Hilti HIT-RE 500
with HAS
Hilti HIT-RE 500 with HAS-(E) / HAS-(E)R / HIT-V*
Injection mortar system
Benefits
Hilti
HIT-RE 500
330 ml foil pack
(also available
as 500 ml
and 1400 ml
foil pack)
Statik mixer
HAS-(E) rod
HAS-(E)R rod
HAS-HCR
- suitable for non-cracked concrete
- high loading capacity
- suitable for dry and water
saturated concrete
- under water application
- large diameter applications
- high corrosion resistant
- long working time at elevated
temperatures
- odourless epoxy
- embedment depth range:
from 40 160 mm for M8
to 120 600 mm for M30
HIT-V rod
* Special request only, please contact Hilti Service Hotline for information
Concrete
Small edge
distance
and spacing
Variable
embedment
depth
Fire
resistance
Corrosion
resistance
High
corrosion
resistance
European
Technical
Approval
CE
conformity
Hilti anchor
design
software
Approvals / certificates
Description
European technical approval a)
Authority / Laboratory
DIBt, Berlin
Fire test report
IBMB, Braunschweig
Assessment report (fire)
warringtonfire
No. / date of issue
ETA-04/0027 / 2009-05-20
UB 3565 / 4595 / 2006-10-29
UB 3588 / 4825 / 2005-11-15
WF 166402 / 2007-10-26 & suppl.
WF 172920 / 2008-05-27
a) All data given in this section according ETA-04/0027, issue 2009-05-20.
Basic loading data (for a single anchor)
All data in this section applies to
For details see Simplified design method
- Correct setting (See setting instruction)
- No edge distance and spacing influence
- Steel failure
- Base material thickness, as specified in the table
- One typical embedment depth, as specified in the table
- One anchor material, as specified in the tables
- Concrete C 20/25, fck,cube = 25 N/mm
- Temperature range I
(min. base material temperature -40C, max. long term/short term base material temperature: +24C/40C)
- Installation temperature range +5C to +40C
240
2 / 2011
Hilti HIT-RE 500
with HAS
Embedment depth a) and base material thickness for the basic loading data.
Characteristic resistance, design resistance, recommended loads.
Anchor size
M8 M10 M12 M16 M20 M24
Typical embedment depth [mm]
80
90
110 125 170 210
Base material thickness [mm]
110 120 140 165 220 270
a) The allowed range of embedment depth is shown in the setting details. The
calculated according to the simplified design method.
M27 M30 M33 M36 M39
240 270 300 330 360
300 340 380 410 450
corresponding load values can be
Characteristic resistance: concrete C 20/25 , anchor HAS rod
Data according ETA-04/0027, issue 2008-11-03
Anchor size
M8
M10
M12
M16
[kN]
17,0
26,0
38,0
70,6 111,9 153,7 187,8 224,0 262,4 302,7 344,9
[kN]
8,5
13,0
19,0
36,0
HAS-ER (A4)
[kN]
23,0
37,0
53,0
70,6 111,9 153,7 187,8 224,0 262,4 302,7 344,9
HAS-ER (A4)
[kN]
12,0
19,0
27,0
51,0
HAS-E
a)
Shear VRd
HAS-E
a)
Tensile NRd
Shear VRd
Tensile NRd
M20
56,0
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
80,0 174,0 211,0 258,7 303,6 365,2
79,0 112,0 108,0 132,0 161,6 189,6 226,1
Design resistance: concrete C 20/25 , anchor HAS rod
Data according ETA-04/0027, issue 2008-11-03
Anchor size
M30
Additional Hilti
technical data
M33 M36 M39
M8
M10
M12
M16
M20
M24
M27
Tensile NRd
HAS-E
a)
[kN]
11,3
17,3
25,3
33,6
53,3
73,2
89,4 106,7 125,0 144,2 164,3
Shear VRd
HAS-E
a)
[kN]
6,8
10,4
15,2
28,8
44,8
64
139,2 168,8 207,0 242,9 292,2
Tensile NRd
HAS-ER (A4)
[kN]
12,3
19,8
28,3
33,6
53,3
73,2
89,4 106,7 125,0 144,2 164,3
Shear VRd
HAS-ER (A4)
[kN]
7,7
12,2
17,3
32,7
50,6
71,8
45,8
55,5
67,9
79,7
95,9
Recommended loads a): concrete C 20/25, anchor HAS rod
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
[kN]
5,7
8,7
12,7
23,5
37,3
51,2
62,6
74,7
87,5 100,9 115,0
[kN]
2,8
4,3
6,3
12,0
16,7
26,7
70,3
70,3
86,2 101,2 121,7
[kN]
7,7
12,3
17,7
23,5
37,3
51,2
62,6
74,6
87,5 100,9 115,0
Data according ETA-04/0027, issue 2008-11-03
Anchor size
HAS-E
a)
Shear VRd
HAS-E
a)
Tensile NRd
HAS-ER (A4)
Tensile NRd
Shear VRd
HAS-ER (A4) [kN]
4,0
6,3
9,0 17,0 26,3 37,3 36,0 44,0 53,9 63,2 75,4
a) The standard delivery program for HAS-E anchor rod: Grade 5.8 for HAS-E M8-M24, Grade 8.8 for M27-M39.
b) With overall global safety factor J = 3. The recommended loads vary according to the safety factor requirement
from national regulations.
2 / 2011
241
Hilti HIT-RE 500
with HAS
Service temperature range
Hilti HIT-RE 500 injection mortar may be applied in the temperature ranges given below. An elevated base material
temperature may lead to a reduction of the design bond resistance.
Maximum long term
base material
temperature
+24 C
+35 C
+43 C
Base material
temperature
Temperature range
Temperature range I
Temperature range II
Temperature range III
-40 C to +40 C
-40 C to +58 C
-40 C to +70 C
Maximum short term
base material
temperature
+40 C
+58 C
+70 C
Max short term base material temperature
Short-term elevated base material temperatures are those that occur over brief intervals, e.g. as a result of
diurnal cycling.
Max long term base material temperature
Long-term elevated base material temperatures are roughly constant over significant periods of time.
Materials
Mechanical properties of HIT-V / HAS
HIT-V/HAS 5.8
HIT-V/HAS 8.8
HIT-V/HAS -R
HIT-V/HAS -HCR
HIT-V/HAS 5.8
HIT-V/HAS 8.8
HIT-V/HAS -R
HIT-V/HAS -HCR
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
[N/mm]
M8
500
800
700
800
400
640
450
600
M10
500
800
700
800
400
640
450
600
M12
500
800
700
800
400
640
450
600
M16
500
800
700
800
400
640
450
600
M20
500
800
700
800
400
640
450
600
M24
500
800
700
700
400
640
450
400
M27
500
800
500
700
400
640
210
400
M30
500
800
500
700
400
640
210
400
Additional Hilti
technical data
M33 M36 M39
500 500 500
800 800 800
500 500 500
500 500 500
400 400 400
640 640 640
210 210 210
250 250 250
HAS
[mm]
32,8
52,3
76,2
144
225
324
427
519
647
759
913
HIT-V
[mm]
36,6
58,0
84,3
157
245
353
459
561
694
817
976
HAS
[mm]
27,0
54,1
93,8
244
474
809
1274 1706 2321 2949 3891
HIT-V
[mm]
31,2
62,3
109
277
541
935
1387 1874 2579 3294 4301
Data according ETA-04/0027, issue 2008-11-03
Anchor size
Nominal
tensile
strength fuk
Yield
strength fyk
Stressed
crosssection As
Moment of
resistance
W
242
2 / 2011
Hilti HIT-RE 500
with HAS
Material quality
Part
Threaded rod
HIT-V(F),
HAS 5.8 M8 M24
Threaded rod
HIT-V(F),
HAS 8.8 M27 M39
Material
Strength class 5.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Strength class 8.8, EN ISO 898-1, A5 > 8% ductile
steel galvanized 5 m, EN ISO 4042
(F) hot dipped galvanized 45 m, EN ISO 10684
Stainless steel grade A4, A5 > 8% ductile
strength class 70 for M24 and class 50 for M27 to M30, EN ISO 3506-1,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
High corrosion resistant steel, EN ISO 3506-1, EN 10088: 1.4529; 1.4565
strength M20: Rm = 800 N/mm, Rp 0.2 = 640 N/mm, A5 > 8% ductile
M24 to M30: Rm = 700 N/mm, Rp 0.2 = 400 N/mm, A5 > 8% ductile
Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684
Stainless steel, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439;
1.4362
High corrosion resistant steel, EN 10088: 1.4529; 1.4565
Strength class 8, ISO 898-2
steel galvanized 5 m, EN ISO 4042
hot dipped galvanized 45 m, EN ISO 10684
Strength class 70, EN ISO 3506-2, stainless steel grade A4,
EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362
Strength class 70, EN ISO 3506-2, high corrosion resistant steel,
EN 10088: 1.4529; 1.4565
Threaded rod
HIT-V-R, HAS-R
Threaded rod
HIT-V-HCR, HAS-HCR
Washer
ISO 7089
Nut
EN ISO 4032
Anchor dimensions
M39
M39x360
M36
M36x330
M33
M33x300
M30
M30x270
M27
M27x240
M24
M24x210
M20
M20x170
[mm]
M16
M16x125
Anchor embedment depth
M12
M12x110
Anchor rod
HAS, HAS-E,
HAS-R, HAS-ER
HAS-HCR
M10
M10x90
M8
M8x80
Anchor size
80
90
110
125
170
210
240
270
300
330
360
Anchor rod
HIT-V, HIT-V-R, HIT-V-HCR
Anchor rods HIT-V (-R / -HCR) are available in variable length
Setting
installation equipment
Anchor size
Rotary hammer
Other tools
Additional
Hilti recommended tools
2 / 2011
M8
M10
M12
M16
M20
M24
M27
M30
TE2 TE16
TE40 TE70
compressed air gun or blow out pump, set of cleaning brushes, dispenser
DD EC-1, DD 100 DD xxx
a)
243
Hilti HIT-RE 500
with HAS
Setting instruction
Dry and water-saturated concrete, hammer drilling
a)
Brush bore hole with required steel brush HIT-RB
a) Note: Manual cleaning only for hef 250 mm and anchor size M16
For detailed information on installation see instruction for use given with the package of the product.
244
2 / 2011
Hilti HIT-RE 500
with HAS
Water filled bore hole or submerged, hammer drilling
Brush bore hole with required steel brush HIT-RB
2 / 2011
245
Hilti HIT-RE 500
with HAS
Dry and water-saturated concrete, diamond coring drilling; Hilti technical information only
To comply with ETA requirement, anchors in diamond drilled holes load values for
combined pull-out and concrete cone resistance have to be reduced. Please
contact Hilti technical advisory for details.
246
2 / 2011
Hilti HIT-RE 500
with HAS
Curing time for general conditions
Data according ETA-04/0027, issue 2009-05-20
Temperature
Curing time before
of the
anchor can be fully
base material
loaded tcure
40 C
4h
30 C to 39 C
8h
20 C to 29 C
12 h
15 C to 19 C
24 h
10 C to 14 C
48 h
5 C to 9 C
72 h
Additional Hilti technical data
Temperature
Working time in which
of the
anchor can be inserted
base material
and adjusted tgel
40 C
12 min
30 C
20 min
20 C
30 min
15 C
1h
10 C
2h
5 C
2h
For dry concrete curing times may be reduced according to the following table.
For installation temperatures below +5 C all load values have to be reduced according to
the load reduction factors given below.
Curing time for dry concrete
Additional Hilti technical data
Temperature
of the
base material
40 C
30 C
20 C
15 C
10 C
5 C
0 C
-5 C
2 / 2011
Reduced curing time
before anchor can be
fully loaded tcure,dry
4h
8h
12 h
18 h
24 h
36 h
50 h
72 h
Working time in which
anchor can be inserted
and adjusted tgel
12 min
20 min
30 min
1h
2h
2h
3h
4h
Load reduction factor
1
1
1
1
1
1
0,7
0,6
247
Hilti HIT-RE 500
with HAS
Setting details
Data according ETA-04/0027, issue 2009-05-20
Anchor size
Nominal diameter of
drill bit
Effective anchorage
and drill hole depth
a)
range
Minimum base
material thickness
Diameter of clearance
hole in the fixture
Minimum spacing
Minimum edge
distance
Critical spacing for
splitting failure
Critical edge distance
b)
for splitting failure
Critical spacing for
concrete cone failure
Critical edge distance
for concrete cone
c)
failure
d)
Torque moment
M8
M10
M12
M16
M20
M24
M27
M30
Additional Hilti
technical data
M33 M36 M39
d0
[mm]
10
12
14
18
24
28
30
35
37
40
42
hef,min
[mm]
40
40
48
64
80
96
108
120
132
144
156
hef,max
[mm]
160
200
240
320
400
480
540
600
660
720
780
hmin
[mm]
df
[mm]
12
14
18
22
26
30
33
36
39
42
smin
[mm]
40
50
60
80
100
120
135
150
165
180
195
cmin
[mm]
40
50
60
80
100
120
135
150
165
180
195
270
300
330
360
390
hef + 30 mm
100 mm
hef + 2 d0
scr,sp
ccr,sp
2 ccr,sp
[mm]
1,0 hef
for h / hef
4,6 hef - 1,8 h
for 2,0 > h / hef > 1,3:
2,26 hef
for h / hef
2,0
1,3:
scr,N
2 ccr,N
ccr,N
1,5 hef
Tmax
[Nm]
10
20
40
80
150
200
For spacing (edge distance) smaller than critical spacing (critical edge distance) the design loads have to be
reduced.
hef
hef,max (hef: embedment depth)
a)
hef,min
b)
h: base material thickness (h
c)
The critical edge distance for concrete cone failure depends on the embedment depth hef and the design bond
resistance. The simplified formula given in this table is on the save side.
d)
This is the maximum recommended torque moment to avoid splitting failure during installation for anchors with
minimum spacing and/or edge distance.
248
hmin)
2 / 2011
Hilti HIT-RE 500
with HAS
Simplified design method
Simplified version of the design method according ETAG 001, TR 029. Design resistance
according data given in ETA-04/0027, issue 2009-05-20.
Influence of concrete strength
Influence of edge distance
Influence of spacing
Valid for a group of two anchors. (The method may also be applied for anchor groups
with more than two anchors or more than one edge distance. The influencing factors
must then be considered for each edge distance and spacing. The calculated design
loads are then on the save side: They will be lower than the exact values according
ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software
PROFIS anchor)
The design method is based on the following simplification:
No different loads are acting on individual anchors (no eccentricity)
The values are valid for one anchor.
For more complex fastening applications please use the anchor design software PROFIS Anchor.
Tension loading
The design tensile resistance is the lower value of
- Steel resistance:
NRd,s
- Combined pull-out and concrete cone resistance:
0
NRd,p = N Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
0
- Concrete cone resistance: NRd,c = N
-
Rd,c
fB f1,N f2,N f3,N fh,N fre,N
Concrete splitting resistance (only non-cracked concrete):
0
NRd,sp = N Rd,c fB f1,sp f2,sp f3,sp fh,N fre,N
Basic design tensile resistance
Design steel resistance NRd,s
JMs 1.5
Data according ETA-04/0027, issue 2009-05-20
Anchor size
HAS-E 5.8
HIT-V 5.8
HAS-E 8.8
NRd,s HIT-V 8.8
HAS (-E)-R
HIT-V-R
HAS (-E)-HCR
2 / 2011
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
11,3
12,0
19,3
12,3
13,9
18,0
M10
17,3
19,3
30,7
19,8
21,9
28,0
M12
25,3
28,0
44,7
28,3
31,6
40,7
M16 M20 M24 M27 M30
48,0 74,7 106,7
52,7 82,0 118,0 153,3 187,3
231,3 281,3
84,0 130,7 188,0 244,7 299,3
54,0 84,0 119,8 75,9 92,0
58,8 92,0 132,1 80,4 98,3
76,7 120,0 106,7 144,8 175,7
Additional Hilti
technical data
M33 M36 M39
231,3 272,3 325,3
345,1 404,8 486,9
370,1 435,7 520,5
113,2 132,8 159,8
122,6 144,3 172,4
134,8 158,1 190,2
249
Hilti HIT-RE 500
with HAS
Design combined pull-out and concrete cone resistance
NRd,p = N0Rd,p fB,p f1,N f2,N f3,N fh,p fre,N
JMp 1.8
Data according ETA-04/0027, issue 2009-05-20
Additional Hilti
technical data
M33 M36 M39
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30
Typical embedment depth
80
90
110 125 170 210 240 270 300 330
hef,typ [mm]
0
N Rd,p Temperature range I
[kN] 15,3 21,5 31,6 44,9 76,3 105,6 135,7 157,5 171,0 203,3
0
N Rd,p Temperature range II [kN] 12,4 17,5 25,7 35,9 61,0 82,9 106,6 133,3 136,8 162,6
0
N Rd,p Temperature range III [kN]
7,7 10,8 15,8 22,4 35,6 52,8 63,0 78,8 82,1 97,6
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for combined pull-out and concrete cone resistance may be increased by 20 % for
installation in dry concrete (concrete not in contact with water before/during installation and curing).
Design concrete cone resistance a) NRd,c = N0Rd,c fB f1,N f2,N f3,N fh,N fre,N
Design splitting resistance NRd,sp a) = N0Rd,c fB f1,sp f2,sp f3,sp f h,N fre,N
360
232,9
186,3
111,8
anchor
JMc 1.8
Additional Hilti
Data according ETA-04/0027, issue 2009-05-20
technical data
Anchor size
M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
0
N Rd,c
[kN] 17,2 20,5 27,7 33,6 53,3 73,2 89,4 106,7 125,0 144,2 164,3
a) Additional Hilti technical data (not part of ETA-04/0027, issue 2009-05-20):
The design values for concrete cone and splitting resistance may be increased by 20 % for anchor installation
in dry concrete (concrete not in contact with water before/during installation and curing).
Influencing factors
Influence of concrete strength on combined pull-out and concrete cone resistance
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
0,1 a) b)
fB,p = (fck,cube/25N/mm)
1
1,02
1,04
1,06
1,07
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service
C 45/55
C 50/60
1,08
1,09
Influence of embedment depth on combined pull-out and concrete cone resistance
fh,p = hef/hef,typ
Influence of concrete strength on concrete cone resistance
Concrete strength designation
(ENV 206)
1/2 a)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
fB =
(fck,cube/25N/mm)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service
250
C 45/55
C 50/60
1,48
1,55
2 / 2011
Hilti HIT-RE 500
with HAS
Influence of edge distance a)
c/ccr,N
c/ccr,sp
f1,N =
0,7 + 0,3c/ccr,N
f1,sp = 0,7 + 0,3c/ccr,sp
f2,N =
0,1
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
0,73
0,76
0,79
0,82
0,85
0,88
0,91
0,94
0,97
0,5(1 + c/ccr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f2,sp = 0,5(1 + c/ccr,sp)
a) The the edge distance shall not be smaller than the minimum edge distance cmin given in the table with the
setting details. These influencing factors must be considered for every edge distance smaller than the critical
edge distance.
Influence of anchor spacing a)
s/scr,N
0,1
s/scr,sp
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
f3,N =
0,5(1 + s/scr,N)
0,55 0,60 0,65 0,70 0,75 0,80 0,85 0,90 0,95
1
f3,sp = 0,5(1 + s/scr,sp)
a) The anchor spacing shall not be smaller than the minimum anchor spacing smin given in the table with the
setting details. This influencing factor must be considered for every anchor spacing.
Influence of embedment depth on concrete cone resistance
fh,N = (hef/hef,typ)1,5
Influence of reinforcement
hef [mm]
40
a)
50
60
a)
a)
70
80
a)
a)
90
100
a)
fre,N = 0,5 + hef/200mm 1
0,7
0,75
0,8
0,85
0,9
0,95
1
a) This factor applies only for dense reinforcement. If in the area of anchorage there is reinforcement with a
spacing 150 mm (any diameter) or with a diameter 10 mm and a spacing 100 mm, then a factor fre = 1
may be applied.
Shear loading
The design shear resistance is the lower value of
- Steel resistance:
-
Concrete pryout resistance:
- Concrete edge resistance:
2 / 2011
VRd,s
VRd,cp = k lower value of NRd,p and NRd,c
0
VRd,c = V
Rd,c
fB f f h f4 f hef fc
251
Hilti HIT-RE 500
with HAS
Basic design shear resistance
Design steel resistance VRd,s
JMs = Vary according to ETA
Data according ETA-04/0027, issue 2009-05-20
Anchor size
HAS-E 5.8
HIT-V 5.8
HAS-E 8.8
HIT-V 8.8
VRd,s
HAS-ER
HIT-V-R
HAS (-E)-HCR
HIT-V-HCR
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
[kN]
M8
6,8
7,2
12,0
7,7
8,3
10,4
12,0
M10
10,4
12,0
18,4
12,2
12,8
16,8
18,4
M12
15,2
16,8
27,2
17,3
19,2
24,8
27,2
M16
28,8
31,2
50,4
32,7
35,3
46,4
50,4
M20 M24 M27 M30
44,8 64,0
48,8 70,4 92,0 112,0
139,2 168,8
78,4 112,8 147,2 179,2
50,6 71,8 45,8 55,5
55,1 79,5 48,3 58,8
72,0 64,0 86,9 105,7
78,4 70,9 92,0 112,0
Additional Hilti
technical data
M33 M36 M39
138,8 163,4 195,2
207,0 242,9 292,2
222,1 261,4 312,3
67,9 79,7 95,9
72,9 85,8 102,5
80,9 94,9 114,1
86,8 102,1 122,0
Design concrete pryout resistance VRd,cp = lower valuea) of k NRd,p and k NRd,c
k = 1 for hef < 60 mm
k = 2 for hef 60 mm
a)
NRd,p: Design combined pull-out and concrete cone resistance
NRd,c: Design concrete cone resistance
= V0Rd,c fB f f h f4 f hef fc
Design concrete edge resistance VRd,c
Anchor size
Non-cracked concrete
0
V Rd,c
[kN]
JMc = 1.5
M8
M10
M12
M16
M20
M24
M27
M30
M33
M36
M39
5,9
8,6
11,6
18,7
27,0
36,6
44,5
53,0
62,1
71,7
81,9
Influencing factors
Influence of concrete strength
Concrete strength designation
(ENV 206)
C 20/25
C 25/30
C 30/37
C 35/45
C 40/50
1/2 a)
fB =
(fck,cube/25N/mm)
1
1,1
1,22
1,34
1,41
a) fck,cube = concrete compressive strength, measured on cubes with 150 mm side length
b) For design data of fck,cube = 15 and 20, please contact Hilti technical advisory service
C 45/55
C 50/60
1,48
1,55
Influence of angle between load applied and the direction perpendicular to the free edge
Angle
10
20
30
40
50
60
70
80
90
fE
1,01
1,05
1,13
1,24
1,40
1,64
1,97
2,32
2,50
0,15
0,3
0,45
0,6
0,75
0,9
1,05
1,2
1,35
1,5
0,32
0,45
0,55
0,63
0,71
0,77
0,84
0,89
0,95
1,00
Influence of base material thickness
h/c
fh =
252
{h/(1,5 c)}
1/2
2 / 2011
Hilti HIT-RE 500
with HAS
Influence of anchor spacing and edge distance a) for concrete edge resistance: f4
f4 = (c/hef)1,5 (1 + s / [3 c]) 0,5
Group of two anchors s/hef
Single
anchor 0,75 1,50 2,25 3,00 3,75 4,50 5,25 6,00 6,75 7,50 8,25 9,00 9,75
0,50
0,35
0,27 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35 0,35
0,75
0,65
0,43 0,54 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65 0,65
1,00
1,00
0,63 0,75 0,88 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00
1,25
1,40
0,84 0,98 1,12 1,26 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40 1,40
1,50
1,84
1,07 1,22 1,38 1,53 1,68 1,84 1,84 1,84 1,84 1,84 1,84 1,84 1,84
1,75
2,32
1,32 1,49 1,65 1,82 1,98 2,15 2,32 2,32 2,32 2,32 2,32 2,32 2,32
2,00
2,83
1,59 1,77 1,94 2,12 2,30 2,47 2,65 2,83 2,83 2,83 2,83 2,83 2,83
2,25
3,38
1,88 2,06 2,25 2,44 2,63 2,81 3,00 3,19 3,38 3,38 3,38 3,38 3,38
2,50
3,95
2,17 2,37 2,57 2,77 2,96 3,16 3,36 3,56 3,76 3,95 3,95 3,95 3,95
2,75
4,56
2,49 2,69 2,90 3,11 3,32 3,52 3,73 3,94 4,15 4,35 4,56 4,56 4,56
3,00
5,20
2,81 3,03 3,25 3,46 3,68 3,90 4,11 4,33 4,55 4,76 4,98 5,20 5,20
3,25
5,86
3,15 3,38 3,61 3,83 4,06 4,28 4,51 4,73 4,96 5,18 5,41 5,63 5,86
3,50
6,55
3,51 3,74 3,98 4,21 4,44 4,68 4,91 5,14 5,38 5,61 5,85 6,08 6,31
3,75
7,26
3,87 4,12 4,36 4,60 4,84 5,08 5,33 5,57 5,81 6,05 6,29 6,54 6,78
4,00
8,00
4,25 4,50 4,75 5,00 5,25 5,50 5,75 6,00 6,25 6,50 6,75 7,00 7,25
4,25
8,76
4,64 4,90 5,15 5,41 5,67 5,93 6,18 6,44 6,70 6,96 7,22 7,47 7,73
4,50
9,55
5,04 5,30 5,57 5,83 6,10 6,36 6,63 6,89 7,16 7,42 7,69 7,95 8,22
4,75
10,35 5,45 5,72 5,99 6,27 6,54 6,81 7,08 7,36 7,63 7,90 8,17 8,45 8,72
5,00
11,18 5,87 6,15 6,43 6,71 6,99 7,27 7,55 7,83 8,11 8,39 8,66 8,94 9,22
5,25
12,03 6,30 6,59 6,87 7,16 7,45 7,73 8,02 8,31 8,59 8,88 9,17 9,45 9,74
5,50
12,90 6,74 7,04 7,33 7,62 7,92 8,21 8,50 8,79 9,09 9,38 9,67 9,97 10,26
a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing
minimum edge distance cmin.
c/hef
10,50 11,25
0,35 0,35
0,65 0,65
1,00 1,00
1,40 1,40
1,84 1,84
2,32 2,32
2,83 2,83
3,38 3,38
3,95 3,95
4,56 4,56
5,20 5,20
5,86 5,86
6,55 6,55
7,02 7,26
7,50 7,75
7,99 8,25
8,49 8,75
8,99 9,26
9,50 9,78
10,02 10,31
10,55 10,85
smin and the
Influence of embedment depth
hef/d
f hef =
1,68
0,05 (hef / d)
hef/d
f hef =
1,68
0,05 (hef / d)
4,5
10
11
0,51
0,63
0,75
1,01
1,31
1,64
2,00
2,39
2,81
12
13
14
15
16
17
18
19
20
3,25
3,72
4,21
4,73
5,27
5,84
6,42
7,04
7,67
20
30
40
0,57
0,52
0,50
Influence of edge distance a)
c/d
0,19
10
15
fc =
(d / c)
0,77
0,71
0,67
0,65
0,60
a) The edge distance shall not be smaller than the minimum edge distance cmin.
Combined tension and shear loading
For combined tension and shear loading see section Anchor Design.
2 / 2011