PASOLINK INTRODUCTION
PLUS
PASOLINK FAMILY
SERIES/MODEL SYSTEM MODULATION INTERFACE
NECITR-YTC ART-FEB/04-01
PASOLINK V3
PDH
4PSK
2x2MB 4x2MB 8x2MB 16x2MB 1x8MB 1x34MB 2x2MB 4x2MB 8x2MB 16x2MB (2x10/100Base-T) 8x2MB 16x2MB 1 x 34MB
PASOLINK V4
PDH
4PSK
PASOLINK+
PDH
16QAM + RS
FEATURES
ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE Single chip modulator/ demodulator (Full digital)
NECITR-YTC ART-FEB/04-01
MIC, MMIC, HIC and VLSI all solid state circuitry from data input to RF input
FEATURES
EASY AND QUICK INSTALLATION Very compact and light Only one coaxial cable interconnection Different mounting methods for IDU, ODU and Antenna Easy antenna pointing adjustments (RX level monitor point in ODU) TX POWER CONTROL Automatic Transmit Power Control (ATPC) Manual Transmit Power Control (MTPC) SYSTEM FLEXIBILITY (1 + 0 ) unprotected (1+1) Hot standby or Twin path Space and frequency diversity
NECITR-YTC ART-FEB/04-01
FEATURES
EASY MAINTENANCE FACILITIES Full front panel access for all cabling and user interfaces IF, Near End Base-Band and Far End Base-band Loop back facilities
NECITR-YTC ART-FEB/04-01
FEATURES
PASOLINK NETWORK MANAGEMENT SYSTEM (PNMS) (OPTION) User friendly operation Uses Windows NT/2000 to ensure easy operation and maintainability Remote access and control of any PASOLINK Terminal in the network Link oriented monitor and control ( both side of a microwave link) Multi level security Event Logging ITU-T G.826 Performance Monitor (Table /graph presentation) SNMP Interface (Option) Real-time monitor of Network Elements (NE) PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) (OPTION) User friendly operation as maintenance terminal Link oriented monitor and control
NECITR-YTC ART-FEB/04-01
System Composition
1- Indoor unit (IDU) ( Modulation-Demodulation unit) 2- Outdoor unit (ODU) ( Transmit Receive unit) 3- IF cable and connectors ( To connect the IDU & ODU) 4- Antenna on the required microwave band 5- Hybrid ( coupler ) in case of 1+1 one antenna configuration 6- RF cable ( If the ODU is not direct mounted to the antenna)
ODU (High band)
TX/RX RF ODU (low band) TX RX Antenna IF RX TX/RX TX Antenna IF RF
NECITR-YTC ART-FEB/04-01
MODEM IDU
MODEM IDU
Equipment
NECITR-YTC ART-FEB/04-01
NECITR-YTC ART-FEB/04-01
1+1 switch
NECITR-YTC ART-FEB/04-01
10
NECITR-YTC ART-FEB/04-01
WG OUTPUT ( Interface with the antenna ) ODU IDU CONNECTOR ( Ntype connector)
OW/RX LEV CONNECTOR
11
NECITR-YTC ART-FEB/04-01
RF IN/OUT SMA CONNECTOR (COAXIAL) IFL - IF IN/OUT N- type CONNECTOR (COAXIAL) RX LEV MON OW CONNECTOR
12
ODU composition
NECITR-YTC ART-FEB/04-01
13
NECITR-YTC ART-FEB/04-01
14
System Configuration
A- Non protected system (I+0)
TX IDU ( 1+0 ) ODU RX RX TX ODU
NECITR-YTC ART-FEB/04-01
IDU ( 1+0 )
15
System Configuration
C- Protected system (1+1) hot standby Space diversity Double antenna configuration
TX/RX ODU-1 Modem-1 Switch Modem-2 TX Rx only ODU-2 RX RX RX RX TX TX/RX ODU-1 Rx only ODU-2
NECITR-YTC ART-FEB/04-01
ODU-1
Modem-1 Switch Modem-2 TX TX\Rx TX ODU-2 RX RX
ODU PERFORMANCE
ITEM
Frequency Range [GHz] TX Output Power (dBm) STM-1 (128 QAM)
NECITR-YTC ART-FEB/04-01
6/7/8 GHz
5.9-8.5
11 GHz
10.7-11.7
13 GHz
12.7513.25 16.5
15 GHz
18 GHz
23 GHz
21.2-23.6
26 GHz
24.5-26.5
38GHz
37-40 GHz 10.5
14.5-15.35 17.7-19.7
+25
16.5
16.5
15.0
15
14.0
-68.0
-67.0
-67.0
-67.5
-67.5
-67.5
-67.0
-66.0
-69.0
-68.0
-68.0
-68.5
-68.5
-68.5
-68.0
-67.0
93.0
83.5
83.5
84.0
82.5
82.5
81.0
76.5
94.0
84.5
84.5
85.0
83.5
83.5
82.0
77.5
.
PASOLINK PLUS INTRODUCTION - STM1 17
PERFORMANCE
ITEM Frequency Range [GHz] Channel Spacing (MHz) STM-1 Narrow Band 6/7/8 GHz 5.9-8.5 11 GHz 10.7-11.7 13 GHz 12.7513.25 15 GHz 14.515.35 17.719.7 21.223.6 27.5 ( 28 )
NECITR-YTC ART-FEB/04-01
Frequency stability
ATPC and MTPC Range Tuning Bandwidth Ambient Temperature Range EMC Power Supply (48 V ) Typical Power Consumption Center Tuned
10 ppm (0.001%)
128 QAM: -20 to 0 dB in 1 dB steps Up to 50 MHz Depends on T-R spacing Up to 370 MHz (Depends on TX - RX spacing)
-33OC to + 50OC Conforms to ETS300 385 Class B 36 to 60 VDC ( 24V option) (1+0) system : 6-8 GHz 65W, 11-38 GHz 55W , (1+1) system : 6-8 GHz 130W, 11-38 GHz 110W
.
PASOLINK PLUS INTRODUCTION - STM1 18
IDU Performance
ITEM Modulation Symbol Frequency Narrowband STM-1/OC3 128QAM 24.236883 MHz
NECITR-YTC ART-FEB/04-01
Demodulation
Forward Error Correction Additional Attenuation Data Interface SOH Termination BB Loopback IF Loopback
Coherent detection
Reed-Solomon Coding 5 dB for span equalization Electrical / Optical / LAN RST Mode Far End / Near End Local only
PASOLINK PLUS INTRODUCTION - STM1 19
STM-1 PERFORMANCE
INTERFACES
ITEM STM-1 electrical Type STM-1 Optical Type STM-1 Optical Type ( Mono Fiber) STM-1/OC3 ITU T G.703 155.520 Mbit/s (CMI), 1 VP-P 75 ohms unbalanced ITU T G.957: S-1.1 155.520 Mbit/s (NRZ), (Intra Office) wave length 1310 nm, 155.520 Mbit/s, (NRZ), TX wave length : A:1310 nm , B: 1550 nm RX wave length : A:1550 nm, B: 1310 nm Mean optical output power: -7 dBm Minimum Receive overload power : -3 dBm Minimum Receive Sensitivity : -23 dBm
NECITR-YTC ART-FEB/04-01
Narrowband STM-1/OC3
1 Channel 1.544 Mbps 2.048 Mbps 3.0VO-P (100ohms bal) 2.37VO-P(75ohms unbal) 3.0VO-P(120ohms bal) B8ZS or AMI HDB3 10-Base T, RJ 45 Connector @ WS Rate
LAN Interface (option) Digital Service Channel (DSC) Voice Frequency Service Channel (VF) Housekeeping Alarms / Control IDU ODU connection (IFL)
2 Channels , (V11 contra / co-directional) selectable, 64 Kbps, 100 ohms 2 Channels, 4 wire, (0.3 to 4KHz) -6 dBm (nominal), 600 ohms balanced Input (Alarms) 6 photo coupler Output (Control) 4 Form-C dry contact relays Single coaxial cable , 50ohms 300m (8D-FB type cable), 350m (10D-FB type cable), 450m (12D-FB type cable)
20
NECITR-YTC ART-FEB/04-01
140 MHz -15 to -55 dBm
50 Ohms Unbalanced
MODEM No.1
OR
OPT INTFC
STM-1 OUT
OR 10/100Base-T MODEM No.2 EOW Way side 10 BASE-T WAYSIDE INTFC LAN CARD ODU INTFC No.2 IF IN/OUT
CONTROL
WAY SIDE IN/ OUT DATA SPEED LEVEL IMPEDANCE 1.544 Mbps / 2.048 Mbps 3.0 V0-P/ 2.37VO-P / 3.0 VO-P 100 Ohms, Balanced/75 ohms unbalanced / 120 ohms balanced PNMT EOW2 E0W1 LCT NE1 RS-422-64K FREQUENCY LEVEL IMPEDANCE 0.3 to3.4 KHz -6 dBm 0.3 to3.4 KHz -6 dBm 600 Ohms NE2 PNMS V11 V.11 PNMS LAN 10 BASE-T 100 Ohms RS-485 100 Ohms 100 Ohms
INTERFACE
RS-232C RS-232C
IMPEDANCE
21
INDICATORS/SWITCHES/CONTROLS (1+1)
No 1 Power indicator Light When power switch is ON
NECITR-YTC ART-FEB/04-01
MAINT LED Maintenance Mode ON Loopback control ON CW mode ON TX Power Mute ON ALS MANUAL RESTART ATPC MANUAL CONTROL
PWR SW Turns input DC power ON/OFF
ODU1 and ODU2 ALM LED Transmit RF power decrease by 3 to 6 dB from nominal Receiver level goes below squelch level ODU local oscillator APC loop unlock IF signal from the IDU is low
IDU1 and IDU2 ALM LED Input STM-1 Signal lost (from MUX ) -Main INTFC Input STM-1 Frame Sync lost (from MUX)- Main INTFC Service Channel Input Signal Lost - Modem E-BER worse than preset value (10 -3 to 10-5) - Main INTFC BER-SD worse tha preset value (10 -5 to 10-9) - Main INTFC Input STM-1 Frame Sync lost from Radio - Modem E-BER from Radio worse than preset value (10 -3 to 10-5) Main INTFC BER-SD from Radio worse than preset value (10 -3 to 10-5) Main INTFC CPU of MD Unit failure - Modem RX side alarms include unit failure and IF input loss - Modem TX side alarms includes unit failure - Modem BER alarm (10-4 to 10-6 selectable) - Modem DC-DC CONV unit failure - DC-DC CONV LAN CARD / WS INTFC Module failure - LAN /WS INTFC Main INTFC Module failure - 150M INTFC/OPT INTFC
No.1 CH TX STATUS Lights when Modulator and Transmitter of No.1 CH is selected No.2 CH TX STATUS Lights when Modulator and Transmitter of No.2 CH is selected
No.1 CH RX STATUS Lights when Demodulator and Receiver of No.1 CH is selected No.2 CH RX STATUS Lights when Demodulator and Receiver of No.2 CH is selected
22
INDICATORS/SWITCHES/CONTROLS (1+0)
MAINT LED Maintenance Mode ON Loopback control ON CW mode ON TX Power Mute ON ALS MANUAL RESTART ATPC MANUAL CONTROL
PWR LED When power switch is ON
NECITR-YTC ART-FEB/04-01
ODU1 and ODU2 ALM LED Transmit RF power decrease by 3 to 6 dB from nominal Receiver level goes below squelch level ODU local oscillator APC loop unlock IF signal from the IDU is low
R SW
R SW Switch to previous program version after program update
IDU ALM LED Input STM-1 Signal lost (from MUX ) -Main INTFC Input STM-1 Frame Sync lost (from MUX)- Main INTFC Service Channel Input Signal Lost - Modem E-BER worse than preset value (10 -3 to 10-5) - Main INTFC BER-SD worse tha preset value (10 -5 to 10-9) - Main INTFC Input STM-1 Frame Sync lost from Radio - Modem E-BER from Radio worse than preset value (10 -3 to 10-5) Main INTFC BER-SD from Radio worse than preset value (10 -3 to 10-5) Main INTFC CPU of MD Unit failure - Modem RX side alarms include unit failure and IF input loss - Modem TX side alarms includes unit failure - Modem BER alarm (10-4 to 10-6 selectable) - Modem DC-DC CONV unit failure - DC-DC CONV LAN CARD / WS INTFC Module failure - LAN /WS INTFC Main INTFC Module failure - 150M INTFC/OPT INTFC
23
INDICATORS/SWITCHES/CONTROLS
ALM LED (WS INTFC MODULE) WS INTFC Module fail
NECITR-YTC ART-FEB/04-01
ALM LED (150M INTFC/OPT INTFC) Input STM-1 data signal is lost Input STM-1 frame sysnchronization is lost 150M intfc/opt intfc module fail E-BER alarm is detected SD alarm is detected
COLX/DUPLEX LED ( 10/100 BASE-T INTFC) WHEN SETUP MODE IS HALF DUPLEX MODE, AND COLLISION OCCURS
ALM LED (WS/ALM INTFC MODULE) WS/ALM INTFC FAILS CLOCK FOR CLUSTER ALARM IS LOST FRAME SYNCHRONIZATION IS LOST
WHEN 10/100 BASE-T AND ASSOCIATED EQUIPMENT IS LINKED. BLINKS WHEN DATA IS TRANSMITTED
ALM LED (10/100 BASE-T INTFC) 10/100 BASE-T MODULE FAIL RADIO FRAME SYNCHRONIZATION IS LOST E-BER ALM IS DETECTED SD ALM IS DETECTED LINK OF PORT1/PORT2 IS LOST
24
NECITR-YTC ART-FEB/04-01
PNMT PNMT DCD PNMT TXD PNMT RXD PNMT DRS GND PNMT DTR PNMT CTS PNMT RTS
LCT 1 2 3 4 5 6 7 8 LCT TXD LCT RXD GND LCT CTS LCT RTS 1 2 3 4 5 6 7 8
EOW1 EXT EOW1INPUT(+) EXT EOW1 INPUT (-) EXT CALL1 INPUT EXT EOW1 OUTPUT(+) EXT EOW1 OUTPUT(-) GROUND EXT CALL1 OUTPUT GROUND
1 2 3 4 5 6 7 8
SC IN / OUT D-SUB 37 (FEMALE) OH1(V11-1) IDT+ 1 20 OH1(V11-1)ICK+ 2 21 EOW2 OH1(V11-1)IFP+ 3 22 EXT EOW2OUTPUT(+) OH1(V11-1)DDT 4 23 EXT EOW2OUTPUT (-) OH1(V11-1)DCK+ 5 24 EXT CALL2 OUTPUT OH1(V11-1)DFP+ 6 25 EXT EOW2 INPUT(+) GROUND 7 26 EXT EOW2INPUT(-) OH2(V11-1)IDT+ 8 27 GROUND OH2(V11-1)ICK+ 9 28 EXT CALL2 INPUT OH2(V11-1)IFP+ 10 29 GROUND OH2(V11-1)DDT+ 11 30 OH2(V11-1)DCK+ 12 31 OH2(V11-1)DFP+ 13 32 GROUND 14 33 OH3(VF-1) I/P+ 15 34 OH3(VF-1) O/P+ 16 35 OH4(VF-2) I/P+ 17 36 OH4(VF-2) O/P+ 18 37 GROUND 19
RJ45
D-SUB 25 (FEMALE) ALM 1 14 ALM RL7 (NC) 2 15 ALM RL7 (COM) ALM RL7 (NO) 3 16 ALM RL6 (NC) ALM RL6 (COM) 4 17 ALM RL6 (NO) ALM RL5 (NC) 5 18 ALM RL5 (COM) ALM RL5 (NO) 6 19 ALM RL4 (NC) 7 20 ALM RL4 (COM) ALM RL4 (NO) 8 21 ALM RL3 (NC) ALM RL3 (COM) 9 22 ALM RL3 (NO) 10 23 ALM RL2 (NC) ALM RL2 (COM) 11 24 ALM RL2 (NO) ALM RL1 (NC) 12 25 ALM RL1 (COM) ALM RL1 (NO) 13
IF IN/OUT
1 2 3 4
STM-1 IN/OUT
RJ45 NE1 TXD+/RXD+ TXD-/RXDRXD+/TXD+ CK + CK RXD-/TXDGND GND RJ45 NE2 TXD+/RXD+ TXD-/RXDRXD+/TXD+ N.C N.C RXD-/TXDGND GND RJ45 RJ45
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
NMS RXD-
1 2 3 4 5 6
1 2 3 6
RJ45 LAN CARD MDI MDI-X TX+ RX+ TXRXRX+ TX+ RXTX-
NMS RD-
1 2 3 4/5 6 7 8 9
D-SUB 9 (FEMALE) WS IN/OUT IDT(+) Input Data Ground ODT(+) Output Data Ground IDT(-) Ground
ODT(-) Ground
HK1 Alm Input(+) HK2 Alm input(+) HK3 Alm Input(+) HK4 Alm Input(+) HK5 Alm Input(+) HK6 Alm Input(+) RL11(COM)HK1 RL10(NC)HK2 RL10(NO)HK2 RL9(COM)HK3 RL8(NC)HK4 RL8(NO)HK4 Ground
AUX ALM 1 14 2 15 3 16 4 17 5 18 6 19 7 20 8 21 9 22 10 23 11 24 12 25 13
D-SUB 25 (FEMALE) HK1 Alm Input(-) HK2 Alm Input(-) HK3 Alm Input(-) HK4 Alm Input(-) HK5 Alm Input(-) HK6 Alm Input(-) RL11(NC HK1 RL11(NO)HK1 RL10(COM)HK2 RL9(NC)HK3 RL9(NO)HK3 RL8(COM)HK4
25
INTERFACES
NECITR-YTC ART-FEB/04-01
NEC PASOLINK PLUS SYSTEM HAS THE FOLLOWING ITU-T STANDARD INTERFACES DIGITAL SIGNAL INTERFACES Main traffic STM-1 Electrical Type (ITU-T G.703): in station section, full functionality Bit Rate: 155.520 Mbit/s 20ppm Level: 1 Vp-p (nominal) (TX accepts 12.7dB cable loss at 78 MHz) Code Format: CMI Impedance: 75 ohms, unbalanced (nominal) Connector: IEC 169-13 Main traffic STM-1 Optical Type (ITU-T G.957): S-1.1 (Inter office) Bit Rate: 155.520 Mbit/s 20ppm Level: S-1.1 -8 to -15 dBm Connector FC/PC
26
INTERFACES
NECITR-YTC ART-FEB/04-01
Wayside Traffic Transmission using RFCOH (option, 32QAM and 128QAM Enhanced Ver. only) Bit Rate: 2.048 Mbit/s 50ppm/1.544 Mbit/s 130ppm Input/output Level: 2.37 Vo-p 75 Ohms/3.0 Vo-p/3.0 v (75 unbal 2Mbit/s)(120 bal 2Mbit/s)(100 bal1.544Mbit/s) Code format HDB-3/ AMI or B8Zs Connector
SOH Termination: RF INPUT / OUTPUT PORT Antenna direct mount type : 11-38 GHz NEC original interface Coaxial interface type : 6-8 GHz SMA Coaxial Connector ( N-type optional) Wave Guide interface type :
D-Sub 9 pin
RST
SERVICE CHANNELS
OVERHEAD SERVICE CHANNELS 1 2 3 4 5 6 EOW V-11 V-11 VF1 VF2 WS or Digital Analog Analog Digital Engineering Order Wire IDU-IDU, IDU-ODU, ODU-ODU 64Kbit/s V11 (Contra / Co-directional selectable) 100 Ohms, Balanced 4 wire , (0.3 ~ 3.4 KHz ) -6 dBm nominal , 600 Ohms, Balanced 1.544 or 2.048 Mbps, RFCOH( 32 QAM /128 QAM Enhanced Ver. only) or 10 Base T: 32 QAM use 2.048 RFCOH 128 QAM use DSC or RSOH(E1/F1) 64Kbps 128 QAM (Enhanced Ver) use 2.048 RFCOH
NECITR-YTC ART-FEB/04-01
LAN
Digital
Option
Service channels can be connected back-to-back at repeater stations. Service channels 2 to 7 can be mapped to DSC1 to DSC4 in the RFCOH and E1, F1 and DCCr* bytes from the LCT or PNMT. * DCCr available only in STM-1, 128QAM Enhance ver. only
PASOLINK PLUS INTRODUCTION - STM1
MUX
PASOLINK+
MUX
28
START UP / SHUTDOWN
No.1 CH Power Switch
NECITR-YTC ART-FEB/04-01
No.1 CH Line IN
STAR UP Check that the LINE IN voltage is between +20 V to +60V (or -20 V to -72 V) with a digital multi-meter, before connecting the power connector to the IDU Turn ON the Power switch on the IDU Allow equipment to warm up for at least 30 minutes SHUT DOWN Turn OFF the power switch on the front of the IDU
No.2 CH Power Switch
No.2 CH Line IN
29
PROTECTION SWITCHING
NECITR-YTC ART-FEB/04-01
Protection switching is provided in (1+1) Twin Path and Hot Standby systems. The receive side protection switching is performed by a Hitless Switch in the 150 M INTFC / OPT INTFC or 10/100BASE-T INTFC module.
Priority 1: Manual switching Control Manual switching is initiated from external equipment (LCT/PNMT) Priority 2: Automatic switching control For any alarm in the online equipment, traffic will be switched to the standby equipment automatically. TX and RX switchover are performed independently.
RX switching TX switching In the (1+1)HS system transmit switching is carried out by setting the standby ODU out put to off by Muting it. The data signal is transmitted in parallel to both CH1 and CH2. This apply to both HS and Twin Path configurations. When the Online RX CH fails or LOW BER Alarm is detected the ALM CONT circuit in the SW Board initiate a RX SW Control signal to switch to the standby CH provided it is in normal operating condition. Low BER Alarm FSYNC Alarm DEM Alarm
TX Switching, either initiated manually or automatically may cause a short interruption of the data. Modulator Alarm TX IF Input Alarm TX Power Alarm APC Alarm
SWITCHING PRIORITY ( Provisioning)
RX LEV Alarm
1.Non-Priority The switching condition used is non priority (non-homing). After switching the channel selected remains selected even if the alarmed channel is normalized
2. Priority No.1 When both channels are normal always selects CH1 as online. When CH1 is faulty automatically change to CH2 provided it is normal. When CH1 recovers return to CH1 automatically. PASOLINK PLUS INTRODUCTION - STM1 30
PROTECTION SYSTEMS
NECITR-YTC ART-FEB/04-01
NECITR-YTC ART-FEB/04-01
When the optical signal input to the main interface is lost, the ALS function automatically shuts the main interface output laser
ALS DELAY TIME The ALS delay time can be set to 60 or 180 or 300 sec.
32
NECITR-YTC ART-FEB/04-01
IDU
TX max TX min
Site (A)
Site (B)
PASOLINK PLUS INTRODUCTION - STM1
RX reference
33
NECITR-YTC ART-FEB/04-01
Fading
Rx Lev
High
The ATPC Control transmits the information on the receiving level to the opposite station and controls the transmission level of its own station in accordance with the receiving level of the opposite station.
ATPC hysteresis (provisioning)
The ATPC Control can be used in several configurations: ATPC - ATPC MTPC - ATPC ATPC - MTPC
Fading
34
LOOPBACK CONTROL
NECITR-YTC ART-FEB/04-01
(d)
(a) STM-1 near-end loopback (STM-1 LB1) at the 150M INTFC/OPT INTFC module (b) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC module from LCT (c) IF loopback (IF-LB) at the MODEM module (Local only) (d) STM-1 far-end loopback (STM-1 LB2) at the 150M INTFC/OPT INTFC Module from PNMT/PNMS Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from the PNMS and PNMT are disabled.
PASOLINK PLUS INTRODUCTION - STM1 35
OW COMMUNICATION
NECITR-YTC ART-FEB/04-01
Buzz
CALL
Back-to-back connection
Buzz
Buzz
Following Order-Wire communications are possible: Communication between Local IDU and Local ODU
NECITR-YTC ART-FEB/04-01
37
NECITR-YTC ART-FEB/04-01
OW ON/OFF SW when set to ON enables OW communication between the IDU and the ODU. VOL control Adjust the level of the OW RX signal.
Head set Jack connects the headset for OW communication RX LEV/OW IN connector connect the OW/RX Lev monitor to the ODU using the provided coaxial cable
PASOLINK PLUS INTRODUCTION - STM1 38
ALARM TABLE
DETECTING CIRCUIT ALARM CONDITION INPUT STM-1 SIGNAL IS LOST FROM MUX FRAME SYNCHRONIZATION OF INPUT STM-1 SIGNAL FROM MUX IS LOST BER IS WORSE THAN PRESET VALUE BER IS WORSE THAN PRESET VALUE (10-3 (10-5 TO TO 10-5 10-9 SELECTABLE) FROM MUX SIDE SELECTABLE) FROM MUX SIDE MODULE LED ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) ALM (150/OPT INTFC) COLX/DUPLEX(BLINK) (10/100BASE-T INTFC) ALM(10/100BASE-T INTFC) ALM(WS INTFC/LAN) ALM INITIATED MAIN INTFC LOS MAIN INTFC LOS E-BER MUX SD-MUX RECEIVE STM-1 SIGNAL FROM RADIO IS LOST FRAME SYNCHRONIZATION OF THE STM-1 SIGNAL RECEIVED FROM RADIO LINK IS LOST 150 / OPT INTFC BER IS WORSE THAN PRESET VALUE (10-3 TO 10-5 SELECTABLE) FROM RADIO SIDE BER IS WORSE THAN PRESET VALUE (10-5 TO 10-9 SELECTABLE) FROM RADIO SIDE E-BER DMR SD DMR MAIN INTFC COLLISION LINK SUB INTFC MD CPU ALM MOD ALM DEM ALM HIGH BERF ALM PS MODEM TX POWER ALM TX INPUT ALM RX LEV ALM APC ALM CABLE ALM
NECITR-YTC ART-FEB/04-01
LED INDICATION IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM
150M INTFC / OPT INTFC MODULE FAILURE 10/100BASE-T INTFC WSINTFC/LAN COLLISION CONDITION OCCURS LINK OF LAN (10/100 BASE-T INTFC) AND ASSOCIATED EQUIPMENT IS NOT ESTABLISHED WS INTFC/ LAN CARD MODULE FAILURE COMMUNICATION BETWEEN MIODULES FAIL MODULATOR FAILURE MODEM DEMODULATOR FAILURE AND INPUT IF SIGNAL LOSS BER IS WORSE THAN PRESET VALUE (10-4 TO 10-6 SELECTABLE) FROM RADIO SIDE DC-DC CONV FAILURE MODEM FAILURE TRANSMIT RF POWER INCREASE/DECREASE BY APPROX. 3 dB FROM NOMINAL TX IF SIGNAL FROM THE IDU IS LOST ODU RECEIVER INPUT ;EVE; DECREASES BELOW SQUELCH LEVEL(32QAM -81dBm, 128 QAM -72 dBm) APC LOOP OF THE LOCAL OSCILLATOR UNLOCK COMMUNICATION BETWEEN IDU AND ODU IS LOST WHEN EQUIPMENT IS SET TO ONE OR MORE OF THE FOLLOWING CONDITIONS MAINTENANCE MAINTENANCE MODE FAR END / NEAR END LOOPBACK ON / ATPC MANUAL CONTROL ALS MANUAL RESTART / MOD CW ON / MUTE ON (TX OUTPUT POWER MUTED)
IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM IDU 1 & 2 ALM ODU 1& 2 ALM ODU 1& 2 ALM ODU 1& 2 ALM ODU 1& 2 ALM ODU 1& 2 ALM
MAINT
MAINT
42
NECITR-YTC ART-FEB/04-01
FACTORY DEFAULT SETTING CAN BE CHANGED FACTORY DEFAULT FIXED CAN BE EITHER ALARM OR CONTROL ONLY ALARMS
Installations
NECITR-YTC ART-FEB/04-01
Before going to any site, please be sure you completely prepared the following items: 1-The installation tools. 2-The test equipment ,materials ,and tools.( for test work only) 3-Site installation drawings. 4-All labels/stickers (hard and soft copy) 5-Frequency plan and system configuration documents. 6-Test procedure and test data sheets .( for test work only) 7-Confirm access to site/station. 8-Check the condition of the vehicle to be used. 9-Make sure you and your staff are in good conditions (physically) 10-Confirm the site/station entrance conditions. 11-Move to site/station safely.
PASOLINK PLUS INTRODUCTION - STM1 45
1-INDOOR INSTALLATION
Unpacking of Accessories
Unpacking of IDU
IDU Mounting
Rack Earthing Connection
IF Cable Connection
NESIC CAIRO
46
IDU MOUNT
FRONT POSITION
More than one rack unit
NECITR-YTC ART-FEB/04-01
WALL
Align the IDU to the mount position When mounting the IDU in a 19 inch rack, leave a space of 200mm to the rear section and space of one rack unit to the top and bottom.
Fix each side of the IDU to the rack with (M5) screws
CENTER POSITION
More than one rack unit Mount the two brackets to the IDU with four screws Align the IDU to the center mount position and fix each side with (M5) screws PASOLINK PLUS INTRODUCTION - STM1 47
NECITR-YTC ART-FEB/04-01
NECITR-YTC ART-FEB/04-01
Luck Nut
Washer Gasket Clamp A Clamp B Insulation Center Conductor Connector Shell
IF Cable Termination
1-First, Fit the Lock Nut, Washer and Gasket on the Cable as shown
NECITR-YTC ART-FEB/04-01
Gasket
NECITR-YTC ART-FEB/04-01
2-Strip Back the cable sheath, taking care not to damage the braided shield.
Fit Clamp A
PASOLINK PLUS INTRODUCTION - STM1
NESIC CAIRO 51
NECITR-YTC ART-FEB/04-01
3-Fold back the Braided shield, Separating the strands of the braid. Cut the extra length, to fit to Clamp A
52
NECITR-YTC ART-FEB/04-01
4-Cut away the insulation from the center conductor and fit the clamp B.
Be sure not to cut or scratch the conductor while stripping the insulation
NESIC CAIRO 53
NECITR-YTC ART-FEB/04-01
5- Cut the center conductor to fit the connector center contact (~1.2cm). Taper the end of the center conductor using a file 6- Mount the center contact onto the center conductor
Insulation
54
NECITR-YTC ART-FEB/04-01
9- Tighten the Lock Nut. Insure the good tighten condition using the suitable wrench
NESIC CAIRO 55
NECITR-YTC ART-FEB/04-01
12- Cover the rubber tape with all weather vinyl tape.
NESIC 56 CAIRO
NECITR-YTC ART-FEB/04-01
57
NECITR-YTC ART-FEB/04-01
Power Cable
Socket Contact
NECITR-YTC ART-FEB/04-01
1 2
2- Set the socket contact to the following position onto the hand crimping tool
Crimping Type dia. of Cable 57026-5000 1.5 to 1.8 1.8 to 2.2 57027-5000 2.3 to 2.6 2.6 to 3.1
Position 1 2 1 2
NECITR-YTC ART-FEB/04-01
3- Squeeze the handle of the hand crimping tool, insert cable into socket contact
4- Cable should fit, so insulation and bare wire are arranged as shown,
5- Squeeze the handle of the hand crimping tool until ratchet is released.
60
NECITR-YTC ART-FEB/04-01
5-Squeeze the handle of the hand crimping tool until ratchet Is released
6- Insert socket contacts to power connector till they locked and be sure it is well fixed.
(-48 V)
(0 V)
NESIC CAIRO 61
NECITR-YTC ART-FEB/04-01
NESIC CAIRO 62
UNPACKING ODU
NECITR-YTC ART-FEB/04-01
6/7/8 GHz ODU Open the carton Take out the ODU with cushioning materials Remove the cushioning materials from the ODU Take out the ODU from the antistatic bag Inspect ODU
NECITR-YTC ART-FEB/04-01
NECITR-YTC ART-FEB/04-01
65
NECITR-YTC ART-FEB/04-01
Antenna
ODU 2
66
V /H POLARIZATION (1+1)
V - POLARIZATION
SCREWS
NECITR-YTC ART-FEB/04-01
NEC Hybrid
Quasar Hybrid
SCREWS
SCREWS
H - POLARIZATION
PROCEDURE FOR SETTING V/H POLARIZATION USING HYBRID ANTENNA SIDE Loosen the four screws with allen keys and rotate the antenna connection unit to the required polarization position Tighten the four screws. HYBRID SIDE The hybrid is set to V-polarization when shipped from the factory Remove the two screws. Rotate the two plates to the position required for the required polarization and fix them in position with the screws
67
NECITR-YTC ART-FEB/04-01
Remove the Blanking plate Mount the blanking plate here for reuse
1.Mount the Hybrid to the Antenna with screws, use the guide pins to position correctly
2.Fix the ODUs one by one to the Hybrid. Take care not to damage the o-rings.
68
NECITR-YTC ART-FEB/04-01
When vertical polarization is required, rotate the IDU so that the plate marked with V is pointing up. Fix the ODU in this position
When horizontal polarization is required, rotate the IDU so that the plate marked with H is pointing up. Fix the ODU in this position
69
USE OF O-RINGS
NECITR-YTC ART-FEB/04-01
70
NECITR-YTC ART-FEB/04-01
71
NECITR-YTC ART-FEB/04-01
NECITR-YTC ART-FEB/04-01
73
NECITR-YTC ART-FEB/04-01
Align the waveguide to the Hybrids Antenna port and fix it with four bolts.
Take care not to damage the O - ring
74
NECITR-YTC ART-FEB/04-01
Align the waveguide to the ODU Wave guide flange fix with four bolts.
Take care not to damage the O - ring
75
GROUNDING
NECITR-YTC ART-FEB/04-01
76
3- IDU Start up
NECITR-YTC ART-FEB/04-01
1-Be sure the power cable and IF cable are connected in Proper way 2- Carefully Poll out the Power On / Off toggle switch and put in ON position. 2- To shutdown the IDU switch the toggle switch to Off Position
1-Never switch IDU Off before at least 30 sec 2-Never connect or disconnect the IF Cable while the equipment is powered On 3-Leave the equipment to warm up
PASOLINK PLUS INTRODUCTION - STM1 77
NECITR-YTC ART-FEB/04-01
HyperTerminal
78
HyperTerminal setting
Type your Connection Name
NECITR-YTC ART-FEB/04-01
PTT
HyperTerminal setting
Select the setting items:
1-Bits/Second: 19200
NECITR-YTC ART-FEB/04-01
6- Press OK
HyperTerminal setting
From File menu select Properties
NECITR-YTC ART-FEB/04-01
500 3-Press ASC II setup Wrap lines that exceed terminal width
7- OK
8- OK
NESIC CAIRO
81
IDU Setting
Connect your PC to the IDU using supplied RS232 cable. Start up your HyperTerminal connection Follow the Commands as
Enter Login Name : Admin Enter Password : 12345678 Main Menu will appear as shown in below fig.
NECITR-YTC ART-FEB/04-01
Double Click
NESIC 82 CAIRO
IDU Setting
NECITR-YTC ART-FEB/04-01
This setting is just for test purpose From System Configuration menu For more details, please refer to instruction manual select 2
Enter TX Frequency & Press Enter Key Select TX Power Control to MTPC & Press Enter Key
PASOLINK PLUS INTRODUCTION - STM1
NESIC CAIRO 83
NECITR-YTC ART-FEB/04-01
84
IDU Setting
Start your antenna orientation and link test.
NECITR-YTC ART-FEB/04-01
1- At each station, press the 9 key twice for setting the Antenna Alignment mode of Maintenance and press the Enter key,
NESIC CAIRO 85
Antenna Orientation
NECITR-YTC ART-FEB/04-01
At each station remove the cap from the RX LEV MON connector. At each station connect cable between the RX LEV MON connector in the ODU and OW/RX LEV IN connector in the OW/RX LEV MONITOR unit or digital multi-meter. Adjust the azimuth and the elevation so as to maximize the RX LEV voltage indicated on the voltage display, one station at a time. AZ Angle Adjustment 1. Loosen the Bolt (Nut) EL Angle Adjustment 3. Loosen Bolts
2-1. Adjust AZ angle by the two Bolts (nuts) 2-2. Secure the Bolts (nuts).
After adjustment disconnect the RX LEV MONITOR /Digital Multi-meter Put back the cap on the RX LEV MON connector
ORDER-WIRE TESTS
NECITR-YTC ART-FEB/04-01
Connect the OW/RX LEV MONITOR to the RX LEV MON connector on the ODU.
Connect Headsets to the EOW Jacks on the front panel of the local and remote IDUs and Headset Jack on the OW/ RX LEV MONITOR. Press the Call Button on the local IDU and confirm that the buzzer on the opposite IDU is activated.. Confirm that OW communication between Local IDU and the Remote IDU is possible. Confirm that OW communication between Local IDU and the local ODU and/ or opposite ODU is possible Confirm that OW communication between Local ODU and the opposite ODU is possible
87
LCI to RS232
NECITR-YTC ART-FEB/04-01
88
RX Level Monitoring
NECITR-YTC ART-FEB/04-01
Low BER and High BER are fixed to 3 x 10-7 and 3 x 10-4.
PASOLINK PLUS INTRODUCTION - STM1 89
Network connections
NECITR-YTC ART-FEB/04-01