Signet Tech-Tips

Number: 105 Date Issued: 01/13/2012

Title: Upgrading from 8550 to 9900


This Tech-Tip will describe what is required to upgrade an existing 8550 Transmitter installation to the new Signet 9900 Smart ProTM Transmitter.

Sensor Compatibility The 9900 Transmitter is compatible with all GF Signet flow sensors (515, 525, 2000, 2100, 2507, 2536, 2537, 2540, 2551, and 2552). Signet flow sensors 515, 525, 2000, 2100, 2507, 2536 and 2540 provide a frequency output. (Flow sensors 2551 and 2552 can be configured with either Digital (S3L) or Frequency outputs). Depending on the sensor configuration, the 9900 Transmitter can be configured for a frequency or S3L signal. 515, 525 and 2536 can be run on Loop Power. All other flow sensors require DC power. Upgrading from an 8550 panel mount installation to the 9900 requires no mechanical changes to the sensors. There are, however, wiring differences. Please refer to the 9900 manual at www.gfsignet.com for sensor wiring instructions for your application.

Panel Mount Installations Upgrading from an 8550 panel mount installation to the 9900 requires no mechanical changes to the enclosure. There are, however, wiring differences. Please refer to the 9900 manual at www.gfsignet.com for power wiring instructions for your application. 8550 Mfr. Part No. 3-8550-1P 9900 Mfr. Part No. 3-9900-1P Panel Base Unit 3-9900-1P Panel Base Unit and 3-9900.393 Relay Module Not Available Code(s) 159 001 695 159 001 695 and 159 001 698 Requires 3-9900.393 Relay Module Notes

3-8550-2P

3-8550-3P

Field Mount Installations The 9900 Field Mount Transmitter is only available with an open collector output. The Relay Module is not compatible with the 9900 Field Mount Transmitter. The 9900 Field Mount Transmitter can utilize an existing 8050, 8051 or 8052 field enclosure. GF Signet also offers an Angle Adapter 3-9900.396 (159 001 701) for use with these field enclosures. 8550 Mfr. Part No. 3-8550-1 9900 Mfr. Part No. 3-9900-1 Field Base Unit Code(s) 159 001 696 Must use 3-9900-1P panel mount version with 3-9900.393 Relay Module For field installations use 3-9900.392 wall mount accessory 3-8550-3 Not Available Notes

3-8550-2

Not Available

If you have any questions or need further information, please contact your local Georg Fischer Sales Office or visit us on the web at www.gfsignet.com.

Georg Fischer Signet LLC 3401 Aerojet Avenue, El Monte, CA 91731-2882 U.S.A. www.gfsignet.com E-mail: [email protected] Copyright 2012 Georg Fischer Signet LLC Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.