Honeywell Alarmnet Internet Connectivity Test
Honeywell Alarmnet Internet Connectivity Test
Honeywell Alarmnet Internet Connectivity Test
-1-
Step-by-Step
2. The window does blank out but when you type a bunch of characters and hit <ENTER> you get an HTTP-type long error page. There is likely a PROXY server between the computer being used to TELNET and the Internet. In general, our equipment wont work behind a Proxy, but there may be some network engineering that can be done at the site to work around this, depending on the equipment being used. While our units were designed to work behind Firewalls and usually require no additional ports to be opened, there are some networks that use security measures that will prevent our units from working, these may include: ! ! ! ! Proxy Servers Stateful Packet Inspection (SPI) Packet or IP filtering Any software that attempts to open or look inside our encrypted data packets.
The customer could contact their network administrator and inform them that our IP addresses need to be excluded from SPI and/or PROXY. Our IP addresses are listed below: Redir 1 ................ 204.141.57.100 (auiredir1.alarmnet.com) {ports 80, 443} Redir 2 ................ 204.141.57.101 (auiredir2.alarmnet.com) {ports 80, 443} Redir 3 ................ 204.141.57.102 (auiredir3.alarmnet.com) {ports 80, 443} Redir A................ 12.149.218.73 (auiredirA.alarmnet.com) {ports 80, 443} Control Server ..... 204.141.58.115 (controlserver.alarmnet.com) {ports 80, 443} Data Server1 ....... 204.141.58.80 (dataserver1.alarmnet.com) {ports 80, 443} Data Server2 ....... 204.141.58.81 (dataserver2.alarmnet.com) {ports 80, 443} Video Server .. 204.141.56.75 (video.alarmnet.com) {ports 80, 443, 8061} Video File Server.. 199.61.12.74 (files.alarmnet.com) {ports 80, 443} Redir IP Address for Reporting The IP Addresses below are used for alarm reporting. These can be tested using the 7720P programmer via Network Diagnostics; Shift {F}. They should also be excluded from SPI and/or PROXY. Redir Redir Redir Redir 1 ................ 204.141.57.100 (auiredir1.alarmnet.com) 2 ................ 204.141.57.101 (auiredir2.alarmnet.com) 3 ................ 204.141.57.102 (auiredir3.alarmnet.com) A................ 12.149.218.73 (auiredirA.alarmnet.com)
-2-
Step-by-Step
To test the data server (for Compass Connect and/or Optiflex troubleshooting) you will also need to test the Dataserver public IP address (204.141.58.80) as described above.
Note: If you try telnet 12.149.218.2 80 from inside the Honeywell network, you will see the failure described in #2 above.
Compass now allows you to change the Port that is uses. This setting is found in the download.ini file. Port 443 is the port used for secure web browsing (https://). These internet based devices send to AlarmNet servers at IP addresses 204.141.57.100, 101, and 102. Application code is downloaded on Port 8001. Static or DHCP Settings AlarmNet Internet products can use either DHCP or Static IP addressing. If problems occur due to automatic IP releasing on the network, the AlarmNet device should be switched to a Static IP. If static IPs are being used, the following information is needed from the Network Administrator before installation: ! ! ! !
*
Static IP address for the AlarmNet device Subnet Mask Default Gateway DNS IP Address
Automatic IP Releasing: AlarmNet Internet products ping AlarmNet every 20 seconds to verify connectivity; therefore, it releases the previously assigned IP address at the end of its session and requests a new one each time it checks connectivity.