Network Recording Instrument For LAN: Memory Hicorder
Network Recording Instrument For LAN: Memory Hicorder
Network Recording Instrument For LAN: Memory Hicorder
- Features q 10.4 inch color TFT display The large, bright display shows waveforms for all channels (32 analog + 32 logic channels) in 12 colors, allowing easy visual identification. The display also greatly facilitates operation of the unit. q Simultaneous measurement in up to 32 analog channels Featuring the highest number of input channels in this class, the 8826 lets you simultaneously record in 32 analog + 32 logic channels. All analog inputs are isolated. q Built-in MO drive (factory option) The internal MO (magneto-optical) disk drive can store up to 640 megabytes on a single disk. A floppy disk drive and type III PC card slot are provided as standard equipment. This makes it easy to archive measurement data. Besides its internal binary file format, the 8826 can also store data as ASCII files and display screen shots as BMP files. q Large-capacity memory In the standard memory configuration, the 8826 can store a total of 16 mega-words. With expansion memory installed, capacity is a full 64 mega-words. This provides for up to 2 mega-words per channel when 32 channels are used. Even with high-speed sampling, long-term recording is possible. q CE Mark compliant Complies with the EC directive determining safety standards in Europe (within the EU). q Internal sampling rate of 1 MS/s, 500 kS/s external sampling rate The A/D converter that digitizes measurement signals operates at the high sampling rate of 1 M sample/s (1 sec cycle). Resolution for the voltage axis is 12 bits. Sampling is carried out for all channels simultaneously. q Converts to text file used with a Wave viewer
(supplied accessories, PC application software)
To open measurement data in PC applications such as Excel, the data must be converted to text data in the CSV format. The PC application software which comes standard in the package enables easy operation. q Connects to PCs and printers on a LAN network Its use with PCs can be selected according to the usage. It allows remote operation and data transfer via LAN connection, GP-IB connection, or RS-232C connection. External MO drive connected via an external SCSI interface is also possible. q On-screen help Explanation of button operations and many basic operations can be displayed on the screen with the provided online help function. q Plug-in slots enhance versatility The number of measurement channels can be matched to the application requirements by using plug-in modules. New types of converter amplifiers and other accessories to be introduced in the future will allow direct measurement of various physical quantities.
Plant maintenance
In plants, memory recorders are used to measure and record the operation of solenoid and control valves. Since the 8826 MEMORY HiCORDER can simultaneously create X-Y plots, the relationship between flow and valve lift can also be observed.
CH 32
Insulation
Input voltage
Output waveform
Time axis 100 s /DIV 200 s /DIV 500 s /DIV 1 ms /DIV 2 5 10 20 50 100 200 500 1 s /DIV 2 5 10 30 1 min /DIV 2 5
32 ch
Sampling period 1 s 2 s 5 s 10 s 20 s 50 s 100 s 200 s 500 s 1 ms 2 ms 5 ms 10 ms 20 ms 50 ms 100 ms 300 ms 0.6 s 1.2 s 3.0 s
4s 8s 20s 40s 1m 20s 3m 20s 6m 40s 13m 20s 33m 20s 1h 6m 40s 2h 13m 20s 5h 33m 20s 11h 6m 40s 22h 13m 20s 2days 7h 33m 20s 4days 15h 6m 40s 13days 21h 20m 27days 18h 40m 55days 13h 20m 138days 21h 20m
0.5s 1s 2.5s 5s 10s 25s 50s 1m 40s 4m 10s 8m 20s 16m 40s 41m 40s 1h 23m 20s 2h 46m 40s 6h 56m 40s 13h 53m 20s 1day 17h 40m 3days 11h 20m 6days 22h 40m 17days 8h 40m
s Zoom function
To make the most of the large-capacity memory, it is possible to display a compressed waveform simultaneously with a magnified waveform. Since the 8826 is capable of storing a large amount of data, high-speed sampling is also possible for waveforms with a long duration. Accordingly, while observing the compressed image of the entire waveform, it is also possible to observe the magnified details of desired parts. Compressed display of a part of the entire waveform is also possible.
The sampling rate for the memory recorder can be controlled by the timing of an external clock signal. This is useful for example to collect data synchronized to the running cycle of an engine. s
Input waveform
Using two cursors on the display screen, it is possible to read out time differences or voltage differences.
Input voltage
- Function Details -
Real time save function *supported in version 2.20 or later, 9598 required
The real time save function enables data to be saved to the internal MO while waveform is being measured. The compressed waveform is displayed on the screen at real time. This function is valid at the recorder and memory function. Write to the internal MO can be up to 1kS/s (= 100ms/DIV) for 16 channels, or up to 500S/s (200ms/DIV) for 32 channels. With the real time save function, data measured at the pre-determined sampling below the maximum sampling can be saved to the MO at any time. In addition, since the same data is compressed along the time axis and displayed on the screen, you can check how recording is going. Compressed data is saved to the MO for later retrieval.
MEM Time axis 100 ms /DIV 200 ms /DIV 500 ms /DIV 1 s /DIV 2 s /DIV 5 s /DIV 10 s /DIV 30 s /DIV 1 min /DIV 2 min /DIV 5 min /DIV
230MB MO
640MB MO
1h 58m 51s 3h 58m 50s 4h 57m 9h 53m 50s 19h 47m 2days 1h 22m 30s 4days 2h 28m 20s 12days 4h 10m 23days 23h 46days 10h 106days 2h 40m
5h 30m 52s 5h 30m 50s 13h 46m 55s 1day 3h 33m 30s 2days 7h 5m 5days 17h 29m 10s 11days 10h 11m 40s 33days 21h 35m 66days 17h 129days 6h 208days 8h
Input waveform
Display data (REC waveform): compressed waveform is displayed on screen Compressed data is saved temporarily in the internal memory.
However, display time axis of REC data is 2 steps later than that of MEM data. The maximum recording time that can be set is determined by the free capacity of the MO disc, and the time axis and recording length of MEM/REC. Nevertheless, since the maximum recording length of REC is fixed at 1000 DIV, or 5000 DIV if there is memory expansion, even if there is plenty of free capacity on the MO disc, the recording time cannot exceed the value determined by REC time axis multiplied by 1000 DIV.
Trigger functions capable of monitoring all 32 channels For all of the measurement functions, including record and memory recorder, triggers can be set on all 32 channels. In addition to a simple level trigger based on comparison with a single voltage value, the following trigger functions are also available:
Window trigger based on 2 voltage values Voltage drop trigger for AC power lines Level trigger based on rms values Cycle trigger monitoring the rising edge of a voltage Pattern trigger monitoring the Hi/Low condition of a logic signal
EXT trigger Analog CH 1 Logic A Trigger sources Analog CH 32 Logic D AND/OR Timer MANUAL trigger Trigger levels
Window trigger
- Function Details -
Ethernet
Copy or remote operations of HiCORDER data files from client PCs running 9333 (software)
communications, and faulty data is automatically resent. q Installation costs at the PC side are lower than GP-IB.
Disadvantages of Ethernet and TCP/IP Connected Systems
q Transfer time depends on network usage, because the
MO disk (option)
* In addition to HiCORDER's read/write native file (binary format), data can also be saved to text files (CSV format) which can be opened by PC spreadsheet applications, or waveform bitmap files (BMP format). However, because data saved in text files cannot be read by HiCORDER, it is recommended that text data conversion be performed on PCs.
Approx. Display Input Voltage Upper Limit Value Variable Lower Limit Value
Scaling Functions
Actual measurements usually involve parameters other than voltage. Various physical parameters such as speed, vibration and temperature commonly need to be recorded, and this signal data should be directly readable, without having to be manually converted. In such measurement conditions, the scaling function can be used to automatically convert to the desired parameter value. Additionally, waveform amplitude can be adjusted using the Variable Gain function. In addition, if accurate input voltage amplitude measurement is not required, the amplitude can be intentionally modified with the Vernier Adjustment function.
Scaling
Variable OFF
Variable ON
Shrink Vernier
Expand
- Function Details -
Time domain
Frequency domain
Recording paper
*1 When the memory expansion is installed, the maximum recording length for reprinting is prolonged. In the standard configuration, recording length is 2000 divisions. With memory expansion, it is 10000 divisions.
Simultaneous execution of up to 16 mathematical functions * In memory recorder function Available waveform processing functions include all arithmetic operations as well as differentiation, integration, and other functions whose results can be displayed as waveforms. Up to 16 functions can be set. Waveform parameter processing * In memory recorder function
13 types of parameters such as maximum value and minimum value can be selected for processing. For simultaneous operation in all 32 analog channels, up to 4 parameters are possible.
1 M sample/s (1 s period)
* Simultaneous sampling for 32 analog + 32 logic channels
12 bits 4 mega-words/channel (4 channels used) to 12 bits 500 kilo-words/channel (32 channels used)
* Memory capacity can be expanded 4 times. Floppy disk drive 1: 1.44 M/1.2 M/720 KB, MS-DOS format Type III PC card slot 1: For SRAM cards up to 32 MB, flash ATA or hard disk cards up to 528 MB. Magneto-optical drive (option) 1: 640/ 540/ 230/ 128 MB/ over write media support File format : Binary, text, BMP
Can record data from before the trigger point, 0 to 100% or -95% of recording length; 15 settings
Other functions
File storage
Waveform processing, waveform parameter processing, waveform averaging, memory segmentation (max. 255 segments), logging (numerical printout), X-Y waveform plot, voltage axis zoom 2 to 10; 3 settings, compression 1/2, zoom, variable display, graph superimposition
Recorder Function
Time axis Sampling period Recording length X-Y sampling period X-Y axis resolution 20 ms to 1 hour/ division: 16 settings, 1 division = 100 samples, time axis compression 1/2 to 1/500: 8 settings
* 20 ms to 200 ms/ division ranges shown on display. Printout speed is 20 mm/ s.
Clock and settings, battery life approx. 10 years (at 25C/ 77F) Terminal block: trigger input/ output, external start/ stop, print input, waveform judgment output, external sampling input. SCSI: for MO drive connection
* Please contact HIOKI for information on compatible MO drives.
1 s to 100 ms: 6 settings (selectable from 1/100 or less of time axis) Settable in 1-division steps, 25 to 2000 divisions*1, "continuous"*2, only continuous for X-Y plotting
*1 With memory expansion: max. 10000 divisions *2 When time 10 ms to 200 ms/ division and printer is ON, continuous is not available.
500 s; fixed (dot), 500 s to 18 ms (line) 20 dots/ division (display), 80 dots (horizontal) 80 dots (vertical)/ division (printer) Reprinting of stored data (last 2000 divisions), logging (numerical printout), virtual recording (data are written to internal memory without the use of printer paper), additional recording (recording is resumed without overwriting previous data), voltage axis magnification 2 to 10; 3 settings, compression 1/2; 1 setting, variable display.
Operation: +5C/ 41F to +40C/ 104F, 35% to 80% rh Storage: -10C/ 14F to +50C/ 122F, 20% to 90% rh 100 to 240 V AC (50/ 60 Hz) Other functions
Power requirements
Power consumption
(with 8936 full loaded)
300 VA max. (at 100 V AC) (approx. 100 VA with printer OFF)
Approx. 401 (15.79) W 235 (9.25) H 382 (15.04) D mm (inch) approx. 11 kg/ 388.0 oz (main unit only) Power cord (1), printer paper (1), protective cover (1), roll paper attachment (2), PC card protector (1), Wave viewer software (1)
RMS calculation accuracy 3 % f.s. Recording length Settable in 1-division steps, 25 to 2000*1 divisions, continuous
*1 With memory expansion: max. 10000 divisions
Other functions
Reprinting of stored data (last 2000 divisions), logging (numerical printout), additional recording (recording is resumed without overwriting previous data), voltage axis magnification 2 to 10; 3 settings, compression 1/2; 1 setting, variable display.
Auxiliary Functions
General Printing of settings including input range, trigger time, etc, cursor measurement, scaling, comment input, screen hard copy, start condition retention, auto setup, auto saving, remote control, auto ranging, view function, online help, key lock, list printing, level monitor function. Scaling: Translation of amplitude gradation only Variable: Arbitrary setting of the upper and lower limit of the waveform display range Allows precision adjustment of input voltage. Type: Area judgment using reference waveform for time axis waveform, X-Y plot, or FFT display. Parameter judgment for waveform parameter processing. Judgment output: pass/fail output, open-collector 5 V voltage output Average value, effective (rms) value, peak to peak value, maximum value, time to maximum value, minimum value, time to minimum value, period, frequency, rise time, fall time, area value, X-Y area value, and standard deviation.
(Maximum possible calculation up to 1000 DIV, with memory expansion max. 5000 divisions; accuracy is within the tolerance of the input module, 16 simultaneous operations)
Max. 25 mm/ s (0.98 inch/ s) 10.4 inch TFT color LCD, with English/ Japanese selector
* 640 480 dots
Trigger Function
Trigger source CH1 to CH32 (analog), CHA to CHH (logic), external, timer, manual (either ON or OFF for each source), logical AND/ OR of sources Level: Digital setting of voltage. Triggered when set value is exceeded in UP or DOWN direction. Window: When entering or exiting a level range defined by upper or lower limit Voltage drop: Only for AC power lines. Triggered when the peak voltage falls below setting value RMS level: Only for DC and AC power lines. Triggered when rms value crosses set value in UP or DOWN direction Period: When rising or falling edge of set voltage does not fall within cycle range
Level setting resolution Equivalent to 0.25 % when full scale is set to 20 divisions Trigger types (Logic) Pattern trigger: 1, 0, or (disregard), logical product (AND) or logical sum (OR) set for 4 channels
Waveform processing Four arithmetic operations, absolute value, exponentiation, calculations common logarithm, square root, moving average, (Memory recorder) differentiation once and twice, integration once and twice, parallel displacement along the time axis
CE mark compliance
Applicable standards Safety: EN61010 EMC: EN55011, EN50082
9
Thermal printer (264 mm width monochrome recording paper) logic probe connection Operation buttons Input module slots (for 16 modules) Top side
Floppy disk drive Waveform monitor (10.4" color TFT LCD) MO drive (option)
SCSI interface
8936 ANALOG UNIT (accuracy at 23 5C/ 73 9F after 30 min of warm-up time; accuracy guaranteed for 1 year)
Number of channels: 2, Connector: Insulated BNC
* Input isolated from output, inter-channel isolation
5 mV to 20 V/ division, 12 ranges, full-scale (f.s.) = 20/ 24 divisions, AC voltage for possible measurement/ display using the memory function : 335 V rms, Low-pass filter, 5/ 500/ 5 k/ 100 kHz, the measurement resolution is 1/80 of range * When used with 8826 1 MS/s (simultaneous sampling of two channels) DC amplitude: 0.4 %f.s. Zero-position: 0.1 %f.s. -50 % to 150 %, 1 % step
* With zero-adjustment function
100 s to 5 minutes/ division; 20 settings, 1 division = 100 samples, time axis zoom 2 to 10; 3 settings, compression 1/2 to 1/10000, 12 settings
* Sampling period 1/100 or less of time axis range (min. 1 s)
*1 With memory
Memory recorder: 25 to 2000* divisions * With memory expansion max. 10000 divisions (Arbitrary setting in 1-division steps also possible.) Recorder: timer trigger, OFF Memory recorder: CH1 to CH32 (analog), logic A to H, external trigger Only recorder waveform is output when printer output is started, reprinting of stored recorder waveform data (last 1000* divisions)
Frequency characteristics DC to 400 kHz 3 dB, with AC coupling: 7 Hz to 400 kHz 3 dB 1 M, 30 pF approx. (at C 100 kHz) DC, GND, AC 400 V DC (upper voltage which when applied to between input pins does not damage them) 370 V AC, DC (upper voltage which when applied to input channel casing or between input channels does not damage them) None
* The input cord is optional
Trigger source
Input coupling Max. allowable input Max. rated voltage to earth Accessories
Other functions
Additional recording function (recording is resumed without overwriting previous data), variable display
8938 FFT ANALOG UNIT (accuracy at 23 5C/73 9F, 30 minutes after power-on; accuracy guaranteed for 1 year)
Anti-aliasing filter Other functions Accessories Cutoff frequency 20, 40, 80, 200, 400, 800, 2k, 4k, 8k, 20k, 40 kHz auto-select (linked to frequency range) Same as the 8936 ANALOG UNIT None
*Input cord is optional
Memory recorder: depending on free capacity of MO disk Switching of recorder/ memory recorder, and fixing recorder waveform during measurement Timer trigger For MEM waveform, the last 2000 DIV portion (or 10000 DIV if there is memory expansion) of data is saved to the semiconductor memory of the main unit, enabling reversed scroll monitoring and re-printing. MO disk, drived by 9598 MO UNIT (factory option) 640 MB, 540 MB, 230 MB, 128 MB MEM waveform data (Real-time save data), REC waveform data (Compressed data), Index file
Approx. 170 (6.69) W 20 (0.79) H 148 (5.83) D mm (inch), approx. 300 g (10.6 oz)
8937
8937 VOLTAGE/TEMPERATURE UNIT (accuracy at 23 5C/ 73 9F, 60 minutes after power-on; accuracy guaranteed for 1 year)
Number of channels: 2 each for voltage and temperature
Inputs
500 V to 2 V/ division; 12 settings, full-scale (f.s.) = 20/ 24 Voltage measurement divisions, low-pass filter: 5/ 500/ 5 k/ 100 kHz, the measurement range resolution is 1/80 of range * When used with 8826 Temperature measurement range 10 C to 100 C/ division; 4 settings, full-scale (f.s.) = 20/ 24 divisions, low-pass filter: 5/ 500 Hz, measurement resolution: 1/80 of range * When used with 8826 K: -200 to 1350 C, E: -200 to 800 C, J: -200 to 1100 C, T: -200 to 400 C, N: -200 to 1300 C, R: 0 to 1700 C, S: 0 to 1700 C, B: 300 to 1800 C, Reference junction compensation: internal/ external (switchable) Voltage input: 1 MS/s, Temperature measurement: 4 kS/s
(2-channel simultaneous sampling)
Thermocouple range
Accuracy
Voltage input: DC amplitude 0.4% of f.s. Zero-position 0.15% of f.s. Temperature measurement (K, E, J, T, N): 0.1% of f.s. 1C, 0.1% of f.s. 2C (-200 to 0C), (R, S): 0.1% of f.s. 3C, (B): 0.1% of f.s. 4C (400 to 1800C) Reference junction compensation accuracy: 0.1 % f.s. 1.5 C (internal compensation) Voltage input: -50 % to 150 %, 1 % steps * With zero-adjust function Temperature measurement: -100 % to 100 %, 1 % steps
Wave viewer (Wv) software (Supplied accessories, added from Aug. 2000)
Simple display of waveform files, Converts binary files to text files; CSV/space/tab pause selectable, a selection can be specified and thinning enabled. Display format settings: scroll function, enlarge/reduce display, display CH settings Trace the voltage value, jumpe to the point of cursor/trigger, etc., Windows 95/98/Me, Windows NT 4.0 (OSR3 or later)/2000
Zero position
Functions
Voltage input: DC to 400 kHz + 1/-3 dB Frequency characteristics Temperature measurement: DC to 1 kHz + 1/-3 dB Input resistance and capacitance Input coupling Max. allowable input Max. rated voltage to earth Accessories Voltage input: 1 M, 50 pF approx. (at C 100 kHz) Temperature measurement: 5.1 M DC, GND, AC 30 V rms or 60 V DC
(upper voltage which when applied to between input pins does not damage them)
Operating environment
30 V rms or 60 V DC None
(upper voltage which when applied to input channel casing or between input channels does not damage them) * The input cord is optional
10
Approx. 170 (6.69) W 20 (0.79) H 148 (5.83) D mm (inch), approx. 250 g (8.8 oz)
8939
8939 STRAIN UNIT (accuracy at 235C/ 739F, 60 minutes after power-on; accuracy guaranteed for 1 year)
Inputs Converter connector Suitable converter Measurement range Maximum sampling rate Accuracy (after auto-balancing) Balancing Zero position Number of channels: 2, Connector: Adapter cable connector
* Input isolated from output, inter-channel isolation
Via adapter cable, TAJIMI PRC03-32A10-7F10.5 Strain gage converter, bridge impedance: 120 to 1 k, gage factor 2.00, bridge voltage 2 0.05 V 20 to 1000 / division; 6 settings, full-scale (f.s.) = 20/ 24 divisions, low-pass filter: 10 Hz, 30 Hz, 300 Hz, 3 kHz, OFF the measurement resolution is 1/80 of range * Using 8826 1 MS/s (simultaneous sampling for 2 channels) DC amplitude: (0.5 %f.s. +2 ) Zero-position: 0.5 %f.s. Electronic auto-balancing, max. adjustment range 10000 -50 % to 150 %; in 1% steps
* With auto-balancing
Frequency characteristics DC to 20 kHz +1/-3 dB 10 V (DC + AC peak) Max. allowable input (upper voltage which when applied to between input pins does not damage them) Max. rated voltage to earth Accessories
9318
(upper voltage which when applied to input channel casing or between input channels does not damage them)
Approx. 170 (6.69) W 20 (0.79) H 148 (5.83) D mm (inch), approx. 310 g (10.9 oz)
8947
9319
8947 CHARGE UNIT (accuracy at 23 5C/ 73 9F after 60 min of warm-up time; accuracy guaranteed for 1 year)
Number of channels: 2
8940
Approx. 170 (6.69) W 20 (0.79) H 148 (5.83) D mm (inch), approx. 300 g (10.6 oz)
Input
Measurement objects can be selected individually for each channel. Full isolation between inputs, and between inputs and recorder. Common GND for voltage input and charge input channels.
8940 F/V UNIT (accuracy at 23 5C/ 73 9F after 30 min of warm-up time; accuracy guaranteed for 1 year)
Input Sensor connector terminal
Compatible current sensors
Charge input: miniature connector (#10-32 UNF) Suitable converters Charge input: piezoelectric charge output acceleration pickup sensors, Internal pre-amplifier input: acceleration pickup sensors with built-in pre-amplifier
50 m (m/s2)/DIV to 10 k (m/s2)/DIV, 12 ranges 6 types, the measurement resolution is 1/80 to 1/32 of range (changes according to measurement sensitivity) Measurement sensitivity: 0.1 to 10 pC/ (m/s2), Pre-amplifier internal input measurement sensitivity: 0.1 to 10 mV/ (m/s2), Amplitude accuracy: 2 % f.s., Frequency characteristics: 1 to 50 kHz +1/ -3 dB, Low-pass filter: 500 / 5 kHz, Pre-amplifier driving power supply: 2 mA 20%, +15 V 5%, Highest input charge : 500 pC (high sensitivity side 6 ranges), 50000 pC (low sensitivity side 6 ranges)
9270, 9271, 9272, 9277, 9278, 9279, 3273 Frequency: 0.05 Hz to 5 kHz/ division, 11 ranges, 5 (r/min) to 500 (r/min)/ division, 5 ranges, P50 Hz (40 to 60 Hz), P60 Hz (50 to 70 Hz) Integration: 5 counts to 500 k counts/ division, Pulse duty ratio: 100 % f.s. Current: 5 mA to 100 A/ division, 10 ranges, linked to use with type of the clamp-on sensor, Voltage: 0.5 mV to 2 V/ division, 12 ranges, Max. allowable input: 30 V rms or 60 V DC, full-scale (f.s.) = 20/ 24 divisions, low-pass filter, 5/ 500/ 5 k/ 100 kHz or OFF, the measurement resolution is 1/80*3 of range * When used with 8826, and when used with 9279 CLAMP ON SENSOR, the resolution
3
Measurement ranges
Charge input (miniature connector) Pre-amplifier internal input (BNC terminal)
Measurement range
is 1/64 of range
500 V to 2 V/DIV, 12 ranges, the measurement resolution is 1/80 to 1/32 of range (changes according to measurement sensitivity) DC amplitude accuracy: 0.4 % f.s., Frequency characteristics: DC to Voltage input (BNC terminal) 400 kHz +1/ -3 dB, Low-pass filter: 5/ 500/ 5 k/ 100 kHz, Input coupling: DC, AC, GND, Max. allowable input: 30 V rms or 60 V DC
Measurement ranges
Max. sampling period Other functions Max. rated voltage to earth Accessories
1 s (voltage, current, integration), 1.125 s (frequency, pulse duty ratio) Voltage input pull-up: ON (10 k)/ OFF Input coupling: DC, GND, AC (voltage, current), DC (others) 30 V rms or 60 V DC None
(upper voltage which when applied to input channel casing or between input channels does not damage them) * The input cord and conversion cable are optional
9321
Response time : 500 ns maximum Dimensions and mass: Approx. 62 (2.44) W 94 (3.7) H 20 (0.78) D mm (inch), 150 g (5.3 oz) Max. allowable input: 0 to +50 V DC
9320
Max. allowable input: 250 V rms (HIGH range), 150 V rms (LOW range) Dimensions and mass: Approx. 62 (2.44) W 127 (5) H 20 (0.78) D mm (inch), 320 g (1.13 oz)
Functions: s Display functions: Waveform display/X-Y display/digital value display/cursor function/scroll function/maximum number of channels (32 channels analog, 32 channels logic)/gauge display (time, voltage axes)/graphical display s File loading: Readable data formats (.MEM, .REC, .RMS)/Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration) s Data conversion: Conversion to DSV format, tab delimited, space delimited/data culling (simple)/convert for specified channel/batch conversion of multiple files s Print functions: Print formatting (1 up, 2-to-16 up, 2-to-16 rows, X-Y 1-to-4 up/preview/hard copy/functions usable on any printer supported by operating system s Other: Parameter calculation/search/clipboard copy/launching of other applications
11
Note: Product names appearing herein are trademarks or registered trademarks of various companies.
Instrument
Input Modules
9599 MEMORY BOARD (48 mega-words) Expands instrument memory by 4 user installable. 9320 LOGIC PROBE 4-channels, on/off detection of voltage/contact signal 9598 MO UNIT
Installs on the bottom of the FDD unit. Must specify when ordering: not user installable.
8936 ANALOG UNIT 8937 VOLTAGE/TEMPERATURE UNIT 8938 FFT ANALOG UNIT 8939 STRAIN UNIT 8940 F/V UNIT (8826 Ver. 2.10 or later can be used),
(Current probes with a serial number of No. 1999-0338386 or later can be used, older types cannot be used.)
Storage Media
9626 PC CARD 32M
(PCMCIA adapter, 32 MB)
8946 4ch ANALOG UNIT (it cannot be used with 8826) 8947 CHARGE UNIT (8826 Ver. 2.20 or later can be used)
High-voltage input
Important Notice !
Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
Recording paper
9229 RECORDING PAPER roll type thermal paper, 30m/ 98.43 feet, 6 rolls / 1 set 9229-01 RECORDING PAPER perforated, roll type thermal paper, 30 m/ 98.43 feet, 6 rolls / 1 set
PC communication
(compliance with the PCMCIA (compliance with the PCMCIA (compliance with the PCMCIA (compliance with the PCMCIA Standard) Standard) * With a GP-IB cable, Standard) * With a printer cable, Standard) Manufactured by third parties. cord length : 2m (6.6 feet) cord length : 1.5m (4.9 feet)
9555 9279
9555
9272
*9303 PT
9277 9278 Insulation transformer, 400 V or 200 V AC input, 10 V AC output, for AC power line measurement.
Enables observation of distorted AC current waveforms. Input: up to 200 A, 5 to 50 kHz for 2 VAC out
Observe waveforms from DC to distorted AC. 3273 CLAMP ON PROBE Wide (DC to 50 MHz) range, mA-level to 15 A rms current. Requires power from 3272 or 8940 F/V UNIT with the 9319 ADAPTER CABLE.
Input up to 500 A, DC to 20 kHz for 2 VAC out Note : Can only be used in combination with the 9555 SENSOR UNIT or 8940 F/V UNIT.
Ordering information
8826 MEMORY HiCORDER
8826
Example of combination
The 8826 MEMORY HiCORDER cannot operate alone. To use the 8826, mount one or more optional input modules on it. An input cord for measurement use is not provided with the input module. Please purchase the optional 9197 or 9198 CONNECTION CORD together with the input module. 7 unit of 8936 (14ch) 9 unit of 8936 (18ch) 11 unit of 8936 (22ch) 13 unit of 8936 (26ch) 15 unit of 8936 (30ch)
8826
Example of combination
8 unit of 8936 (16ch) 10 unit of 8936 (20ch) 12 unit of 8936 (24ch) 14 unit of 8936 (28ch) 16 unit of 8936 (32ch)
DISTRIBUTED BY
HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com
Shanghai Representative Office : 1704 Shanghai Times Square Office 93 Huaihai Zhong Road Shanghai, 200021, P.R.China TEL +86-21-6391-0090, 0092 FAX +86-21-6391-0360 E-mail: [email protected]
All information correct as of Aug. 5, 2003. All specifications are subject to change without notice.
8826E5-38B-03P