LINESENSE, the 6th click Pre-wired LINESENSE control unit Mounting bracket for movement detector Movement detector 1
"Philips' TTX400 trunking system with its 9 wires was the first choice for Royal Mail's new postal distribution centre in Daventry (UK), because it offered them the facility to automatically test their emergency lighting without the necessity for someone to physically walk around to inspect each emergency luminaire. A control panel allows them to check the functionality and record the results of their emergency lighting for any part of the building at any time."
Top photo: Ikea warehouse,The Netherlands. Insert: Royal Mail, United Kingdom.
1 2
10
11
Suspension brackets
Page 25
secures the section to the suspension bracket. connects the sections mechanically and electrically. mounts the electrical unit. fits the reflector to the electrical unit. connects the power supply. Trunkings
Page 14 - 15
One extra click is all thats needed if the 9 wire version is chosen. Not only does it click together in seconds, but it can be dismantled just as quickly for maintenance, changing reflectors and switching from 1 lamp to 2 lamps, and for re-routing a light line to accommodate, for example, changes in shop layout. Electrical units
Page 16 - 17
Reflectors
Page 18 - 21
Inlay reflectors
Page 18 - 19
12
TL5
TL-D
ZTX400
TTX400 5 wire
TTX400 7 wire
TTX400 9 wire
TTX400 5 wire
TTX400 7 wire
TTX400 9 wire
5 x 2.5 mm2
7 x 2.5 mm2
9 x 2.5 mm2
5 x 2.5 mm2
7 x 2.5 mm2
9 x 2.5 mm2
TMX400 1 49
TMX400 2 49
TMX40. 49
TMX400 1 58
TMX400 2 58
TMX40. 58
GMX5.. white
GMX5.. aluminium
GMX4.. white
GMX4.. aluminium
- wide beam - narrow beam - ultra narrow beam - asymmetric beam - wall washer
- wide beam - narrow beam - very narrow beam - ultra narrow beam - asymmetric beam - wall washer
GGX555 ..
GGX45. ..
- bidirectional - asymmetrical
GGX555 ..
GGX450 ..
- white louvre - flat profiled aluminium - matt parabolic lamellea - perforated louvre - mesh louvre - high-gloss parabolic lamella - semi-high-gloss parabolic lamella - prismatic panel
- white louvre - flat profiled aluminium - high-gloss parabolic lamella - matt parabolic lamella - prismatic panel
13
Trunking TL-D
Trunking sections are the basis for fast installation. One click movement establishes the mechanical and electrical connection.The length of the TL-D trunking sections perfectly matches that of the TL-D electrical units to ensure exact electrical fitting. Pre-wired trunking sections are available with 5, 7 or 9 wires. Unwired sections are also available to increase the flexibility in positioning the electrical units. Trunking sections are made of galvanized white steel.
5 wires
Trunking selection
family code TTX400 length 362 363 581 582 583 wiring 5 7 9* 9T**
Type number example:TTX400 581 7 * 9 = 7 standard flat ribbon cables + 2 standard hardcore cables ** 9T = 7 standard flat ribbon cables + 2 twisted-pair cables, to be used in communication
Dimensions
type 362 363 length A 2457 3686 type 581 582 583 length A (mm) 1528 3057 4586
125.5
63
49
packaging
Dedicated packaging with polystyrene (PS) end caps ensures stable palletisation.
ZTX400 CL Connection unit to be used for through-wiring at the end of an interrupted line.
ZTX400 EP-PHL End plate to cover the trunking. Includes knock out hole of 20 mm.
14
Trunking TL5
One click movement establishes the mechanical and electrical connection.The length of the TL5 trunking sections perfectly matches that of TL5 electrical units to ensure exact electrical fitting. Pre-wired trunking sections are available with 7 or 9 wires.Trunking sections are made of galvanized white steel.
Trunking selection
family code TTX400 length 491* 492* 493* 541** 542** 543** wiring 7*** 9**** 9T*****
Type number example:TTX400 541 7 * Length 49W = 35W = 80W ** 54W = 28W *** 2.5 mm2 flat ribbon cable **** 9 = 7 standard flat ribbon cables + 2 standard hardcore cables ***** 9T = 7 standard flat ribbon cables + 2 twisted-pair cables, to be used in communication
Dimensions
type 491 492 493 length A 1474 2949 4424 type 541 542 543 length A (mm) 1174 2348 3524
125.5
63
mains connection
ZTX400 CU Mains connection via connection unit at the beginning of the line. Fast installation ensured via the click connection. Suitable for 5 or 7 wires. Strain relief included.
49
9 wires
A. For dimming in combination with emergency lighting with a local battery. The 8th and 9th wires will be standard hard core. (9) B. For emergency lighting with a local battery in combination with testing facilities of the emergency lighting, the 8th and 9th wires will be twisted pairs, to be used for communication. (9T) C. For DALI in combination with emergency lighting with local batteries, the 8th and 9th wires will be twisted pairs, to be used for the DALI communication. (9T) D. The 9 wire solution can be extended to 11 wires on a project bases.
Alternative, more aesthetic mains connection, using a standard electrical connector. Knock outs in trunking and end caps enable the mains wires to enter the trunking. Dedicated trunking e.g. TTX400 491 CU7 with knock outs. Kit: electrical connector, end plate and 2 cable glands e.g. ZTX400 EP-CU7.
unwired trunking
Unwired trunking sections allow the electrical units to be located at any desired position.The mains can be connected using the ZTX400 TC connector. Electrical units can be connected using the ZTX400 DC connectors.The required wiring inside the trunking can be fixed with internal cable clips.The trunking is delivered with mechanical coupling pieces.The unwired trunking is available in two standard lengths:TTX410 582 and TTX410 583.
ZTX400 DC 5-pole connector for electrical units in the TTX410 to enable through-wiring.
ZTX400 TC 7-pole mains connector for the TTX410. Including strain relief.
15
Dimensions
A
type TMX400 36W TMX400 58W length A (mm) 1228 1528
2-lamp TL-D electrical unit Standard distance between the lampholders is 114 mm.
63
63
63
97
97
24 (mm)
114 (mm)
32 (mm)
97
2-lamp TL-D electrical unit F32 Distance between the lamp holders is 32 mm.This makes it possible to use it in I-lamp reflector (available in IC, HFB, HFP and HFR and EL3 versions, e.g.TMX400 2xTL-D58W HFP F32).
Contact blocks of electrical unit and trunking click into each other.
3 Phases, 3 Neutrals. Standard installations are done using 3 phases and 1 neutral. But solutions with 3 phases and 3 neutrals are possible upon request: standard trunking can be used in combination with 3 dedicated electrical unit types.
16
Dimensions
A
type TMX400 28W - 54W TMX400 35W - 49W - 80W length A (mm) 1174 1474 2-lamp TL5 electrical unit
63
63
Luminous flux at 25C ambient temperature 12.000 lm 10.000 lm 8.000 lm 6.000 lm 4.000 lm 2.000 lm 0 lm 28W 54W 28W 54W 1L 1L 2L 2L 35W 49W 80W 35W 49W 80W 1L 1L 1L 2L 2L 2L Lamp power
20 (mm) 46 (mm) 91.5 91.5
BALLAST BALLAST
Double switching In 2-lamps solutions with continuous light lines, 2 separate circuits can be created.This offers the possibility of switching both lamprows separately.This is done via master-slave (M/S) technology. Standard trunking can be used in combination with sets of dedicated M/S electrical units.Two additional connectors between the M/S units are included. Available upon request.
Blind covers are used to close the trunking in cases where no electrical unit is mounted.
17
Type number example: GGX453 2 58 M-WB * TL-D inlay reflectors are delivered separately
18
Type number example: GMX555 49 MB * the GMX555 reflectors are suitable for 1 or 2 lamps GMX555 WB Very small wide beam white reflector for general lighting. GMX555 MB White reflector with delta shape light distribution.
Type number example: GMX555 54 MB C-A20 SET * the GMX555 reflectors are suitable for 1 or 2 lamps ** TL5 inlay reflectors are delivered as a set with the GMX555 MB reflector, already mounted
Inlay reflectors are delivered as a set with the white reflectors, already mounted.
Type number example: GGX555 54 M6 * suitable for wide beam (WB) and medium beam (MB) reflectors ** suitable for medium beam (MB) reflector only
GMX430 GMX450
GMX555 WB GMX555 MB
A comparison of TL-D and TL5 reflectors shows that the TL5 reflectors are smaller. The smaller TL5 reflectors have a modern design to fit more easily into applications.
Plastic end plates Dedicated versions per reflector type e.g. ZTX400 EP-555-WB, ZTX400 EP-555-MB.
Plastic coupling piece Dedicated versions per reflector type e.g. ZTX400 CP-555-WB, ZTX400 CP-555-MB.
19
1 36 1 58 2 58
Dimensions
Narrow beam e.g. GMX465 1 58 M-NB wattage 36W 58W length A (mm) 1224 1524
GMX466 GMX465
GMX566 GMX565
GMX470
20
Dimensions
Narrow beam e.g. GMX565 1 49 M-NB wattage 35W - 49W - 80W 28W - 54W length A (mm) 1474 1174
nr. lamps 1 2
TL5 reflectors are smaller than the TL-D versions.This can be an advantage when only limited space is available (e.g. sprinkler installations)
21
Projectors
The combination of general lighting and accent lighting is especially attractive in hypermarkets and supermarkets. For these applications, the TTX400 system can be equipped with projectors.The electrical units for the projectors are simply clicked into the trunking, and can easily be replaced with a standard electrical unit for TL lamps. Dedicated electrical units are available to mount low-voltage halogen spots. More common is the use of projectors, directly clicked into a 3 circuit rail, or mounted via a spot bracket.
396
736 1528
396
(mm)
TMX407 58 3C Electrical unit with an integrated 3-circuit rail. Standard projectors can be mounted in the rail. Maximum weight of the mounted projectors is 9 kg.
164
400
400 1528
400
164
(mm)
TMX405 58-4 Electrical unit with 4 Express connection points for low-voltage halogen spots.This unit has 2 built-in 12V - 105W transformers.
389
750 1528
389
(mm)
(mm)
TMX403 58-2 Electrical unit with 2 connection points for projectors with e.g. CDM-T or SDW-T lamps.The projectors are mounted with the spot bracket on the trunking.
ZTX400 BP-SPOT Bracket for projectors with CDM-T / SDW-T lamps such as the 60800 or Monza.The bracket includes a RCS750 base plate and a cable for external electrical connection.
X,T or L -crossings
The pre-wired structure facilitates the creation of X,T or L -crossings of trunkings. The ZTX400 CPX is delivered with integrated coupling pieces, blind covers and end plates.
ZTX400 CPX
X-part
T-part
L-part
22
Linesense
With LINESENSE, TTX400 and controls are combined in one.The speed and ease of installation of TTX400 remains when LINESENSE is used. In addition, substantial energy savings up to 75% can be achieved. LINESENSE has been developed for industrial applications like warehouses. For detailed information, a dedicated LINESENSE brochure is available.
Daylight linking
Manual override
Movement detection
Dim level 3%
Switch on/off
Best performance ZTX400 MDU-D Movement detection (detector LRM 8117) Minimum light level without presence Maximum number of presence detectors per control unit Maximum cable length for movement detector Daylight linking (light sensor LRL 8102) Number of light sensors per control unit Manual Control (on, off and override) Type of ballast
TTX 400
0 2** 125 m
HFD**** 64 7 wire
HFR 60 7 wire
minimum dim level of the ballast 2 presence detectors or 3 with LED disabled any number of luminaires allowed by the TTX400 light line system HFD = HFR-DALI
LRM 8117/00 High bay passive infrared movement detector. Mounting height up to 15 m.
LINESENSE consists of a 618 mm piece of trunking, which is fully pre-equipped and wired to be added to the trunking.The control function is integrated into this extra unit, and can easily be clicked between the light line and the electrical connection unit. High bay movement detectors are connected with standard RJ-12 cables and mounted at the right location with the use of dedicated brackets. LINESENSE is equipped as standard with a telejack splitter to easily connect the detectors to the light line. Installation: clicks only 1 ZTX400 MDU control unit clicks onto the trunking. 2 Movement detector clicks on the bracket. 3 ZTX400 MB-MDU Bracket clicks on the trunking. 4 Telejack cables click the detector and control unit together. 5 ZTX400 CU mains connection clicks on the control unit.
23
Emergency lighting
Non-centralized emergency lighting (EL) in the TTX400 is performed via electrical units equipped with batteries and invertors. Depending on the invertor, a 3 hour or 1 hour emergency lighting solution is provided. Fully pre-equipped EL electrical units save installation time. In line with the TTX400 philosophy, the EL solutions are also clicks only. Decentral emergency lighting with non dimming gear
Electrical unit selection using 7 wires and EL
family code TMX400 lamp 1xTL5-35W 2xTL5-35W 1xTL5-49W 2xTL5-49W 1xTL5-54W 2xTL5-54W 1xTL5-80W 2xTL5-80W 1xTL-D58W 2xTL-D58W 1xTL-D36W 2xTL-D36W gear I IC HFB HFP EL EL1 EL3
TTX400 solutions without dimming can be equipped with EL using standard TTX400 trunking with 7 wires.The poles NN and LL are used to connect the EL. 1 or 3 hour EL solutions can be chosen.
TTX400 solutions with dimming (HFR) can be equipped with EL using TTX400 trunking with 9 wires.The poles NN and LL from the standard flat ribbon cable are used to connect the EL. The additional 8th and 9th hard-core wires are pre-mounted in the TTX400 and used to provide the (0-10V) dimming circuit. The dimming gear is equipped with dedicated wiring with a connector to click into the T splitter in the trunking.
Dimming and emergency lighting: 3 phases and EL via standard connector.The 0-10V line of the HFR gear to the through-wiring in the trunking is via extra connector.
Detail: Connectors to connect 0-10V line of the HFR gear to the throughwiring in the trunking.
24
Accessories
A range of accessories is available for TL-D and TL5 solutions.
ZTX400 UCD Bracket to be used in combination with cable ducts. Suspension via threaded rods up to M13.
ZTX400 CCD Bracket to be used in combination with cable ducts. Suspension via chains or steel cables.
ZTX400 SMS Suspension bracket to be used in combination with M1.5 steel cable.Tool-less mounting, tool-less adjustment of mounting height.
ZTX400 CH Adjustable suspension hook, to be used in combination with ZTX400 UB, UCD or CDB.
ZTX400 CDB Suspension bracket to be used for TTX400 using TTX410 as a cable duct.
ZTX400 BR6 Universal bracket to mount luminaires onto the TTX410. M6 suitable.
ZTX400 LB-FR Bracket to mount 1 lamp TCW215/216 and TCW596 onto TTX410.
ZTX400 WB-FR Bracket to mount surface-mounted luminaires or 2 lamps TCW215/216 on to the TTX410.
ZTX400 EC Electrical connector to connect non TTX400 luminaires onto pre-wired TTX400, including strain relief.
ZTX400 CD582 Cable duct on top of TTX400, to be closed with ZTX400 BC. In combination with ZTX400 CCD.
ZTX410 ICC Internal cable clip to fix cables inside the unwired TTX410.
ZTX400 IP 40 Plastic rings to add on the lamp holders to upgrade the system to IP 40.
accessories solutions
25
Ordering tables
Ordering table TTX400 TL-D
Length* Electrical units** Suspension parts 581 [m] 1.67 3.20 4.73 6.26 7.78 9.31 10.84 12.37 13.90 15.43 16.96 18.49 20.01 21.54 23.07 24.60 26.13 27.66 29.19 30.71 32.24 33.77 35.30 36.83 38.36 39.89 41.42 42.94 44.47 46.00 TMX400 TL-D 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ZTX400 .. 2 2 2 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Trunking 582 TTX400 1 1 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 1 2 3 2 3 4 3 4 5 4 5 6 5 6 7 6 7 8 7 8 9 8 9 10 583 Trunking accessories Mains connection unit ZTX400 CU*** 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 End piece ZTX400 EP-PHL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Reflectors** Aluminium**** or white GMX4.. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Accessories white reflectors** Reflector Reflector end plates coupling piece ZTX400 EP-4.0 ZTX400 CP-4.0 2 0 2 2 2 4 2 6 2 8 2 10 2 12 2 14 2 16 2 18 2 20 2 22 2 24 2 26 2 28 2 30 2 32 2 34 2 36 2 38 2 40 2 42 2 44 2 46 2 48 2 50 2 52 2 54 2 56 2 58 Louvres & optics*****
GGX450 .. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
GGX555 .. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
length including ZTX400 CU ordering table is based on a continuous light line, for maximum number of electrical units per mains connection please check the table on page 27 *** alternative mains connection is possible, see page 15 **** reflector coupling pieces for aluminium reflectors are delivered with the reflectors ***** optional
26
2xTL-D58W 1xTL5-28W 2xTL5-28W 1xTL5-35W 2xTL5-35W 1xTL5-49W 2xTL5-49W 1xTL5-54W 2xTL5-54W 1xTL5-80W
Total 93 123 54 93 66 87 33 60 90 141 90 105 90 108 60 60 141 141 129 96 60 111 60 120 60 60
Note:Technical data, according maximum drop voltage 3%, maximum current 16A and maximum inrush current for circuit breaker B 16A or C 16A.
Ordering numbers
European ordering codes TL5
Description Trunking TL5 TTX400 491 7 TTX400 492 7 TTX400 493 7 TTX400 491 9 TTX400 492 9 TTX400 493 9 TTX400 491 9T TTX400 492 9T TTX400 493 9T TTX400 541 7 TTX400 542 7 TTX400 543 7 TTX400 541 9 TTX400 542 9 TTX400 543 9 TTX400 541 9T TTX400 542 9T TTX400 543 9T TTX400 491 CU7 TTX400 541 CU7 Electrical units TL5 TMX400 1xTL5-49W HFP TMX400 2xTL5-49W HFP TMX400 2xTL5-49W HFP M-S SET TMX400 1xTL5-49W HFR TMX400 2xTL5-49W HFR TMX400 1xTL5-49W HFR 9 TMX400 2xTL5-49W HFR 9 TMX400 1xTL5-49W HFD TMX400 1xTL5-54W HFP TMX400 2xTL5-54W HFP TMX400 1xTL5-54W HFR TMX400 2xTL5-54W HFR TMX400 1xTL5-54W HFR 9 TMX400 2xTL5-54W HFR 9 TMX400 1xTL5-80W HFP TMX400 2xTL5-80W HFP TMX400 1xTL5-80W HFR EOC 29027099 29029499 29031799 68500799 68498799 68502199 68386799 68388199 68390499 30502899 30504299 30506699 68506999 68504599 68508399 68392899 68394299 68396699 68518299 68512099 Description Electrical units TL5 with EL TMX400 1xTL5-49W HFP EL3 TMX400 2xTL5-49W HFP EL3 TMX400 1xTL5-49W HFR 9 EL3 TMX400 2xTL5-49W HFR 9 EL3 TMX400 2xTL5-80W HFP EL3 White reflectors TL5 GMX555 49 MB GMX555 49 WB GMX555 54 MB GMX555 54 WB EOC 29117899 29119299 68418599 68420899 68526799 Description Aluminium reflectors TL5 GMX565 49 HB-NB GMX565 49 M-NB GMX566 49 HB-A GMX566 2 49 HB-WB GMX567 49 M-A GMX570 49 C-NB GMX570 49 HB-NB GMX565 54 HB-NB GMX565 54 M-NB GMX566 2 54 HB-WB GMX567 54 M-A GMX570 54 C-NB GMX570 54 HB-NB LINESENSE ZTX400 MB-MDU ZTX400 MDU-D ZTX400 MDU-P ZTX400 MDU-R LRM 8117/00 EOC 30546299 30550999 30518999 10966499 30558599 29004199 30224999 30548699 30552399 30554799 30556199 30562299 30560899
Conventional ballasts
White reflector + Inlay reflector TL5 GMX555 49 MB C-A20 SET 68466600 GMX555 49 MB C-A40 SET 68465900 GMX555 49 MB C-BD20 SET 68463500 GMX555 49 MB C-BD40 SET 68464200 GMX555 54 MB C-A20 SET 68469700 GMX555 54 MB C-A40 SET 68470300 GMX555 54 MB C-BD20 SET 68467300 GMX555 54 MB C-BD40 SET 68468000 Optics TL5 GGX555 49 L GGX555 49 M2 GGX555 49 M6 GGX555 49 C6 GGX555 49 C6T GGX555 49 C-BD/A GGX555 54 L GGX555 54 M2 GGX555 54 M6 GGX555 54 C6 GGX555 54 C6T GGX555 54 C-BD/A
29109399 29111699 68423900 29113099 29115499 68406299 68408699 30331499 30472499 30474899 30480999 30482399 68410999 68412399 10545199 68366999 30564699
68471099 68473499 68481900 68482600 68524300 68461199 68475899 68477299 68479600 68480200 68525000 68459899
27
Trunking TL-D for double switching TTX400 581 2C5 68424699 TTX400 581 2C7 68430799 TTX400 582 2C5 68426099 TTX400 582 2C7 68432199 TTX400 583 2C5 68428499 TTX400 583 2C7 68434599 Empty trunking TTX410 582 TTX410 583 Electrical units TL-D TMX400 1xTL-D58W I TMX400 2xTL-D58W I F32 TMX400 1xTL-D58W IC TMX400 2xTL-D58W IC TMX400 2xTL-D58W IC F32 TMX400 1xTL-D58W HFB TMX400 2xTL-D58W HFB TMX400 2xTL-D58W HFB M-S SET TMX400 2xTL-D58W HFB F32 TMX400 1xTL-D58W HFP TMX400 2xTL-D58W HFP TMX400 2xTL-D58W HFP F32 TMX400 2xTL-D58W HFP M/S
Electrical units TL-D with EL TMX400 1xTL-D58W IC EL3 TMX400 1xTL-D58W IC EL1 TMX400 2xTL-D58W IC EL3 TMX400 2xTL-D58W IC EL1 TMX400 2xTL-D58W IC EL3 F32 TMX400 2xTL-D58W HFB EL3 TMX400 2xTL-D58W HFB EL3 F32 TMX400 1xTL-D58W HFP EL1 TMX400 2xTL-D58W HFP EL1 TMX400 1xTL-D58W HFP EL3 TMX400 2xTL-D58W HFP EL3 TMX400 2xTL-D58W HFP EL3 F32 TMX400 1xTL-D58W HFR EL1 TMX400 1xTL-D58W HFR 9 EL3 TMX400 2xTL-D58W HFR 9 EL3 Electrical units for spots TMX403 58-2 TMX405 58-4 TMX407 49 2C TMX407 58 2C TMX407 58 3C White reflectors TL-D GMX430 58 GMX450 1 58 GMX450 1 58 RP GMX450 1 58 RS GMX450 2 58 GMX450 2 58 RP GMX450 2 58 RS
68558899 68560199 68562599 68564999 68566399 30440399 68362199 29080599 28989299 09575299 09579099 68364599 09627899 68414799 68416199
L LP M2 M5 ML P L LP M2 M5 ML P
09379699 09375899 09383399 09387199 09371099 10156999 09204199 09395699 09401499 09405299 09391899 10160699
09351299 09353699
09249299 68346199 09253999 30823499 68348599 09277599 09281299 68422200 68354699 09269099 09273799 68356099 09862300
Aluminium reflectors TL-D GMX460 1 58 C-NB GMX465 1 58 HB-NB GMX465 1 58 M-NB GMX465 2 58 HB-NB GMX465 2 58 M-NB GMX466 2 58 HB-WB GMX466 2 58 M-WB GMX467 1 58 M-A GMX470 1 58 C-NB LINESENSE ZTX400 MB-MDU ZTX400 MDU-D ZTX400 MDU-P ZTX400 MDU-R LRM 8117/00
TTX400 order assistent Free program to configurate your TTX400 solution into a complete ordering list. www.TTX400.philips.com
28
Photometrics
Photometrics
1xTL-D58W
87214 73% 22
2xTL-D58W
87258 73% 24
1xTL5-49W
88653 90% 24
1xTL5-49W
88652 85% 23
2xTL5-49W
88662 80% 26
2xTL5-49W
88661 72% 25
White reflector
50 100
100 200
100 200
100 200
150 200 250 300 300 400 500 300 400 500
300 400
50 100
100 200
150 300
100 200
600 750
Aluminium reflector
50 100
200 400
GMX466 M-WB
GMX570 HB-NB
GMX566 HB-WB
GMX467 M-A
750
GMX567 M-A
GMX566 HB-A
Legend
87214 73%
120o 180o
22
120o
90o 50 60
o
90o
60
30
300 (cd/1000lm) 0
o
30
29
www.TTX400.philips.com