0% found this document useful (0 votes)
211 views8 pages

ASMi 54C

The document describes an 8-port SHDSL/SHDSL.bis module that provides Ethernet and TDM services over copper lines. It can deliver digital data to customer premises over existing copper cables at data rates up to 22.8 Mbps. The module has Ethernet and E1 ports and supports services like Ethernet, E1, and remote power feeding over SHDSL/SHDSL.bis copper lines.

Uploaded by

s_meher
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
211 views8 pages

ASMi 54C

The document describes an 8-port SHDSL/SHDSL.bis module that provides Ethernet and TDM services over copper lines. It can deliver digital data to customer premises over existing copper cables at data rates up to 22.8 Mbps. The module has Ethernet and E1 ports and supports services like Ethernet, E1, and remote power feeding over SHDSL/SHDSL.bis copper lines.

Uploaded by

s_meher
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Data Sheet

Megaplex-4100 Modules

ASMi-54C
Ethernet and TDM over SHDSL/SHDSL.bis 8-Port Modules

Ethernet and E1 extension over long distance SHDSL.bis copper lines

16 wire-modules for Ethernet and TDM services over 2W (1-pair), 4W (2-pair), or 8W (4-pair) SHDSL/SHDSL.bis lines Data rates of up to 5.7 Mbps for 2W, up to 11.4 Mbps for 4W and up to 22.8 Mbps for 8W Operation with RADs ASMi-52/ASMi-52L (SHDSL) and ASMi-54/ASMi-54L (SHDSL.bis) Two Ethernet ports (copper/fiber) with 8-port interface for local E1 termination; integral L2 Ethernet switch with full VLAN support Range of up to 6.6 km (4.1 miles) over 26 AWG 2-wire cable EFM (Ethernet First Mile) or M-pair bonding over SHDSL/SHDSL.bis

The Access Company

ASMi-54C Ethernet and TDM over SHDSL/SHDSL.bis 8-Port Modules

ASMi-54C is a family of SHDSL/SHDSL.bis Ethernet and TDM modules for the Megaplex-4100 chassis that deliver digital data to customer premises over existing copper cables of the distribution network, while eliminating the need for repeaters. ASMi-54C modules provide a simple, low-cost connectivity solution using High speed Digital Subscriber Line (SHDSL/SHDSL.bis) technology, as standardized by ITU-T Rec. G.991.2.

The ASMi-54C family includes three main module types: ASMi-54C/ETH Ethernet over SHDSL.bis 8-port module with EFM support ASMi-54C/E1/N - E1 over SHDSL/SHDSL.bis 8-Port module ASMi-54C/E1/ETH/N E1 and Ethernet over SHDSL/SHDSL.bis 8-port module (with optional remote power feeding support).

ASMi-54C/ETH transports Ethernet over 1, 2, and 4 pairs of SHDSL.bis copper lines. It can operate as a Central SHDSL.bis (STU-C) or Remote (STU-R) SHDSL.bis Termination Unit working with up to 8 ASMi-54/ASMi-54L standalone devices or another ASMi-54C module.

Figure 1. TDM/Ethernet Services over Copper and Fiber Infrastructure

Data Sheet

The ASMi-54C/E1/N module (available starting from version 3.0) forwards transparently E1 data over 1 or 2 pairs of SHDSL.bis/SHDSL copper lines to ASMi-54/ASMi-54L (SHDSL.bis) or ASMi-52/ASMi-52L (SHDSL) standalone modems on the remote site. These modules operate as Central SHDSL/SHDSL.bis (STU-C) Terminal Units for up to 8 standalone modems. The ASMi-54C/E1/ETH/N multiplexer module (available starting from version 3.0) forwards transparently E1 and Ethernet data over 1 or 2 pairs of SHDSL.bis/SHDSL copper lines to ASMi-54/ASMi-54L (SHDSL.bis) or ASMi-52/ASMi-52L (SHDSL) standalone modems on the remote site. These modules operate as Central SHDSL/SHDSL.bis (STU-C) Terminal Units for up to 8 standalone modems.
Note: ASMi-54C/E1/N and ASMi-54C/E1/ETH/N modules cannot work with a mix of ASMi-54/54L and ASMi-52/52L modems at the far end.

The ASMi-54C/E1/ETH/N module has a special remote power feeding variant that delivers power and data over 2 or 4 wires to up to 4 SHDSL/SHDSL.bis remote modems or repeaters and eliminates the need for locally powered modems or repeaters. Each SHDSL/SHDSL.bis port is a multirate SHDSL/SHDSL.bis modem transmitting user-selectable data rates of up to 5.7 Mbps on each pair. Using TC-PAM 16/32 line coding SHDSL/SHDSL.bis technology, the modems operate in full-duplex mode at the data rate of up to 5.7 Mbps per port. The following types of interfaces are available: Eight SHDSL.bis independently configurable external ports (all models). /N models support also SHDSL ports Two 10/100 Mbps Ethernet ports for Ethernet services (all models besides ASMi-54C/E1/N). Eight independently configurable E1 ports for E1 services (/N models)

Table 1 summarizes the number of remote CPE units that can be managed by ASMi-54C/ETH modules and ASMi-54C/N modules (either ETH+E1 or E1 only).
Table 1. Number of Managed Remote CPEs ASMi-54C/ETH Line Type 2W 4W 8W Remote units 8 4 2 ASMi-54C/N Line Type 2W 4W 8W Remote units 8 4

Figure 2. Carrier Service Extension for Business Customers

ASMi-54C Ethernet and TDM over SHDSL/SHDSL.bis 8-Port Modules

ETHERNET SERVICES The Ethernet services are provided by means of an internal Layer-2 Ethernet switch that fully complies with the IEEE 802.3/Ethernet V.2 standards, and has full VLAN support. The external Ethernet ports can be ordered with two types of interfaces: 10/100BaseTx interfaces terminated in RJ-45 connectors. Sockets for Fast Ethernet SFP transceivers. RAD offers several types of SFPs with optical interfaces, for meeting a wide range of operational requirements (SFPs with copper interfaces are also available).

The Ethernet switch switches traffic between the module Ethernet ports, including ETH over SHDSL, and the CL module Ethernet traffic subsystem (for connection via the CL GbE ports to a packet-switched network, or for transmission through the SDH network via virtually concatenated groups (VCGs), and between module Ethernet ports and bundles. ASMi-54C implements the IEEE's 802.1Q standards to provide VLAN-tagging with levels of prioritization, enabling carriers to offer differentiated Ethernet services. VLAN tagging can also be employed to separate traffic, ensuring transparency of the customer traffic and bolstering security of management traffic.

ASMI-54C/ETH MODULE ASMi-54C/ETH can operate as a Central SHDSL.bis (STU-C) or Remote (STU-R) SHDSL.bis Termination Unit working with up to 8 ASMi-54/ASMi-54L standalone devices or another ASMi-54C module. When providing Ethernet services and operating as STU-R, ASMi-54C/ETH performs line probing according to G.991.2. When enabled, the DSL interface adapts its rate to the condition of the line (noise, loop attenuation, etc.). When disabled, the DSL line operates at a fixed rate selected by the user. The SHDSL line supports TPS-TC framing 64/65 for EFM (IEEE 802.3) and HDLC (G.991.2). The processing and switching of Ethernet traffic over TDM (SHDSL) links is configured by means of PCS (Physical Coding Sublayer) using EFM or HDLC as the Layer-2 protocol. EFM bonding on the Ethernet interface ensures that a failure or addition of a link does not drop the traffic being transmitted over the other wires in the group. The capacity of the group is not affected when a new link is added at a lower rate.

Note. It is strongly recommended to order this device with original RAD SFPs installed. This will ensure that prior to shipping, RAD has performed comprehensive functional quality tests on the entire assembled unit, including the SFP devices. RAD cannot guarantee full compliance to product specifications for units using non-RAD SFPs.

Figure 3. Ethernet Service Extension over Copper Leased Lines

Data Sheet

E1 SERVICES E1 services are provided by /N options of the ASMi-54C module. To increase available SHDSL range, two pairs (4 wires) can be bonded to operate in the M-pair (HDLC) mode specified in ITU-T Rec. G.991.2. Bonding is available for lines handled by the same SHDSL section (the section handling either ports 1 to 4, or ports 5 to 8). The external line ports have userselectable balanced (120) or unbalanced (75) DSU interfaces. The framing mode is also user-selectable, in accordance with the required handling of the port traffic: G.704 basic with or without CRC-4, or unframed. TDM MAPPING The DS0 cross-connect matrix of the Megaplex-4100 chassis enables flexible payload routing in the ASMi-54C/N modules, independently configurable for each port, at the individual timeslot (DS0) level. REMOTE POWER FEEDING The ASMi-54C/E1/ETH/N module has a special remote power feeding variant that delivers power and data over 2 or 4 wires to up to 4 SHDSL/SHDSL.bis remote modems or repeaters and eliminates the need for locally powered modems or repeaters. The power feeding model occupies two adjacent slots in the Megaplex-4100 chassis.

Each pair of SHDSL ports/lines (1&2, 3&4, 5&6, 7&8) is handled as a power feeding group. The 4 groups are called: A,B,C,D, each group carrying the power to a separate remote device. Two 4-section DIP switches (external and internal) enable selective power feeding for each individual line. When working in 2W in a specific group, only the first port carries the power, while the second port operates transparently without carrying any power. When working in a specific group in 4W mode, the power is transferred over both ports of this power feeding group. While some of the SHDSL/SHDSL.bis lines are used for remote power feeding, the rest of the lines can be used for regular data transfer. Table 2 illustrates the number of free lines that can be used for data transfer depending on the number and type of lines engaged in power feeding.

The module supplies each line with 180 VDC at a maximum of 60 mA with current limit protection for each channel. Front-panel LEDs indicate the power feeding status for each line and provide warnings for current and temperature overload conditions. MANAGEMENT Setup, control, and diagnostics are performed in the following ways: Via ASCII terminal connected to a supervisory port on the Megaplex-4100 CL module Via management station connected to a dedicated 10/100BaseT Ethernet port on the Megaplex-4100 CL module Using inband management with dedicated VLAN for managing remote units (ASMi-54/ASMi-54L.) Using EOC from the central ASMi-54C module for managing remote units (ASMi-52/ASMi-52L).

MONITORING Performance statistics for the SHDSL, Ethernet, PCS (Physical Coding Sublayer) and E1 ports may be obtained and analyzed via the Megaplex-4100 management system.

Table 2. Power Feeding and Data Lines

Line Type 2W 4W 2W 4W 2W 4W 2W 4W

Groups Engaged in Data Transfer with Power Feeding 0 1 1 2 2 3 3 4 4 Group (2W) Group (4W) Groups (2W) Groups (4W) Groups (2W) Groups (4W) Groups (2W) Groups (4W)

Lines Left for Data Transfer without Power Feeding 8 7 3 6 2 5 1 4 0 x x x x x x x x 2W 2W 4W 2W 4W 2W 4W 2W

ASMi-54C Ethernet and TDM over SHDSL/SHDSL.bis 8-Port Modules

Specifications
SHDSL/SHDSL.bis INTERFACE Number of Ports 8 Number of Wires ASMi-54C/ETH: 2, 4, 8 ASMi-54C/N: 2, 4 Compliance ITU-T G.991.2, ETSI TS 101524 Data Rate 192 to 22784 kbps (n 64 kbps, n = 3 to 356)
Note: The SHDSL data rate depends on the module type, number of wires and far-end device

Connectors 2 x RJ-45, shielded 2 x SFP transceivers (see Ordering)) SFP Transceivers For full details, see the SFP Transceivers data sheet at www.rad.com Maximum Frame Size ASMi-54C/N (all models): 9600 bytes ASMi-54C/ETH: 1522 bytes E1 INTERFACE Number of Ports 8 Coding HDB3 Line Impedance Balanced E1: 120 Unbalanced E1: 75 (via adapter cable) E1 Jitter Performance As per ITU G.823 Connector DB-44 convertible to RJ-45 or BNC connectors via adaptor cables INDICATORS (PER ETHERNET PORT) ASMi-54C/N LINK/ACT On (green): link is up Off: link is down Flashes: frames are transmitted/received 100 On (yellow): 100 Mbps mode Off: 10 Mbps mode

ASMi-54C LINK (green) LAN link integrity ACT (yellow) LAN data activity POWER FEED (ASMI-54C/E1/ETH/N) Number of Ports 8 (4 line groups A,B,C,D) supporting 4 remote units Power Feeding 180 VDC at 60 mA maximum per group Connectors Single-pair female 2-pin terminal block per port

Signal Format With remote ASMi-52/52L: TC-PAM16 With remote ASMi-54/54L: TC-PAM32/TC-PAM16 Impedance 135 Connectors DB-26 convertible to 8 RJ-45 connectors via adaptor cable (regular model) Single-pair female 2-pin terminal block for each port (power-feed model) Typical Range See Table 3 ETHERNET INTERFACE Number of Ports 2 UTP or 2 fiber-optic Data Rate 10/100 Mbps (Fast Ethernet) Autonegotiation (copper only)

Table 3. Typical Ranges over 2W@26 AWG Cable Data Rate [kbps] 192 1536 2048 4096 4608 5696 Ranges [km] 6.6 4.9 4.5 3.2 3.0 2.6 [mi] 4.1 3.0 2.8 2.0 1.9 1.6

Note: The typical ranges are based on error-free lab tests without noise and obtained on a 26 AWG cable line simulator (DLS-400). For ASMi-52/52L on the far end, only ranges up to 2048 are relevant.

Data Sheet

Power Feeding Control Switches External 2-position DIP switch per group for operation control Internal 2-position DIP switch per group for 2/4-wire operation control LED Indicators 4 dual-color P-FEED LEDs on the front panel. Each LED indicates the condition of a specific line group: Off No digital power is supplied to the ASMi-54C/N card Steady green light The line group carries power of 180 VDC Blinking green The line group front-panel DIP-switch is off Steady red light ASMi-54C/N suffers from overheating Blinking red: The line group suffers from leakage current to the ground 48 VDC is not supplied to the ASMi-54C/N module

GENERAL Diagnostics (ASMi-54C/N only) Local and remote loopbacks on local E1 ports, per port and per timeslot Remote loopbacks on E1-i ports connected to remote units (per port) Remote loopbacks on remote SHDSL ports (ASMi-52/ASMi-52L only) BER Test on local framed E1-i ports, per timeslot (ASMi-54C/N only) BER Test on local unframed E1-i ports, per port (ASMi-54C/N only)

Performance Monitoring Per ITU-T Rec G.991.2, G.826 Power Consumption ASMi-54C/ETH: 14.5W ASMi-54C/E1/N: 7.3W ASMi-54C/E1/ETH/N: 12W Environment Operating temperature: 0C to 45C (32F to 113F) Storage temperature: -20C to 70C (-4F to 158F) Humidity: up to 95%, non-condensing

Table 5. ASMi-54C Model Comparison

ASMi-54C/ETH

ASMi-54C/E1/N

ASMi-54C/E1/ETH/N

Line type Remote CPE

SHDSL.bis ASMi-54 ASMi-54L

SHDSL/SHDSL.bis ASMi-54 ASMi-54L ASMi-52 ASMi-52L

SHDSL/SHDSL.bis ASMi-54 ASMi-54L ASMi-52 ASMi-52L E1 and Ethernet data over 1 or 2 pairs STU-C 2W/4W M-pair Ver 3.0

Data transfer Central/Remote Number of wires EFM/M-pair Supported in

Ethernet data over 1, 2 or 4 E1 data over 1 or 2 pairs pairs STU-C/ STU-R 2W/4W/8W EFM Ver 2.1, Ver 3.0 STU-C 2W/4W M-pair Ver 3.0

Data Sheet
ASMi-54C Ethernet and TDM over SHDSL/SHDSL.bis 8-Port Modules

464-153-01/12 Specifications are subject to change without prior notice. 19882012 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders.

Ordering
STANDARD CONFIGURATIONS MP-4100M-ASMi-54C/E1/N E1 over SHDSL/SHDSL.bis 8-Port Module (available starting from version 3.0) MP-4100M-ASMi-54C/ETH/UTP Ethernet over SHDSL.bis 8-port module with UTP connectors MP-4100M-ASMi-54C/E1/ETH/UTP/N E1 and Ethernet over SHDSL/SHDSL.bis 8-port module with UTP connectors (available starting from version 3.0) SPECIAL CONFIGURATIONS MP-4100M-ASMi-54C/ETH/# Ethernet over SHDSL.bis 8-port module MP-4100M-ASMi-54C/E1/ETH/#/N E1 and Ethernet over SHDSL/SHDSL.bis 8-port module (available starting from version 3.0) MP-4100M-ASMi-54C/E1/ETH/#/PF/N E1 and Ethernet over SHDSL/SHDSL.bis 2-slot module with remote power feeding (available starting from version 3.0)
Note: Power feeding modules require a -48 VDC (nominal) source. This power can be provided by the 48 VDC-powered Megaplex-4100 chassis.

1D

2D

3D

10A

10B

18A

18B

Legend
# Interface and Connectors UTP 2 UTP (RJ-45 connectors) SFP-& 2 SFP sockets including SFP transceivers (see below for &) SFP transceivers for Ethernet & 100BaseFx Interface 1 Fast Ethernet/STM-1, 1310 nm, multimode, LED, 2 km (1.2 mi)

19A

19B

Fast Ethernet/STM-1, DDM, internal calibration, 1310 nm, multimode, LED, 2 km (1.2 mi) Fast Ethernet/STM-1, 1310 nm, single mode, laser, 15 km (9.3 mi) Fast Ethernet/STM-1, DDM, internal calibration, 1310 nm, single mode, laser, 15 km (9.3 mi) Fast Ethernet/STM-1, 1310 nm, single mode, laser, 40 km (24.8 mi) Fast Ethernet/STM-1, DDM, internal calibration, 1310 nm, single mode, laser, 40 km (24.8 mi) Fast Ethernet/STM-1, Tx - 1310 nm, Rx - 1550 nm, single mode (single fiber), laser (WDM) , 20 km (12.4 mi) Fast Ethernet/STM-1, Tx - 1550 nm, Rx - 1310 nm, single mode (single fiber), laser (WDM) , 20 km (12.4 mi) STM-1/OC-3, Tx - 1310 nm, Rx - 1550 nm, 9/25 single mode (single fiber), laser (WDM), 40 km (24.8 mi) STM-1/OC-3, Tx - 1550 nm, Rx - 1310 nm, 9/25 single mode (single fiber), laser (WDM), 40 km (24.8 mi) STM-1/OC-3, Tx - 1490 nm, Rx - 1570 nm, 9/25 single mode (single fiber), laser (WDM) , 80 km (49.7 mi) STM-1/OC-3, Tx - 1570 nm, Rx - 1490 nm, 9/25 single mode (single fiber), laser (WDM) , 80 km (49.7 mi)

Notes.

For the complete list of SFPs, refer to the SFP Transceivers data sheet.

It is strongly recommended to order ASMi-54C with original RAD SFPs installed. This will ensure that prior to shipping, RAD has performed comprehensive functional quality tests on the entire assembled unit, including the SFP devices. RAD cannot guarantee full compliance to product specifications for ASMi-54C units using non-RAD SFPs.

OPTIONAL ACCESSORIES CBL-DB26-8SHDSL Cable for splitting a single 26-pin SHDSL.bis connector to 8 x RJ-45 connectors
Note: This cable is required for the module operation. It can either be ordered from RAD or manufactured by the customer according to pinouts provided in the manual.

CBL-G703-8/RJ45/ST Splitter cable for splitting the 44-pin E1 connector to 8 E1 balanced RJ-45 connectors CBL-G703-8/RJ45/X Splitter cross-cable for splitting the 44-pin E1 connector to 8 E1 balanced RJ-45 connectors CBL-G703-8/COAX Splitter cable for splitting the 44-pin E1 connector to 8 pairs of E1 unbalanced BNC connectors CBL-G703-8/OPEN/2M Open-ended cable with DB-44 connector for balanced E1 applications All cables are 2m (6.6 ft) long.

International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail [email protected]

North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail [email protected]