Strobe Lights

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Visual Signaling Devices Steady On Beacons, Rotating Beacons and Flashing Strobe Lights

Luminaires for Hazardous and Non-Hazardous Locations


Description

11L

Page No. 940 941 942, 944, 949 943, 944, 949 945, 946, 949 947, 948, 949 950

Application VF Beacons Fluorescent Steady On EX Fire Alarm Strobe Light EX Strobe Light EX Steady-on Beacon EX Rotating Beacon VDAS Strobe Lights

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

939

11L

Visual Signaling Devices Steady On Beacons, Rotating Beacons and Flashing Strobe Lights
Luminaires for Hazardous and Non-Hazardous Locations

Application:
for use in hazardous and non-hazardous areas (as shown in the quick selector chart shown below). to supplement audible signals, especially in high noise areas. as visual signals or warning lights. to identify the location of safety equipment such as emergency shower, eye wash stations, and emergency telephones, fire extinguishers and emergency stop switches. for status indication of machinery or processes. to indicate dangerous areas or areas requiring caution. to signal dangerous or hazardous conditions.

Considerations for Selection:


Environmental: What is the hazardous area classification (NEC/CEC) of the location in which the luminaire will be installed? Signaling Requirements: What will the visual signal be used for (Communicating, alerting, warning)? Physical Arrangements: Type of luminaire mounting needed.

Quick Selector Chart: Series VF - Steady On Beacons EX Strobes, Steady-On Beacons, & Rotating Beacons VDAS Strobes Hazardous Area Suitability CL. I, Div 2, Groups A, B, C, D CL. I, Zone 2, Group IIC Wet Locations - 3, 3R Cl. I, Div. I, Groups C,D Cl. I, Zone 1 & 2, Group IIB Cl. II, Div. I, Groups E,F,G Wet Locations - 4X, Marine CL. I, Div 2, Groups A, B, C, D CL. I, Zone 2, Group IIC CL. II, Div 2, Groups F, G; Cl. III Wet Locations - 3, 3R, 4, 4X Lamp Watts (2) 9W Volts 120V 60 Hz. No. of Lamps 2

Xenon Strobe Halogen Beacon Xenon Strobe

120 VAC 24 VDC 12-48 VDC 24-28 VDC 120V 60 Hz 240V 60 Hz 12-24VDC

Warning and Visual Indication Colors Available Green Blue Red Yellow Clear

Typical Uses Emergency Shower or Eye Wash Station Emergency Telephones Danger, Equipment Operating Caution Equipment end of cycle

940

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

VF Steady On Beacon
Compact Fluorescent Warning and Visual Indication Light
Application:
VF series Steady On fluorescent beacons are used indoors or outdoors: where the energy efficiency and long life of compact fluorescent lamps are desired for continuous signaling requirements. where a continuous Steady-On fluorescent light signal is required where ambient noise makes audible signals difficult to hear. as visual signals or warning lights on loading docks; at obstructions, exits or entrances. for identifying the location of safety equipment such as safety showers or emergency telephones. for call signals. for status indication or area lighting on offshore rigs, mines, refineries etc. in locations which are hazardous due to the presence of flammable vapors or gases and where dampness or corrosion are present. to identify a potentially dangerous obstacle. as a continuous source to warn or communicate. Typical Applications are: Green - Identify safety shower locations Blue - Identify emergency telephones Amber - Caution signal Red - Danger signal Red & Amber - Emergency situations Blue & Red - Security or malfunctioning equipment. Green & Clear - Equipment end of cycle.

Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Groups IIC Wet Locations 3, 3R

Green - Safety Shower Blue - Emergency Telephones Red - Danger Amber - Warning Visual Signal Options:
Description 250 volt Nameplate for export applications

11L

Suffix added to Cat. No. /250 2-Lamp Luminaire With Globe & Guard (lbs.) 5 514 712

Weights:
Luminaire Type VFA VFHF VFHBF

Temperature Performance Data:


Style 1 & 2 Class I Lamp Div. 2 9W T3B Max. Ambient 40C Supply Wire C 75C Minimum Operating 4C (25F)

Certifications and Compliances:


NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2 UL Standards 844 1598 Luminaires CSA standards c22.2 No. 137

Features:
Extremely energy efficient, only 18 watt (2-9 watt compact fluorescent lamps) Packs considerable punch for ample visibility even in harsh enviroments. Compact size and light weight allow adaptation and easy installation in many industrial applications Cast copper-free aluminum (less than 0.4 of 1% copper) construction and epoxy powder finish provide excellent resistance to corrosion Variety of mounting arrangements to suit any lighting layout pendant, ceiling, wall bracket, angle stanchion. Glass globes are internally fluted and stippled to enhance visibility. Exteriors are smooth to shed dust Grounding wire for safety

Dimensions
Pendant Wall Stanchion

VFA Ceiling

VFHBF

VFHA

Standard Materials:
Bodies and guards copper-free aluminum (less than 0.4 of 1%) Globes glass

Standard Finishes:
Copper-free aluminum powder epoxy finish

VFHF

Ordering Information:
Style Red
Pendant Wall Ceiling Stanchion VFA222GRP VFHBF222GRP VFHF222GRP VFHA422GRP

Electrical Ratings:
Input voltage 120 VAC, 60 hertz Wattages: 18W (Two 9W lamps)

Catalog Number - by Globe Color Amber Green Blue


VFA222GAP VFHBF222GAP VFHF222GAP VFHA422GAP VFA222GGP VFHBF222GGP VFHF222GGP VFHA422GGP VFA222GBP VFHBF222GBP VFHF222GBP VFHA422GBP

Clear
VFA222GP VFHBF222GP VFHF222GP VFHA422GP

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

941

11L

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Fire Alarm Strobe Light

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 1971 Listed NEMA 4X watertight, IP 66

The Hazard Gard TM EXFASC Series is a visual fire alarm signaling device for hazardous areas. The EXFASC Series strobes are UL 1971 Listed for indoor signaling applications for the hearing impaired in non-sleeping areas. They are also UL listed for Type 3R, 4X installations. The strobes are available for pendant, wall and ceiling mounts. The EXFASC Series Fire Alarm Explosionproof Strobe contains a supervisory diode for use in fire alarm applications. Under normal operation the diode is reversed biased, meaning it blocks voltage from being applied to the strobe light and prevents it from lighting. When a fire-initiating device such as a smoke alarm is activated, the diodes polarity is reversed through a fire alarm panel. The diode becomes forward biased, allowing voltage to the device and activating the strobe.

Primary Applications
Visual fire alarm signaling device for hazardous areas

Certifications and Compliances


Petrochemical plants Petroleum refineries Oil rigs Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E, F & G Class III UL 1638 and 1203 Listed UL 1971 Listed for indoor visual signaling for the hearing impaired in non-sleeping areas cUL Listed C22.2 No. 205 NEMA 4X watertight, IP 66

Typical Industries
Energy exploration Utilities Wastewater treatment plants Pulp & paper plants

Key Features and Benefits


Meets NFPA requirements for fire safety warning devices. State of the art electronic design (full wave rectified design). - Low current draw is efficient. - 24VDC regulated full wave rectified - Limited in-rush current favorable to other fire alarm system components. - Proven, reliable circuitry designed specifically for use with fire alarm control panels. Available in pendant, wall and ceiling mount. Strobe light produces 65 flashes per minute. Factory sealed no external seals required. Quick connect Strobe fixture threads onto mounting module for easy installation. Small compact size ceiling mount is 1334-inch long.

Materials & Finishes


Body, mounting modules and guard Copper-free aluminum Globe Heat and impact-resistant glass Gaskets Silicone External hardware Stainless steel Internal components Solid-state electronics in a moistureresistant and heat-dissipating epoxy Epoxy powder coated for corrosion resistance

Ratings
16-33VDC Operating Current: 1.08 - 0.83 amps Peak Candlepower: 800,000

Hub Size
3/4-inch NPT pendant, ceiling and wall mount

Ordering Information STEP 1 Order Strobe Type


Catalog Lens NEMA Number Voltage Color Rating FIRE ALARM RATED EXPLOSIONPROOF STROBES EXFASC301/16 33 24VDC regulated Clear 3R, 4X full wave rectified

STEP 2 Order Mounting Module


Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 34 34 34 114 Mounting Style Pendant Wall Ceiling Stanchion

Temperature Performance Data


See page 944.

942

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Strobe Light

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed (120VAC and 24VDC only) NEMA 4X watertight, IP 66

11L

Cooper Crouse-Hinds Hazard Gard EXS and EXDS Series Explosionproof Strobe Lights are designed for installation indoors and outdoors in locations which are hazardous due to the presence of flammable vapors or gases, ignitible dusts or ignitible fibers and flyings. The units are UL listed for Type 3R and 4X installations. The 120V and 24VDC models are Marine Rated. The strobes are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. The EXDS Series is diode polarized for use in electrically supervised circuits. Electrically supervised circuits are typically used in life-safety or security applications. Under normal operation the diode is reversed biased, meaning it blocks voltage from being applied to the strobe and prevents it from lighting. When an initiating device such as a smoke detector is activated, the diodes polarity is reversed through a circuit panel. The diode becomes forward biased, allowing voltage to the device and activating the strobe.

Primary Applications
Condition signaling Equipment obstruction warning Security alert Emergency evacuation signaling In areas where audible signals cannot be heard

Certifications and Compliances


Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E, F & G Class III UL and cUL 1638, UL 1203 and UL 844 Listed 1598A Marine Listed (120VAC and 24VDC only) cUL Listed C22.2 No. 205 NEMA 4X watertight, IP 66

Typical Industries
Utility gas plants Wastewater treatment plants Mining Petroleum refineries Chemical & petrochemical Pulp & paper

Key Features and Benefits


Strong strobe signal that produces 65 flashes per minute. Compact design will not obstruct in low ceiling or small areas. Ceiling mount is only 1334-inch long. Quick connect Strobe fixture threads onto mounting module for easy installation. Factory sealed No external seals required. Available in pendant, wall, stanchion and ceiling mount. Available in six different globe colors clear, red, blue, amber, green and magenta. Silicone gasket seals out dirt and moisture.

Materials & Finishes


Body, mounting modules and guard Copper-free aluminum Globe Heat and impact-resistant glass Gaskets Silicone External hardware Stainless steel Internal components Solid-state electronics in a moistureresistant and heat-dissipating epoxy Epoxy powder coated for corrosion resistance

Ratings
120VAC (EXS), 1248VDC (EXSNM) and 24VDC nominal, voltage operating range is 1633VDC (EXDS) Operating Current: 0.10 amps at 120VAC 1.23.8 amps at 1248VDC 0.8 amps at 24VDC Peak Candlepower: 800,000

Hub Size
3/4-inch NPT pendant, ceiling and wall mount 114-inch NPT stanchion mount

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

943

11L

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Strobe Light

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed (120VAC and 24VDC only) NEMA 4X watertight, IP 66

Ordering Information STEP 1 Order Strobe Type


Catalog Number Voltage EXPLOSIONPROOF STROBES EXS301A/120 120VAC EXS301B/120 120VAC EXS301C/120 120VAC EXS301G/120 120VAC EXS301M/120 120VAC EXS301R/120 120VAC EXSNM301A/12 48 1248VDC EXSNM301B/12 48 1248VDC EXSNM301C/12 48 1248VDC EXSNM301G/12 48 1248VDC EXSNM301M/12 48 1248VDC EXSNM301R/12 48 1248VDC Lens Color Amber Blue Clear Green Magenta Red Amber Blue Clear Green Magenta Red NEMA Rating 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X 3R, 4X 3R, 4X 3R, 4X 3R, 4X 3R, 4X

STEP 2 Order Mounting Module


Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 34 34 34 114 Mounting Style Pendant Wall Ceiling Stanchion

DIODE POLARIZED EXPLOSIONPROOF STROBES EXDS301A/24 24VDC Amber EXDS301B/24 24VDC Blue EXDS301C/24 24VDC Clear EXDS301G/24 24VDC Green EXDS301M/24 24VDC Magenta EXDS301R/24 24VDC Red

3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine

Temperature Performance Data


Ambient Max. Temp. 40C 55C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85C) T5(100C) Class II, Class III Div. 1 Group E, F, G T4A(120C) T4(135C) Class II, Class III Div. 2 Group F, G T4A(120C) T4(135C)

EXFASC Series Fire Alarm Voltage 24VDC Regulated Full Wave Rectified (Operating Range 16-33VDC) (Marine Listed)

Supply Wire 75C 90C

EXS Series Strobe Light Voltage 120VAC (Marine Listed)

40C 55C 65C

75C 90C 105C

T6(85C) T6(85C) T6(85C)

T4A(120C) T4(135C) T4(135C)

T4A(120C) T4(135C) T4(135C)

EXSNM Series Strobe Light Voltage 12-48 VDC (Not Marine Listed)

40C 55C 65C

75C 90C 105C

T6(85C) T6(85C) T6(85C)

T4A(120C) T4(135C) T4(135C)

T4A(120C) T4(135C) T4(135C)

EXDS Series Strobe Light-Diode Polarized Voltage 24 VDC (Marine Listed)

40C 55C

75C 90C

T6(85C) T5(100C)

T4A(120C) T4(135C)

T4A(120C) T4(135C)

944

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Steady-On Beacons

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

11L

Cooper Crouse-Hinds Hazard Gard EXSO and EXDSO (Diode Polarized) Series Explosionproof Steady On Beacons are designed for installation in hazardous locations where a visual signal is required for tough environmental conditions involving corrosives, water, dust and extreme temperature. The units are UL listed for Type 3R, 4X and marine installations. The steady-on beacons are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. Typical industrial and commercial applications include food processing plants, refineries, mines, tankers, laboratories, sewage treatment plants, off-shore oil rigs, water and filtration plants and chemical plants. The diode polarized steady-on beacon is used in electrically supervised circuitry for life-safety or security applications.

Primary Applications
Safety lighting Continuous source to Exit or entrance lights communicate Obstacle warning For identifying the location of safety equipment such as showers or emergency telephones

Certifications and Compliances


Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E, F & G Class III UL and cUL 1638, UL 1203 and UL 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

Typical Industries
Chemical plants Storage handling Dust conveyor systems Energy exploration Textile mills Flour and feed mills

Materials & Finishes


Body, mounting modules and guard Copper-free aluminum Globe Heat and impact-resistant glass Gaskets Silicone External hardware Stainless steel Internal components Solid-state electronics in a moistureresistant and heat-dissipating epoxy Epoxy powder coated for corrosion resistance

Key Features and Benefits


Powerful halogen light source for clear visual indication. Available in six different globe colors amber, blue, clear, green, magenta and red. Factory sealed no external seals required. Quick connect Steady-on beacon fixture threads onto mounting module for easy installation. Small compact size ceiling mount is 1334-inch long. Available in pendant, wall, stanchion and ceiling mount.

Ratings
120VAC and 2428VDC Operating Current: 0.35 amps at 120VAC (EXSO) 0.8 amps at 2428VDC (EXDSO, diode polarized) Peak Candlepower: 3328

Hub Size
3/4-inch NPT pendant, ceiling and wall mount 114-inch NPT stanchion mount

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

945

11L

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Steady-On Beacons

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

Ordering Information STEP 1 Order Steady-On Beacon Type


Catalog Lens Number Voltage Color EXPLOSIONPROOF STEADY-ON BEACONS EXSO301A/120 120VAC Amber EXSO301B/120 120VAC Blue EXSO301C/120 120VAC Clear EXSO301G/120 120VAC Green EXSO301M/120 120VAC Magenta EXSO301R/120 120VAC Red NEMA Rating 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine

STEP 2 Order Mounting Module


Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 34 34 34 114 Mounting Style Pendant Wall Ceiling Stanchion

DIODE POLARIZED EXPLOSIONPROOF STEADY-ON BEACONS EXDSO301A/24 28 2428VDC Amber 3R, 4X, Marine EXDSO301B/24 28 2428VDC Blue 3R, 4X, Marine EXDSO301C/24 28 2428VDC Clear 3R, 4X, Marine EXDSO301G/24 28 2428VDC Green 3R, 4X, Marine EXDSO301M/24 28 2428VDC Magenta 3R, 4X, Marine EXDSO301R/24 28 2428VDC Red 3R, 4X, Marine

Temperature Performance Data


Ambient Max. Temp. 40C 55C 65C 40C 55C 65C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85C) T5(100C) T5(100C) T6(85C) T6(85C) T6(85C) Class II, Class III Div. 1 Group E, F, G T4A(120C) T4(135C) T4(135C) T4A(120C) T4(135C) T4(135C) Class II, Class III Div. 2 Group F, G T4A(120C) T4(135C) T4(135C) T4A(120C) T4(135C) T4(135C)

EXSO Series Steady-On Beacon Voltage 120VAC EXDSO Series Steady-On Beacon Diode Polarized Voltage 24-28 VDC

Supply Wire 75C 90C 105C 75C 90C 105C

946

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Rotating Beacons

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

11L

Cooper Crouse-Hinds Hazard Gard EXR Series Explosionproof Rotating Beacons are designed for installation in hazardous locations, such as manufacturing plants, heavy industrial facilities, refineries, chemical, petrochemical, pharmaceutical and off-shore drilling platforms. The units are UL listed for Type 3R, 4X and marine installations. The rotating beacons are available for pendant, wall, stanchion and ceiling mounts, and come in six different globe colors. The EXDR Series Explosionproof Rotating Beacon is diode polarized for use in standard 2428VDC electrical circuits or in electrically supervised circuits. Electrically supervised circuits are typically used in life-safety or security applications. Under normal operation in an electrically supervised circuit, the diode is reversed biased, meaning it blocks voltage from being applied to the rotating beacon and prevents it from lighting. When a warning detecting device is activated, the diodes polarity is reversed through a circuit panel. The diode becomes forward biased, allows voltage to the device and activates the rotating beacon.

Primary Applications
Security alert Obstacle warning Areas under construction or off limits Equipment obstruction warning Status indication of a process Supplement audible signaling

Certifications and Compliances


Class I, Division 1, Groups C & D Class II, Division 1, Groups E, F & G Class I, Zone 1 & 2, Group IIB Class III UL and cUL 1638, UL 1203 and UL 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

Typical Industries
Utility gas plants Wastewater treatment plants Chemical plants Pharmaceutical plants Refineries Mining

Materials & Finishes


Body, mounting modules and guard Copper-free aluminum Globe Heat and impact-resistant glass Gaskets Silicone External hardware Stainless steel Internal components Solid-state electronics in a moistureresistant and heat-dissipating epoxy Epoxy powder coated for corrosion resistance

Key Features and Benefits


Powerful halogen rotating beacon emits bright light to provide critical visual warning. Available in pendant, wall, stanchion and ceiling mount. Available in six different globe colors amber, blue, clear, green, magenta and red. Beacon produces 75 rotations per minute. Factory sealed No external seals required. Quick connect Strobe fixture threads onto mounting module for easy installation.

Ratings
120VAC (EXR) and 2428VDC (EXDR) Operating Current: 0.382 amps at 120VAC 0.8 amps at 2428VDC Peak Candlepower: 3328 (EXR) 2838 (EXDR)

Hub Size
34-inch NPT pendant, ceiling and wall mount 114-inch NPT stanchion mount

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

947

11L

Hazard Gard EX Series Visual Signaling Devices


Explosionproof Rotating Beacons

Class I, Division 1, Groups C & D Class I, Zone 1 & 2, Group IIB Class II, Division 1, Groups E,F,G Class III UL 1638, 1203 and 844 Listed 1598A Marine Listed NEMA 4X watertight, IP 66

Ordering Information STEP 1 Order Rotating Beacon Type


Catalog Lens Number Voltage Color EXPLOSIONPROOF ROTATING BEACONS EXR301A/120 120VAC Amber EXR301B/120 120VAC Blue EXR301C/120 120VAC Clear EXR301G/120 120VAC Green EXR301M/120 120VAC Magenta EXR301R/120 120VAC Red NEMA Rating 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine 3R, 4X, Marine

STEP 2 Order Mounting Module


Catalog Number EVMP2 EV22 & EV87 EV22 EVMJ4 Hub Size 34 34 34 114 Mounting Style Pendant Wall Ceiling Stanchion

DIODE POLARIZED EXPLOSIONPROOF ROTATING BEACONS EXDR301A/24 28 2428VDC Amber 3R, 4X, Marine EXDR301B/24 28 2428VDC Blue 3R, 4X, Marine EXDR301C/24 28 2428VDC Clear 3R, 4X, Marine EXDR301G/24 28 2428VDC Green 3R, 4X, Marine EXDR301M/24 28 2428VDC Magenta 3R, 4X, Marine EXDR301R/24 28 2428VDC Red 3R, 4X, Marine

Temperature Performance Data


Ambient Max. Temp. 40C 55C 65C 40C 55C 65C Class I Div. 1, 2 Group C, D Class I, Zone 1 Group II B T6(85C) T5(100C) T5(100C) T6(85C) T6(85C) T6(85C) Class II, Class III Div. 1 Group E, F, G T4A(120C) T4(135C) T4(135C) T4A(120C) T4(135C) T4(135C) Class II, Class III Div. 2 Group F, G T4A(120C) T4(135C) T4(135C) T4A(120C) T4(135C) T4(135C)

EXR Series Rotating Beacon Voltage 120VAC EXDR Series Rotating Beacon Diode Polarized Voltage 24-28 VDC

Supply Wire 75C 90C 105C 75C 90C 105C

948

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

Hazard Gard EX Series Visual Signaling Devices


Dimensions & Weights

11L

Stanchion Mount

NET LUMINAIRE WEIGHTS


Luminaire Housing with Guard 11.0 lbs. 1.0 lbs. 1.0 lbs. 4.5 lbs. 2.5 lbs.

Add mounting modules Pendant Ceiling Wall Stanchion

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

949

11L

VDAS Strobe Lights


Warning and Visual Indication

Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zone 2, Group IIC Cl. II, Div 2, Groups F, G; Cl. III

Wet Locations 3, 3R, 4, 4X

Application:
VDAS strobe lights are used: in areas with high noise levels to visually indicate warnings or hazards

CSA Enclosure 3, 4, 5 Replacement Parts


Electronic Strobe Subassembly (includes flash tube): 120 VAC. . . . . . . . . . . . . . . . . . . . . . CHTFI-120H 240 VAC . . . . . . . . . . . . . . . . . . . . . CHTFI-240H 12 VDC . . . . . . . . . . . . . . . . . . . . . . . . CHTFI-012 24 VDC. . . . . . . . . . . . . . . . . . . . . . . . CHTFI-024 Flash Tube . . . . . . . . . . . . . . . . . . . . . . . . RSTC Globe Assembly Clear . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/C Red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/R Green . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/G Amber . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/A Blue. . . . . . . . . . . . . . . . . . . . . . . . . . . . . VDAG/B

Features:
Reliable solid state components. Compact enclosure design provides 60 high intensity flashes per minute. Choice of globe colors to meet various requirements. Gasketed to seal out dirt and liquids. Designed for globe up or globe down applications. Easy to install. Lightweight corrosion-resistant copper-free aluminum construction. Conduit locking hub for increased safety and security.

Standard Materials:
Body copper-free aluminum Globe LEXAN fresnel lens

Standard Finishes:
Body gray epoxy

Ordering Information
Globe Color Red Blue Amber Green Clear Pendant Hub Size 34 34 34 34 34 Cat. # 120 VAC VDAS/R VDAS/B VDAS/A VDAS/G VDAS/C Cat. # 240 VAC VDAS/R/240 VDAS/B/240 VDAS/A/240 VDAS/G/240 VDAS/C/240 Cat. # 12 VDC VDAS/R/012 VDAS/B/012 VDAS/A/012 VDAS/G/012 VDAS/C/012 Cat. # 24 VDC VDAS/R/024 VDAS/B/024 VDAS/A/024 VDAS/G/024 VDAS/C/024

Size Range:
34

conduit

Certifications and Compliances:


NEC and CEC: Class I, Division 2, Groups A, B, C, D Class I, Zone 2, IIC UL Standards 844 1598 Luminaires CSA Standards C22.2 No. 137

Temperature Performance Data:


Ambient C 40 55 65 Class I Div 2 T3B T3A T3 Class II Div 2, Class III T3B -----

Dimensions

Electrical Ratings:
120, 240 VAC 50/60 Hz 12, 24 VDC

Photometric Data, Clear Globe


Peak flash 3.45 million candlepower Effective candlepower (light intensity if light is burning steadily) 201 ECP

Photometric Data:
Globe Color Output Intensity Clear . . . . . . . . . . . . . . . . . . . . . . . 201 ECP Red . . . . . . . . . . . . . . . . . . . . . . . . . 46 ECP Amber. . . . . . . . . . . . . . . . . . . . . . 152 ECP Blue. . . . . . . . . . . . . . . . . . . . . . . . . 38 ECP Green . . . . . . . . . . . . . . . . . . . . . . . 38 ECP

Operating Current:
Voltage 120 VAC 240 VAC 12 VDC 24 VDC Operating Current .3A .15A .9A .45A

950

US: 1-866-764-5454 CAN: 1-800-265-0502

Copyright 2006 Cooper Crouse-Hinds

You might also like