0% found this document useful (0 votes)
71 views1 page

Grounding and Shielding

1) It is important to consider noise abatement when designing electronic equipment to avoid electromagnetic interference issues. 2) The best way to prevent noise is through proper grounding and shielding design from the beginning, rather than trying to fix problems later. 3) Signals that could cause cross-coupling noise issues, such as a data line near a power output, should have individual shields surrounding each conductor grounded at both ends.

Uploaded by

shaomin_liang89
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
71 views1 page

Grounding and Shielding

1) It is important to consider noise abatement when designing electronic equipment to avoid electromagnetic interference issues. 2) The best way to prevent noise is through proper grounding and shielding design from the beginning, rather than trying to fix problems later. 3) Signals that could cause cross-coupling noise issues, such as a data line near a power output, should have individual shields surrounding each conductor grounded at both ends.

Uploaded by

shaomin_liang89
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

910E.OrangefairLaneAnaheim,CA92801USA 8003459401www.AnaheimAutomation.

com

GroundingandShieldingTips
ItiswisetospendtimetounderstandthecouplingmechanismsofelectricalnoisethatcreatesElectro MagneticInterference(EMI)whenbuildingelectronicequipment.Itisadvisabletoplanamethodof noiseabatementduringthedesignandbuildingofamachine,ratherthantryingtoproblemsolveEMI issuesoncethemachineisbuilt. Toavoidelectricalnoiseissues,allaspectsofthemachinedesignmustbetakenintoconsideration.The bestprocessisplanningforthebestgroundingmethod.Whenthebestgroundingmethodsarenot achieved,improvedgroundingandshieldingmethodsmustbeusedinstead.Anexampleisapower outputconnectionthatismagneticallycrosscoupledtothedatalinefromaservocontroller.Inthis instance,thedatalinehashighspeednoise,potentiallycausinganoiseproblem.Thedatalinemustbe singleendedorthedifferentialoutputwillrejectthenoise.Therefore,thebestmethodtoavoidcross couplingistotakeboththesourceandthereceiverintoconsideration.Ensurethetwosignalsarelaid outsoindividualconductorsaresurroundedbyamagneticshield,groundedonbothends.Shielding boththeemittersandthereceiverisrecommendedifthecablecannotberelocated. Itispreferredthatthegroundsareneartheinputsandoutputsattheendsofthesignal.Ifthiscannot bedone,abraidedshieldgroundedatoneendisrecommendedovernoshieldatall! UnterminatedshieldswithPWMsignalsaspowerfulasaservocontrollershouldnotbeused. Understandingcouplingmechanismsisextremelybeneficial,especiallyinasituationwherethepotential ofcapacitivelycouplinghighrisetimeispresent. Itisnecessarytogroundthemagneticshield;howeverlowfrequencycansometimesresultinthe generationofcurrentsintwogroundpointsbetweensingleendedsignalscalledgroundloops.A commonalternativethatdoesnotresultintheredesignofasystemisusingamultishieldconnector. Theoutershieldisgroundedatbothendsandtheinnershieldisgroundreferencedatthesourceofthe signal.