Mitsubishi: Notification of The MELSEC-Q Series PLC CPU Upgrade (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU)
Mitsubishi: Notification of The MELSEC-Q Series PLC CPU Upgrade (Q02CPU, Q02HCPU, Q06HCPU, Q12HCPU, Q25HCPU)
MITSUBISHI ELECTRIC
2000 No.135E
MITSUBISHI
GENERAL-PURPOSE PROGRAMMABLE LOGIC CONTROLLERS
New!
The following functions have been added to the QCPU to make it even easier to use. The additional functions are shown as follows. !Multiple PLC system compatibility
" Sequence control and motion control are incorporated in one PLC system. " High-speed control by distributing load over multiple CPUs. " Total volume of program memory and devices expanded by the addition of CPU modules. " Operations of other CPU modules continue while one of the CPU modules goes down.
!Overwriting on the standard ROM made possible with the memory card (Automatic write to standard ROM)
When ROM operations are being performed with the standard ROM, it is possible to write over the parameters and programs in the standard ROM directly from a memory card at the field without PC (GX Developer).
QCPU2
Q25HCPU QX10 QX10 QX41 QX41 QX10 QX10 QX41
*2 CPU slot:PLC No.1 Slot 0:PLC No.2 Slot 1:PLC No.3 Slot 2:PLC No.4
Q25HCPU
Q61P-A1 POWER MODE RUN ERR USER BAT BOOT
USB
USB
RS-232
RS-232
Q25HCPU
MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
QX10
QX10
1 1
1 1
2 2
USB
USB
USB
USB
RS-232
RS-232
RS-232
RS-232
*1: Motion CPUs are CPU modules that are connected to Mitsubishi servo amplifiers with SSCNET (which reduces wiring and afford highly reliable connections) in order to perform motion control. This enables synchronous operations with the servo motors and the simple structuring of absolute position systems. The motion CPUs will be released soon. *2: The CPU slot (slot on the right of the power supply module) accepts only the QCPU. (2) Features (a) Possible to incorporate sequence control and motion control in one PLC system It is possible to select the most suitable CPU module from the PLC CPUs (five types) and motion CPUs (two types) in accordance with the size and use of the system when structuring systems.
PLC CPU Q motion CPU
Sequence control
Q25HCPU
Q61P-A1 POWER MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
QX10
QX10
USB
USB
USB
USB
RS-232
RS-232
RS-232
RS-232
Motion control
Enables sequence control and motion control in one system
(b) High-speed control by dispersing the load brought about by control tact By separating and isolating CPU modules for each control item, such as machine control and data processing, it is possible to enable high-speed control without affecting data processing or other processes.
Data processing (slow) Machine control (fast)
Q61P-A1 POWER
Q25HCPU
MODE RUN ERR USER BAT BOOT
QJ71BR11
QX10
QX10
QX41
Q61P-A1
POWER
Q25HCPU
MODE RUN ERR USER BAT BOOT
Q25HCPU
MODE RUN ERR USER BAT BOOT
QX10
QX10
QX41
QJ71BR11
PULL PULL
USB
USB
USB
RS-232
RS-232
RS-232
Machine control is executed further faster by load distribution according to control tact
(c) CPU modules additions make it possible to expand the program memory and the number of devices As it is not necessary to change I/O numbers when adding CPU modules, it is possible to expand program memory and the number of devices without having to amend existing programs.
10% of the memory available
Q61P-A1 POW ER
QJ71BR11
MNG D.LIN K RD ER R
QX10
QX10
QX41
Q61P-A1
POW ER
Q25HCPU
MODE RUN ER R USER BA T BOOT
Q25HCPU
MODE RUN ER R USER BA T BOOT
RUN T.PASS SD ER R
QJ71BR11
MNG D.LIN K RD ER R
QX10
QX10
QX41
PU LL PU LL
PU LL PU LL PU LL
USB
USB
USB
RS-23 2
RS-23 2
RS-23 2
Addition of one CPU modules: Expansion of program memory. Expansion of device memory.
(d) Possible to continue operations with other CPU modules even when one CPU module goes down As the operations (continue/stop) for other CPU modules can be set with parameters when one CPU module goes down, it is possible to keep the damage to the entire system at a minimum when an error occurs with one CPU module. However, operations for PLC No.2 to 4 will be suspended if PLC No.1, which controls the multiple PLC system, goes down.
Q25HCPU
MOD E R UN ER R U SER BA T BOOT
Q6 1P-A1
POWER
QX10
QX10
QX10
QX10
QX10
QX10
QX10
QX10
QX10
Q6 1P-A1
POWER
Q25HCPU
MOD E R UN ER R U SER BA T BOOT
Q25HCPU
MOD E R UN ER R U SER BA T BOOT
Q25HCPU
MOD E R UN ER R U SER BA T BOOT
QX10
QX10
QX10
QX10
QX10
QX10
QX10
QX10
QX10
PU LL PU LL
PU LL PU LL PU LL PU LL
U SB
U SB
U SB
U SB
R S-232
R S-232
R S-232
R S-232
If one CPU module goes down, the entire system goes down
Possible to continue operations with other CPU modules even when one CPU module goes down
Standard RAM
R0
t C W @ X ^
i 32k j _
ZR131071
*: The remove/restore time for 4k point local devices with eight files has been reduced from 31.5ms to 6ms.
3. Overwriting on the standard ROM made possible with the memory card (Automatic write to standard ROM)
The automatic write to standard ROM function automatically writes the parameters and sequence programs already stored in the memory card across to the QCPU's standard ROM. The simple amendment of programs away from the local site. " Personal computers (GX Developer) are not required for installing programs. It is no longer necessary to take a personal computer when installing programs amended by the design office into the QCPU at a local sites. " Only necessary to send a memory card to distant sites. The local operator only needs to insert the memory card into the QCPU. (Dipswitch setting are necessary.) ATA cards are useful for memory cards. " Saving from the program lost by battery out. " Easy to load the data from a personal computer.
Program file Parameter file CPU
Program memory
Memory card
Standard ROM
Local site
4. Possible to debug the QCPU during operations (Forced ON/OFF of external inputs/outputs)
The forced ON/OFF of external inputs/outputs is a function that enables the GX Developer to forcibly switch the input (X) and output (Y) ON and OFF while the QCPU is operating.
<In the case of PLC test functions> Not possible to switch off with PLC tests X0 Sensor input M0 Facility abnormality detection ON Y10 Warning alarm output M100 ON
Y10 X0
Not possible to switch ON and OFF with the PLC test while the QCPU is operating <In the case of forced ON/OFF of external input> OFF possible with enforced input X0 Sensor input M0 Facility abnormality detection ON Y10 Warning alarm output M100 OFF Personal computer (GX Developer) ON and OFFof external output possible with enforced output Note: Y10 is set at OFF in the output module, but remains ON with the circuit.
[Forced ON/OFF of external input] The enforced OFF function can set the system at OFF without disconnecting the external lines when the sensor remains ON. [Forced ON/OFF of external output] By forcibly setting the warning alarm output signal for other facilities to OFF when it remains on during facility start-up, it is possible to resolve the system error and continue with test operations.
Modem
Accessing machine
Ethernet
(2) Remote passwords are made possible through combinations of the following modules. " Serial communication modules of function version B (QJ71C24 (-R2)) " Ethernet modules of function version B (QJ71E71 (-B2))
(2) The MELSECNET/H module (QJ71LP21-25, QJ71BR11) of function version B is necessary to structure a MELSECNET/H remote I/O network.
[Compatible CPU]
Function Multiple PLC system compatibility Relevant QCPU Relevant GX Developer " QCPUs with function version B or higher Version 6 (products shipped during and after (SW6D5C-GPPW) or higher November 2000) " QCPUs with function version B or higher. " QCPUs with serial numbers of 02092 or higher (products shipped during and after September 2000)
Increased standard RAM capacity (Q12HCPU and Q25HCPU only) Automatic writing in the standard ROM Forced ON/OFF of external inputs/outputs Remote password setting MELSECNET/H remote I/O network compatible
SERIAL 02092
-B
Function version
Refer to the data book for details on the possibility of using AnS series I/O modules and special function modules.
[Manuals]
Manual name QCPU(Q mode) Users Manual (Functions Explanation/Proguram Fundamentals) QCPU(QMode)/QnACPU Programming Manual (Common Instructions) Manual shipment type Sold separately Sold separately IB/SH No. SH-0080038-B SH-0080039-C Type code 13JL98 13JF58
Spain
Taiwan Korea
Singapore
Thailand
Indonesia
India Australia
Sales office Mitsubishi Electric Automation Inc. 500 Corporate Woods Parkway Vernon Hills, IL 60061 MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda. Av. Rio Branco, 123-15 ,and S/1507, Rio de Janeiro, RJ CEP 20040-005, Brazil Mitsubishi Electric Europe B.V. German Branch Gothaer Strasse 8 D-40880 Ratingen, GERMANY Mitsubishi Electric Europe B.V. UK Branch Travellers Lane, Hatfield, Herts., AL10 8XB,UK Mitsubishi Electric Europe B.V. Italian Branch Centro Dir. Colleoni, Pal. Perseo - Ingr.2 Via Paracelso 12, 20041 Agrate B., Milano, Italy Mitsubishi Electric Europe B.V. Spanish Branch Pol. Ind. "Can Magi"- C/.Joan Buscalla, 2-4-A.C.420 08190 Sant Cugat del Valles, Barcelona, Spain MSA Manufacturing (Pty) Ltd. P O Box 39733 Bramley 201 8 Johannesburg, South Africa Ryoden International Ltd. 10th Floor, Manulife Tower, 169 Electric Road, North Point, HongKong Ryoden International Shanghai Ltd. 3F Block5 Building Automation Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China Setsuyo Enterprise Co., Ltd. 6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang, Taipei Hsine, Taiwan R.O.C. HAN NEUNG TECHNO CO.,LTD. 1F Dong Seo Game Channel Bldg., 660-11,Deungchon-dong Kangsec-ku, Seoul, Korea Mitsubishi Electric Asia Pte, Ltd. 307 ALEXANDRA ROAD #05-01/02, MITSUBISHI ELECTRIC BUILDING SINGAPORE 159943 F. A. Tech Co.,Ltd. 898/28,29,30 S.V.CITY BUILDING,OFFICE TOWER 2,FLOOR 17-18 RAMA 3 ROAD,BANGKPONGPANG,YANNAWA,BANGKOK 10120 P.T. Autoteknindo SUMBER MAKMUR JL. MUARA KARANG SELATAN BLOK A UTARA NO.1 KAV. NO.11 KAWASAN INDUSTRI/ PERGUDANGAN JAKARTA - UTARA 14440 Messung Systems Put,Ltd. Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,PUNE-411026 Mitsubishi Electric Australia Pty. Ltd. 348 Victoria Road, PostalBag, No 2, Rydalmere, N.S.W 2116, Australia
Tel/Fax Tel : 1-847-478-2100 Fax : 1-847-478-0328 Tel : 55-21-221-8343 Fax : 55-21-221-9388 Tel : 49-2102-486-0 Fax : 49-2102-486-717 Tel : 44-1707-276100 Fax : 44-1707-278695 Tel : 39-039-6053301 Fax : 39-039-6053312 Tel : 34-935-653135 Fax : 34-935-891579 Tel Fax Tel Fax Tel Fax Tel Fax Tel Fax : 27-11-444-8080 : 27-11-444-8304 : 852-2887-8870 : 852-2887-7984 : 86-21-6475-3228 : 86-21-6484-6996 : 886-2-2299-2499 : 886-2-2299-2509 : 82-2-3668-6567 : 82-2-3664-8335
Tel : 65-473-2480 Fax : 65-476-7439 Tel : 66-2-682-6522 Fax : 66-2-682-6020 Tel : 62-21-663-0833 Fax : 62-21-663-0832 Tel Fax Tel Fax : 91-20-7128927 : 91-20-7128108 : 61-2-9684-7777 : 61-2-9684-7245
HEAD OFFICE:MITSUBISHI DENKI BLDG MARUNOUCHI TOKYO 100-8310 TELEX:J24532 CABLE MELCO TOKYO
00 (MEE)