System Sensor 100 Series Plug-in Smoke Detectors offer superb performance and reliability in a profile which is just 2 (5.1 cm) deep. Features
Sleek, low-profile design Compatible with 400 Series product Two LEDs blink in standby, providing 360 visibility Broad range of adapter bases available with built-in shorting spring Hand-held sensitivity reader available Model 2151 (photoelectric sensor) and model 2151T (photoelectric sensor with thermal) can be used with a variety of adapter bases in several wiring configurations and voltages. Other features include: low current draw, stable performance in high air velocities, built-in tamper resistant base design, remote LED option, removable cover and built-in test switch. The 100 series is designed to meet the performance criteria designated by UL. The sensing chamber is sealed against back pressure air flow. The chamber top is covered by a one piece molded screen which minimizes the entry of dirt and insects. This screen can be removed for cleaning. Additional key features include a variety of mounting bases and a full line of accessories. All 100 Series photoelectric smoke detectors contain a unique optical sensing chamber designed to sense smoke particles produced by a wide range of combustion sources. A custom integrated circuit incorporates signal processing to reduce false alarms. Model 2151 photoelectric detectors unique optical sensing chamber is engineered to sense smoke by a wide range of combustion sources. Dual electronic thermistors add 135F fixed temperature thermal sensing on model 2151T.
Agency Listings
S911
CS308
7272-1653:0122
3025009
2180
Adapter Base Selection Guide Base Model Number Loop Type B110LP B110RLP B112LP B114LP B116LP B401 2-wire* 2-wire* 4-wire 4-wire 2-wire* 2-wire*
*Functionality contingent on panel compatibility Must be limited by control panel Flangeless base
Resistive or Inductive (60% power factor) load. 2.0A at 30 VAC/DC 0.6A at 110VDC, 2.0A at 30VDC 1.0A at 125VAC, 2.0A at 30VAC 3 Octagon No Yes Yes No 4 Octagon No Yes Yes Yes 4 Square No Yes Yes Yes 50 mm Yes No Yes No 60 mm Yes No Yes No 75 mm No No Yes No
Junction Box Selection Guide* Base Model Number Single Gang B401 No B110LP/RLP B112LP/B116LP B114LP Yes Yes No
*Box depth contingent on base and wire size. Refer to National Electrical Code or local applicable codes for appropriate recommendations.
Ordering Information
Part No. 2151 2151T Accessories F110 RA100Z SENS-RDR SMB600 EOLR-1 M02-04-01 M02-09-00 XR-2B XP-4 C58-227-01 Description Low-profile photoelectric detector. Must be mounted to one of the B100 Series or B400 Series bases listed in the Adapter Base Selection Guide. Low-profile photoelectric detector with thermal. Must be mounted to one of the B100 Series or B400 Series bases listed in the Adapter Base Selection Guide. Accessory Flange Ring for 6 Base Remote annunciator for 2 or 4 wire systems, 332V. Fits standard single gang electrical box. Hand-held sensitivity reader. Surface mounting kit (flanged) End of line relay for power supervision, 12/24 VDC systems. Test magnet. Test magnet with 32 telescoping handle. Detector removal tool. Allows installation and/or removal of 100 Series detector heads from base in high ceiling installations when used with XP-4. Extension pole for XR-2B. Comes in three 5 ft. sections. Replacement dust cover for 100 Series smoke detectors.
3825 Ohio Avenue St. Charles, IL 60174 Phone: 800-SENSOR2 Fax: 630-377-6495
2011 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. A05-0182-015 11/11 #2709