0% found this document useful (0 votes)
92 views

Null

This document contains 6 certificates issued by JC International Limited certifying that visual examinations and magnetic particle inspections were performed on various air winches and lifting equipment onboard the Sedneth 701. Each certificate provides details of the equipment inspected, examiner qualifications, inspection method, parts examined, and findings that no defects were found and equipment was fit for use. Inspections were performed on October 22, 2012 and next examinations are due by April 21, 2013.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views

Null

This document contains 6 certificates issued by JC International Limited certifying that visual examinations and magnetic particle inspections were performed on various air winches and lifting equipment onboard the Sedneth 701. Each certificate provides details of the equipment inspected, examiner qualifications, inspection method, parts examined, and findings that no defects were found and equipment was fit for use. Inspections were performed on October 22, 2012 and next examinations are due by April 21, 2013.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 15

JC International Limited

RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83516

Date of Examination 22/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

MW004173

A Steel Construction Air Winch (Ingesolrand Force 5) in Dimension 1.5mtrs X 0.55mtrs X 1.17mtrs (Length X Width X Height)fitted with 16mm wire rope sling c/w Close Spelter Socket at one end. Tare WT: N/A SWL: 2 t Gross WT: N/A Date of Next Examination: 21-04-13

LOCATION: MOON POOL PORT FWD


SPECIFICATION : ASTM E 1444, BS MA31 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas and Entire Body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83517

Date of Examination 22/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

MAN RIDER AIR WINCH

CAT 080618

A Steel Construction Man Rider Air Winch (Ram Winch) in Dimension 1.06mtrs X 0.76mtrs X 1.16mtrs (Length X Width X Height) c/w 10mm wire rope sling Tare WT: N/A SWL: 150 kg Gross WT: N/A

Date of Next Examination: 21-04-13

LOCATION: MOON POOL PORT FWD


SPECIFICATION : ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas and Entire Body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83518

Date of Examination 22/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

A2451102

A Steel Construction Air Winch Guide line #1 (Ingersol Rand) in Dimension 2.04mtrs X 1.04mtrs X 1.2mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3.8 t Gross WT: N/A

Date of Next Examination: 21-04-13

COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL PORT FWD GUIDE LINE # 1
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83519

Date of Examination 22/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

7073

A Steel Construction Air Winch Pod Line Tensioner # 5 in Dimension 2mtrs X 1.05mtrs X 1.45mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3.5 t Gross WT: N/A Date of Next Examination: 21-04-13

COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL FWD PODLINE TENSIONER # 5
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Name of Inspector: SUNDAY ANYEBE Conducting Examination Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83520

Date of Examination 22/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

A3941098

A Steel Construction Air Winch Guide Line # 2 (Ingersol Rand) in Dimension 1.67mtrs X 1.05mtrs X 1.2mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3 t Gross WT: N/A Date of Next Examination: 21-04-13

COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL STBD FWD GUIDE LINE # 2
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83521

Date of Examination 24/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

ME510R1675

A Steel Construction Air Winch in Dimension 2.2mtrs X 1.07mtrs X 1.65mtrs (Length X Width X Height) Tare WT: N/A SWL: 3.5 t Gross WT: N/A Fitted with 19mm Single leg wire rope sling c/w Close spelter socket at one end other end plain fitted to the Winch

Sling#: Q451751

SWL: 4.6 t
Date of Next Examination: 23-04-13

LOCATION: PORT AFT MOON POOL


SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83522

Date of Examination 23/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

AIR WINCH

A014251

A Steel Construction Air Winch (Ingersol Rand) in Dimension 2.1mtrs X 0.92mtrs X 1.64mtrs (Length X Width X Height) Tare WT: N/A SWL: 5 t Gross WT: N/A

Sling#: CTWW 01

Fitted with 19mm Single leg wire rope sling c/w Close spelter socket at one end other end plain fitted to the Winch

SWL: 4.6 t
Date of Next Examination: 22-04-13

COMMENT: DERATE THE SWL OF AIR WINCH FROM 5 TE TO 4.5TE INSTALLE WIRE ROPE GUARD BEFORE NEXT INSPECTION LOCATION: CATWALK (PIPE DECK AREA)
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Name of Inspector: SUNDAY ANYEBE Conducting Examination Conducting: Examination only Revision No: 01 Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No. 83523

Date of Examination 23/10/2012

Examiner

Qualifications LEEA, SNT LEVEL II MT, PT & UT

SUNDAY ANYEBE

Identification Number

Description of Equipment

MAN RIDER AIR WINCH

CAT 080612

A Steel Construction Man Rider Air Winch in Dimension 1mtr X 0.87mtrs X 1.03mtrs (Length X Width X Height) c/w 10mm Wire Rope Sling Tare WT: N/A SWL: 150kg Gross WT: N/A Date of Next Examination: 22-04-13

COMMENT: NDT ONLY ON THE WELDED BASE. LOCATION: MOON POOL STBD AFT
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020

Wet Visible

CONTRAST MEDIA: INDICATOR:

White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held: Sedneth 701

Transocean Support Services

We hereby certify that on 23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83484 Identification Number Qty

21/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

A013424

Air Winch (Ingersol Rand) in Dimension 1.8m X 0.9m X 1.17m (Length X Width X Height) SWL: 5MT

Sling #: A013424/1

1pc

Fitted with 20mm Single leg sling c/w close spelter socket at one end fitted the winch SWL: 5tonnes

Date of next Examination: 20/04/13 LOCATION: STBD SIDE MAIN DECK FWD COMMENT: INSTALL WIRE ROPE GUARD
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body and Welded Base RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 21/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83485 Identification Number Qty

21/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

A013425

Air Winch (Ingersol Rand) in Dimension 1.8m X 0.9m X 1.17m (Length X Width X Height) SWL: 5MT

Sling #: A013425/1

1pc

Fitted with 20mm Single leg sling c/w close spelter socket at one end plain fitted to the winch SWL: 5tonnes

Date of next Examination: 20/04/13 LOCATION: PORT SIDE MAIN DECK FWD COMMENT: INSTALL WIRE ROPE GUARD
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body and Welded Base RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 21/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83486 Identification Number Qty

31/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

MW008992

Air Winch (Ingersol Rand) in Dimension 1.6m X 0.9m X 1.02m (Length X Width X Height) SWL: 4.5tonnes

Sling #: DFWW 01

1pc

Fitted with 19mm Single leg sling c/w close spelter socket at one end plain fitted to the winch SWL: 4.6tonnes

Date of next Examination: 30/04/13 LOCATION: RIG FLOOR AFT COMMENT: NO ACCESS FOR NDT (MPI) INSPECTION ON THE WELDED BASE
SPECIFICATION : BS MA 31, EN 970, BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83487 Identification Number Qty

31/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

701 8344-1

Hydraulic Man Rider Winch (HYDRA MARINE) in Dimension 1.6m X 1m X 1.25m (Length X Width X Height) SWL: 150kg

Sling #: 5T/2071

1pc

Fitted with 10mm Single leg sling c/w thimble eye at one end and other end plain fitted to the winch SWL: 1.582TE

Date of next Examination: 30/04/13 LOCATION: PORT SIDE RIG FLOOR


SPECIFICATION : BS MA 31, BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A

PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-V-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83488 Identification Number Qty

31/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

CAT 080520

Man Rider Air Winch in Dimension 1.3m X 0.8m X 1.3m (Length X Width X Height) SWL: 150kg

Sling #: 5T/2375

1pc

Fitted with 10mm Single leg sling c/w thimble eye at one end and other end plain fitted to the winch SWL: 1.582TE

Date of next Examination: 30/04/13 LOCATION: STBD SIDE RIG FLOOR


SPECIFICATION : ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Welded Area & Entire Body RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83489 Identification Number Qty

31/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

MW1140402

Air Winch (Ingersol Rand) in Dimension 1.63m X 0.80m X 1.10m (Length X Width X Height) SWL: 4.5TE

Sling #: DFWW 02

1pc

Fitted with 19mm Single leg sling c/w close spelter socket fitted to the winch SWL: 4.6TE

Date of next Examination: 30/04/13 LOCATION: STBD SIDE RIG FLOOR COMMENT: DERATE THE SWL OF THE AIR WINCH FROM 5TE TO 4.5TE
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body and Welded Area RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only

Revision No: 01

Doc No: JCI-C-VMPI-01

JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998

Certificate No.

Date of Examination

Examiner

Qualifications

83490 Identification Number Qty

31/10/2012

SUNDAY ANYEBE

LEEA, SNT LEVEL II MT, PT & UT

Description of Equipment AIR WINCH

MW009017

Air Winch (Force5) in Dimension 1.5m X 1m X 1.2m (Length X Width X Height) SWL: 4.5TE

Sling #: DFWW 03

1pc

Fitted with 19mm Single leg sling c/w close spelter socket fitted to the winch SWL: 4.6TE

Date of next Examination: 30/04/13 LOCATION: PORT RIG FLOOR COMMENT: DERATE THE SWL OF THE WINCH FROM 5TE TO 4.5TE
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink

PARTS EXAMINED: Entire Body and Welded Area RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner:

Address of premises where Test / Examination was held:

TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only