote control
Remote Terminal (new)
High Pressure Fans (new)
Auxiliar Electric heater (new)
External Buffer tank (new)
Water filter (for units without Hydro Pack)
Flow switch (for units without Hydro Pack)
Copper condenser fins

Air cooled chiller


Air to water heat pump

E-COM-C0701

YLCA-YLHA 5 to 40
A complete range from 5 kW up to 156 kW

R410A

YLCA-YLHA 5 to 40
5 to 41 kW
Preliminary

Technical features

data
M Single phase T Three phases supply C Hydro Pack
YLCA / YLHA G1

Performance

Compressor

5 M-MC

7 M-MC

7 T-TC

9 M-MC

9 T-TC

12 T-TC

15 T-TC

20 T-TC

27 T-TC

40 T-TC

Cooling capacity cooling only units (1)

kW

5.4

7.1

7.1

8.6

8.6

12.0

14.5

19.5

25.6

38.5

Total Input Power (1)

kW

1.8

2.4

2.4

3.2

3.2

3.9

5.4

6.6

8.7

12.8

Cooling capacity heat pump units (1)

kW

5.2

6.9

6.9

8.6

8.6

11.6

14.2

19.2

25.6

38.0

Heating capacity heat pump units (1)

kW

5.8

7.9

7.9

9.8

9.8

12.6

15.3

20.4

26.3

40.5

Total Input Power cooling/heating mode (1)

kW

1.9 / 2.0

2.6 / 2.8

2.6 / 2.8

3.3 / 3.1

3.3 / 3.1

3.8 / 3.7

5.2 / 4.7

6.6 / 6.2

8.7 / 8.2

12.6 / 12.0

Capacity steps

Sound power level

dB(A)

70

70

70

71

71

73

73

74

78

81

Sound pressure level at 10 m

dB(A)

40

40

40

41

41

43

43

44

48

51

0 / 100

Type

Scroll

Quantity
Air side heat
exchanger

Fans quantity

Water side
heat
exchanger

Type

1
1

Working Ambient temp. cooling / heating mode

(4) (-18C) -10C ~ 46C / -10C ~ 20C


Heat Plate Exchanger

Unit water volume (2)

Litres

1.1

Pump Type

1.1

1.2

Electrical
features

1.2

1.5

2.8

Circulator (3 speeds)

3.2

Multi stage

Available pressure (1) (2)

kPa

51

80

80

75

75

115

152

134

191

190

Pressure drop (1) (3)

kPa

52

33

33

31.5

31.5

22.5

23

46

40

53

Working range water leaving temp. cooling/heating (5)


Dimensions
& Weight

-18C ~ 46C / -10C ~ 20C

-5C to 15C / 30C to 50C

Water connections

inch

Height / Width / Depth

mm

762/905/460

Weight without pack / pack cooling only

kg

77 / 83

98 / 105

103 / 110

136 / 150 145 / 160 205 / 220 275 / 290 340 / 400

Weight without pack / pack heat pumps

kg

79 / 85

100 / 107

105 / 112

140 / 154 149 / 164 220 / 235 315 / 330 380 / 440

Voltage / Phases / Frequency

V/ph/hz

Running current (max) (2)

1 1/4

965 / 905 / 460

1 270 / 905 / 460

230-1-50 230-1-50 400-3-50 230-1-50


12.6

17.1

7.6

1 1/2

1270/1430/502 1270/1876/502 1573/1500/822

400-3-50

23

8.3

12.7

15.8

18.1

23

34

YLCA: Cooling only units models. YLHA: Air to water heat pump models.
(1) net values at Eurovent nominal conditions (2) version C with hydro kit (3) version without hydro kit (4) -18C with LAK option (5) below 6C with glycol
Nominal conditions: Cooling capacities in kW given for 7C water leaving temperature t 5C and 35C ambient temperature

Heating capacities in kW given for 45C water leaving temperature and 7C ambient temperature

Compatibility table / Codes


Model

5 MC

7 MC

7 TC

9 MC

9 TC

12 TC

15 TC

20 TC

27 TC

40 TC

YLCA Cooling only units (Pack included)

668550582

668550782

668550784

668550982

668550984

668551282

668551582

668552082

668552782

668554082

YLHA Heat pump units (Pack included)

668650582

668650782

668650784

668650982

668650984

668651282

668651584

668652082

668652782

668654082

Options (Factory fitted)


Model

5M

7M

7T

9M

9T

12 T

15 T

20 T

27 T

40 T

YLCA Cooling only units (without Pack)

668550580

668550780

668550783

668550980

668550983

668551280

668551580

668552080

668552780

668554080

YLHA Heat pump units (without Pack)

668650580

668650780

668650783

668650980

668650983

668651280

668651583

668652080

668652780

668654080

611991084

611991085

611991086

611080786

611080787

High pressure fans

611991082

Copper/copper condenser c/o


Copper/copper condenser h/p

611080780

611991083

611080781

LAK -18C

611080782

611080783

611080784
611080785

613112083

STANDARD

Accessories (Supplied loose)


Water tank

613990200 (20 litres)


20 L + 2 kW (1~)
20 L + 3 kW (1~)

Water tank + heater

20 L + 2 kW (3~)

613990200 or 613990300

613990300 (30 litres)

613990205

613991411 (140 litres)

613990206
-

30 L + 4.5 kW (1~)
30 L + 6 kW (3~)

613990207

613990305
-

140 L + 4.5 kW (3~)


Water filter *

613990306 (TBC)

611300100

611300120
611992021
613802011

Remote terminal

*included with unit version C only for unit without pack.

Remote control

BMS Communication

613990306

Water flow switch *

Anti vibration mounting

(1)

613802231
613029001

613029002
613802041

(1) 668554084 for YLCA 40 G1 TP / 668654084 for YLHA 40 G1 TP

611300150

WATER
INTAKE 1G
WATER
OUTLET 1G

Dimensions, hydraulic connections


and space requirements

WATER
INTAKE 1G

WATER
INTAKE 1G

WATER
OUTLET 1G

WATER
OUTLET 1G

DRAIN
CONNECTION
EXT. 15

DRAIN
CONNECTION
EXT. 15

9 05

405

905

YLCA-YLHA 12/15 T-TC

Model YLCA-YLHA 5/7/9/12/15


965

All dimensions in mm. Drawings not a scale.

933

All dimensions in mm. Drawings not a scale.

WATER
INTAKE 1G
WATER
OUTLET 1G

905

405

1238

DRAIN
CONNECTION
EXT. 15

WATER
INTAKE 1G
WATER
OUTLET 1G

DRAIN
CONNECTION
EXT. 15

405

All dimensions in mm. Drawings not a scale.

905

All dimensions in mm. Drawings not a scale.

965

933

730

YLCA-YLHA 7/9 M-MC/T-TC

762

YLCA-YLHA 5 M-MC

9 05

1270

WATER SYSTEMS

DRAIN
CONNECTION
EXT. 15

YLCA-YLHA 20/27 T-TC

YLCA-YLHA 40 T-TC-TP

1573

300

600

300

800

1272

WATER INTAKE
AND OUTLET

)
20
ze 7)
(si ze 2
0
i
3
14 76 (s
18

00
800

15

50

82

WATER
INTAKE
AND OUTLET

All dimensions in mm. Drawings not a scale.

All dimensions in mm. Drawings not a scale.


800

3000

WATER INTAKE
AND OUTLET

300

800

1000

Model YLCA-YLHA 40

1000

300

Model YLCA-YLHA 20/27

600

800

300

800

1000

WATER INTAKE
AND OUTLET

300

800

600

600

800

1000

800

300

800

800

WATER
INTAKE
AND OUTLET

1000

All dimensions in mm. Drawings not a scale.

All dimensions in mm. Drawings not a scale.


3000

800

KE
ET

YLCA-YLHA 5 to 40