Null
Null
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
MW004173
A Steel Construction Air Winch (Ingesolrand Force 5) in Dimension 1.5mtrs X 0.55mtrs X 1.17mtrs (Length X Width X Height)fitted with 16mm wire rope sling c/w Close Spelter Socket at one end. Tare WT: N/A SWL: 2 t Gross WT: N/A Date of Next Examination: 21-04-13
Wet Visible
PARTS EXAMINED: Welded Areas and Entire Body RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
CAT 080618
A Steel Construction Man Rider Air Winch (Ram Winch) in Dimension 1.06mtrs X 0.76mtrs X 1.16mtrs (Length X Width X Height) c/w 10mm wire rope sling Tare WT: N/A SWL: 150 kg Gross WT: N/A
Wet Visible
PARTS EXAMINED: Welded Areas and Entire Body RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
A2451102
A Steel Construction Air Winch Guide line #1 (Ingersol Rand) in Dimension 2.04mtrs X 1.04mtrs X 1.2mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3.8 t Gross WT: N/A
COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL PORT FWD GUIDE LINE # 1
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
7073
A Steel Construction Air Winch Pod Line Tensioner # 5 in Dimension 2mtrs X 1.05mtrs X 1.45mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3.5 t Gross WT: N/A Date of Next Examination: 21-04-13
COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL FWD PODLINE TENSIONER # 5
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Name of Inspector: SUNDAY ANYEBE Conducting Examination Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
A3941098
A Steel Construction Air Winch Guide Line # 2 (Ingersol Rand) in Dimension 1.67mtrs X 1.05mtrs X 1.2mtrs (Length X Width X Height) c/w 19mm wire rope sling with close spelter socket Tare WT: N/A SWL: 3 t Gross WT: N/A Date of Next Examination: 21-04-13
COMMENT: MPI only on the accessible welded base The wire rope is tension and not inspected
LOCATION: MOON POOL STBD FWD GUIDE LINE # 2
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 22/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Revision No: 01 Name of Inspector: SUNDAY ANYEBE Conducting: Examination only Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
ME510R1675
A Steel Construction Air Winch in Dimension 2.2mtrs X 1.07mtrs X 1.65mtrs (Length X Width X Height) Tare WT: N/A SWL: 3.5 t Gross WT: N/A Fitted with 19mm Single leg wire rope sling c/w Close spelter socket at one end other end plain fitted to the Winch
Sling#: Q451751
SWL: 4.6 t
Date of Next Examination: 23-04-13
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 24/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
AIR WINCH
A014251
A Steel Construction Air Winch (Ingersol Rand) in Dimension 2.1mtrs X 0.92mtrs X 1.64mtrs (Length X Width X Height) Tare WT: N/A SWL: 5 t Gross WT: N/A
Sling#: CTWW 01
Fitted with 19mm Single leg wire rope sling c/w Close spelter socket at one end other end plain fitted to the Winch
SWL: 4.6 t
Date of Next Examination: 22-04-13
COMMENT: DERATE THE SWL OF AIR WINCH FROM 5 TE TO 4.5TE INSTALLE WIRE ROPE GUARD BEFORE NEXT INSPECTION LOCATION: CATWALK (PIPE DECK AREA)
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Name of Inspector: SUNDAY ANYEBE Conducting Examination Conducting: Examination only Revision No: 01 Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Examiner
SUNDAY ANYEBE
Identification Number
Description of Equipment
CAT 080612
A Steel Construction Man Rider Air Winch in Dimension 1mtr X 0.87mtrs X 1.03mtrs (Length X Width X Height) c/w 10mm Wire Rope Sling Tare WT: N/A SWL: 150kg Gross WT: N/A Date of Next Examination: 22-04-13
COMMENT: NDT ONLY ON THE WELDED BASE. LOCATION: MOON POOL STBD AFT
SPECIFICATION : BSMA 31, ASTM E 1444 MPI METHOD: TEST PROCEDURE: JOP-020
Wet Visible
PARTS EXAMINED: Welded Areas RESULTS: No defect as at the time of inspection. Fit for use
We hereby certify that on 23/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use. Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
21/10/2012
SUNDAY ANYEBE
A013424
Air Winch (Ingersol Rand) in Dimension 1.8m X 0.9m X 1.17m (Length X Width X Height) SWL: 5MT
Sling #: A013424/1
1pc
Fitted with 20mm Single leg sling c/w close spelter socket at one end fitted the winch SWL: 5tonnes
Date of next Examination: 20/04/13 LOCATION: STBD SIDE MAIN DECK FWD COMMENT: INSTALL WIRE ROPE GUARD
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
PARTS EXAMINED: Entire Body and Welded Base RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 21/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
21/10/2012
SUNDAY ANYEBE
A013425
Air Winch (Ingersol Rand) in Dimension 1.8m X 0.9m X 1.17m (Length X Width X Height) SWL: 5MT
Sling #: A013425/1
1pc
Fitted with 20mm Single leg sling c/w close spelter socket at one end plain fitted to the winch SWL: 5tonnes
Date of next Examination: 20/04/13 LOCATION: PORT SIDE MAIN DECK FWD COMMENT: INSTALL WIRE ROPE GUARD
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
PARTS EXAMINED: Entire Body and Welded Base RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 21/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
31/10/2012
SUNDAY ANYEBE
MW008992
Air Winch (Ingersol Rand) in Dimension 1.6m X 0.9m X 1.02m (Length X Width X Height) SWL: 4.5tonnes
Sling #: DFWW 01
1pc
Fitted with 19mm Single leg sling c/w close spelter socket at one end plain fitted to the winch SWL: 4.6tonnes
Date of next Examination: 30/04/13 LOCATION: RIG FLOOR AFT COMMENT: NO ACCESS FOR NDT (MPI) INSPECTION ON THE WELDED BASE
SPECIFICATION : BS MA 31, EN 970, BS EN 13414-2 MPI METHOD: N/A TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
31/10/2012
SUNDAY ANYEBE
701 8344-1
Hydraulic Man Rider Winch (HYDRA MARINE) in Dimension 1.6m X 1m X 1.25m (Length X Width X Height) SWL: 150kg
Sling #: 5T/2071
1pc
Fitted with 10mm Single leg sling c/w thimble eye at one end and other end plain fitted to the winch SWL: 1.582TE
PARTS EXAMINED: Entire Body RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
31/10/2012
SUNDAY ANYEBE
CAT 080520
Man Rider Air Winch in Dimension 1.3m X 0.8m X 1.3m (Length X Width X Height) SWL: 150kg
Sling #: 5T/2375
1pc
Fitted with 10mm Single leg sling c/w thimble eye at one end and other end plain fitted to the winch SWL: 1.582TE
PARTS EXAMINED: Welded Area & Entire Body RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
31/10/2012
SUNDAY ANYEBE
MW1140402
Air Winch (Ingersol Rand) in Dimension 1.63m X 0.80m X 1.10m (Length X Width X Height) SWL: 4.5TE
Sling #: DFWW 02
1pc
Fitted with 19mm Single leg sling c/w close spelter socket fitted to the winch SWL: 4.6TE
Date of next Examination: 30/04/13 LOCATION: STBD SIDE RIG FLOOR COMMENT: DERATE THE SWL OF THE AIR WINCH FROM 5TE TO 4.5TE
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
PARTS EXAMINED: Entire Body and Welded Area RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com
Certificate No.
Date of Examination
Examiner
Qualifications
31/10/2012
SUNDAY ANYEBE
MW009017
Air Winch (Force5) in Dimension 1.5m X 1m X 1.2m (Length X Width X Height) SWL: 4.5TE
Sling #: DFWW 03
1pc
Fitted with 19mm Single leg sling c/w close spelter socket fitted to the winch SWL: 4.6TE
Date of next Examination: 30/04/13 LOCATION: PORT RIG FLOOR COMMENT: DERATE THE SWL OF THE WINCH FROM 5TE TO 4.5TE
SPECIFICATION : BS MA 31, ASTM E 1444, BS EN 13414-2 MPI METHOD: Wet Visible TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
PARTS EXAMINED: Entire Body and Welded Area RESULTS: No defect as at the time of inspection. Fit for use
TRANSOCEAN SUPPORT SERVICE SEDNETH 701 We hereby certify that on 31/10/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: SUNDAY ANYEBE Conducting: Examination only
Revision No: 01