Cables Heliax
Cables Heliax
Cables Heliax
440
Index
General Information
HELIAX Coaxial Cable Cable Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 442 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 450 HELIAX Coaxial Cable Types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453 HELIAX Coaxial Cable...Todays Alternative to Braided Cable . . . . . . . . . . . . . . . 459 Connectors HELIAX Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 462 New OnePiece Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 464 HELIAX Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 471 Factory Made Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473
441
Nominal Size Catalog Pages Standard Cables Standard Black Jacket Fire Retardant Cables CATVX, VW-1, IEC 332-1 CATV, UL1581, IEC 332-3, IEEE 383 CATVR, UL1666 (Riser) Low VSWR Cables, Specially Tested Standard Black Jacket Special Application Cables Phase Stabilized; Phase Measured Characteristics Maximum Operating Frequency, MHz Peak Power Rating, kW Relative Propagation Velocity, % Minimum Bend Radius, in (mm) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz
1/2" 485 FSJ4-50B FSJ4RN-50B FSJ4RN-50B FSJ4RN-50B FSJ4P-50B-(**) p. 590 10200 15.6 81 1.25 (32) 0.557 (1.83) 1.04 (3.41) 2.31 (7.59) 3.60 (11.8) 5.37 (17.6) 10.5 (34.4) 14.6 (47.9)
FSJ1P-50A-(**) p. 590 20400 6.4 84 1 (25) 0.973 (3.19) 1.79 (5.89) 3.91 (12.8) 5.96 (19.6) 8.67 (28.5) 16.1 (52.7) 21.7 (71.2)
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature 100C (212F); no solar loading. 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz 2.28 1.23 0.567 0.372 0.256 0.138 0.102 3.97 2.14 0.975 0.634 0.431 0.228 0.166 5.76 3.09 1.38 0.889 0.598 0.307 0.220 3.99 2.15 0.978 0.635 0.431 0.227 0.165 12.3 6.62 2.99 1.93 1.31
** Insert suffix number from specific cable Catalog page. See specific Catalog page.
442
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1/4" 491 Standard Cables LDF1-50 LDF1RN-50 LDF1RN-50 LDF1RN-50 LDF1P-50-(**) p. 590 Characteristics 15800 12.1 86 3 (76) 0.667 (2.19) 1.23 (4.05) 2.71 (8.88) 4.16 (13.6) 6.10 (20) 11.5 (37.7) 15.7 (51.5)
3/8" 493 LDF2-50 LDF2RN-50 LDF2RN-50 LDF2RN-50 LDF2P-50-(**) p. 590 13500 15.6 88 3.75 (95) 0.563 (1.85) 1.04 (3.42) 2.29 (7.51) 3.52 (11.6) 5.17 (17) 9.79 (32.1) 13.4 (43.9)
1/2" 496 LDF4-50A LDF4RN-50A LDF4RN-50A LDF4RN-50A LDF4P-50A-(**) p. 590 8800 40 88 5 (125) 0.357 (1.17) 0.661 (2.17) 1.45 (4.75) 2.22 (7.28) 3.25 (10.7) 6.11 (20.1)
1-1/4" 513 LDF6-50 LDF6RN-50 LDF6RN-50 LDF6RN-50 LDF6P-50-(**) 3300 205 89 15 (380) 0.135 (0.444) 0.254 (0.832) 0.571 (1.87) 0.897 (2.94) 1.35 (4.43)
1-5/8" 520 LDF7-50A LDF7RN-50A LDF7RN-50A LDF7RN-50A LDF7P-50A-(**) 2500 315 88 20 (510) 0.109 (0.356) 0.205 (0.671) 0.467 (1.53) 0.742 (2.43) 1.13 (3.71)
2-1/4" 524 LDF12-50 LDF12RN-50 LDF12RN-50 LDF12RN-50 LDF12P-50-(**) 2200 425 88 24 (610) 0.091 (0.299) 0.173 (0.566) 0.400 (1.31) 0.644 (2.11) 0.994 (3.26)
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20C (68F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40C (104F); inner conductor temperature 100C (212F); no solar loading. 3.32 1.79 0.818 0.533 0.363 0.193 0.141 4.14 2.24 1.02 0.663 0.451 0.239 0.175 6.46 3.49 1.59 1.04 0.710 0.378 9.57 5.14 2.31 1.48 0.996 0.511 14.1 7.56 3.41 2.19 1.48 22.0 11.7 5.22 3.32 2.21 30.9 16.4 7.18 4.52 2.96 39.8 21.0 9.06 5.64 3.65
443
HELIAX Coaxial Cable Selection Guide - 50-ohm, Foam and Air Dielectric
High Power, High Temp, Superflexible, ETS Series Nominal Size Catalog Pages Standard Cables Fire Retardant Cables CATVP, UL910 PLENUM, jacketed Special Application Cables Phase Stabilized; Phase Measured Characteristics Maximum Operating Frequency, MHz Peak Power Rating, kW Relative Propagation Velocity, % Minimum Bend Radius, in (mm) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz 20000 6.4 82 1 (25) 0.97 (3.19) 1.79 (5.86) 3.86 (12.7) 5.86 (19.2) 8.46 (27.7) 15.4 (50.6) 20.6 (67.5) 13400 13.2 83 1 (25) 0.653 (2.14) 1.22 (3.99) 2.71 (8.89) 4.22 (13.8) 6.28 (20.6) 12.2 (40.1) 17 (55.8) 18000 6.4 82 1 (25) 0.911 (2.99) 1.68 (5.51) 3.65 (12) 5.57 (18.3) 8.10 (26.6) 15.0 (49.1) 20.2 (66.2) p. 591 p. 591 ETS1-50T ETS2-50T HST1-50 1/4" 477 3/8" 483 High Power, High Temp, Superflexible, HST Series 1/4" 529
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature (as noted); no solar loading. Inner Conductor Temperature, C (F) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz 200 (392) 5.48 2.98 1.38 0.909 0.629 0.345 0.259 200 (392) 9.89 5.31 2.38 1.53 1.03 0.529 0.381 250 (482) 3.60 1.95 0.897 0.588 0.405 0.219 0.163
** Insert suffix number from specific cable Catalog page. See specific Catalog page.
444
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Coaxial Cable Selection Guide - 50-ohm, Foam and Air Dielectric
High Power, High Temp., Superflexible, HST Series 3/8" 1/2" 533 549 Standard Cables Fire Retardant Cables HST2-50 Special Application Cables Characteristics 13400 13.2 83 1 (25) 0.667 (2.19) 1.23 (4.05) 2.70 (8.85) 4.13 (13.6) 6.04 (19.8) 11.3 (37.2) 15.4 (50.5) 10200 15.6 81 1.25 (32) 0.586 (1.92) 1.09 (3.58) 2.42 (7.93) 3.74 (12.3) 5.55 (18.2) 10.7 (35.1) 14.8 (48.6) 10000 6.4 84 1 (25) 0.941 (3.09) 1.73 (5.69) 3.75 (12.3) 5.70 (18.7) 8.24 (27.0) 15.1 (49.5) 20.2 (66.2) 13400 13.2 83 1 (25) 0.650 (2.13) 1.20 (3.94) 2.61 (8.56) 3.98 (13.0) 5.78 (19.0) 10.7 (35.1) 14.4 (47.2) 10200 15.6 81 1.25 (32) 0.512 (1.68) 0.947 (3.11) 2.07 (6.78) 3.16 (10.4) 4.62 (15.2) 8.63 (28.3) 11.7 (38.4) HST4-50 HS1RP-50A HS2RP-50 HS4RP-50 Plenum, Superflexible, HS-RP Series 3/8" 531
1/4" 527
1/2" 546
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20C (68F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40C (104F); inner conductor temperature (as noted); no solar loading. 200 (392) 9.98 5.40 2.47 1.61 1.10 0.588 0.433 200 (392) 15.6 9.29 4.19 2.71 1.83 0.947 0.685 100 (212) 1.56 0.850 0.393 0.259 0.179 0.098 0.073 100 (212) 2.69 1.46 0.670 0.439 0.302 0.164 0.121 100 (212) 3.31 1.79 0.821 0.537 0.368 0.197 0.145
** Insert suffix number from specific cable Catalog page. See specific Catalog page.
445
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature (as noted); no solar loading. Inner Conductor Temperature, C (F) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz 100 (212) 4.40 2.37 1.07 0.690 0.466 0.242 0.175 100 (212) 8.94 4.84 2.20 1.43 0.986 0.525 100 (212) 14.0 7.53 3.38 2.17 1.46 100 (212) 30.8 16.5 7.44 4.79 3.22 100 (212) 43.1 23.1 10.3 6.63 4.44
** Insert suffix number from specific cable Catalog page. See specific Catalog page.
446
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20C (68F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature (as noted); no solar loading. 121 (250) 81.9 0.141 0.340 10.6 121 (250) 123 64.7 27.6 17.1 100 (212) 159 84.5 37.1 150 (302) 335 172 70.8
** Insert suffix number from specific cable Catalog page. See specific Catalog page.
447
Nominal Size Catalog Pages Standard Cables Standard Black Jacket Fire Retardant Cables CATVX, VW-1, IEC 332-1 CATV, UL1581, IEC 332-3, IEEE 383 CATVR, UL1666 (Riser) CATVP, UL910 PLENUM, jacketed CATVP, UL910 PLENUM, unjacketed Special Application Cables High Power/High Temperature Characteristics Maximum Operating Frequency, MHz Peak Power Rating, kW Relative Propagation Velocity, % Minimum Bend Radius, in (mm) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature 100 C (212 F); no solar loading. Inner Conductor Temperature, C (F) 30 MHz 100 MHz 450 MHz 1000 MHz 2000 MHz 6000 MHz 10000 MHz 200 (392) 11.8 6.21 2.68 1.67 1.08 0.516 0.357 200 (392) 32.7 16.6 6.65 3.92 1.51 200 (392) 12.7 6.70 2.88 1.78 1.15 100 (212) 6.78 3.64 1.64 1.06 0.713 0.368
448
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Coaxial Cable Selection Guide - 75-ohm, Foam and Air Dielectric
Superflexible, FSJ Series 1/4" 1/2" 574 576 Standard Cables FSJ1-75 Fire Retardant Cables FSJ1RN-75A FSJ1RN-75A FSJ1RN-75A Special Application Cables Characteristics 22000 6.7 78 1 (25) 0.999 (3.28) 1.86 (6.12) 4.17 (13.7) 6.51 (21.4) 9.73 (31.9) 19.1 (62.7) 26.7 (87.6) 11500 10.0 81 1.25 (32) 0.514 (1.68) 0.958 (3.14) 2.14 (7.02) 3.34 (11) 4.98 (16.4) 9.78 (32.1) 13.6 (44.7) 10000 26 88 5 (125) 0.333 (1.09) 0.618 (2.03) 1.37 (4.5) 2.12 (6.97) 3.15 (10.3) 6.09 (20) 8.42 (27.6) 5300 70 89 10 (250) 0.195 (0.639) 0.366 (1.2) 0.834 (2.74) 1.32 (4.34) 2.01 (6.6) 5600 60 90 10 (250 0.209 (0.686) 0.388 (1.27) 0.850 (2.79) 1.29 (4.23) 1.92 (6.30) FSJ4RN-75A FSJ4RN-75A FSJ4RN-75A LDF4RN-75A LDF4RN-75A LDF4RN-75A HJ5RN-75 HJ5RN-75 HJ5RN-75 FSJ4-75A LDF4-75A LDF5-75 HJ5-75 Foam Dielectric, LDF Series 1/2" 7/8" 578 580 Air Dielectric, HJ Series 7/8" 582
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F).
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature 100 C (212 F); no solar loading. 100 (212) 1.06 0.570 0.255 0.163 0.109 0.056 0.040 100 (212) 3.30 1.77 0.794 0.509 0.341 0.174 0.125 100 (212) 3.10 1.67 0.753 0.486 0.328 0.170 0.123 100 (212) 5.65 3.00 1.32 0.832 0.548 100 (212) 9.31 5.01 2.25 1.49 0.977
449
Service Guarantee
At Andrew, were committed to exceeding our customers highest expectations by offering the best products backed by the most responsive service in the industry. So whatever our customers need, whenever and wherever they need it, we will deliver.
HELIAX connectors are designed exclusively for use with HELIAX coaxial cables to provide excellent electrical performance for the complete transmission line system. Low Attenuation The low attenuation of HELIAX coaxial cable results in highly efficient signal transfer which maximizes overall system performance. Complete Shielding Because HELIAX cable has a solid copper outer conductor, you get continuous RFI/EMI shielding to minimize interference and maximize system security.
450
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Reliable The availability of HELIAX cable in long, continuous lengths eliminates the need for joints which can affect reliability.
451
Fast Delivery Product availability is critical when you have a weather emergency or last minute design change that could result in downtime and lost revenue. In such situations, we respond quickly to get you on-the-air. Rapid product availability allows Andrew to be a real problem solver for you at installation time. With schedules to meet, you need to avoid delivery delays, contain costs, and get your system operating on time. With HELIAX coaxial cable from Andrew, you can do it. Large Variety of Sizes and Types The wide variety of HELIAX cable sizes and types lets you select the best cable for your specific application allowing more cost-effective planning. Optional fire-retardant, nonhalogenated jacketing is available to meet safety regulations for indoor installations. See Cable Selection Guide on pages 442 - 449. Factory Connector Attachment For your convenience, HELIAX cables can be ordered cut to length and factory fitted with connectors per your specifications. This service helps you avoid field assembly and testing.
452
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Foam dielectric (LDF Series) Flexible Feeder (VXL Series) Superflexible foam dielectric (FSJ and ETS Series) Extraflexible foam dielectric (EFX Series) Superflexible star dielectric (HS and HST Series) Air dielectric (HL, HT and HJ Series)
453
Superflexible and Extraflexible Cables HELIAX superflexible and extraflexible cables are designed for ease of installation in tight wiring spaces in shelters, radio rooms, and plenums. These cables are perfect for antenna and equipment room jumpers. Like all HELIAX cables, superflexible cables feature a solid outer conductor for unsurpassed electrical and mechanical performance. A polyethelene foam dielectric offers excellent electrical performance and prevents water migration.
Flexibility Andrew HELIAX superflexible cables are manufactured with deep, helical corrugations in the outer conductor. Extraflexible cables are manufactured with deep, annular corrugations. These exclusive corrugating processes permit Andrew cables and assemblies to be bent on very tight radii, without any degradation in performance. In addition, numerous reverse bends can be made, again without loss in performance. Superior Electrical Performance HELIAX cables and assemblies offer specifiers and users superior electrical performance in smaller sized cables. HELIAX cables and assemblies provide excellent attenuation and superior power handling and shielding versus comparably sized braided cables. Excellent Intermodulation Performance The solid inner and outer conductors found in all HELIAX cables minimize intermodulation generation. The braided outer conductors and stranded inner conductors that are
common in other cables form numerous contacts in the electrical path, which are sources of intermodulation. Complete Product Range Andrew now offers a complete range of cables to meet every application and budget requirement. HELIAX superflexible and extraflexible cables are available in a wide range of sizes and constructions for general use, plenum, and flame retardant applications. The HS series cables feature a star-shaped dielectric and superflexible construction. They are for use in plenum applications. The HST superflexible cables are for high power applications. These new cables feature a star-shaped dielectric which offers higher power handling at higher temperatures than any other flexible cable. A wide selection of connectors and factory manufactured assemblies in both standard and custom jumper configurations is available, to complement Andrew cable and make system planning easy and simple.
454
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
New VXL Series of Flexible Feeder Cables HELIAX flexible feeder cables are designed for use in difficult areas. They are more flexible than LDF series, while maintaining similar attenuation characteristics. 7/8" VXL5-50 is suitable for use as a one-piece feeder line from radio equipment to antenna, thus eliminating the need for jumper cables.
Superior Performance New VXL series flexible feeder cable uses advanced processing technology to provide a lower cost/higher performance solution that is ideal for wireless applications. System designers and engineers can eliminate the need for jumper cables when VXL5-50, a 7/8" feeder cable, is specified. It is suitable for continuous cable runs from the base station cabinet to the antenna. When used as one-piece feeder line, VXL5-50 requires no jumper cable from feeder to antenna. This eliminates extra connectors, lowering insertion loss, and minimizing installation time. Versatile and flexible, VXL series cable is also suitable for installation in difficult areas such as lift shafts, monopoles, and co-located sites. Lower Site Costs VXL5, VXL6, and VXL7 cables are lighter weight than standard series cables. The cable's reduced weight and tighter bending radius minimize installation time and lower site costs. Jumper cables are not required with
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747
VXL5-50. This means fewer connectors, less weatherproofing, and lower costs. The lighter weight of VXL series cable also reduces shipping costs. Outstanding Electrical Performance All VXL series cables have a closed-cell, foam polyethylene dielectric that prevents water migration and maintains its characteristics over time. The low-density foam provides low attenuation characteristics similar to LDF series cables. When used as a combined feeder/jumper solution, both system attenuation and system VSWR are optimized. Flexibility The VXL5 cable exhibits the tight bend radius of a 1/2" jumper. It, therefore, requires no jumpers when used as a main feeder. When the cable is used as a stand-alone jumper, it is the lowest-loss jumper solution in the industry.
455
Foam Dielectric Cables Superior Electrical Performance Like the FSJ and EFX cables, LDF cables have a closed-cell, foam-polyethylene dielectric that prevents water migration and maintains its characteristics over time. LDF cables are designed for low loss. Their lower density foam allows higher velocities and provides lower attenuation than FSJ cables. Attenuation characteristics approach those of air dielectric cables.
Flexibility HELIAX foam dielectric cables feature an annularly corrugated outer conductor that provides excellent shielding while offering flexibility. Complete Product Range LDF cables are available in sizes from 1/4" to 2-1/4" to meet application requirements for cellular and personal communications, land mobile radio, earth station antenna jumpers, equipment room and antenna jumpers, CATV, HF communications, VLF, military data links, AM and FM broadcast, terrestrial microwave, and CCTV. Phase stabilized versions are available.
Weatherproof Closed cell dielectric prevents water penetration. Connector O-rings seal out moisture. Excellent Intermodulation Performance Solid inner and outer conductors eliminate IM generated by numerous moving contacts in the current path that are found with stranded inner conductors and braided outer conductors. Quick and Easy Connector Attachment A range of self flaring connectors are available for easy field attachment requiring no special tools.
456
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Air Dielectric Cables HELIAX air dielectric cables from Andrew, available in 1/4" to 5" sizes, are designed to give you the lowest attenuation and highest average power rating. When these cables are equipped with the proper pressurization systems, they may be used in any indoor/outdoor environment. Air cables, if used indoors in a controlled environment, do not require pressurization.
The HJ air cables have a polyethylene or polypropylene spacer, and different jacketing materials dependent on fire retardancy requirements. High power HJ series cables use a special fluoropolymer spacer for maximum power handling with excellent attenuation. The cables are ideal for antenna feeder applications such as AM and FM radio, UHF and VHF TV, terrestrial microwave and earth station antenna systems, land mobile and cellular radio, ITFS, MMDS and MDS antenna systems, HF communications, military communications and radar. The HL air cables utilize a polyethylene spiral to space the inner conductor from the outer conductor, and a fluoropolymer jacket to provide fire retardancy. These cables are intended for indoor plenum type applications. The HT air cables use a fluoropolymer spiral to space the inner from the outer, and are unjacketed. These cables are for high temperature and/or high power applications.
Solid Copper Corrugated Outer Conductor Results in low loss, continuous RFI/EMI shielding to minimize interference and maximize system security. Corrugated outer conductor allows for ease of installation. High Power Handling Results from low attenuation and excellent heat transfer characteristics. Weatherproof/Pressure Tight HJ type cables have silicone gasketed connectors with 1/8" NPT pressure inlets. Connectors are designed to be pressure tight for maximum protection against water entry. System Integrity If a pressurized air-dielectric cable should be damaged, the pressurization system will alarm so that the leak can be corrected before water enters the cable and degrades performance. Rugged Construction HELIAX HJ cables are made with the strongest dielectric spacer in the industry, to withstand the stress of installation.
457
An extended ten-year warranty is now included, at no extra charge, on all new purchases of HELIAX coaxial cable, connectors and cable assemblies. Here are the details of this exclusive warranty: Complete coverage against defects in material and workmanship for HELIAX cables, connectors and assemblies. When connectors are attached by Andrew or an Andrew certified distributor, the attachment is also covered. Any HELIAX coaxial cable that has been fitted with non-Andrew connectors is expressly excluded from this extended warranty and is subject to the terms of the Andrew standard one-year warranty.
458
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Excellent Intermodulation Performance HELIAX coaxial cables and connectors minimize intermodulation generation by using solid conductors. Stranded inner conductors and braided outer conductors, used in many other cables, form numerous contacts within the current path which are a source of intermodulation. Complete RF Shielding Unlike braided cables, HELIAX coaxial cables have a solid corrugated copper outer conductor to protect against electromagnetic interface and radio frequency interference (EMI and RFI). Phase Stability HELIAX coaxial cables offer excellent phase stability over temperature variations and with bending. This makes them an excellent choice for phase-critical applications such as delay lines and matched feeders in phased-array antennas. Low Attenuation The continuous outer conductor and low loss polyethylene foam dielectric of HELIAX cables result in much lower losses than comparably sized braided cables. High Power Capability The excellent thermal conductivity and the low attenuation of HELIAX cables provide for higher average power handling capability when compared to comparably sized braided cables.
Flexibility HELIAX coaxial cables have excellent flexibility for ease of installation. These cables can be bent on small radii and will withstand repeated bends without degrading performance. Weatherproof and Durable for Outdoor Applications HELIAX coaxial cables are protected with a rugged black polyethylene jacket which provides abrasion resistance and complete environmental protection. Unlike braided cables, they can be used outdoors without the fear of water migration. Fire Retardancy HELIAX coaxial cables are available with special jacketing to meet relevant fire retardance standards. See page 626.
459
Attenuation, dB/100 ft (dB/100 m) Standard conditions: VSWR 1.0; ambient temperature 20 C (68 F). 150 MHz 450 MHz 824 MHz 960 MHz 1500 MHz 2000 MHz 4000 MHz 6000 MHz 10000 MHz 2.21 (7.25) 3.91 (12.8) 5.38 (17.6) 5.38 (19.1) 7.41 (24.3) 8.67 (28.5) 12.8 (41.8) 16.1 (52.7) 21.7 (71.2) 1.48 (4.86) 2.64 (8.66) 3.66 (12.0) 3.97 (13.0) 5.08 (16.7) 5.97 (19.6) 8.90 (29.2) 11.3 (37.2) 15.5 (50.8) 1.28 (4.21) 2.31 (7.59) 3.23 (10.6) 3.52 (11.6) 4.54 (14.9) 5.37 (17.6) 8.15 (26.7) 10.5 (34.4) 14.6 (47.9) 1.34 (4.39) 2.39 (7.83) 3.31 (10.8) 3.59 (11.8) 4.60 (15.1) 5.41 (17.8) 8.08 (26.5) 10.3 (33.8) 14.1 (46.3) 1.52 (4.99) 2.71 (8.88) 3.74 (12.3) 4.07 (13.3) 5.19 (17.0) 6.1 (20) 9.06 (29.7) 11.5 (37.7) 15.7 (51.5) 1.29 (4.24) 2.29 (7.51) 3.17 (10.4) 3.44 (11.3) 4.40 (14.4) 5.17 (17) 7.70 (25.3) 9.79 (32.1) 13.4 (43.9) 0.815 (2.67) 1.45 (4.75) 2.00 (6.56) 2.17 (7.12) 2.77 (9.09) 3.25 (10.7) 4.82 (15.8) 6.11 (20.1) 2.13 (6.99) 3.75 (12.3) 5.14 (16.9) 5.58 (18.3) 7.06 (23.2) 8.24 (27.0) 12.0 (39.5) 15.1 (49.5) 20.2 (66.2) 1.48 (4.84) 2.61 (8.56) 3.59 (11.8) 3.89 (12.8) 4.94) (16.2) 5.78 (19.0) 8.49 (27.8) 10.7 (35.1) 14.4 (47.2) 1.17 (3.83) 2.07 (6.78) 2.85 (9.35) 3.09 (10.2) 3.94 (12.9) 4.62 (15.2) 6.8 (22.4) 8.63 (28.3) 11. (38.4)
Average Power Rating, kW Standard conditions: VSWR 1.0; ambient temperature 40 C (104 F); inner conductor temperature 100 C (212 F), except HST Series 200 C (392 F). 150 MHz 450 MHz 824 MHz 960 MHz 1500 MHz 2000 MHz 4000 MHz 6000 MHz 10000 MHz 1.00 0.567 0.412 0.380 0.299 0.256 0.174 0.138 0.102 1.74 0.975 0.704 0.648 0.507 0.431 0.289 0.228 0.166 2.49 1.38 0.991 0.909 0.705 0.597 0.394 0.306 0.220 1.74 0.978 0.706 0.649 0.507 0.431 0.289 0.227 0.165 1.45 0.818 0.592 0.545 0.426 0.363 0.245 0.193 0.141 1.81 1.02 0.736 0.678 0.530 0.451 0.303 0.239 0.175 2.83 1.59 1.15 1.06 0.833 0.710 0.479 0.378 0.691 0.393 0.286 0.264 0.209 0.179 0.123 0.098 0.073 1.18 0.670 0.487 0.449 0.354 0.302 0.206 0.164 0.121 1.46 0.821 0.595 0.549 0.431 0.368 0.249 0.197 0.145
Mechanical Characteristics Diameter over jacket in (mm) Weight lb/ft (kg/m) 0.045 (0.067) 0.078 (0.12) 0.14 (0.21) 0.09 (0.13) 0.06 (0.09) 0.08 (0.12) 0.15 (0.22) 0.063 (0.093) 0.076 (0.113) 0.138 (0.205) 0.29 (7.4) 0.415 (10.5) 0.52 (13.2) 0.45 (11.3) 0.345 (8.8) 0.44 (11.2) 0.63 (15.9) 0.29 (7.37) 0.415 (10.5) 0.518 (13.16)
Min. Bending Radius in (mm) 1 (25) 1 (25) 1.25 (32) 1.75 (45) 3 (76) 3.75 (95) 5 (125) 1 (25) 1 (25) 1.25 (32)
460
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
M17/74 RG-213/U
M17/75 RG-214/U
M17/60 RG-142B/U
M17/127 RG-393/U
M17/2 RG-6/U
M17/6 RG-11/U
78 22000
81 11500
88 10000
65.9 1000
65.9 11000
84
69.5 12400
69.5 11000
65.9 3000
65.9 1000
2.31 (7.57) 4.17 (13.7) 5.83 (19.1) 6.36 (20.9) 8.22 (27.0) 9.73 (31.9) 14.8 (48.6) 19.1 (62.7) 26.7 (87.6)
1.19 (3.89) 2.14 (7.02) 2.99 (9.82) 3.26 (10.7) 4.21 (13.8) 4.98 (16.4) 7.58 (24.9) 9.78 (32.1) 13.6 (44.7)
0.764 (2.51) 1.37 (4.50) 1.91 (6.26) 2.08 (6.81) 2.67 (8.76) 3.15 (10.3) 4.75 (15.6) 6.09 (20.0) 8.42 (27.6)
2.9 (9.5) 5.5 (18.0) 7.8 (25.6) 8.6 (28.2) 11.3 (37.1) 13.6 (44.6) 21.6 (70.9) 28.6 (93.8) 41.4 (136)
1.5 (4.9) 2.8 (9.2) 4.0 (13.1) 4.4 (14.4) 5.8 (19.0) 7.0 (23.0) 11.1 (36.4) 14.7 (48.2)
4.6 (15.1) 8.4 (27.6) 11.8 (38.7) 13.0 (42.7) 16.9 (55.4) 20.2 (66.3) 31.4 (103) 41.1 (135) 58.5 (192)
2.7 (8.8) 4.9 (16.1) 7.0 (23.0) 7.6 (24.9) 10.0 (32.8) 11.9 (39.0) 18.5 (60.7) 24.2 (79.4) 34.5 (113)
3.6 (11.8) 6.7 (22.0) 9.6 (31.5) 10.6 (34.8) 14.0 (45.9) 16.9 (55.4)
0.29 (7.4)
0.52 (13.2)
0.63 (16)
0.405 (10.29)
0.425 (10.79)
0.405 (10.29)
0.195 (4.95)
0.390 (9.91)
0.332 (8.43)
0.405 (10.29)
0.046 (0.068)
0.14 (0.21)
0.14 (0.21)
0.11 (0.164)
0.13 (0.193)
0.089 (0.132)
0.043 (0.064)
0.175 (0.260)
0.082 (0.122)
0.098 (0.146)
1 (25)
1.25 (32)
5 (125)
5 (125)
6 (150)
6 (150)
2 (50)
4 (102)
3 (75)
4.5 (115)
* Braided cables not supplied by Andrew. Listing is for comparative purposes only.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 6/01
461
HELIAX Connectors
462
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Connectors
HELIAX Connectors Offer Multiple Design Advantages
Easy Attachment HELIAX connectors are designed for fast, accurate installation. Features like pre-set pin depths and self-flaring mechanisms ensure performance and reduce costly installation errors. The connectors can be attached with the most basic hand tools. Attachment time can be reduced, even further, with EASIAX cable preparation tools. Each connector is shipped with easy to read instructions to assist with installation. Weatherproof Integrity HELIAX connectors are designed to ensure system integrity in the harshest of outdoor environments. Our connectors are relied on around the world for their ability to withstand heat, humidity, ice, and rain. We design to the toughest environmental standards, such as IP68, to ensure the connectors are waterproof without additional weatherproofing. We test before and after thermal cycling, shock, and vibration testing. We guarantee that, whatever the environment, you can rely on HELIAX connectors. Low Intermodulation HELIAX connectors are designed to keep unwanted intermodulation to a minimum. Andrew is one of a few companies, worldwide, that understands and has the ability to measure intermodulation accurately. Couple this with engineers skilled in minimizing intermodulation and you get connectors with some of the lowest recorded intermodulation levels in the industry. For a more detailed explanation of intermodulation see page 630. Low VSWR HELIAX connectors give you unrivalled VSWR performance. They are designed for a minimum mismatch between cable and connector. This is especially important in today's systems where performance expectations are more stringent. Electrical, mechanical, and environmental testing of all HELIAX connectors ensure lasting performance that can be measured in decades. Data sheets are available on request for all HELIAX connectors. Excellent RF Shielding Outer conductor attachments clamp or solder 360 around the cable resulting in virtually complete shielding. HELIAX connectors for air dielectric cables are not interchangeable with those for foam dielectric cables. HS and HST series cables use corresponding FSJ connectors. Differences include: Air dielectric connectors are equipped with gas ports to allow pressurization of the cable. Most air dielectric connectors are available in both gas barrier and gas pass versions. The gas barrier prevents air flow to the mating connector. Air dielectric cables have a helical corrugated outer conductor. LDF foam cables have annular corrugations and thus use a different clamping nut to secure the connector to the cable. Most air dielectric connectors are attached using a snip flare. LDF foam connectors are self flaring.
463
HELIAX Connectors
1 One iece
TM
With only one piece to the connector, attachment is as easy as sliding the connector on the cable and tightening the back nut. You can be assured that field attachment is consistent and gives you outstanding performance every time! More importantly, the new one-piece connectors also have outstanding electrical characteristics! Completely Waterproof, Mated and Unmated The new one-piece connector is not only waterproof when mated, it is also waterproof when it is unmated and completely submerged in water. This moisture seal provides unparalleled protection from the elements! Exceeds IP66 and IP68 Standards. New Version 2 Connectors for FSJ4-50B The newest connectors for FSJ4-50B have a reduced number of components and incorporate our new crush-flare technology. Installation is fast, reliable, and dependable. EASIAX Plus automated cable prep tools are also available for the new version 2 connectors. New SureFlex Connectors New SureFlex jumper assemblies incorporate a 360 degree solder attachment on both the inner conductor and the outer conductor. Factory made assemblies remove the risks sometimes encountered with assemblies made in the field. Return loss, insertion loss and intermodulation values are optimized with our new SureFlex assemblies. Proven All Andrew components go through a strict qualification process to the toughest Military and International standards before being released. Test procedures are available on the Andrew web site or contact Andrew. In all ways electrically, mechanically, and environmentally you can be sure with Andrew. Value All of the new designs offer price savings as well as outstanding performance.
464
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Connectors
Connector Numbering System
This catalog features a functional, connector type numbering system that installation, purchasing and receiving personnel should find easy to understand. Here are three examples and the functional type number cable, connector, and suffix keys. Type Number: L2PNM L2 denotes it is used with LDF2-50 cable PNM denotes it is a plated N Male Type Number: L4PNF L4 denotes it is used with LDF4-50 cable PNF denotes it is a Plated N Female Type Number: F4PDM-C F4 denotes it is used with FSJ4-50B cable PDM denotes it is a Plated 7-16 DIN Male C denotes it features a captivated pin
Cable Keys E2 F1 F2 F4 H4 H4.5 H5 H7 H8 H11 H9 H9HP H12 L1 L2 L4 L4.5 L5 L6 L7 L12 V5 V6 V7 Connector Keys PNM PNR PNF PBM PSM PSF PSR PDM Plated N Male Plated N Male Right Angle Plated N Female Plated BNC Male Plated SMA Male Plated SMA Female Plated SMA Male Right Angle Plated 7-16 DIN Male EFX2-50 FSJ1-50A FSJ2-50 FSJ4-50B HJ4-50 HJ4.5-50 HJ5-50 HJ7-50A HJ8-50B HJ11-50 HJ9-50 HJ9HP-50 HJ12-50 LDF1-50 LDF2-50 LDF4-50A LDF4.5-50 LDF5-50A LDF6-50 LDF7-50A LDF12-50 VXL5-50 VXL6-50 VXL7-50 3/8" 1/4" 3/8" 1/2" 1/2" 5/8" 7/8" 1-5/8" 3" 4" 5" 5" (High Power) 2-1/4" 1/4" 3/8" 1/2" 5/8" 7/8" 1-1/4" 1-5/8" 2-1/4" 7/8" 1-1/4" 1-5/8" Connector Keys (Continued) PDF PDR PKM PKR PTM PTF SM SF UM UF MU FM M F Suffix Keys HF BH 7550 7570 C PM PMC H BHC PMC T HC PR RC RPC B P High Frequency Bulkhead 75-Ohm Cable, 50-Ohm Mating Pin 75-Ohm Cable, 70-Ohm Mating Pin Captivated Pin Inner Attachment (solderless) Panel Mount Panel Mount, Captivated Pin Hex Coupling Nut Bulkhead, Captivated Pin Panel Mount, Captivated Pin Tunable Hex Coupling Nut, Captivated Pin Inner Contact Attachment Pressure Port Ring Flare, Captivated Pin Inner contact Attachment One-Piece Connector, Captivated Pin Gas Barrier Gas Pass Plated 7-16 DIN Female Plated 7-16 DIN Male Right Angle Plated 4.1-9.5 DIN Male Plated 4.1-9.5 DIN Male Right Angle Plated TNC Male Plated TNC Female SMA Male SMA Female UHF Male UHF Female Mini UHF Male CATV F Male EIA Flange Male EIA Flange Female
Connector Data
Coupling Torque for All Type N and 7-16 DIN Connectors Type N lbf-in (Nm) 15-20 (1.7-2.3) 7-16 DIN lbf-in (Nm) 220-265 (25-30)
Pin Depth for Type N and 7-16 DIN Connectors Connector N Male N Female 7-16 DIN Male 7-16 DIN Female Pin Depth, in (mm)* 0.210-0.230 (5.28-5.84) 0.187-0.207 (4.75-5.26) 0.058-0.070 (1.47-1.78) 0.070-0.082 (1.78-2.08)
* High frequency performance may be enhanced by adjusting pin depth to minimize the gap between male and female connectors.
465
HELIAX Connectors
The pictures below and on pages 467-470 show the various connector interfaces and body styles available for HELIAX cables. In many cases, a single picture is used to represent several similar connectors. See the connector ordering information charts for details.
N Males
Bulkhead N Females
N Females
UHF Males
466
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Connectors
UHF Females
SMA Males
SMA Females
467
HELIAX Connectors
SC Male LC Males
BNC Male
TNC Males
LC Females
TNC Females
HN Males
468
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Connectors
7/8" EIA Flanges
Female For LDF6, LDF7 Cables For HJ12, HJ8, HJ11, LDF12 Cables
469
HELIAX Connectors
4-1/2" IEC Flanges F Flanges, Male
Splices
End Terminals
470
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX Accessories
Andrew offers the industry's widest range of accessories, which are designed to be compatible with HELIAX cable. Together, HELIAX cables and accessories form a lasting and effective transmission line system. System designers and installation crews can rely on Andrew for high quality, easy to install components and reliable maintenance-free performance.
All versions incorporate silver plated components and highpressure components throughout to ensure low levels of intermodulation and excellent VSWR performance. Arrestor Plus surge protectors are also fully weatherproof, making them suitable for a variety of outdoor applications. Grounding Kits. All Andrew grounding kits are designed to withstand 99% of all possible lightning strikes for certainty of continued operation. The non-braided, solid copper construction of our grounding kits eliminates corrosion caused by moisture retention and wicking. The new SureGround kits offer even greater installation ease than standard grounding kits. The new grounding kits are factory assembled into one component and feature a pre-formed, clip-on ground strap for easy snap-on installation. A standard weatherproofing kit (tape) is provided with SureGround versions and a weatherproofing boot is supplied with the SureGround Plus versions.
471
Entry Port Systems. Andrew offers entry port systems to meet your every need. The ArrestorPort II integrates your cable entry and grounding systems into a single integrated system and cuts installation time and component costs. It is designed to work with the Arrestor Plus Surge Protectors. The new, low cost, SNAP-IN Entry port quickly and easily snaps into a hole in a cabinet or metal plate. It's used in combination with our one-piece entry boot to adapt to your requirements. For traditional installations consider our standard entry port products. Hangers. Stainless steel construction of both the standard and our new Snap-in hangers ensures corrosion resistance and long life. The new Snap-In hangers feature an ergonomic design that provides easy attachment with no hardware required. Our Click-On hanger products are stackable and install in minutes to provide a perfect fit for applications where space is tight. Click-On hangers are manufactured from tough, UV-resistant material and set the standard for durability, simplicity, and cost effectiveness. Weatherproofing. The WeatherShield Connection Protection Housing provides you with security against water. WeatherShield easily installs in seconds, to
complete your transmission line system and protect against the environment. WeatherShield provides an additional measure of system protection by providing a water-tight seal around the cable and dampening the vibration that can loosen connector interfaces. The WeatherShield takes just seconds to install. Simply place the WeatherShield around your connection and snap in place. No tapes, heat guns or shrink tubes are required. EASIAX Plus Cable Preparation Tools. Our EASIAX Plus Cable Prep tools provide you with all you need to install HELIAX connectors on HELIAX Cable. EASIAX Plus automated tools dramatically reduce cable preparation time and expense while improving overall system performance. Fit the EASIAX Plus tool to any standard drill and the tool does the rest. You will be able to fit your connector in about 15 seconds and your connector attachments will be consistent, reliable, and repeatable. For greatest accuracy, when installing connectors, we recommend that you use our pre-set torque wrenches. This will ensure the high quality protection and performance that you expect from Andrew.
472
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HELIAX coaxial cables are available with connectors attached at one or both ends or with both connectors unattached.
Ordering Information
3. Specify connector Type Numbers and attached or unattached. When attached connectors on an assembly are different, specify which is first off the reel. 4. Specify any special requirements: Special marking on packages Packaging requirements (standard, export or special) Special inspection requirements, such as customer, government, certificate of compliance 5. Specify mode of shipment (surface, air or ocean) and requested ship date. Sample orders are illustrated below.
Sample Orders
Andrew Type Number Description HELIAX Coaxial Cable Assembly 1850 -1990 MHz L5PDM L5PNM Connector, attached, first off Connector, attached, last off 1 1 Frequency (where) applicable) Quantity 1 Length Each 290 ft Total Length 290 ft Unit or Per Foot Extended Price Price
LDF5P-50A-18
HELIAX Coaxial Cable Connector, unattached HELIAX Coaxial Cable Connector, attached, first off Connector, unattached
2 8 1 1 1
700 ft
1400 ft
310 ft
310 ft
EWP52-59
Elliptical Waveguide 5.925 - 6.425 GHz Connector, attached, first off Connector, attached, last off Elliptical Waveguide 5.925 - 6.425 GHz Connector, unattached Elliptical Waveguide 5.925 - 6.425 GHz Connector, attached, first off Connector, unattached
1 1 1 2 8 1 1 1
290 ft
290 ft
Elliptical Waveguide Factory Assembly Bulk Elliptical Waveguide and Connectors Elliptical Waveguide with One Attached Connector
700 ft
1400 ft
310 ft
310 ft
*For cables and waveguides, specify whether connectors should be factory attached or shipped loose. When attached connectors on an assembly are different, specify which is first off the reel. For microwave antennas, specify any desired options.
Special marking on packages: Packing requirements: Special (specify)
Standard
Export
Ship by:
Surface
Air
Ocean
Requested Carrier (If none specified, we will use the most economical method) Shipping charges: Collect
X Yes
Sales: Resale no.
No
Partials OK?
X Yes
Not Applicable
No
Applicable
Quoted fixed freight amount Specify special inspection requirements, such as customer, government, certificate of compliance.
473
FSJ1-50A
Description Type No.
FSJ1-50A
FSJ1RN-50B FSJ1RN-50B
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, standard jacket, in (mm) Diameter over Jacket, fire-retardant jacket, in (mm) Diameter Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) Copper Cu-Clad Al 0.29 (7.4) 0.29 (7.4) 0.25 (6.4) 0.075 (1.9) 1 (25) 15 (20) 0.8 (1.1) 0.045 (0.067) 150 (68) 100 (1.8) 50 1 20.4 84 6.4 3.0 (9.8) 2.0 (6.5) 1600 5000 24.2 (79.4) 0.061 (0.200)
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
474
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male F1PNMV2-H
Connectors
Interface N Male N Male N Male N Female N Female BNC Male UHF Male UHF Female SMA Male SMA Male SMA Female SMA Male TNC Male TNC Female TNC Male Mini-UHF Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female Description Hex Head High Freq. Right Angle Hex Head Bulkhead Type Number F1PNMV2-H F1PNM-HF F1PNR-HC F1PNF F1PNF-BH F1PBM 41SP 41U F1PSM F1PSR F1PSF 41EWS F1PTM 41AENT F1PTM-HF F1MU F1PDM F1PDF F1PDF-PM F1PDF-BH Inner Contact Attachment Solder Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Captivated Captivated Captivated Solder Solder Solder Solder Outer Contact Attachment Self-Clamping Tab Flare Self-Clamping Self-Clamping Self-Clamping Self-Clamping Solder Solder Self-Clamping Self-Clamping Self-Clamping Tab Flare Self-Clamping Tab Flare Tab Flare Crimp Self-Clamping Self-Clamping Self-Clamping Self Clamping Plating Code SG SG SG SG SG SS BB BS PG PG PG G SG NG NG NS SS SS SS SS Max. Length in (mm) 2.1 (53) 1.3 (33) 1.7/1.3 (43/33) 2.2 (55.2) 2.3 (58) 2.0 (50) 1.8 (46) 2.1 (53) 1.7 (43) 1.6/0.75 (41/19) 1.7 (43) 0.94 (23.9) 1.68 (43) 1.5 (38) 1.9 (48.8) 1.53 (39) 1.82 (46.3) 1.85 (47) 1.85 (47) 1.85 (47) Max. Dia. in (mm) 0.95 (24.1) 0.81 (20.5) 0.95 (24.1) 0.58 (14.8) 0.94 (23.9) 0.69 (17.5) 0.77 (19.6) 0.77 (19.6) 0.49 (12.5) 0.50 (12.7) 0.49 (12.5) 0.40 (10.2) 0.57 (14.5) 0.70 (17.8) 0.70 (17.8) 0.47 (11.9) 1.25 (31.75) 0.551 (14) 1.26 (32) 1.62 (41)
Up to 6 GHz Right Angle Up to 6 GHz, Bulkhead Up to 18 GHz 11 GHz and Below Bulkhead Hi Freq, Above 11 GHz
* Stainless steel body Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, NS- Nickel Plated Body and Silver Plated Pin, PG - Passivated Body and Gold Plated Pin+A135, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, G - Stainless Steel Body and Gold Plated Pin.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 12/00 & 5/01
475
0.01- 4.2*
FSJ1P-50A-2A
0.01-10.2*
FSJ1P-50A-3A
0.01-18.0*
FSJ1P-50A-4A
* Specify frequency band. ** Connectors ordered separately. VSWR values apply to straight connectors only (except where noted otherwise), are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed. High frequency version.
Accessories
Description Type No. Description Type No.
476
Revised 9/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1/4" Superflexible High Power, High Temperature, Plenum, Fluoropolymer Foam Dielectric, ETS Series 50-ohm
ETS1-50T
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (pf/m) Inductance, H/ft (H/m) Mechanical Outer Conductor Copper Inner Conductor Silver plated copper Diameter over Jacket, in (mm) 0.29 (7.4) Diameter over Copper Outer Conductor, in (mm) 0.25 (6.4) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum (typical) 15 (20) Bending Moment, lb-ft (Nm) 0.6 (0.8) Cable Weight, lb/ft (kg/m) 0.066 (0.098) Tensile Strength, lb (kg) 150 (68) Flat Plate Crush Strength, lb/in (kg/mm) 100 (1.8) 50 2 20.0 82 6.4 1.9 (6.2) 2.0 (6.5) 1600 4000 24.6 (80.6) 0.063 (0.205)
0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 14000 16000 18000 19000 20000
Standard Conditions: For Attenuation: VSWR 1.0, ambient temperature 20C (68F). 1. For Average Power, Type ETS1-50T (jacketed): VSWR 1.0 ambient temperature 40C (104F), inner conductor temperature 200C (392F). 2. For Average Power, Type ETS1-50 (unjacketed): VSWR 1.0 ambient temperature 40C (104F), inner conductor temperature 250C (482F); no solar loading.
477
N Male F1PNMV2-H
Connectors
Interface N Male N Male N Male N Female N Female BNC Male UHF Male UHF Female SMA Male SMA Male SMA Female SMA Male SMA Female TNC Male TNC Female TNC Male Mini-UHF Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female Description Hex Head High Freq. Hex Head Right Angle Bulkhead Type Number F1PNMV2-H F1PNM-HF F1PNR-HC F1PNF F1PNF-BH F1PBM 41SP 41U F1PSM F1PSR F1PSF 41EWS 41ENS F1PTM 41AENT F1PTM-HF F1MU F1PDM F1PDF F1PDF-PM F1PDF-BH Inner Contact Attachment Solder Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Captivated Captivated Captivated Solder Solder Solder Solder Outer Contact Attachment Self-Clamping Tab Flare Self-Clamping Self-Flare Self-Clamping Self-Clamping Solder Solder Self-Clamping Self-Clamping Self-Clamping Tab Flare Tab Flare Self-Clamping Tab Flare Tab Flare Crimp Self-Clamping Self-Clamping Self-Clamping Self Clamping Plating Code SG SG SG SG SG SS BB BS PG PG PG G G SG NG NG NS SS SS SS SS Max. Length in (mm) 2.1 (53) 1.3 (33) 1.7/1.3 (43/33) 2.2 (55.2) 2.3 (58) 2.0 (50) 1.8 (46) 2.1 (53) 1.7 (43) 1.6/0.75 (41/19) 1.7 (43) 0.94 (23.9) 1.00 (25.4) 1.68 (43) 1.5 (38) 1.9 (48.8) 1.53 (39) 1.82 (46.3) 1.85 (47) 1.85 (47) 1.85 (47) Max. Dia. in (mm) 0.95 (24.1) 0.81 (20.5) 0.95 (24.1) 0.58 (14.8) 0.94 (23.9) 0.69 (17.5) 0.77 (19.6) 0.77 (19.6) 0.49 (12.5) 0.50 (12.7) 0.49 (12.5) 0.40 (10.2) 0.40 (10.2) 0.57 (14.5) 0.70 (17.8) 0.70 (17.8) 0.47 (11.9) 1.25 (31.75) 0.551 (14) 1.26 (32) 1.62 (41)
Up to 6 GHz Right Angle Up to 6 GHz, Bulkhead Up to 18 GHz Up to 18 GHz 11 GHz and Below Bulkhead Hi Freq, Above 11 GHz
* Stainless steel body Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, NS- Nickel Plated Body and Silver Plated Pin, PG - Passivated Body and Gold Plated Pin+A135, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, G - Stainless Steel Body and Gold Plated Pin.
Connector Accessories See page 624. Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
478
Revised 7/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
CT-K350
479
FSJ2-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 13400 Attenuation dB/100 ft 0.082 0.117 0.143 0.165 0.372 0.528 0.649 0.842 1.13 1.20 1.25 1.48 1.60 1.72 2.13 2.48 2.64 2.79 2.83 3.08 3.35 3.60 3.66 3.82 3.97 4.06 4.59 5.08 5.45 5.63 5.97 6.14 6.30 6.47 7.53 8.09 8.90 10.2 11.3 13.5 15.5 17.4 18.6 Attenuation dB/100 m 0.270 0.383 0.469 0.542 1.22 1.73 2.13 2.76 3.69 3.94 4.10 4.86 5.25 5.65 6.99 8.14 8.66 9.17 9.28 10.1 11.0 11.8 12.0 12.5 13.0 13.3 15.1 16.7 17.9 18.5 19.6 20.1 20.7 21.2 24.7 26.6 29.2 33.3 37.2 44.3 50.8 57.0 61.1 Average Power, kW 13.2 13.2 13.2 13.2 6.92 4.87 3.97 3.06 2.29 2.14 2.06 1.74 1.61 1.49 1.21 1.04 0.975 0.921 0.910 0.836 0.769 0.715 0.704 0.673 0.648 0.634 0.580 0.507 0.472 0.457 0.431 0.419 0.409 0.398 0.342 0.318 0.289 0.254 0.228 0.191 0.166 0.148 0.138
FSJ2-50
FSJ2RN-50 FSJ2RN-50
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, standard jacket, in (mm) 0.415 (10.5) Diameter over Jacket, fire-retardant jacket, in (mm) 0.425 (10.8) Diameter over Copper Outer Conductor, in (mm) 0.375 (9.5) Diameter Inner Conductor, in (mm) 0.110 (2.8) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum (typical) 20 (50) Bending Moment, lb-ft (Nm) 1.7 (2.3) Cable Weight, lb/ft. (kg/m) 0.078 (0.12) Tensile Strength, lb (kg) 210 (95) Flat Plate Crush Strength, lb/in (kg/mm) 100 (1.8) 50 1 13.4 83 13.2 1.29 (4.23) 1.52 (4.99) 2300 5000 24.3 (79.7) 0.061 (0.200)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
480
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male F2PNM-H
N Female F2PNF
Connectors
Interface N Male N Male N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Male Description Hex Head Hex Head Type Number F2PNM-H F2PNM-HC F2PNF F2PNF-C F2PNF-BH F2PDM F2PDM-C F2PDF F2PDF-C F2PDF-PM F2PDR-C Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Captivated Solder Captivated Solder Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SS SS SS SS SS SS Max. Length in (mm) 1.9 (48) 1.9 (48) 2.1 (53) 2.1 (53) 2.1 (53) 2.2 (57) 2.1 (53) 2.2 (56) 2.1 (51.6) 2.2 (56) 1.7/1.3 (43/34) Max. Dia. in (mm) 0.94 (23) 0.94 (23) 0.67 (17) 0.64 (16) 0.95 (24) 1.4 (36) 1.4 (36) 1.1 (28) 0.79 (20) 1.1 (28) 1.4 (36)
Bulkhead
Plating Codes: SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, BS - Brass Body and Silver Plated Pin.
* Specify operating band. ** Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 3/01
481
Accessories
Description Type No. Description Type No.
CT-K350
482
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
3/8" Superflexible High Power, High Temperature, Expanded PTFE Foam Dielectric, ETS Series 50-ohm
ETS2-50T
Description Type No.
Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 13400
Attenuation dB/100 ft 0.083 0.117 0.143 0.166 0.373 0.531 0.653 0.849 1.14 1.22 1.27 1.51 1.63 1.75 2.18 2.54 2.71 2.87 2.91 3.17 3.45 3.72 3.78 3.96 4.12 4.22 4.78 5.31 5.71 5.90 6.28 6.46 6.64 6.81 7.98 8.61 9.50 10.9 12.2 14.7 17.0 19.2 20.7
Attenuation dB/100 m 0.271 0.383 0.470 0.543 1.22 1.74 2.14 2.79 3.73 3.99 4.16 4.94 5.34 5.75 7.14 8.34 8.89 9.41 9.54 10.4 11.3 12.2 12.4 13.0 13.5 13.8 15.7 17.4 18.7 19.4 20.6 21.2 21.8 22.4 26.2 28.2 31.2 35.8 40.1 48.2 55.8 62.9 67.8
ETS2-50T1 ETS2-502 Avg. Power Avg. Power kW kW 13.2 13.2 13.2 13.2 13.2 12.2 9.89 7.61 5.68 5.31 5.10 4.29 3.97 3.69 2.97 2.54 2.39 2.25 2.22 2.04 1.87 1.74 1.71 1.63 1.57 1.53 1.35 1.22 1.13 1.10 1.03 1.00 0.975 0.950 0.811 0.752 0.681 0.593 0.529 0.441 0.381 0.338 0.314 13.2 13.2 13.2 13.2 13.2 13.2 11.3 8.67 6.47 6.05 5.82 4.89 4.52 4.20 3.39 2.90 2.72 2.57 2.53 2.32 2.13 1.98 1.95 1.86 1.79 1.75 1.54 1.39 1.29 1.25 1.17 1.14 1.11 1.08 0.924 0.847 0.776 0.676 0.603 0.502 0.434 0.385 0.358
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Silver Plated, Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.415 (10.5) Diameter over Copper Outer Conductor, in (mm) 0.375 (9.5) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum (typical) 20 (50) Bending Moment, lb-ft (Nm) 1.7 (2.3) Cable Weight, lb/ft. (kg/m) 0.087 (0.13) Tensile Strength, lb (kg) 210 (95) Flat Plate Crush Strength, lb/in (kg/mm) 100 (1.8) 50 2 13.4 83 13.2 1.29 (4.23) 1.52 (4.99) 2300 4000 24.3 (79.7) 0.061 (0.200)
Standard Conditions: For Attenuation: VSWR 1.0, ambient temperature 20C (68F). 1. For Average Power, Type ETS2-50T (jacketed): VSWR 1.0 ambient temperature 40C (104F), inner conductor temperature 200C (392F). 2. For Average Power, Type ETS2-50 (unjacketed): VSWR 1.0 ambient temperature 40C (104F), inner conductor temperature 250C (482F); no solar loading.
483
N Male F2PNM-H
N Female F2PNF
Connectors
Interface N Male N Male N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Male Description Hex Head Hex Head Type Number F2PNM-H F2PNM-HC F2PNF F2PNF-C F2PNF-BH F2PDM F2PDM-C F2PDF F2PDF-C F2PDF-PM F2PDR-C Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Captivated Solder Captivated Solder Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SS SS SS SS SS SS Max. Length in (mm) 1.9 (48) 1.9 (48) 2.1 (53) 2.1 (53) 2.1 (53) 2.2 (57) 2.1 (53) 2.2 (56) 2.1 (51.6) 2.2 (56) 1.7/1.3 (43/34) Max. Dia. in (mm) 0.94 (23) 0.94 (23) 0.67 (17) 0.64 (16) 0.95 (24) 1.4 (36) 1.4 (36) 1.1 (28) 0.79 (20) 1.1 (28) 1.4 (36)
Bulkhead
Plating Codes: SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, BS - Brass Body and Silver Plated Pin.
Accessories
Description Type No. Description Type No.
CT-K350
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
484
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
FSJ4-50B
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 10200 Attenuation dB/100 ft 0.070 0.100 0.122 0.141 0.318 0.453 0.557 0.724 0.971 1.04 1.08 1.28 1.39 1.50 1.86 2.17 2.31 2.45 2.48 2.71 2.95 3.18 3.23 3.38 3.52 3.60 4.09 4.54 4.88 5.05 5.37 5.53 5.68 5.83 6.84 7.38 8.15 9.35 10.5 12.6 14.6 14.8 Attenuation dB/100 m 0.231 0.327 0.401 0.463 1.04 1.49 1.83 2.38 3.19 3.41 3.55 4.21 4.56 4.91 6.09 7.12 7.59 8.04 8.15 8.89 9.68 10.4 10.6 11.1 11.6 11.8 13.4 14.9 16.0 16.6 17.6 18.1 18.6 19.1 22.4 24.2 26.7 30.7 34.4 41.4 47.9 48.5 Average Power, kW 15.6 15.6 15.6 15.6 10.1 7.07 5.75 4.42 3.30 3.08 2.96 2.49 2.30 2.14 1.72 1.48 1.38 1.31 1.29 1.18 1.09 1.01 0.991 0.947 0.909 0.889 0.783 0.705 0.656 0.634 0.597 0.580 0.564 0.549 0.469 0.435 0.394 0.343 0.306 0.254 0.220 0.217
FSJ4-50B
FSJ4RN-50B FSJ4RN-50B
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, standard jacket, in (mm) 0.52 (13.2) Diameter over Jacket, fire-retardant jacket, in (mm) 0.53 (13.5) Diameter over Copper Outer Conductor, in (mm) 0.48 (12.2) Diameter Inner Conductor, in (mm) 0.142 (3.6) Minimum Bending Radius, in (mm) 1.25 (32) Number of Bends, minimum (typical) 20 (50) Bending Moment, lb-ft (Nm) 2.0 (2.7) Cable Weight, lb/ft. (kg/m) 0.14 (0.21) Tensile Strength, lb (kg) 175 (80) Flat Plate Crush Strength, lb/in (kg/mm) 110 (1.9) 50 1 10.2 81 15.6 0.82 (2.69) 1.00 (3.28) 2500 5000 25.2 (82.7) 0.0625 (0.205)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
485
N Male F4PNMV2-H
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female 4.1/9.5 DIN Male 4.1/9.5 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange UHF Male UHF Female HN Male SC Male Description Hex Head Hex Head Rt Angle, Hex Hd Bulkhead Rt Angle, Outdoor Use Right Angle Right Angle Bulkhead Panel Mount Bulkhead Panel Mount Type Number F4PNMV2-H F4PNMV2-HC F4PNR-H F4PNR-HC F4PNF F4PNF-C F4PNF-BH F4PKM-C F4PKR-C F4PDMV2-C F4PDMV2 F4PDR F4PDR-C F4PDF-C F4PDF F4PDF-BH F4PDF-PM F4PDF-BHC F4PDF-PMC 44ASR 44ASP 44ASU 44ASJ 44SPCW Inner Contact Attachment Solder Captivated Solder Captivated Solder Captivated Solder Captivated Captivated Captivated Solder Solder Captivated Captivated Solder Solder Solder Captivated Captivated Solder Solder Solder Solder Solder Outer Contact Attachment Crush-Flare Crush-Flare Tab-Flare Crush-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Crush Flare Crush Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Plating Code SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS SS SS SS BS BS BS BB SG Max. Length in (mm) 2.13 (54.0) 2.13 (54.0) 3.3/1.5 (84/38) 2.8 (71.9)/1.6 (41.5) 2.3 (53.3) 2.3 (53.3) 2.3 (58) 2.0 (50) 2.3/1.5 (57/38) 1.98 (50.2) 2.10 (53.4) 2.4.1.8 (61/46) 2.1/2.0 (53/50) 2.0 (50) 2.0 (50) 2.01 (51.1) 2.01 (51.1) 2.0 (50) 2.0 (50) 3.3 (84) 2.1 (53) 2.3 (58) 2.4 (61) 2.7 (69) Max. Dia. in (mm) 0.94 (23.8) 0.94 (23.8) 0.86 (21.8) 1 (25.7) 0.88 (22.4) 0.88 (22.4) 0.95 (24.1) 0.95 (24.1) 0.95 (24.1) 1.05 (26.7) 1.05 (26.7) 1.4 (35.6) 1.4 (35.6) 1.1 (27.9) 1.1 (27.9) 1.50 (38) 1.26 (32) 1.8 (45.7) 1.3 (33) 1.4 (35.6) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.88 (22.4)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
486
Revised 7/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
0.01-4.2*
FSJ4P-50B-2
0.01-7.1*
FSJ4P-50B-3
1.7-2.7
FSJ4P-50B-7
4.0-8.0*
FSJ4P-50B-8
* Specify operating band. ** Connectors ordered separately. VSWR values apply to straight connectors only (except where noted otherwise), are guaranteed for factory fit assemblies and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 9/00 & 3/01
487
Accessories
Description Type No. Description Type No.
488
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
EFX2-50
Description Type No.
EFX2-50
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.45 (11.3) Diameter over Copper Outer Conductor, in (mm) 0.38 (9.7) Minimum Bending Radius, in (mm) 1.75 (45) Number of Bends, minimum (typical) 15 Bending Moment, lb-ft (Nm) 1.7 (2.3) Cable Weight, lb/ft (kg/m) 0.09 (0.13) Tensile Strength, lb (kg) 175 (79) Flat Plate Crush Strength, lb/in (kg/mm) 120 (2.1) U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 50 1 13.5 85 15.6 1.1 (3.6) 0.92 (3.0) 2500 5000 24.1 (79.0) 0.06 (0.20)
0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 13500
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
489
E2PNM-H N Male
Connectors
Interface N Male N Male N Male N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female TNC Male TNC Female UHF Male UHF Female SMA Male Description Hex Head Right Angle Bulkhead Right Angle Type Number E2PNM-H E2PNM-HC E2PNR-HC E2PNF-C E2PNF E2PNF-BH E2PDM-C E2PDR-C E2PDF-C E2PTM E2PTF E2UM E2UF E2SM Inner Contact Attachment Solder Captivated Captivated Captivated Solder Solder Captivated Captivated Captivated Solder Solder Solder Solder Solder Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SG SS SS SS SG NG BB BS BG Max. Length in (mm) 2.0 (52) 2.16 (54.8)/0.89 (17.6) 2.4/1.5 (60.4/37.7) 2.4 (61) 2.5 (63.7) 2.1 (53) 2.9 (74.4)/45.5 (1.8) 2.1 (53) 2.2 (56) 1.9 (49) 2.2 (56) 2.1 (53) 2.2 (56) Max. Dia. in (mm) 0.94 (23.9) 0.89 (17.6) 0.91 (23.1) 0.69 (17.6) 0.86 (21.4) 1.41 (35.9) 1.4 (35.9) 1.10 (27.9) 0.63 (16.1) 0.63 (16.1) 0.77 (19.6) 0.68 (17.3) 0.68 (17.3)
Plating Codes: BG - Brass Body and Gold Plated Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, SG - SIlver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
**Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
490
Revised 9/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
LDF1-50
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.345 (8.8) Diameter over Copper Outer Conductor, in (mm) 0.31 (7.7) Diameter Inner Conductor, in (mm) 0.102 (2.6) Minimum Bending Radius, in (mm) 3.0 (76) Number of Bends, minimum (typical) 15 (30) Bending Moment, lb-ft (Nm) 0.98 (1.33) Cable Weight, lb/ft (kg/m) 0.06 (0.09) Tensile Strength, lb (kg) 200 (91) Flat Plate Crush Strength, lb/in (kg/mm) 80 (1.4) 50 1 15.8 86 12.1 1.57 (5.15) 1.02 (3.33) 2200 5000 23.4 (76.8) 0.059 (0.19)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
491
N Male L1PNR-HC
N Male L1PNM-H
N Female L1PNF
Connectors
Interface N Male N Male N Male N Female N Female N Female Description Hex Head Hex Head Right Angle Bulkhead Type Number L1PNM-H L1PNM-HC L1PNR-HC L1PNF L1PNF-C L1PNF-BH Inner Contact Attachment Solder Captivated Captivated Solder Captivated Solder Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SS SG SG SG SG Max. Length in (mm) 1.9 (49) 2 (52) 2.3/1.3 (58.3/32.7) 2.1 (52) 2.1 (52) Max. Dia. in (mm) 0.94 (23.9) 0.89 (17.6) 0.91 (23.1) 0.62 (15.7) 0.88 (22.4)
**Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Connector Accessories See page 624 Tools for additional tool offerings see pages 620-623 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
EASIAX Plus Automated Cable Prep Tool DIN Connector Coupling Torque Wrench N Connector Coupling Torque Wrench CPT-L1 244377 244379
492
Revised 7/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
LDF2-50
Description Type No.
LDF2-50
LDF2RN-50 LDF2RN-50
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.44 (11) Diameter over Copper Outer Conductor, in (mm) 0.38 (9.7) Diameter Inner Conductor, in (mm) 0.122 (3.1) Minimum Bending Radius, in (mm) 3.75 (95) Number of Bends, minimum (typical) 15 (60) Bending Moment, lb-ft (Nm) 1.4 (1.9) Cable Weight, lb/ft (kg/m) 0.08 (0.12) Tensile Strength, lb (kg) 250 (113) Flat Plate Crush Strength, lb/in (kg/mm) 110 (2.0) 50 1 13.5 88 15.6 1.06 (3.48) 0.87 (2.85) 2500 5000 23.0 (75.5) 0.058 (0.19)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
493
N Male L2PNM-H
N Female L2PNF
Connectors
Interface N Male N Male N Female N Female 4.1/9.5 DIN 4.1/9.5 DIN 4.1/9.5 DIN 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female UHF Male UHF Female SMA Male TNC Male TNC Female Description Hex Head Hex Head Bulk Head Right Angle Panel Mount Type Number L2PNM-H L2PNM-HC L2PNF L2PNF-BH L2PKM-C L2PKM L2PKR-C L2PDM-C L2PDF-C L2PDF-PMC L42P L42U L42WS L42EWT L42ENT Inner Contact Attachment Solder Captivated Solder Solder Captivated Solder Captivated Captivated Captivated Captivated Solder Solder Solder Solder Solder Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SS SS SS SS SS SS BB BB BG NG NG Max. Length in (mm) 2.1 (53) 2.1 (53) 2.4 (61) 2.4 (61) 1.9 (48) 1.9 (48) 2.0/1.5 (50/38) 1.9 (48) 1.9 (48) 1.9 (48) 2.3 (58) 2.3 (58) 2.2 (56) 2.1 (53) 1.9 (48) Max. Dia. in (mm) 0.94 (23.9) 0.94 (23.9) 0.63 (16.0) 0.88 (22.4) 0.95 (24.1) 0.95 (24.1) 0.95 (24.1) 1.1 (27.9) 1.4 (35.6) 1.25 (31.8) 0.68 (17.3) 0.91 (23.1) 0.68 (17.3) 0.68 (17.3) 0.68 (17.3)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, SG - SIlver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
494
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
* Specify operating band. ** Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 3/01
495
LDF4-50A
Description Type No.
LDF4-50A
LDF4RN-50A LDF4RN-50A
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.63 (16) Diameter over Copper Outer Conductor, in (mm) 0.55 (14) Diameter Inner Conductor, in (mm) 0.189 (4.6) Nominal Inside Transverse Dimensions, cm 1.11 Minimum Bending Radius, in (mm) 5 (125) Number of Bends, minimum (typical) 15 (50) Bending Moment, lb-ft (Nm) 2.8 (3.8) Cable Weight, lb/ft (kg/m) 0.15 (0.22) Tensile Strength, lb (kg) 250 (113) Flat Plate Crush Strength, lb/in (kg/mm) 110 (2.0) 50 1 8.8 88 40 0.45 (1.48) 0.58 (1.90) 4000 8000 23.1 (75.8) 0.058 (0.19)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
496
Revised 9/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L4PNM-RC
N Female L4PNF-RC
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange 7/8" EIA Flange F Flange Male F Flange Female UHF Male UHF Female HN Male LC Male TNC Female End Terminal Splice Description Hex Head RingFlare Right Angle, Hex Right Angle, Hex Bulk Head Panel Mount RingFlare Right Angle Right Angle RingFlare Bulk Head Bulk Head Panel Mount RingFlare Right Angle Type Number L4PNM-H L4PNM-RC L4PNR-H L4PNR-HC L4PNF L4PNF-BH L4PNF-PM L4PNF-RC L4PDM L4PDR L4PDR-C L4PDM-RC L4PDF L4PDF-BH L4PDF-BHC L4PDF-PM L4PDF-RC L44R 124990-1 L44F 209865 L44P L44U L44J L44M L44NT L44T L44Z Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Solder Captivated Solder Solder Captivated Captivated Solder Solder Captivated Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Outer Contact Attachment Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Ring-Flare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS BB BB BB BS BB BS BB BB BB BB BB Max. Length in (mm) 2.6 (66) 3.0 (75.7) 3.2/1.5 (81/38) 3.2/1.5 (81/38) 2.6 (66) 2.6 (66) 2.6 (66) 2.8 (71) 2.6 (66) 1.8/2.8 (46/72) 1.8/2.8 (46/72) 2.64 (67.1) 2.7 (69) 2.73 (69.4) 2.9 (74) 2.7 (69) 2.8 (71) 3.2 (81) 2.3/1.6 (58/41) 2.3 (58) 2.3 (58) 2.3 (58) 2.3 (58) 2.5 (64) 3.6 (91) 2.8 (71) 4.0 (102) 3.2 (81) Max. Dia. in (mm) 0.95 (24.1) 0.86 (21.8) 0.95 (24.1) 0.91 (23.1) 0.94 (23.9) 0.96 (24.4) 1.0 (25.4) 0.86 (21.8) 1.4 (35.6) 1.41 (35.9) 1.41 (35.9) 0.86 (21.8) 1.1 (27.9) 1.62 (41.1) 1.63 (41.4) 1.2 (29.4) 0.86 (21.8) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.94 (23.9) 0.91 (23.1) 1.1 (27.9)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
497
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
1.6-2.3
LDF4P-50A-10
1.7-2.2 0.940-2.7
LDF4P-50A-41 LDF4P-50A-3
0.01-0.806
LDF4P-50A-6
0.01-2.7*
LDF4P-50A-7
3.6-6.5*
LDF4P-50A-5
0.1-4.2*
LDF4P-50A-8
0.1-8.4*
LDF4P-50A-9
* Specify operating band. ** Connectors ordered separately. VSWR values apply to straight connectors only (except when noted otherwise), are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
498
Revised 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
SureGround Plus Grounding Kit with weatherproofing boot Factory attached one-hole lug, 600 mm (24") lead Factory attached two-hole lug, 600 mm (24") lead Field attached two-hole lug, 1500 mm (59") lead SGPL4-06B1 SGPL4-06B2 SGPL4-15B4
Snap-In Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-1 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L4SGRIP L4SGRIP-4IK 43094 L4CLICK
499
LDF4.5-50
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 501.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.865 (21.97) Diameter over Copper Outer Conductor, in (mm) 0.777 (19.74) Diameter Inner Conductor, in (mm) 0.277 (7.04) Minimum Bending Radius, in (mm) 8 (200) Number of Bends, minimum (typical) 15 (40) Bending Moment, lb-ft (Nm) 2.8 (3.8) Cable Weight, lb/ft (kg/m) 0.27 (0.402) Tensile Strength, lb (kg) 800 (363) Flat Plate Crush Strength, lb/in (kg/mm) 70 (1.3) 50 1 6.1 89 62 0.15 (0.49) 0.42 (1.37) 5000 8000 23.2 (76.1) 0.057 (0.187)
0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 6100
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
500
Revised 9/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L4.5PNM-RC
N Female L4.5PNF-RC
Connectors
Interface N Male N Female 7-16 DIN Male 7-16 DIN Female Description Ring Flare Ring Flare Ring Flare Ring Flare Type Number L4.5PNM-RC L4.5PNF-RC L4.5PDM-RC L4.5PDF-RC Inner Contact Attachment Captivated Captivated Captivated Captivated Outer Contact Attachment Self Flare Self Flare Self Flare Self Flare Plating Code SG SG SS SS Max. Length in (mm) 3.2 (81.5) 3.0 (76) 3.1 (78) 3.25 (82) Max. Dia. in (mm) 1.42 (36) 1.32 (33.5) 1.17 (29.8) 1.17 (29.8)
Plating Codes: SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624. Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 3/01
501
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706A-6 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L45SGRIP L45SGRIP-4IK 29958 L45CLICK
502
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
VXL5-50
Description Type No.
VXL5-50
VXL5RN-50
VXL5P-50-(**)
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) Copper Copper Tube 1.08 (27.5) 0.98 (24.9) 0.371 (9.42) 5 (125) 15 (40) 12 (16.3) 0.29 (0.43) 225 (102) 80 (1.4) 50 1 4.9 88 90 0.82 (2.70) 0.36 (1.19) 6000 8000 22.6 (74.2) 0.06 (0.197)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
503
N Male V5PNM-RPC
N Female V5PNF-RPC
Connectors
Interface Type Number Inner Contact Attachment Captivated Captivated Captivated Captivated Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Tapping Plating Code SG SG SS SS BB Max. Length in (mm) 2.9 (74) 2.7 (69) 2.7 (69) 2.33 (59) 3.38 (86) Max. Dia. in (mm) 1.46 (37.2) 1.46 (37.2) 1.46 (37.2) 1.46 (37.2) 2.27 (56.7)
N Male One-Piece V5PNM-RPC N Female One-Piece V5PNF-RPC 7-16 DIN Male One-Piece V5PDM-RPC 7-16 DIN Female One-Piece V5PDF-RPC 7/8" EIA Flange V5E78
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
504
Revised 9/00, 12/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
Snap-in Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706A-2 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L5SGRIP L5SGRIP-5IK 19256B L5CLICK
505
LDF5-50A
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 508.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, cm Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 5.0 89 91 0.32 (1.05) 0.36 (1.18) 6000 8000 22.8 (75.0) 0.057 (0.187) Copper Copper 1.09 (28) 0.98 (24.9) 0.355 (9.0) 2.11 10 (250) 15 (50) 12 (16.3) 0.33 (0.49) 325 (147) 80 (1.4)
* A 75-ohm 7/8" diameter cable is available. Contact Andrew for further information.
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
506
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L5PNM-RPC
N Female L5PNF-RPC
Connectors
Interface N Male N Male N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Male 7/8" EIA Flange 7/8" EIA Flange F Flange Male F Flange Female Splice Description OnePiece RingFlare OnePiece RingFlare OnePiece RingFlare OnePiece RingFlare Panel Mount Bulkhead Right Angle Right Angle Type Number L5PNM-RPC L5PNM-RC L5PNF-RPC L5PNF-RC L5PDM-RPC L5PDM-RC L5PDF-RPC L5PDF-RC L5PDF-PM L5PDF-BH L5PDR L45R 124800-1 L45F 48041 L45Z Inner Contact Attachment Captivated Captivated Captivated Captivated Captivated Captivated Captivated Captivated Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SS SS SS SS SS SS SS BB BB BB BB BB Max. Length in (mm) 2.9 (74) 3.0 (76) 2.7 (69) 2.9 (74) 2.7 (69) 3.1 (79) 2.33 (59.1) 2.9 (74) 2.7 (69) 2.7 (69) 3.3/2.5 (85/64) 3.3 (84) 3.9/1.3 (99/33) 1.8 (46) 1.8 (46) 3.3 (84) Max. Dia. in (mm) 1.46 (37.2) 1.35 (34.3) 1.46 (37.2) 1.35 (34.3) 1.46 (37.2) 1.34 (34.0) 1.46 (37.2) 1.36 (34.5) 1.35 (34.4) 1.9 (48.3) 1.4 (35.6) 2.25 (57) 2.25 (57) 2.25 (57) 2.25 (57) 1.5 (38)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00
507
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
1.38-1.540
LDF5P-50A-11A
1.7-2.2 1.60-2.3
LDF5P-50A-41 LDF5P-50A-12A
2.3-2.7
LDF5P-50A-13A
1.7-4.2
LDF5P-50A-7A
0.01-4.2*
LDF5P-50A-14A
0.01-5.0*
LDF5P-50A-15A
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
508
Revised 9/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For prepunched 3/4" (19 mm) holes on tower member or adapters. Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706A-2 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L5SGRIP L5SGRIP-5IK 19256B L5CLICK
Tools for additional tool offerings see pages 620-623 Grounding and Surge Protection for additional grounding
kits and our surge protection offerings, see pages 609-616 SureGround Grounding Kit with standard weatherproofing Factory attached one-hole lug, 600 mm (24") lead Factory attached two-hole lug, 600 mm (24") lead Field attached two-hole lug, 1500 mm (59") lead Factory attached one-hole lug, 600 mm (24") lead Factory attached two-hole lug, 600 mm (24") lead Field attached two-hole lug, 1500 mm (59") lead SGL5-06B1 SGL5-06B2 SGL5-15B4 SGPL5-06B1 SGPL5-06B2 SGPL5-15B4 EASIAX Plus Automated Cable Prep Tool EASIAX Cutting Tool Cable Flaring Tool 7/8" Connector Torque Wrench DIN Connector Coupling Torque Wrench N Connector Coupling Torque Wrench CPTL5A 222951 224368 244378 244377 244379
Arrestor Plus Integrated T-Series Arrestors see page 614 Bulkhead N Female APTL5-BNF-(*) Bulkhead 7-16 DIN Female APTL5-BDF-(*)
*Frequency band. See page 614.
509
VXL6-50
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 511
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) Copper Copper Tube 1.55 (39.4) 1.41 (35.8) 0.536 (13.6) 8 (200) 15 (50) 22 (30.4) 0.5 (0.74) 400 (181) 75 (1.3) 50 1 3.3 88 180 0.54 (1.77) 0.25 (0.82) 8500 10000 22.6 (74.2) 0.05 (0.194)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F).For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
510
Revised 9/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male V6PNM-RPC
N Female V6PNF-RPC
Connectors
Interface N Male N Female 7-16 DIN Male 7-16 DIN Female Description OnePiece OnePiece OnePiece OnePiece Type Number V6PNM-RPC V6PNF-RPC V6PDM-RPC V6PDF-RPC Inner Contact Attachment Captivated Captivated Captivated Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SS SS Max.Length in (mm) 3.3 (84) 4.0 (102) 3.6 (91) 3.5 (89) Max.Dia. in (mm) 2.03 (51.6) 2.03 (51.6) 2.03 (51.6) 2.03 (51.6)
Plating Codes: SG - Silver Plated Body and Gold Plated Pin. SS - Silver Plated Body and Pin.
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
* Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00 & 3/01
511
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-3 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L6SGRIP L6SGRIP-6IK 29961 L6CLICK
512
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
LDF6-50
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 515
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, cm Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 3.3 89 205 0.22 (0.72) 0.19 (0.62) 9000 10000 22.9 (75.1) 0.056 (0.184) Copper Copper 1.55 (39.4) 1.41 (35.8) 0.516 (13.1) 3.11 15 (380) 15 (40) 36 (49) 0.63 (0.94) 1300 (590) 125 (2.2)
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00
513
N Male L6PNM-RPC
N Female L6PNF-RPC
Connectors
Interface N Male N Female N Female 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange 1-5/8" EIA Flange F Flange Male Splice Description OnePiece OnePiece RingFlare OnePiece OnePiece Bulkhead RingFlare Type Number L6PNM-RPC L6PNF-RPC L6PNF-RC L6PDM-RPC L6PDF-RPC L6PDF-BH L6PDF-RC L46S L46R L46F L46Z Inner Contact Attachment Captivated Captivated Captivated Captivated Captivated Self-Tapping Captivated Self-Tapping Self-Tapping Self-Tapping Self-Tapping Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SS SS SS SS BB BB BB BB Max. Length in (mm) 3.8 (96) 3.1 (79) 3.4 (86) 3.4 (86) 3.4 (86) 4.1 (104) 3.2 (81) 4.6 (117) 5.1 (130) 4.0 (102) 3.0 (76) Max. Dia. in (mm) 2.03 (51.6) 2.03 (51.6) 2.0 (50.8) 2.03 (51.6) 2.03 (51.6) 2.0 (50.8) 2.0 (50.8) 2.25 (57) 3.5 (89) 2.25 (57) 2.0 (50.8)
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587. Standard VSWR Specifications
Frequency Band, GHz 0.806-0.960 and 1.7-2.0 1-25 ft (0.3-8 m) 1.10 (26.4)* 1.10 (26.4)* Assembly VSWR, Maximum (R.L., dB) 25-100 ft 100-200 ft 200-500 ft (8-30 m) (30-60 m) (60-150m) 1.11 (25.7)* 1.11 (25.7)* 1.12 (24.97)* 1.12 (24.97)* 1.13 (24.3)* 1.13 (24.3)* Above 500 ft (150 m) 1.13 (24.3)** 1.13 (24.3)**
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
514
Revised 7/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1.7-2.2 1.7-2.11
LDF6P-50-41 LDF6P-50-6A
1.85-2.2
LDF6P-50-7A
1.9-2.3
LDF6P-50-8A
2.3-2.7
LDF6P-50-9A
0.010-2.7*
LDF6P-50-10A
0.010-3.3*
LDF6P-50-11A
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 9/00 & 3/01
515
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-3 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L6SGRIP L6SGRIP-6IK 29961 L6CLICK
Arrestor Plus Integrated T-Series Arrestors see page 614 Bulkhead N Female APTL6-BNF-(*) Bulkhead 7-16 DIN Female APTL6-BDF-(*)
* Frequency band. See page 614
516
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
VXL7-50
Description Type No.
Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 2500
Attenuation dB/100 ft 0.014 0.019 0.024 0.027 0.062 0.088 0.109 0.142 0.191 0.205 0.213 0.254 0.276 0.297 0.372 0.437 0.467 0.496 0.503 0.550 0.602 0.650 0.662 0.694 0.724 0.742 0.848 0.947 1.02 1.13 1.23 1.30
Attenuation dB/100 m 0.044 0.063 0.077 0.089 0.202 0.289 0.356 0.465 0.627 0.671 0.699 0.834 0.904 0.976 1.22 1.43 1.53 1.63 1.65 1.81 1.97 2.13 2.17 2.28 2.38 2.43 2.78 3.11 3.35 3.71 4.05 4.27
Average Power, kW 247.0 175.0 142.0 123.0 54.3 38.1 30.9 23.6 17.5 16.4 15.7 13.2 12.2 11.3 9.01 7.67 7.18 6.76 6.67 6.09 5.57 5.15 5.06 4.83 4.63 4.52 3.95 3.54 3.28 2.96 2.72 2.58
** Insert suffix number from Low VSWR Specifications table, page 518
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) Copper Copper Tube 1.98 (50) 1.825 (46.3) 0.688 (17.5) 15 (375) 15 (50) 35 (48.4) 0.75 (1.12) 550 (249) 110 (2.0) 50 1 2.5 88 275 0.42 (1.39) 0.16 (0.52) 10500 10000 22.5 (73.8) 0.05 (0.194)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F).For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
517
N Male V7PNM-RPC
N Female V7PNF-RPC
Connectors
Interface N Male N Female 7-16 DIN Male 7-16 DIN Female Description OnePiece OnePiece OnePiece OnePiece Type Number V7PNM-RPC V7PNF-RPC V7PDM-RPC V7PDF-RPC Inner Contact Attachment Captivated Captivated Captivated Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SS SS Max.Length in (mm) 4.6 (117) 4.7 (119) 4.3 (109) 4.3 (109) Max.Dia. in (mm) 2.47 (62.7) 2.47 (62.7) 2.46 (62.5) 2.46 (62.5)
Plating Codes: SG - Silver Plated Body and Gold Plated Pin. SS - Silver Plated Body and Pin.
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
* Connectors ordered separately. VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
518
Revised 7/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-4 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L7SGRIP L7SGRIP-7IK 24312A L7CLICK
519
LDF7-50A
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 522.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, cm Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 2.5 88 315 0.25 (0.83) 0.16 (0.52) 11000 10000 23.1 (75.8) 0.058 (0.190) Copper Copper Tube 1.98 (50) 1.825 (46.3) 0.681 (17.3) 4.05 20 (510) 15 (50) 40 (54.2) 0.82 (1.2) 800 (363) 120 (2.1)
Standard Conditons: For Attenuation, VSWR 1.0, ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
520
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L7PNM-RPC
N Female L7PNF-RPC
Connectors
Interface N Male N Female N Female 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange 1-5/8" EIA Flange F Flange Flange Male F Flange Flange Female Splice Description OnePiece OnePiece RingFlare OnePiece OnePiece RingFlare Type Number L7PNM-RPC L7PNF-RPC L7PNF-RC L7PDM-RPC L7PDF-RPC L7PDF-RC L47S L47R L47F 201942 L47Z Inner Contact Attachment Captivated Captivated Captivated Captivated Captivated Captivated Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SS SG SG SS SS SS BB BB BB BB BB Max. Length in (mm) 4.4 (112) 4.5 (114) 4.2 (107) 4.2 (107) 4.1 (104) 3.4 (86) 5.1 (130) 5.1 (130) 5.9 (150) 5.5 (140) 5.1 (130) Max. Dia. in (mm) 2.47 (62.7) 2.47 (62.7) 2.36 (59.9) 2.46 (62.5) 2.45 (62.2) 2.36 (59.9) 2.25 (57) 3.5 (89) 2.25 (57) 2.25 (57) 2.9 (74)
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587. Standard VSWR Specifications
Frequency Band, GHz 0.806-0.960 and 1.7-2.0 1-25 ft (0.3-8 m) 1.10 (26.4)* 1.10 (26.4)* Assembly VSWR, Maximum (R.L., dB) 25-100 ft 100-200 ft 200-500 ft (8-30 m) (30-60 m) (60-150 m) 1.10 (26.4)* 1.10 (26.4)* 1.12 (24.97)* 1.12 (24.97)* 1.13 (24.3)* 1.13 (24.3)* Above 500 ft (150 m) 1.13 (24.3)** 1.13 (24.3)**
* Expected typical values based on guaranteed 1.13 VSWR for bulk cable and Type N or DIN straight connectors. If guaranteed values are required, contact Andrew. ** 1.13 VSWR guaranteed for bulk standard cable lengths 500 ft and above.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00
521
1.7-2.2 1.7-2.11
LDF7P-50A-41 LDF7P-50A-6A
1.85-2.11
LDF7P-50A-7A
1.9-2.3
LDF7P-50A-8A
2.1-2.2
LDF7P-50A-9A
0.01-2.5*
LDF7P-50A-10A
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
522
Revised 9/00 & 3/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
Snap-in Hangers Kit of 10. For prepunched 3/4" (19 mm) holes on tower member or adapters, Recommended maximum spacing is 3-ft. For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-4 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft Mounting Hardware see page 605 Kwik-Clamps Kit of 10. See page 607 for hanger options Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L7SGRIP L7SGRIP-7IK 24312 L7CLICK
Arrestor Plus Integrated T-Series Arrestors see page 614 Bulkhead N Female APTL7-BNF-(*) Bulkhead 7-16 DIN Female APTL7-BDF-(*)
* Frequency band. See page 614.
523
LDF12-50
Description Type No.
** Insert suffix number from Low VSWR Specifications table, page 525.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) One-Time Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 2.2 88 425 0.21 (0.68) 0.09 (0.29) 13000 10000 22.7 (74.6) 0.058 (0.189) Copper Copper Tube 2.35 (60) 2.2 (55.9) 0.835 (21.2) 22 (560) 9.5 (240) 15 (50) 70 (95) 1.22 (1.82) 1500 (681) 150 (2.7)
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
524
Revised 9/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connectors
Interface N Female 7-16 DIN Male 7-16 DIN Female 3 1/8" EIA Flange 3 1/8" EIA Flange Splice Description Gas Pass Gas Barrier Type Number L12PNF L12PDM L12PDF L12FP-302 L12FB-302 L12Z Inner Contact Attachment Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Self-Tapping Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SS SS SS BS BS BB Max. Length in (mm) 5.1 (130) 5.8 (147) 5.5 (139) 7.6 (192) 7.6 (192) 5.8 (147) Max. Dia. in (mm) 2.75 (69.9) 2.75 (69.9) 2.75 (69.9) 5.19 (131.8) 5.19 (131.8) 3.00 (76.2)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
Using Connector Type* N Female 7-16 DIN Female N Female 7-16 DIN Female N Female 7-16 DIN Female
* Connectors ordered separately VSWR values apply to straight connectors only, are guaranteed for factory fit assemblies, and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
525
Accessories
Description Type No. Description Type No.
Snap-in Hangers Kit of 10. For prepunched 3/4" (19mm) holes on tower member or adapters. Standard tower configuration spacing is 3-4 feet. (1-1.2m). For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598 206706-5 Support/Hoisting Grip. Use at 200-ft (60m) intervals. Grip with one clamp Support clamp kit of 10 Standard Hoisting Grip L12SGRIP L12SGRIP-12IK 31535
526
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HS1RP-50A
Description Type No.
HS1RP-50A
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 2 10 84 6.4 2.1 (6.8) 2.0 (6.5) 1600 4000 23.8 (78.0) 0.061 (0.202) Copper Copper 0.29 (7.4) 0.25 (6.4) 1 (25) 15 (20) 1.9 (2.6) 0.063 (45) 100 (45) 80 (1.4)
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F); no solar loading.
527
N Male F1PNMV2-H
Connectors
Interface N Male N Male N Male N Female N Female BNC Male UHF Male UHF Female SMA Male SMA Male SMA Female SMA Male SMA Female TNC Male TNC Female TNC Male Mini-UHF Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female Description Hex Head High Freq. Right Angle Hex Head Bulkhead Up to 6 GHz Right Angle Up to 6 GHz, Bulkhead Up to 18 GHz Up to 18 GHz 11 GHz and Below Bulkhead Hi Freq, Above 11 GHz Panel Mount Bulkhead Type Number F1PNMV2-H F1PNM-HF F1PNR-HC F1PNF F1PNF-BH F1PBM 41SP 41U F1PSM F1PSR F1PSF 41EWS 41ENS F1PTM 41AENT F1PTM-HF F1MU F1PDM F1PDF F1PDF-PM F1PDF-BH Inner Contact Attachment Solder Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Captivated Captivated Captivated Solder Solder Solder Solder Outer Contact Attachment Self-Clamping Tab Flare Self-Clamping Self-Flare Self-Clamping Self-Clamping Solder Solder Self-Clamping Self-Clamping Self-Clamping Tab Flare Tab Flare Self-Clamping Tab Flare Tab Flare Crimp Self-Clamping Self-Clamping Self-Clamping Self Clamping Plating Code SG SG SG SG SG SS BB BS PG PG PG G G SG NG NG NS SS SS SS SS Max. Length in (mm) 2.1 (53) 1.3 (33) 1.7/1.3 (43/33) 2.2 (55.2) 2.3 (58) 2.0 (50) 1.8 (46) 2.1 (53) 1.7 (43) 1.6/0.75 (41/19) 1.7 (43) 0.94 (23.9) 1.00 (25.4) 1.68 (43) 1.5 (38) 1.9 (48.8) 1.53 (39) 1.82 (46.3) 1.85 (47) 1.85 (47) 1.85 (47) Max. Dia. in (mm) 0.95 (24.1) 0.81 (20.5) 0.95 (24.1) 0.58 (14.8) 0.94 (23.9) 0.69 (17.5) 0.77 (19.6) 0.77 (19.6) 0.49 (12.5) 0.50 (12.7) 0.49 (12.5) 0.40 (10.2) 0.40 (10.2) 0.57 (14.5) 0.70 (17.8) 0.70 (17.8) 0.47 (11.9) 1.25 (31.75) 0.551 (14) 1.26 (32) 1.62 (41)
* Stainless steel body Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, NS- Nickel Plated Body and Silver Plated Pin, PG - Passivated Body and Gold Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, G - Stainless Steel Body and Gold Plated Pin.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587. Accessories
Description Type No.
Description
Type No.
528
Revised 7/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1/4'' High Power, High Temperature, Air Dielectric, HST Series 50-ohm
HST1-50
Description Type No.
Characteristics
Electrical Impedance, ohms 50 2 Maximum Frequency, GHz 18 Velocity, percent 82 Peak Power Rating, kW 6.4 dc Resistance, ohms/1000 ft (1000 m) Inner 2.05 (6.71) Outer 2.0 (6.5) dc Breakdown, volts 1600 Jacket Spark, volts RMS 4000 Capacitance, pF/ft (m) 25.1 (82.4) Inductance, H/ft (m) 0.061 (0.202) Mechanical Outer Conductor Copper Inner Conductor Silver Plated Copper Diameter over Jacket, in (mm) 0.29 (7.4) Diameter over Copper Outer Conductor, in (mm) 0.25 (6.4) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum (typical) 15 (20) Bending Moment, lb-ft (Nm) 1.7 (2.3) Cable Weight, lb/ft (kg/m) 0.057 (0.085) Tensile Strength, lb (kg) 100 (45) Flat Plate Crush Strength, lb/in (kg/mm) 80 (1.4)
Standard Conditons: For Attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power. VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 200C (392F); no solar loading.
529
N Male F1PNMV2-H
Connectors
Interface N Male N Male N Male N Female N Female BNC Male UHF Male UHF Female SMA Male SMA Male SMA Female SMA Male SMA Female TNC Male TNC Female TNC Male Mini-UHF Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female Description Hex Head High Freq. Right Angle Hex Head Bulkhead Up to 6 GHz Right Angle Up to 6 GHz, Bulkhead Up to 18 GHz Up to 18 GHz 11 GHz and Below Bulkhead Hi Freq, Above 11 GHz Panel Mount Bulkhead Type Number F1PNMV2-H F1PNM-HF F1PNR-HC F1PNF F1PNF-BH F1PBM 41SP 41U F1PSM F1PSR F1PSF 41EWS 41ENS F1PTM 41AENT F1PTM-HF F1MU F1PDM F1PDF F1PDF-PM F1PDF-BH Inner Contact Attachment Solder Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Captivated Captivated Captivated Solder Solder Solder Solder Outer Contact Attachment Self-Clamping Tab Flare Self-Clamping Self-Flare Self-Clamping Self-Clamping Solder Solder Self-Clamping Self-Clamping Self-Clamping Tab Flare Tab Flare Self-Clamping Tab Flare Tab Flare Crimp Self-Clamping Self-Clamping Self-Clamping Self Clamping Plating Code SG SG SG SG SG SS BB BS PG PG PG G G SG NG NG NS SS SS SS SS Max. Length in (mm) 2.1 (53) 1.3 (33) 1.7/1.3 (43/33) 2.2 (55.2) 2.3 (58) 2.0 (50) 1.8 (46) 2.1 (53) 1.7 (43) 1.6/0.75 (41/19) 1.7 (43) 0.94 (23.9) 1.00 (25.4) 1.68 (43) 1.5 (38) 1.9 (48.8) 1.53 (39) 1.82 (46.3) 1.85 (47) 1.85 (47) 1.85 (47) Max. Dia. in (mm) 0.95 (24.1) 0.81 (20.5) 0.95 (24.1) 0.58 (14.8) 0.94 (23.9) 0.69 (17.5) 0.77 (19.6) 0.77 (19.6) 0.49 (12.5) 0.50 (12.7) 0.49 (12.5) 0.40 (10.2) 0.40 (10.2) 0.57 (14.5) 0.70 (17.8) 0.70 (17.8) 0.47 (11.9) 1.25 (31.75) 0.551 (14) 1.26 (32) 1.62 (41)
* Stainless steel body Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NG - Nickel Plated Body and Gold Plated Pin, NS- Nickel Plated Body and Silver Plated Pin, PG - Passivated Body and Gold Plated Pin+A135, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, G - Stainless Steel Body and Gold Plated Pin.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587. Accessories
Description Type No.
Description
Type No.
530
Revised 7/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HS2RP-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 13400 Attenuation dB/100 ft 0.083 0.118 0.144 0.166 0.374 0.530 0.650 0.843 1.12 1.20 1.25 1.48 1.59 1.71 2.11 2.45 2.61 2.76 2.79 3.03 3.29 3.53 3.59 3.75 3.89 3.98 4.48 4.94 5.29 5.46 5.78 5.94 6.09 6.24 7.23 7.75 8.49 9.63 10.7 12.6 14.4 16.1 17.2 Attenuation dB/100 m 0.273 0.386 0.473 0.546 1.23 1.74 2.13 2.76 3.69 3.94 4.09 4.84 5.23 5.62 6.93 8.05 8.56 9.04 9.16 9.95 10.8 11.6 11.8 12.3 12.8 13.0 14.7 16.2 17.4 17.9 19.0 19.5 20.0 20.5 23.7 25.4 27.8 31.6 35.1 41.4 47.2 52.7 56.3 Average Power, kW 13.2 13.2 12.1 10.5 4.67 3.30 2.69 2.07 1.55 1.46 1.40 1.18 1.10 1.02 0.827 0.712 0.670 0.634 0.626 0.576 0.531 0.495 0.487 0.466 0.449 0.439 0.390 0.354 0.330 0.320 0.302 0.294 0.287 0.280 0.242 0.226 0.206 0.182 0.164 0.138 0.121 0.109 0.102
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.415 (10.5) Diameter over Copper Outer Conductor, in (mm) 0.375 (9.5) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum 20 (50) Bending Moment, lb-ft (Nm) 1.8 (2.45) Cable Weight, lb/ft. (kg/m) 0.076 (0.113) Tensile Strength, lb (kg) 210 (95) Flat Plate Crush Strength, lb/in (kg/mm) 100 (1.8) 50 2 13.4 83 13.2 1.41 (4.64) 1.52 (4.99) 2300 5000 23.61 (77.47) 0.064 (0.208)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 9/00
531
N Male F2PNM-H
N Female F2PNF
Connectors
Interface N Male N Male N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Male Description Hex Head Hex Head Type Number F2PNM-H F2PNM-HC F2PNF F2PNF-C F2PNF-BH F2PDM F2PDM-C F2PDF F2PDF-C F2PDF-PM F2PDR-C Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Captivated Solder Captivated Solder Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SS SS SS SS SS SS Max. Length in (mm) 1.9 (48) 1.9 (48) 2.1 (53) 2.1 (53) 2.1 (53) 2.2 (57) 2.1 (53) 2.2 (56) 2.1 (51.6) 2.2 (56) 1.7/1.3 (43/34) Max. Dia. in (mm) 0.94 (23) 0.94 (23) 0.67 (17) 0.64 (16) 0.95 (24) 1.4 (36) 1.4 (36) 1.1 (28) 0.79 (20) 1.1 (28) 1.4 (36)
Bulkhead
Plating Codes: SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, BS - Brass Body and Silver Plated Pin.
Accessories
Description Type No.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
Accessories
Description Type No.
532
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
3/8" High Power, High Temperature Plenum Rated, Air Dielectric, HST Series 50-ohm
HST2-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 12000 13400 Attenuation dB/100 ft 0.085 0.120 0.147 0.170 0.383 0.543 0.667 0.865 1.16 1.23 1.28 1.52 1.64 1.76 2.18 2.54 2.70 2.85 2.89 3.14 3.41 3.66 3.72 3.89 4.04 4.13 4.67 5.16 5.52 5.70 6.04 6.21 6.37 6.53 7.59 8.15 8.95 10.2 11.3 13.4 15.4 17.2 18.4 Attenuation dB/100 m 0.279 0.395 0.484 0.559 1.26 1.78 2.19 2.84 3.79 4.05 4.21 4.99 5.39 5.79 7.15 8.32 8.85 9.36 9.48 10.3 11.2 12.0 12.2 12.8 13.3 13.6 15.3 16.9 18.1 18.7 19.8 20.4 20.9 21.4 24.9 26.7 29.4 33.4 37.2 44.1 50.5 56.5 60.5 Average Power, kW 13.2 13.2 13.2 13.2 13.2 12.3 9.98 7.70 5.76 5.40 5.19 4.38 4.06 3.77 3.06 2.63 2.47 2.34 2.31 2.12 1.95 1.82 1.79 1.71 1.65 1.61 1.43 1.29 1.21 1.17 1.10 1.07 1.05 1.02 0.878 0.818 0.745 0.655 0.588 0.496 0.433 0.387 0.362
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Copper Inner Conductor Silver Plated, Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.415 (10.5) Diameter over Copper Outer Conductor, in (mm) 0.375 (9.5) Minimum Bending Radius, in (mm) 1 (25) Number of Bends, minimum 20 (50) Bending Moment, lb-ft (Nm) 1.8 (2.45) Cable Weight, lb/ft. (kg/m) 0.094 (0.140) Tensile Strength, lb (kg) 210 (95) Flat Plate Crush Strength, lb/in (kg/mm) 100 (1.8) 50 2 13.4 83 13.2 1.41 (4.64) 1.52 (4.99) 2300 5000 23.61 (77.47) 0.064 (0.208)
Standard Conditions: For attenuation. VSWR 1.0, ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 200C (392F), no solar loading.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 9/00
533
N Male F2PNM-H
N Female F2PNF
Connectors
Interface N Male N Male N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Male Description Hex Head Hex Head Type Number F2PNM-H F2PNM-HC F2PNF F2PNF-C F2PNF-BH F2PDM F2PDM-C F2PDF F2PDF-C F2PDF-PM F2PDR-C Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Captivated Solder Captivated Solder Captivated Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SS SS SS SS SS SS Max. Length in (mm) 1.9 (48) 1.9 (48) 2.1 (53) 2.1 (53) 2.1 (53) 2.2 (57) 2.1 (53) 2.2 (56) 2.1 (51.6) 2.2 (56) 1.7/1.3 (43/34) Max. Dia. in (mm) 0.94 (23) 0.94 (23) 0.67 (17) 0.64 (16) 0.95 (24) 1.4 (36) 1.4 (36) 1.1 (28) 0.79 (20) 1.1 (28) 1.4 (36)
Bulkhead
Plating Codes: SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin, BS - Brass Body and Silver Plated Pin.
Accessories
Description Type No.
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
Accessories
Description Type No.
534
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HJ4-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 3000 4000 5000 6000 8000 10000 10900 Attenuation dB/100 ft 0.0560 0.0792 0.0971 0.112 0.253 0.359 0.442 0.574 0.768 0.821 0.854 1.01 1.10 1.18 1.46 1.71 1.82 1.92 1.95 2.12 2.31 2.49 2.53 2.64 2.75 2.81 3.19 3.53 3.80 4.17 4.52 5.28 6.27 7.17 8.03 9.61 11.1 11.7 Attenuation dB/100 m 0.184 0.260 0.319 0.37 0.83 1.18 1.45 1.88 2.52 2.69 2.80 3.33 3.60 3.87 4.80 5.60 5.96 6.31 6.39 6.97 7.58 8.16 8.29 8.68 9.03 9.23 10.5 11.6 12.5 13.7 14.8 17.3 20.6 23.5 26.3 31.5 36.4 38.4 Average Power, kW 21.0 21.0 20.0 17.3 7.69 5.41 4.40 3.38 2.53 2.37 2.27 1.91 1.77 1.65 1.33 1.14 1.07 1.01 1.00 0.914 0.840 0.781 0.768 0.734 0.706 0.690 0.609 0.549 0.512 0.466 0.430 0.368 0.310 0.271 0.242 0.202 0.175 0.166
** Insert suffix number from Low VSWR Specifications table, page 537.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, cm Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush, lb/in (kg/mm) 50 1 10.9 91.4 21.0 0.45 (1.48) 0.40 (1.31) 2900 8000 22.2 (73.0) 0.056 (0.182) Copper Copper 0.58 (14.7) 0.50 (12.7) 0.165 (4.2) 0.90 5 (125) 15 (20) 8 (10.9) 0.25 (0.37) 700 (320) 250 (4.5)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. Operation of this cable in the 5350-5500 MHz band is not recommended because of VSWR spikes produced by the dielectric section spacing.
535
N Male H4PNM
N Female H4PNF
Connectors
Interface N Male N Female 7-16 DIN Male 7/8" EIA Flange End Terminal Splice Description Type Number H4PNM H4PNF H4PDM H4MPB-014 74T 74Z Reference* Inner Contact Attachment Solder Solder Spring Finger Solder Solder Solder Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SS BB BB BB Max. Length in (mm) 2.8 (71) 2.8 (71) 2.6 (66) 3.3 (84) 4.6 (117) 4.9 (124) Max. Dia. in (mm) 1.0 (25) 1.0 (25) 1.3 (33) 2.25 (57) 0.9 (23) 1.1 (28)
74ARG
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin * Previous Type Number.
Connector Accessories
Type Number Connector Reattachment Kit for H4PNF, H4PNM, 74PN, 74PW Bulkhead Adapter, for N Females 7/8" EIA Gas Barrier 34767A-22 26016-2 1260A
536
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
3.625-4.2 *
HJ4P-50-2
* Specify operating band ** Connectors ordered separately. VSWR values are guaranteed for factory fit assemblies and are typical for cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Snap-In Hangers Kit of 10. For pre-punched 3/4" (19mm) holes on tower member or adapters. Recommended maximum spacing is 3-ft (1 m). For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598. 206706-1 Standard Hoisting Grip 43094
537
HT4-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 3000 4000 5000 6000 8000 10000 10900 Attenuation dB/100 ft 0.0580 0.0822 0.101 0.117 0.265 0.379 0.468 0.613 0.829 0.888 0.926 1.11 1.20 1.30 1.63 1.92 2.06 2.19 2.22 2.43 2.67 2.89 2.94 3.09 3.23 3.31 3.79 4.25 4.60 5.10 5.59 6.65 8.07 9.41 10.7 13.1 15.5 16.5 Attenuation dB/100 m 0.190 0.270 0.331 0.383 0.870 1.24 1.54 2.01 2.72 2.91 3.04 3.63 3.94 4.26 5.35 6.31 6.75 7.18 7.28 7.99 8.75 9.48 9.65 10.1 10.6 10.9 12.4 13.9 15.1 16.7 18.3 21.8 26.5 30.9 35.1 43.1 50.7 54.0 Average Power, kW 21.0 21.0 21.0 21.0 20.8 14.5 11.8 9.00 6.65 6.21 5.96 4.98 4.59 4.25 3.38 2.87 2.68 2.52 2.49 2.27 2.07 1.91 1.88 1.79 1.71 1.67 1.45 1.30 1.20 1.08 0.987 0.829 0.683 0.586 0.516 0.420 0.357 0.335
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Copper Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush, lb/in (kg/mm) 50 1 10.9 92.0 21.0 0.45 (1.48) 0.40 (1.31) 2900 22.0 (72.2) 0.056 (0.182) Copper Copper 0.50 (12.7) 5 (125) 15 (30) 7.3 (9.9) 0.21 (0.31) 830 (380) 290 (5.3)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 200C (392F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. Operation of this cable in the 5400-5600 MHz band is not recommended because of VSWR spikes produced by the dielectric section spacing.
538
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male H4PNM
N Female H4PNF
Connectors
Interface N Male N Female 7-16 DIN Male 7/8" EIA Flange End Terminal Splice Description Type Number H4PNM H4PNF H4PDM H4MPB-014 74T 74Z Reference* Inner Contact Attachment Solder Solder Spring Finger Solder Solder Solder Outer Contact Attachment Self Flare Self Flare Self Flare Self Flare Self Flare Self Flare Plating Code SG SG SS BB BB BB Max. Length in (mm) 2.8 (71) 2.8 (71) 2.6 (66) 3.3 (84) 4.6 (117) 4.9 (124) Max. Dia. in (mm) 1.0 (25) 1.0 (25) 1.3 (33) 2.25 (57) 0.9 (23) 1.1 (28)
74ARG
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin * Previous Type Number.
Connector Accessories
Type Number Connector Reattachment Kit for H4PNF, H4PNM, 74PN, 74PW Bulkhead Adapter, for N Females 7/8" EIA Gas Barrier 34767A-22 26016-2 1260A
Accessories
Description Type No. Description Type No.
539
HL4RP-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 Attenuation dB/100 ft 0.049 0.070 0.086 0.099 0.223 0.317 0.389 0.506 0.678 0.725 0.754 0.896 0.968 1.04 1.29 1.51 1.61 1.70 1.73 1.88 2.05 2.20 2.24 2.34 2.44 2.50 2.83 3.14 3.37 3.49 3.71 3.81 3.92 4.02 4.70 5.07 5.59 6.41 7.18 Attenuation dB/100 m 0.162 0.229 0.281 0.324 0.730 1.04 1.28 1.66 2.22 2.38 2.47 2.94 3.18 3.42 4.24 4.95 5.28 5.59 5.66 6.17 6.72 7.23 7.35 7.69 8.00 8.19 9.29 10.3 11.1 11.4 12.2 12.5 12.9 13.2 15.4 16.6 18.3 21.0 23.6 Average Power, kW 40.0 37.8 30.9 26.7 11.9 8.34 6.78 5.22 3.89 3.64 3.50 2.95 2.73 2.53 2.04 1.75 1.64 1.55 1.53 1.40 1.29 1.20 1.18 1.13 1.08 1.06 0.933 0.841 0.783 0.758 0.713 0.693 0.675 0.657 0.562 0.521 0.473 0.412 0.368
HL4RP-50
Characteristics
Electrical Impedance, ohms 50 2 Maximum Frequency, GHz 6.0 Velocity, percent 88.0 Peak Power Rating, kW 21.0 dc Resistance, ohms/1000 ft (1000 m) Inner 0.45 (1.48) Outer 0.58 (1.90) dc Breakdown, volts 4000 Capacitance, pF/ft (m) 23.0 (75.3) Inductance, H/ft (m) 0.058 (0.191) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.61 (15.5) Diameter over Copper Outer Conductor, in (mm) 0.55 (14) Minimum Bending Radius, in (mm) 5 (125) Number of Bends, minimum (typical) 10 (15) Bending Moment, lb-ft (Nm) 3.0 (4.1) Cable Weight, lb/ft (kg/m) 0.18 (0.27) Tensile Strength, lb (kg) 250 (114) Flat Plate Crush, lb/in (kg/mm) 80 (1.4)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
540
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L4PNM-RC
N Female L4PNF-RC
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange 7/8" EIA Flange F Flange Male F Flange Female UHF Male UHF Female HN Male LC Male TNC Female End Terminal Splice Description Hex Head RingFlare Right Angle, Hex Right Angle, Hex Bulk Head Panel Mount RingFlare Right Angle Right Angle RingFlare Bulk Head Bulk Head Panel Mount RingFlare Right Angle Type Number L4PNM-H L4PNM-RC L4PNR-H L4PNR-HC L4PNF L4PNF-BH L4PNF-PM L4PNF-RC L4PDM L4PDR L4PDR-C L4PDM-RC L4PDF L4PDF-BH L4PDF-BHC L4PDF-PM L4PDF-RC L44R 124990-1 L44F 209865 L44P L44U L44J L44M L44NT L44T L44Z Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Solder Captivated Solder Solder Captivated Captivated Solder Solder Captivated Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Outer Contact Attachment Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS BB BB BB BS BB BS BB BB BB BB BB Max. Length in (mm) 2.6 (66) 3.0 (75.7) 3.2/1.5 (81/38) 3.2/1.5 (81/38) 2.6 (66) 2.6 (66) 2.6 (66) 2.8 (71) 2.6 (66) 1.8/2.8 (46/72) 1.8/2.8 (46/72) 2.64 (67.1) 2.7 (69) 2.73 (69.4) 2.9 (74) 2.7 (69) 2.8 (71) 3.2 (81) 2.3/1.6 (58/41) 2.3 (58) 2.3 (58) 2.3 (58) 2.3 (58) 2.5 (64) 3.6 (91) 2.8 (71) 4.0 (102) 3.2 (81) Max. Dia. in (mm) 0.95 (24.1) 0.86 (21.8) 0.95 (24.1) 0.91 (23.1) 0.94 (23.9) 0.96 (24.4) 1.0 (25.4) 0.86 (21.8) 1.4 (35.6) 1.41 (35.9) 1.41 (35.9) 0.86 (21.8) 1.1 (27.9) 1.62 (41.1) 1.63 (41.4) 1.2 (29.4) 0.86 (21.8) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.94 (23.9) 0.91 (23.1) 1.1 (27.9)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
541
Accessories
Description Type No. Description Type No.
542
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1/2" Air Dielectric, High Power High Temperature, HLT Series 50-ohm
HLT4-50T
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 Attenuation dB/100 ft 0.047 0.066 0.081 0.094 0.213 0.305 0.377 0.494 0.669 0.718 0.748 0.896 0.973 1.05 1.32 1.56 1.67 1.78 1.80 1.98 2.17 2.35 2.40 2.52 2.63 2.70 3.10 3.48 3.77 3.91 4.18 4.32 4.45 4.58 5.47 5.95 6.65 Attenuation dB/100 m 0.153 0.217 0.266 0.308 0.700 1.00 1.24 1.62 2.20 2.35 2.45 2.94 3.19 3.45 4.34 5.12 5.48 5.83 5.91 6.50 7.12 7.72 7.86 8.26 8.63 8.85 10.2 11.4 12.4 12.8 13.7 14.2 14.6 15.0 17.9 19.5 21.8 Average Power, kW 21.4 21.4 21.4 21.4 21.4 15.7 12.7 9.72 7.18 6.70 6.42 5.36 4.94 4.57 3.64 3.08 2.88 2.70 2.67 2.43 2.22 2.04 2.01 1.91 1.83 1.78 1.55 1.38 1.28 1.23 1.15 1.11 1.08 1.05 0.881 0.809 0.724
HLT4-50T
Characteristics
Electrical Impedance, ohms 52.5 2 Maximum Frequency, GHz 4.0 Velocity, percent 93.0 Peak Power Rating, kW 21.4 dc Resistance, ohms/1000 ft (1000 m) Inner 0.45 (1.48) Outer 0.58 (1.90) dc Breakdown, volts 3000 Capacitance, pF/ft (m) 20.4 (66.8) Inductance, H/ft (m) 0.058 (0.191) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.61 (15.5) Diameter over Copper Outer Conductor, in (mm) 0.55 (14) Diameter Inner Conductor, in (mm) 0.189 (4.8) Minimum Bending Radius, in (mm) 5 (125) Number of Bends, minimum (typical) 10 (15) Bending Moment, lb-ft (Nm) 3.0 (4.1) Cable Weight, lb/ft (kg/m) 0.18 (0.27) Tensile Strength, lb (kg) 250 (114) Flat Plate Crush, lb/in (kg/mm) 100 (1.8)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 200C (392F), no solar loading.
543
N Male L4PNM-RC
N Female L4PNF-RC
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female N Female 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange 7/8" EIA Flange F Flange Male F Flange Female UHF Male UHF Female HN Male LC Male TNC Female End Terminal Splice Description Hex Head RingFlare Right Angle, Hex Right Angle Bulk Head Panel Mount RingFlare Right Angle Right Angle RingFlare Bulk Head Bulk Head Panel Mount RingFlare Right Angle Type Number L4PNM-H L4PNM-RC L4PNR-H L4PNR-HC L4PNF L4PNF-BH L4PNF-PM L4PNF-RC L4PDM L4PDR L4PDR-C L4PDM-RC L4PDF L4PDF-BH L4PDF-BHC L4PDF-PM L4PDF-RC L44R 124990-1 L44F 209865 L44P L44U L44J L44M L44NT L44T L44Z Inner Contact Attachment Solder Captivated Solder Captivated Solder Solder Solder Captivated Solder Solder Captivated Captivated Solder Solder Captivated Solder Captivated Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Solder Outer Contact Attachment Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare RingFlare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Plating Code SG SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS BB BB BB BS BB BS BB BB BB BB BB Max. Length in (mm) 2.6 (66) 3.0 (75.7) 3.2/1.5 (81/38) 3.2/1.5 (81/38) 2.6 (66) 2.6 (66) 2.6 (66) 2.8 (71) 2.6 (66) 1.8/2.8 (46/72) 1.8/2.8 (46/72) 2.64 (67.1) 2.7 (69) 2.73 (69.4) 2.9 (74) 2.7 (69) 2.8 (71) 3.2 (81) 2.3/1.6 (58/41) 2.3 (58) 2.3 (58) 2.3 (58) 2.3 (58) 2.5 (64) 3.6 (91) 2.8 (71) 4.0 (102) 3.2 (81) Max. Dia. in (mm) 0.95 (24.1) 0.86 (21.8) 0.95 (24.1) 0.91 (23.1) 0.94 (23.9) 0.96 (24.4) 1.0 (25.4) 0.86 (21.8) 1.4 (35.6) 1.41 (35.9) 1.41 (35.9) 0.86 (21.8) 1.1 (27.9) 1.62 (41.1) 1.63 (41.4) 1.2 (29.4) 0.86 (21.8) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 2.25 (57.2) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.94 (23.9) 0.91 (23.1) 1.1 (27.9)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
544
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No.
Accessories
Description Type No.
545
HS4RP-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 10200 Attenuation dB/100 ft 0.065 0.092 0.113 0.131 0.294 0.417 0.512 0.664 0.887 0.947 0.985 1.17 1.26 1.35 1.67 1.94 2.07 2.19 2.21 2.41 2.61 2.81 2.85 2.98 3.09 3.16 3.57 3.94 4.22 4.36 4.62 4.75 4.87 4.99 5.79 6.22 6.82 7.76 8.63 10.2 11.7 11.8 Attenuation dB/100 m 0.214 0.303 0.372 0.429 0.965 1.37 1.68 2.18 2.91 3.11 3.23 3.83 4.13 4.44 5.48 6.37 6.78 7.17 7.26 7.90 8.57 9.21 9.35 9.77 10.2 10.4 11.7 12.9 13.9 14.3 15.2 15.6 16.0 16.4 19.0 20.4 22.4 25.5 28.3 33.6 38.4 38.8 Average Power, kW 15.6 15.6 15.0 13.0 5.77 4.07 3.31 2.55 1.91 1.79 1.72 1.46 1.35 1.25 1.02 0.874 0.821 0.777 0.767 0.705 0.650 0.605 0.595 0.570 0.549 0.537 0.476 0.431 0.402 0.390 0.368 0.358 0.349 0.340 0.293 0.273 0.249 0.219 0.197 0.166 0.145 0.144
Characteristics
Electrical Impedance, ohms 50 2 Maximum Frequency, GHz 10.2 Velocity, percent 81 Peak Power Rating, kW 15.6 dc Resistance, ohms/1000 ft (1000 m) Inner 0.87 (2.85) Outer 1.00 (3.28) dc Breakdown, volts 2500 Jacket Spark, volts RMS 5000 Capacitance, pF/ft (m) 25.04 (82.16) Inductance, H/ft (m) 0.063 (0.206) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.52 (13.2) Diameter over Copper Outer Conductor, in (mm) 0.48 (12.2) Minimum Bending Radius, in (mm) 1.25 (32) Number of Bends, minimum 20 (50) Bending Moment, lb-ft (Nm) 4.5 (6.12) Cable Weight, lb/ft (kg/m) 0.138 (0.205) Tensile Strength, lb (kg) 175 (80) Flat Plate Crush Strength, lb/in (kg/mm) 110 (1.9)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
546
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male F4PNMV2-H
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female 4.1/9.5 DIN Male 4.1/9.5 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange UHF Male UHF Female HN Male SC Male Description Hex Head Hex Head Rt Angle, Hex Hd Bulkhead Rt Angle, Outdoor Use Right Angle Right Angle Bulkhead Panel Mount Bulkhead Panel Mount Type Number F4PNMV2-H F4PNMV2-HC F4PNR-H F4PNR-HC F4PNF F4PNF-C F4PNF-BH F4PKM-C F4PKR-C F4PDMV2-C F4PDMV2 F4PDR F4PDR-C F4PDF-C F4PDF F4PDF-BH F4PDF-PM F4PDF-BHC F4PDF-PMC 44ASR 44ASP 44ASU 44ASJ 44SPCW Inner Contact Attachment Solder Captivated Solder Captivated Solder Captivated Solder Captivated Captivated Captivated Solder Solder Captivated Captivated Solder Solder Solder Captivated Captivated Solder Solder Solder Solder Solder Outer Contact Attachment Crush-Flare Crush-Flare Tab-Flare Crush-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Crush-Flare Crush-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Plating Code SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS SS SS SS BS BS BS BB SG Max. Length in (mm) 2.13 (54.0) 2.13 (54.0) 3.3/1.5 (84/38) 2.8 (71.9)/1.6 (41.5) 2.3 (53.3) 2.3 (53.3) 2.3 (58) 2.0 (50) 2.3/1.5 (57/38) 1.98 (50.2) 2.10 (53.4) 2.4.1.8 (61/46) 2.1/2.0 (53/50) 2.0 (50) 2.0 (50) 2.01 (51.1) 2.01 (51.1) 2.0 (50) 2.0 (50) 3.3 (84) 2.1 (53) 2.3 (58) 2.4 (61) 2.7 (69) Max. Dia. in (mm) 0.94 (23.8) 0.94 (23.8) 0.86 (21.8) 1 (25.7) 0.88 (22.4) 0.88 (22.4) 0.95 (24.1) 0.95 (24.1) 0.95 (24.1) 1.05 (26.7) 1.05 (26.7) 1.4 (35.6) 1.4 (35.6) 1.1 (27.9) 1.1 (27.9) 1.50 (38) 1.26 (32) 1.8 (45.7) 1.3 (33) 1.4 (35.6) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.88 (22.4)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
547
Accessories
Description Type No. Description Type No.
548
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
1/2" High Power, High Temperature, Plenum Rated Air Dielectric, HST Series 50-ohm
HST4-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 6000 8000 10000 10200 Attenuation dB/100 ft 0.074 0.105 0.129 0.149 0.335 0.477 0.586 0.762 1.02 1.09 1.13 1.35 1.46 1.57 1.94 2.27 2.42 2.56 2.59 2.82 3.07 3.31 3.36 3.52 3.66 3.74 4.24 4.71 5.05 5.22 5.55 5.71 5.86 6.02 7.04 7.58 8.36 9.57 10.7 12.8 14.8 15.0 Attenuation dB/100 m 0.244 0.345 0.423 0.489 1.10 1.56 1.92 2.50 3.35 3.58 3.72 4.42 4.78 5.14 6.38 7.44 7.93 8.39 8.50 9.27 10.1 10.9 11.0 11.5 12.0 12.3 13.9 15.4 16.6 17.1 18.2 18.7 19.2 19.7 23.1 24.9 27.4 31.4 35.1 42.1 48.6 49.2 Average Power, kW 15.6 15.6 15.6 15.6 15.6 15.6 15.6 13.3 9.92 9.29 8.92 7.52 6.95 6.46 5.21 4.47 4.19 3.96 3.91 3.59 3.30 3.06 3.01 2.88 2.77 2.71 2.39 2.15 2.00 1.94 1.83 1.78 1.73 1.68 1.44 1.34 1.21 1.06 0.947 0.790 0.685 0.676
Characteristics
Electrical Impedance, ohms 50 2 Maximum Frequency, GHz 10.2 Velocity, percent 81 Peak Power Rating, kW 15.6 dc Resistance, ohms/1000 ft (1000 m) Inner 0.87 (2.85) Outer 1.00 (3.28) dc Breakdown, volts 2500 Jacket Spark, volts RMS 4000 Capacitance, pF/ft (m) 25.04 (82.16) Inductance, H/ft (m) 0.063 (0.206) Mechanical Outer Conductor Copper Inner Conductor Silver Plated, Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.52 (13.2) Diameter over Copper Outer Conductor, in (mm) 0.48 (12.2) Minimum Bending Radius, in (mm) 1.25 (32) Number of Bends, minimum 20 (50) Bending Moment, lb-ft (Nm) 4.57 (6.22) Cable Weight, lb/ft (kg/m) 0.165 (0.245) Tensile Strength, lb (kg) 175 (80) Flat Plate Crush Strength, lb/in (kg/mm) 110 (1.9)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 200C (392F), no solar loading.
549
N Male F4PNMV2-H
Connectors
Interface N Male N Male N Male N Male N Female N Female N Female 4.1/9.5 DIN Male 4.1/9.5 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Male 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7-16 DIN Female 7/8" EIA Flange UHF Male UHF Female HN Male SC Male Description Hex Head Hex Head Rt Angle, Hex Hd Bulkhead Rt Angle, Outdoor Use Right Angle Right Angle Bulkhead Panel Mount Bulkhead Panel Mount Type Number F4PNMV2-H F4PNMV2-HC F4PNR-H F4PNR-HC F4PNF F4PNF-C F4PNF-BH F4PKM-C F4PKR-C F4PDMV2-C F4PDMV2 F4PDR F4PDR-C F4PDF-C F4PDF F4PDF-BH F4PDF-PM F4PDF-BHC F4PDF-PMC 44ASR 44ASP 44ASU 44ASJ 44SPCW Inner Contact Attachment Solder Captivated Solder Captivated Solder Captivated Solder Captivated Captivated Captivated Solder Solder Captivated Captivated Solder Solder Solder Captivated Captivated Solder Solder Solder Solder Solder Outer Contact Attachment Crush-Flare Crush-Flare Tab-Flare Crush-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Crush-Flare Crush-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Self-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Tab-Flare Plating Code SG SG SG SG SG SG SG SS SS SS SS SS SS SS SS SS SS SS SS BS BS BS BB SG Max. Length in (mm) 2.13 (54.0) 2.13 (54.0) 3.3/1.5 (84/38) 2.8 (71.9)/1.6 (41.5) 2.3 (53.3) 2.3 (53.3) 2.3 (58) 2.0 (50) 2.3/1.5 (57/38) 1.98 (50.2) 2.10 (53.4) 2.4.1.8 (61/46) 2.1/2.0 (53/50) 2.0 (50) 2.0 (50) 2.01 (51.1) 2.01 (51.1) 2.0 (50) 2.0 (50) 3.3 (84) 2.1 (53) 2.3 (58) 2.4 (61) 2.7 (69) Max. Dia. in (mm) 0.94 (23.8) 0.94 (23.8) 0.86 (21.8) 1 (25.7) 0.88 (22.4) 0.88 (22.4) 0.95 (24.1) 0.95 (24.1) 0.95 (24.1) 1.05 (26.7) 1.05 (26.7) 1.4 (35.6) 1.4 (35.6) 1.1 (27.9) 1.1 (27.9) 1.50 (38) 1.26 (32) 1.8 (45.7) 1.3 (33) 1.4 (35.6) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.88 (22.4)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories See page 624 Factory Attached Connectors For factory made cable assemblies and jumper cables, see pages 584-587.
550
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Accessories
Description Type No. Description Type No.
551
HJ4.5-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 200 300 400 450 500 600 700 800 824 894 960 1000 1250 1500 2000 3000 4000* 5000 6000 6600 Attenuation dB/100 ft 0.034 0.048 0.058 0.067 0.152 0.215 0.264 0.343 0.457 0.488 0.508 0.602 0.699 0.863 1.00 1.07 1.13 1.24 1.35 1.45 1.47 1.54 1.60 1.64 1.85 2.04 2.40 3.01 3.55 4.04 4.49 4.75 Attenuation dB/100 m 0.110 0.156 0.192 0.221 0.497 0.706 0.867 1.12 1.50 1.60 1.67 1.98 2.29 2.83 3.29 3.51 3.71 4.09 4.43 4.76 4.85 5.05 5.25 5.37 6.07 6.70 7.86 9.89 11.6 13.3 14.8 15.6 Average Power, kW 40.0 40.0 40.0 35.30 15.64 10.98 8.94 6.90 5.17 4.84 4.65 3.92 3.38 2.73 2.35 2.20 2.09 1.89 1.74 1.62 1.59 1.52 1.47 1.43 1.27 1.16 0.986 0.784 0.665 0.585 0.525 0.496
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 6.6 92 40 0.41 (1.35) 0.23 (0.75) 4000 5500 22.3 (73.2) 0.056 (0.182) Copper Copper 0.875 (22.2) 0.775 (19.7) 0.272 (6.9) 1.51 7 (180) 15 (20) 16 (21.7) 0.40 (0.59) 750 (340) 250 (4.5)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power. VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. * Operation of this cable in the 4250-4400 MHz band is not recommended because of VSWR spikes produced by the dielectric spacing.
552
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male H4.5PNM
Connectors
Interface N Male 7-16 DIN Male Splice Description Type Number H4.5PNM H4.5PDM 85Z Inner Contact Attachment Spring Finger Spring Finger Self-tapping Outer Contact Attachment Self Flare Self Flare Self Flare Plating Code SG SS BB Max. Length in (mm) 2.6 (66) 2.8 (71) 3.1 (79) Max. Dia. in (mm) 1.3 (33) 1.3 (33) 1.6 (41)
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin.
Connector Accessories
Type Number Bulkhead Adapter, for N or UHF Females 26016-2
* Connectors ordered separately. VSWR values are guaranteed for factory fit assemblies and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
553
Accessories
Description Type No. Description Type No.
Snap-in Hangers Kit of 10. For prepunched 3/4" (19 mm) holes on tower member or adapters. Recommended maximum spacing is 3-ft (1 m). For different spacing recommendations, refer to Cable Hanger Spacing, page 593-598. 206706-6 Click-On Hangers Kit of 10. Recommended maximum spacing is 3-ft. Mounting Hardware see page 605 Standard Hoisting Grip L45CLICK 29958
554
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HJ5-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 3000 4000 5000 5200 Attenuation dB/100 ft 0.0250 0.0355 0.0435 0.0503 0.113 0.161 0.198 0.258 0.346 0.369 0.385 0.457 0.494 0.532 0.661 0.772 0.823 0.871 0.883 0.963 1.05 1.13 1.15 1.20 1.25 1.28 1.45 1.61 1.73 1.91 2.07 2.43 2.89 3.32 3.40 Attenuation dB/100 m 0.0822 0.116 0.143 0.165 0.372 0.529 0.651 0.846 1.13 1.21 1.26 1.50 1.62 1.75 2.17 2.53 2.70 2.86 2.90 3.16 3.44 3.71 3.77 3.94 4.11 4.20 4.77 5.29 5.69 6.26 6.79 7.96 9.48 10.9 11.2 Average Power, kW 90.0 78.4 63.9 55.3 24.5 17.3 14.0 10.8 8.05 7.53 7.23 6.09 5.63 5.23 4.21 3.60 3.38 3.19 3.15 2.89 2.65 2.46 2.42 2.31 2.22 2.17 1.91 1.72 1.60 1.46 1.34 1.15 0.963 0.839 0.818
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Out Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 5.2 91.6 90 0.25 (0.82) 0.20 (0.66) 6000 8000 22.2 (72.8) 0.055 (0.180) Copper Copper 1.11 (28.2) 1.01 (25.7) 0.359 (9.1) 2.02 10 (250) 15 (20) 25 (34) 0.54 (0.80) 800 (360) 250 (4.5)
Standard Conditions: For Attenuation. VSWR 1.0, ambient temperature 20C (68F), atmospheric pressure, dry air. For average Power. VSWR 1.0 inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. Contact Andrew for information on operation in the 3050-3200 MHz band.
555
N Female H5PNF
N Female H5NF-T
N Male H5PNM
Connectors
Interface N Male N Male N Female N Female 7-16 DIN Male 7-16 DIN Female 7/8" EIA Flange 7/8" EIA Flange 7/8" EIA Flange 7/8" EIA Flange 1-5/8" EIA Flange UHF Female LC Male End Terminal Splice Description Tunable Tunable Gas Pass Gas Pass, Tunable Gas Barrier Gas Barrier, Tunable Gas Pass/Barrier Type Number H5PNM H5NM-T H5PNF H5NF-T H5PDM H5PDF 75AR 75ART H5MB-014 75AGT H5MPB-110 75AU 75AM 75AT 75AZ Reference* 75AG Inner Contact Attachment Self-tapping Self-tapping Self-tapping Self-tapping Spring Finger Spring Finger Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code SG BB SG BB SS SS BB BB BB BB BS BS BB BB BB Max. Length in (mm) 3.5 (89) 8.5 (216) 3.4 (86) 8.2 (208) 2.8 (71) 2.8 (71) 3.7 (94) 5.9 (150) 3.7 (94) 5.9 (150) 5.2 (132) 3.4 (86) 5.0 (127) 5.1 (130) 4.2 (107) Max. Dia. in (mm) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36) 2.25 (57) 2.25 (57) 2.25 (57) 2.25 (57) 3.5 (89) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin * Previous Type Number.
Connector Accessories
Type Number Connector Reattachment Kit For H5PNF, H5PNM, 75AR, 75PN, 75PW For 75AG, 75AU For 75ART, 75AGT For H5NF-T, 75NT Bulkhead Adapter, for N or UHF Females 90, 7/8" EIA Miter Elbow, includes one inner connector 34767A-3 34767A-5 34767A-44 34767A-18 26016-2 1060A
556
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
VSWR values are guaranteed for factory fit assemblies and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Two Hole: Three Hole: 4" Boots 204679A-2 204679A-18 204679A-15 5" Boots 48939A-1 48939A-2
557
HT5-50
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 3000 4000 5000 5200 Attenuation dB/100 ft 0.0253 0.0360 0.0442 0.0512 0.118 0.171 0.213 0.282 0.389 0.419 0.438 0.532 0.581 0.632 0.813 0.972 1.05 1.12 1.14 1.26 1.40 1.53 1.56 1.65 1.73 1.78 2.08 2.37 2.59 2.91 3.24 3.95 4.91 5.84 6.02 Attenuation dB/100 m 0.0829 0.118 0.145 0.168 0.387 0.561 0.698 0.925 1.28 1.38 1.44 1.75 1.91 2.07 2.67 3.19 3.44 3.69 3.74 4.15 4.59 5.03 5.13 5.42 5.69 5.85 6.84 7.77 8.50 9.56 10.6 13.0 16.1 19.2 19.8 Average Power, kW 90.0 90.0 90.0 90.0 59.2 40.8 32.7 24.7 17.9 16.6 15.9 13.1 11.9 11.0 8.59 7.18 6.65 6.21 6.11 5.52 4.99 4.55 4.47 4.23 4.03 3.92 3.34 2.94 2.20 1.51 1.49 1.46 1.42 1.19 1.16
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Copper Outer Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 1 5.2 92.5 90 0.25 (0.82) 0.20 (0.66) 6000 21.7 (71.2) 0.055 (0.182) Copper Copper Tube 1.01 (25.5) 10 (250) 15 (30) 29 (39.3) 0.45 (0.67) 800 (360) 240 (4.3)
Standard Conditions: For Attenuation. VSWR 1.0, ambient temperature 20C (68F), atmospheric pressure, dry air. For average power, VSWR 1.0 inner temperature 200C (392F), ambient temperature 40C (104F) atmospheric pressure, dry air, no solar loading. Operation of this cable in the 3550-3700 MHz band is not recommended because of VSWR spikes produced by the dielectric section spacing.
558
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Female H5PNF
N Male H5PNM
Connectors
Interface Description Type Number H5PNM H5NF-T H5PDM H5PDF 75AR H5MB-014 75AU 75AM 75AT 75AZ Reference* 75AG Inner Contact Attachment Self-tapping Self-tapping Spring Finger Spring Finger Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code SG BB SS SS BB BB BS BB BB BB Max. Length in (mm) 3.5 (89) 8.2 (208) 2.8 (71) 2.8 (71) 3.7 (94) 3.7 (94) 3.4 (86) 5.0 (127) 5.1 (130) 4.2 (107) Max. Dia. in (mm) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36) 2.25 (57) 2.25 (57) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36)
N Male N Female Tunable 7-16 DIN Male 7-16 DIN Female 7/8" EIA Flange Gas Pass 7/8" EIA Flange Gas Barrier UHF Female LC Male End Terminal Splice
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin * Previous Type Number.
Accessories
Description Type No.
Connector Accessories
Type Number Connector Reattachment Kit For H5PNF, H5PNM, 75AR, 75PN, 75PW For 75AG, 75AU For 75ART, 75AGT For H5NF-T, 75NT Bulkhead Adapter, for N or UHF Females 90, 7/8" EIA Miter Elbow, includes one inner connector 34767A-3 34767A-5 34767A-44 34767A-18 26016-2 1060A
Accessories
Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Two Hole: Three Hole: 4" Boots 204679A-2 204679A-18 204679A-15 5" Boots 48939A-1 48939A-2
559
HJ7-50A
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 2.7 92.1 305 0.22 (0.72) 0.10 (0.33) 11000 10000 22.1 (72.4) 0.055 (0.181) Copper Copper 1.98 (50.3) 1.83 (46.5) 0.713 (18.1) 3.99 20 (510) 15 (30) 30 (40.7) 1.04 (1.55) 750 (340) 175 (3.1)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
560
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Female H7PNF
Connectors
Interface N Male N Female N Female 7-16 DIN Male 7-16 DIN Female 1-5/8" EIA Flange 1-5/8" EIA Flange 7/8" EIA Flange 7/8" EIA Flange 7/8" EIA Flange 7/8" EIA Flange LC Female End Terminal Splice Description Tunable Tunable Gas Pass Gas Block Gas Pass Gas Pass, Tunable Gas Block Gas Block, Tunable Type Number H7NM-T H7PNF H7NF-T H7PDM H7PDF 87R 87G H7MP-014 87ST H7MB-014 87SGT 87L 87T 87Z Reference* 87S 87SG Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB SG BB SS SS BS BS BS BS BS BS BB BB BB Max. Length in (mm) 11.6 (295) 4.1 (104) 11.4 (290) 4.2 (107) 4.2 (107) 4.8 (122) 5.7 (145) 5.6 (142) 11.8 (300) 5.6 (142) 12.2 (310) 4.9 (124) 7.0 (178) 5.9 (150) Max. Dia. in (mm) 2.4 (61) 2.4 (61) 2.4 (61) 2.7 (69) 2.7 (69) 3.5 (89) 3.5 (89) 2.4 (61) 2.4 (61) 2.4 (61) 2.4 (61) 2.4 (61) 2.4 (61) 2.4 (61)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin (inner connector), SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin * Previous Type Number. Includes inner.
Connector Accessories
Type Number Connector Reattachment Kit For 87G, 87R For H7PNF, 87PN, H7MP-014, H7MB-014 For 87SGT, 87ST For H7NF-T, H7NM-T, 87NT, 87WT For 87Z 7/8" EIA Gas Barrier 1-5/8" EIA Gas Barrier 1-5/8" EIA End Terminal, for strap connection to center conductor, includes inner connector. Use with 87R 1-5/8" Inner Connector, with anchor bead 1-5/8" EIA 90 Miter Elbow, includes one inner connector 34767A-6 34767A-7 34767A-20 34767A-19 34767A-13 1260A 1261B
561
* Tunable connector may be used. VSWR values are guaranteed for factory fit assemblies and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: 4" Boots 204679A-4 5" Boots 48939A-4
562
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
HJ12-50
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimension (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 2.3 93.1 425 0.17 (0.56) 0.075 (0.25) 13000 10000 21.8 (71.5) 0.055 (0.180) Copper Copper 2.38 (60.4) 2.23 (56.6) 0.890 (22.6) 4.96 22 (560) 15 (50) 55 (75) 1.16 (1.73) 980 (445) 145 (2.6)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
563
N Female H12PNF
Connectors
Interface N Female 7-16 DIN Male 3-1/8" EIA Flange 3-1/8" EIA Flange 1-5/8" EIA Flange 7/8" EIA Flange Splice Description Gas Pass, Female Gas Barrier, Female Gas Pass, Male Gas Pass, Male Type Number H12PNF H12PDM 82RF 82GF 82R 82S 82Z Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code SG SS BB BB BB BB BB Max. Length in (mm) 4.4 (112) 4.5 (114) 6.9 (175) 6.9 (175) 4.8 (122) 5.7 (145) 5.9 (150) Max. Dia. in (mm) 2.8 (71) 3.1 (79) 5.2 5.2 3.5 (89) 2.8 (71) 3.4 (86)
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin, SS - Silver Plated Body and Pin
Connector Accessories
Type Number Connector Reattachment Kit For H12PNF, 82PN For 82R For 82RF For 82GF 1-5/8" EIA Gas Barrier 1-5/8" EIA End Terminal, for strap connection to center conductor, includes inner connector. Use with 82R 1-5/8" Inner Connector, with anchor bead 3-1/8" Inner Connector, with anchor bead 3-1/8" EIA 90 Miter Elbow, includes inner conductor 1-5/8" EIA 90 Miter Elbow 7/8" EIA 90 Miter Elbow 34767A-46 34767A-47 34767A-49 34767A-50 1261B
564
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
VSWR values are guaranteed for factory fit assemblies and are typical for field cut lengths. If two different connector interfaces are selected, the higher VSWR value is guaranteed.
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: 4" Boots 204679A-8 5" Boots 48939A-9
565
HJ8-50B
Description Type No.
HJ8-50B
209227
42141* 27591-6
0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1640
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 1.64 93.3 640 0.15 (0.49) 0.07 (0.23) 16000 10000 21.7 (71.2) 0.055 (0.18) Copper Copper 3.01 (76.6) 2.85 (72.4) 1.14 (29.0) 6.35 30 (760) 15 (25) 30 (41) 1.78 (2.6) 750 (340) 175 (3.1)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 121C (250F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. * These values are for 27591-6 cable with polyethylene dielectric available on special order.
566
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connectors
Interface 3-1/8" EIA Flange 3-1/8" EIA Flange 3-1/8" EIA Flange 3-1/8" EIA Flange 1-5/8" EIA Flange Splice Description Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Gas Pass, inner connector Type Number H8MP-302 H8MB-302 H8FP-302 H8FB-302 78AS 78BZ Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB BB BB BB BB BB Max. Length in (mm) 8.06 (204.7) 8.06 (204.7) 6.0 (152.4) 6.0 (152.4) 3.9 (99) 6.1 (155) Max. Dia. in (mm) 5.19 (131.7) 5.19 (131.7) 5.19 (131.7) 5.19 (131.7) 3.6 (91) 5.3 (135)
Plating Codes: BB - Brass Body and Pin ** Universal application - designed so that all connector variations of same flange size can be accommodated by modifying this connector, using instructions provided.
Connector Accessories
Type Number Connector Reattachment Kit For H8MP-302, H8MB-302, H8FP-302, H8FB-302 34767A-60 For 78AGF, 78ARM, 78ARF, 78AGM, 78AS 34767A-10 For 78BZ 34767A-30 3-1/8" EIA End Terminal, for strap connection to center conductor, includes inner connector. Use with H8FP-302. 2062 3-1/8" Inner Connector, with anchor bead ACX350-20 1-5/8" Inner Conductor, with anchor bead 34660 3-1/8" EIA 90 Miter Elbow, includes one inner connector ACX350-10SE 1-5/8" EIA 90 Miter Elbow ACX150-10SE 1-5/8" Gas Barrier 1261B
Accessories
Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: 4" Boots 204679A-9 5" Boots 48939A-10
567
HJ11-50
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 1.22 92 1100 0.11 (0.36) 0.04 (0.13) 21000 10000 22.0 (72.2) 0.055 (0.18) Copper Copper 4.00 (102) 3.84 (97) 1.55 (39.4) 8.55 40 (1015) 15 (30) 191 (259) 2.50 (3.72) 900 (408) 280 (5.0)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 121C (250F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
568
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connectors
Interface 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange 4-1/2" IEC Flange 4-1/2" IEC Flange 4-1/2" IEC Flange 4-1/2" IEC Flange 3-1/8" EIA Flange 3-1/8" EIA Flange 3-1/8" EIA Flange 3-1/8" EIA Flange Splice Description Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Type Number H11MP-602 H11MB-602 H11FP-602 H11FB-602 H11MP-M408 H11MB-M408 H11FP-M408 H11FB-M408 H11MP-302 H11MB-302 H11FP-302 H11FB-302 81Z Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB BB BB BB BB BB BB BB BB BB BB BB BB Max. Length in (mm) 11.3 (288) 11.3 (288) 8.5 (216) 8.5 (216) 9.4 (240) 9.4 (240) 7.0 (178) 7.0 (178) 9.1 (230) 9.1 (230) 7.0 (178) 7.0 (178) 7.0 (178) Max. Dia. in (mm) 8.13 (207) 8.13 (207) 8.13 (207) 8.13 (207) 6.36 (162) 6.36 (162) 6.36 (162) 6.36 (162) 5.2 (132) 5.2 (132) 5.2 (132) 5.2 (132) 6.0 (152)
Plating Codes: BB - Brass Body and Pin ** Universal application - designed so that all connector variations of same flange size can be accommodated by modifying this connector, using instructions provided.
Connector Accessories
Type Number Connector Reattachment Kit For H11( )-602 34767A-57 For H11( )-M408 34767A-58 For H11( )-302 34767A-59 For 81RF 34767A-15 For 81GF 34767A-16 For 42826 34767A-40 For 42896 34767A-41 For 81Z 34767A-17 3-1/8" End Terminal, for strap connection to center conductor, includes inner connector. Use with H11FB-302. 2062 6-1/8" End Terminal, for strap connection to center conductor, includes inner connector. Use with H11FB-602. RLA650-80 6-1/8" EIA Inner Connector, with anchor bead ACX650-20 3-1/8" EIA Inner Connector, with anchor bead ACX350-20 4-1/2" IEC Inner Connector, with anchor bead 241252 3-1/8" EIA 90 Mitre Elbow, includes one inner connector ACX350-10SE Reducer, 3-1/8" to 1-5/8", captivated 3-1/8" inner connector 1861 6-1/8" EIA 90 Miter Elbow, includes one inner connector ACX650B-10SE
Accessories
Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
569
HJ9-50
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 50 0.5 0.96 93.1 1890 0.1 (0.3) 0.04 (0.13) 27500 12000 21.7 (71.2) 0.055 (0.18) Copper Copper 5.20 (133) 5.00 (127) 2.02 (51.3) 11.3 50 (1270) 15 (30) 200 (271) 3.3 (4.9) 1000 (454) 275 (4.9)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
570
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connectors
Interface 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange 4-1/2" IEC Flange 4-1/2" IEC Flange 4-1/2" IEC Flange 4-1/2" IEC Flange Splice Description Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Type Number H9MP-602 H9MB-602 H9FP-602 H9FB-602 H9MP-M408 H9MB-M408 H9FP-M408 H9FB-M408 79AZ Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB BB BB BB BB BB BB BB BB Max. Length in (mm) 12.3 (313) 12.3 (313) 9.5 (241) 9.5 (241) 10.7 (272) 10.7 (272) 8.3 (211) 8.3 (211) 6.2 (157) Max. Dia. in (mm) 8.13 (207) 8.13 (207) 8.13 (207) 8.13 (207) 6.6 (168) 6.6 (168) 6.6 (168) 6.6 (168) 7.6 (193)
Plating Codes: BB - Brass Body and Pin ** Universal application - designed so that all connector variations of same flange size can be accommodated by modifying this connector, using instructions provided.
Connector Accessories
Type Number Connector Reattachment Kit For 79AG, 79AR 34767A-45 For H9( )-602 34767A-55 For H9( )-M408 34767A-56 For 79AZ 34767A-31 6-1/8" End Terminal, for strap connection to center conductor, includes inner connector. Use with H9FB-602. RLA650-80 6-1/8" EIA Inner Connector, with anchor bead ACX650-20 4-1/2" IEC Inner Connector, with anchor bead 241252 Reducer, 6-1/8" to 3-1/8" includes two inner connectors RLA650-350 6-1/8" EIA 90 Miter Elbow, includes one inner connector ACX650-10SE
Accessories
Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
571
HJ9HP-50
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Outer Conductor, in (mm) Diameter Inner Conductor, in (mm) Nominal Inside Transverse Dimensions, (cm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flate Plate Crush Strength, lb/in (kg/mm) 50 0.5 0.96 96.4 1690 0.1 (0.33) 0.04 (0.13) 26000 12000 20.8 (68.1) 0.054 (0.176) Copper Copper 5.20 (132) 5.00 (127) 2.07 (52.7) 11.3 50 (1270) 15 (30) 200 (271) 3.4 (4.9) 1000 (454) 240 (4.29)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 150C (302F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading.
572
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connectors
Interface 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange 6-1/8" EIA Flange Splice Description Gas pass, includes inner connector Gas block, includes inner connector** Gas pass, no inner connector Gas block, no inner connector Type Number H9HPMP-602 H9HPMB-602 H9HPFP-602 H9HPFB-602 H9HPZ Inner Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB BB BB BB BB Max. Length in (mm) 12.4 (315) 12.4 (315) 9.5 (242) 9.5 (242) 6.19 (158) Max. Dia. in (mm) 8.13 (207) 8.13 (207) 8.13 (207) 8.13 (207) 7.57 (193)
Plating Codes: BB - Brass Body and Pin ** Universal application - designed so that all connector variations of same flange size can be accommodated by modifying this connector, using instructions provided.
Connector Accessories
Type Number Connector Reattachment Kit For H9 ( ) HP-602 34767A-55 For H9HPZ 34767A-31 6-1/8" End Terminal, for strap connection to center conductor, includes inner connector. Use with H9HPFB-602. RLA650-80 6-1/8" EIA Inner Connector, with anchor bead ACX650-20 4-1/2" IEC Inner Connector, with anchor bead 241252 Reducer, 6-1/8" to 3-1/8" includes two inner connectors RLA650-350 6-1/8" EIA 90 Miter Elbow, includes one inner connector ACX650B-10SE
Accessories
Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
573
FSJ1-75
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft. (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 75 3 22.0 78 6.7 15 (49.2) 1.8 (5.9) 2000 5000 17.4 (57.0) 0.098 (0.321) Copper Copper-Clad Steel 0.29 (7.4) 0.25 (6.4) 1 (25) 15 (50) 0.5 (0.68) 0.046 (0.068) 150 (68) 100 (1.8)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 40C (104F), inner conductor temperature 1000C (212F), no solar loading.
574
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male F1NM-7550
Connectors
Interface N Male N Male N Female BNC Male UHF Male TNC Male CATV Type F Description 50 Ohm Mating Pin 70 Ohm Mating Pin 70 Ohm Mating Pin 50 Ohm Mating Pin 50 Ohm Mating Pin 50 Ohm Mating Pin Type Number F1NM-7550-H F1NM-7570 F1NF-7570 49651 41SP 41SWT-75 F1FM-75 Inner Contact Attachment Solder Solder Solder Solder Solder Solder Captivated Outer Contact Attachment Solder Solder Solder Tab Flare Tab Flare Tab Flare Crimp Plating Code SG NS BS BS BB SS BB Max. Length in (mm) 1.85 (47) 2.2 (56) 1.9 (48) 1.2 (30) 1.5 (38) 1.1 (28) 1.42 (36) Max. Dia. in (mm) 0.92 (23.4) 0.79 (20.1) 0.70 (17.8) 0.56 (14.2) 0.72 (18.3) 0.63 (16.0) 0.56 (14.2)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin, NS - Nickel Plated Body and Silver Plated Pin, SS - Silver Plated Body and Pin, SG - Silver Plated Body and Gold Plated Pin
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots 4" Boots Three Hole: 204679A-17
575
FSJ4-75A
Description Type No.
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor in (mm) Diameter Inner Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 75 2 11.5 81 10.0 1.50 (4.9) 1.00 (3.28) 2500 5000 16.7 (54.9) 0.094 (0.309) Copper Copper 0.52 (13.2) 0.48 (12.2) 0.118 (3.0) 1.25 (32) 20 (50) 2.0 (2.7) 0.14 (0.21) 140 (63.5) 105 (1.9)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
576
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male F4NM-7570
N Female F4NF-7570
Connectors
Interface N Male N Male N Male N Female N Female UHF Male UHF Female CATV Type F Description 50 Ohm Mating Pin 70 Ohm Mating Pin 50 Ohm Mating Pin, Right Angle 50 Ohm Mating Pin 70 Ohm Mating Pin 50 Ohm Mating Pin 50 Ohm Mating Pin Type Number F4NM-7550 F4NM-7570 F4NR-7550 F4NF-7550 F4NF-7570 44ASP-75 44ASU-75 44ASCM Inner Contact Attachment Solder Solder Solder Solder Solder Solder Solder Solder Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Plating Code BB BB BB BS BS BS BS BB Max. Length in (mm) 2.3 (58) 2.2 (56) 3.3/1.5 (84/38) 2.2 (56) 2.1 (53) 2.3 (58) 2.3 (58) 2.5 (64) Max. Dia. in (mm) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3) 0.84 (21.3)
Plating Codes: BB - Brass Body and Pin, BS - Brass Body and Silver Plated Pin.
Accessories
Description Type No. Description Type No.
WS-L5F4 WS-L6F4 WS-L7F4 241474-4 241475-13 241475-9 241475-5A 241475-8 241548-8 221213
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Three Hole: Four Hole 4" Boots 204679A-5 204679A-7 204679A-16 5" Boots 48939A-6 48939A-8 48939A-17
577
LDF4-75A
Description Type No.
Characteristics
Electrical Impedance, ohms 75 3 Maximum Frequency, GHz 10 Velocity, percent 88 Peak Power Rating, kW 26 dc Resistance, ohms/1000 ft (1000 m) Inner 1.15 (3.77) Outer 0.58 (1.90) dc Breakdown, volts 4000 Jacket Spark, volts RMS 8000 Capacitance, pF/ft (m) 15.4 (50.5) Inductance, H/ft (m) 0.087 (0.284) Mechanical Outer Conductor Copper Inner Conductor Copper-Clad Aluminum Diameter over Jacket, in (mm) 0.63 (16) Diameter over Copper Outer Conductor, in (mm) 0.55 (14) Minimum Bending Radius, in (mm) 5 (125) Number of Bends, minimum (typical) 15 (40) Bending Moment, lb-ft (Nm) 2.8 (3.8) Cable Weight, lb/ft (kg/m) 0.14 (0.21) Tensile Strength, lb (kg) 200 (90.7) Flat Plate Crush Strength, lb/in (kg/mm) 110 (2.0)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
578
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Male L4NM-7570
N Female L4NF-7570
Connectors
Interface N Male N Male N Male Description 50 Ohm Mating Pin 70 Ohm Mating Pin 50 Ohm Mating Pin, Right Angle 50 Ohm Mating Pin 70 Ohm Mating Pin Type Number L4NM-7550-H L4NM-7570-H L4NR-7550 L4NF-7550 L4NF-7570 L44P-75 L44U-75 48070 L44Z-75 Inner Contact Attachment Solder Solder Solder Solder Solder Solder Solder Solder Outer Contact Attachment Self Flare Self Flare Self Flare Self Flare Self Flare Self Flare Self Flare Self Flare Self Flare Plating Code BB BB NB BB BB BB BB BB BB Max. Length in (mm) 2.5 (64) 2.5 (64) 3.2/1.5 (81/38) 2.5 (64) 2.3 (58) 2.3 (58) 2.3 (58) 2.0 (50) 3.2 (81) Max. Dia. in (mm) 0.94 (23.8) 0.94 (23.8) 0.95 (24.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 0.91 (23.1) 1.1 (27.9)
N Female N Female UHF Male UHF Female CATV Equipment Housing Splice
Plating Codes: BB - Brass Body and Pin, NB - Nickel Plated Body and Brass Pin.
Accessories
Description Type No. Description Type No.
SureGround Plus Grounding Kit with weatherproofing boot Factory attached one-hole lug, 600 mm (24") lead SGPL4-06B1 Factory attached two-hole lug, 600 mm (24") lead SGPL4-06B2 Field attached two-hole lug, 1500 mm (59") lead SGPL4-15B4
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Three Hole: Four Hole 4" Boots 204679A-5 204679A-7 204679A-16 5" Boots 48939A-6 48939A-8 48939A-17
579
LDF5-75
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 1800 2000 2100 2200 2300 3000 3400 4000 5000 5300 Attenuation dB/100 ft 0.024 0.034 0.042 0.049 0.111 0.158 0.195 0.254 0.342 0.366 0.382 0.455 0.493 0.532 0.665 0.781 0.834 0.885 0.897 0.982 1.07 1.16 1.18 1.24 1.29 1.32 1.51 1.69 1.82 1.88 2.01 2.07 2.13 2.19 2.59 2.81 3.12 3.62 3.76 Attenuation dB/100 m 0.080 0.113 0.139 0.160 0.363 0.518 0.639 0.833 1.12 1.20 1.25 1.49 1.62 1.75 2.18 2.56 2.74 2.90 2.94 3.22 3.52 3.81 3.87 4.06 4.24 4.34 4.95 5.53 5.97 6.18 6.60 6.80 7.00 7.20 8.51 9.23 10.3 11.9 12.3 Average Power, kW 45.2 31.9 26.0 22.5 9.94 6.96 5.65 4.33 3.21 3.00 2.88 2.42 2.23 2.07 1.65 1.41 1.32 1.24 1.23 1.12 1.03 0.949 0.933 0.889 0.853 0.832 0.729 0.653 0.605 0.584 0.548 0.531 0.516 0.502 0.425 0.392 0.353 0.304 0.293
Characteristics
Electrical Impedance, ohms 75 3 Maximum Frequency, GHz 5.3 Velocity, percent 89 Peak Power Rating, kW70 dc Resistance, ohms/1000 ft (1000 m) Inner 0.34 (1.11) Outer 0.32 (1.05) dc Breakdown, volts 6500 Jacket Spark, volts RMS 8000 Capacitance, pF/ft (m) 15.1 (49.5) Inductance, H/ft (m) 0.087 (0.284) Mechanical Outer Conductor Copper Inner Conductor Copper-clad aluminum Diameter over Jacket, in (mm) 1.082 (27.48) Diameter over Copper Outer Conductor, in (mm) 0.980 (24.89) Minimum Bending Radius, in (mm) 10 (250) Number of Bends, minimum (typical) 15 (40) Bending Moment, lb-ft (Nm) 12 (16.3) Cable Weight, lb/ft (kg/m) 0.30 (0.45) Tensile Strength, lb (kg) 325 (147) Flat Plate Crush Strength, lb/in (kg/mm) 80 (1.4)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F). For Average Power, VSWR 1.0, ambient temperature 40C (104F), inner conductor temperature 100C (212F), no solar loading.
580
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Female L5PNF-7570-BH
Connectors
Interface N Male N Male N Female N Female Description 70-Ohm Mating Pin 50-Ohm Mating Pin 70-Ohm Mating Pin 70-Ohm Mating Pin Bulkhead Type Number L5PNM-7570 L5PNM-7550 L5PNF-7570 L5PNF-7570-BH Inner Contact Attachment Solder Solder Solder Solder Outer Contact Attachment Self-Flare Self-Flare Self-Flare Self Flare Plating Code SG SG SG BB Max. Length in (mm) 2.9 (74) 3.1 (78.7) 2.9 (74) 3.1 (78.7) Max. Dia. in (mm) 1.36 (34.5) 1.36 (34.5) 1.36 (34.5) 1.36 (34.5)
Plating Codes: BB - Brass Body and Pin, SG - Silver Plated Body and Gold Plated Pin
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Two Hole: Three Hole: 4" Boots 204679A-2 204679A-18 204679A-15 5" Boots 48939A-1 48939A-2
581
HJ5-75
Attenuation and Average Power Ratings
Description Type No. Frequency MHz 0.5 1 1.5 2 10 20 30 50 88 100 108 150 174 200 300 400 450 500 512 600 700 800 824 894 960 1000 1250 1500 1700 2000 2300 3000 4000 5000 5600 Attenuation dB/100 ft 0.0250 0.0355 0.0436 0.0505 0.116 0.168 0.209 0.272 0.363 0.388 0.404 0.480 0.517 0.555 0.687 0.800 0.850 0.898 0.909 0.988 1.07 1.15 1.17 1.22 1.26 1.29 1.46 1.61 1.74 1.92 2.10 2.49 3.00 3.40 3.65 Attenuation dB/100 m 0.0819 0.116 0.143 0.166 0.381 0.552 0.686 0.892 1.19 1.27 1.33 1.58 1.70 1.82 2.26 2.63 2.79 2.95 2.98 3.24 3.51 3.77 3.82 3.99 4.14 4.23 4.78 5.28 5.70 6.30 6.89 8.18 9.84 11.2 12.0 Average Power, kW 60.0 54.7 44.6 38.5 16.4 11.4 9.31 7.13 5.34 5.01 4.80 4.02 3.71 3.45 2.79 2.40 2.25 2.14 2.10 1.93 1.78 1.66 1.64 1.57 1.52 1.49 1.31 1.17 1.08 0.977 0.898 0.763 0.640 0.565 0.526
Characteristics
Electrical Impedance, ohms Maximum Frequency, GHz Velocity, percent Peak Power Rating, kW dc Resistance, ohms/1000 ft (1000 m) Inner Outer dc Breakdown, volts Jacket Spark, volts RMS Capacitance, pF/ft (m) Inductance, H/ft (m) Mechanical Outer Conductor Inner Conductor Diameter over Jacket, in (mm) Diameter over Copper Outer Conductor, in (mm) Minimum Bending Radius, in (mm) Number of Bends, minimum (typical) Bending Moment, lb-ft (Nm) Cable Weight, lb/ft (kg/m) Tensile Strength, lb (kg) Flat Plate Crush Strength, lb/in (kg/mm) 75 1 5.6 90 60 0.25 (0.82) 0.20 (0.66) 6000 8000 15.1 (49.4) 0.085 (0.278) Copper Copper 1.11 (28.2) 1.01 (25.7) 10 (250) 15 (20) 25 (34) 0.52 (0.79) 800 (360) 250 (4.5)
Standard Conditions: For Attenuation. VSWR 1.0 ambient temperature 20C (68F), atmospheric pressure, dry air. For Average Power, VSWR 1.0, inner temperature 100C (212F), ambient temperature 40C (104F), atmospheric pressure, dry air, no solar loading. Operation of this cable in the 3500-3650 MHz band is not recommended because of VSWR spikes produced by the dielectric section spacing.
582
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
N Female H5NF-7550
N Male H5NM-7550
Connectors
Interface N Male N Female 7/8" EIA Flange UHF Female LC Male End Terminal Splice
Plating Codes:
Description 50 Ohm Mating Pin 50 Ohm Mating Pin Gas Pass 50 Ohm Mating Pin 50 Ohm Mating Pin
Inner Contact Attachment Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping Self-tapping
Outer Contact Attachment Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare Tab Flare
Plating Code BB BB BB BB BB BB BB
Max. Length in (mm) 3.5 (89) 3.9 (99) 4.3 (109) 4.3 (109) 5.0 (127) 5.8 (147) 4.2 (107)
Max. Dia. in (mm) 1.4 (36) 1.4 (36) 2.25 (57) 1.4 (36) 1.4 (36) 1.4 (36) 1.4 (36)
Accessories
Description Type No. Description Type No.
Entry Systems For entry systems offerings see pages 619, 620.
Standard Cable Entry Boots One Hole: Two Hole: Three Hole: 4" Boots 204679A-2 204679A-18 204679A-15 5" Boots 48939A-1 48939A-2
583
SureFle
TM
Andrew has state-of-the-art cable assembly facilities all over the world. You no longer have to deal with expensive and labor intensive cable preparation and connector attachment on site. Andrew will do it for you. Our factory automated processes allow us to produce cable assemblies that will meet your specifications, your delivery requirements, and your budget. HELIAX cable assemblies are ideal for rack-to-rack and radio OEM applications. They are also commonly used for connecting antennas to transmission lines and transmission lines to radios. Here are the advantages of the Andrew factory made cable assembly program: Competitive pricing. Low attachment charges. Guaranteed quality. Assemblies are 100% tested prior to shipment and include a ten year warranty. Fast delivery. Global manufacturing and inventory. Complete product offering. Any cable, any length, any connector. Low VSWR assemblies. For high performance applications.
584
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Andrew SureFlex cable assemblies are ideal for wireless systems such as PCS, cellular, and paging.
F4-PNMNM-3
Connectors
L4P10-PNMNM-6
Connectors
F4A-PNMNM-3
Connectors
L4P10A-PNMNM-6
Connectors
585
586
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
EFX2P-50-41 Low VSWR Cable (1.7-2.3 GHz), see page 490 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male EFX2P41A-PNMNM-(*) EFX2P41A-PNMDM-(*) EFX2P41A-PDMDM-(*)
EFX2P-50-42 Low VSWR Cable (0.806-0.960 and 1.7-2.3 GHz), see page 490 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male EFX2P42A-PNMNM-(*) EFX2P42A-PNMDM-(*) EFX2P42A-PDMDM-(*)
FSJ4P-50B-40 Low VSWR Cable (0.806-0.960 GHz), see page 487 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male F4P40A-PNMNM-(*) F4P40A-PNMDM-(*) F4P40A-PDMDM-(*)
FSJ4P-50B-41 Low VSWR Cable (1.7-2.3 GHz), see page 487 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male F4P41A-PNMNM-(*) F4P41A-PNMDM-(*) F4P41A-PDMDM-(*)
FSJ4P-50B-42 Low VSWR Cable (0.806-0.960 and 1.7-2.3 GHz), see page 487 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male F4P42A-PNMNM-(*) F4P42A-PNMDM-(*) F4P42A-PDMDM-(*)
LDF4P-50A-40 Low VSWR Cable (0.806-0.960 GHz), see page 498 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male L4P40A-PNMNM-(*) L4P40A-PNMDM-(*) L4P40A-PDMDM-(*)
LDF4P-50A-41 Low VSWR Cable (1.7-2.3 GHz), see page 498 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male L4P41A-PNMNM-(*) L4P41A-PNMDM-(*) L4P41A-PDMDM-(*)
LDF4P-50A-42 Low VSWR Cable (0.806-0.960 and 1.7-2.3 GHz), see page 498 for specifications. N Male/N Male N Male/7-16 DIN Male 7-16 DIN Male/7-16 DIN Male L4P42A-PNMNM-(*) L4P42A-PNMDM-(*) L4P42A-PDMDM-(*)
* Insert length in feet or use M suffix to designate meters. For example, -3 = 3 feet, -2M = 2 meters, and -1M5 = 1.5 meters.
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 5/01
587
1500
800
1000
600
400
500
200
0 FSJ1 -500
LDF2
ETS1 0
-500
-1000
-600
-1500 -40
-20
20
40
60
80
-1500 -40
-20
20
40
60
80
-800 -40
-20
20
40
60
80
TEMPERATURE (C)
TEMPERATURE (C)
TEMPERATURE (C)
Figure 1
Figure 2
588
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
The foam dielectric in HELIAX cables is bonded to the center conductor, while the outer conductor corrugations mechanically lock the outer conductor to the dielectric. This locking results in excellent stability. Typical phase change with bending data for HELIAX coaxial cables is given below:
Sample Calculation Using the formula above, the change in phase for a system operating at 10 GHz using a 12 ft FSJ4-50B superflexible HELIAX cable over a temperature range of -40 to 80C (-40 to 176F) is calculated as follows: Phase Change = = 3.66 x 10-7 (400) x 12 x 104 ________________________________ 0.81 21.69 maximum phase change
Phase change with bending is not as repeatable or predictable as phase change with temperature. Results obtained will vary depending on exactly how the cable is bent. The above numbers are intended as a guide to the order of magnitude of change to be expected during installation if bending is required.
800
800
800
400
400 ETS1
600
600
600
400
200
200
200
0 FT4
-200
-400
ETS2
-600
-600
-800 -40
-20
20
40
60
80
-800 -40
-20
20
40
60
80
-800 -40
-20
20
40
60
80
TEMPERATURE (C)
TEMPERATURE (C)
TEMPERATURE (C)
Figure 4 Electrical Length Change vs. Temperature LDF1-50, LDF2-50, LDF4-50A, LDF5-50A
589
Delay Line Cut to Electrical 42394-133 Length 0.1 ns tolerance (36 /GHz) Delay Line, Precision Tolerence deg/GHz (ns) Phase Matched 0.1 ns (36 /GHz) Precision Phase Matched deg/GHz (ns) Characteristics Velocity 2% ft/ns (m/ns) 2%* Phase/Temp Coefficient over temp. range -22 to + 104 F (-30 to +40C) PPM/ F (PPM/ C) 84 0.83 (0.25) -4 to +5 (-7 to +9) 42394-333 1.906 (0.0053) 42394-33 42394-233 1.906 (0.0053)
42394-324 42394-350 42394-322 2.222 (0.0062) 2.56 (0.0072) 2.946 (0.0082) 42394-24 42394-50 42394-22
* For delay lines, the approximate length can be determined by multiplying delay in nanoseconds by the ft/ns factor for the appropriate cable type.
590
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Two levels of cutting accuracy are available for both delay lines and phase matched assemblies: Standard Cutting Accuracy. 0.1 nanoseconds or 36/GHz. This cutting accuracy is not available for some combinations of test frequency and cable assembly lengths.
Precision Cutting Accuracy. Tolerance per table below. This varies by cable type and is based on one half of the corrugation pitch of the cable. This is as close as the cables can be fit on a production basis. This cutting accuracy is not available for some combinations of test frequency and cable assembly lengths.
Delay Line Cut to Electrical 42394-146 Length 0.1 ns tolerance (36 /GHz) Delay Line, Precision Tolerence deg/GHz (ns) Phase Matched 0.1 ns (36 /GHz) Precision Phase Matched deg/GHz (ns) Characteristics Velocity 2% ft/ns (m/ns) 2%* Phase/Temp Coefficient over temp. range -22 to + 104 F (-30 to +40C) PPM/ F (PPM/ C) 82 0.81 (0.25) -9 to +6 (-16 to +10) 42394-346 1.935 (0.0054) 42394-46 42394-246 1.935 (0.0054)
92.1
93.3
* For delay lines, the approximate length can be determined by multiplying delay in nanoseconds by the ft/ns factor for the appropriate cable type.
591
System Timing
Andrew GPS Antenna Kits Speed Installation, Simplify Ordering
Obtain a complete GPS antenna system packaged in a single comprehensive kit. The GPS Antenna System Kit features everything required to establish GPS capabilities for PCS applications. This weatherproof system is designed for outdoor use. It has been tested to meet the following specifications:
Test Thermal shock Moisture resistance Test Specifications MIL-STD-202, method 107, condition A-1, -55OC to +85OC IEC 529, Class IPX4S
Kits Include: GPS antenna integrated with a 26 dB low-noise amplifier with a Type N female connector. A 5-volt dc bias is required, via the center conductor, to power the integrated low-noise pre-amplifier. HELIAX connectors. (1/2" LDF4, 1/2" FSJ4 or 7/8" LDF5 HELIAX cable is ordered separately to length) HELIAX cable hangers, grounding kit, and 3M Cold Shrink self-applicating weatherproofing kit.. Antenna mounting plate and mast shroud.
Ordering Information GPS-KIT12 GPS Antenna Kit for 1/2 LDF4 HELIAX Cable GPS-KITF4 GPS Antenna Kit for 1/2 FSJ4 HELIAX Cable GPS-KIT78 GPS Antenna Kit for 7/8 LDF5 HELIAX Cable
592
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
GH = Gust Response Factor = (see EIA-222) Cf = Structure Force Coefficient (1.2 for cable) Ap = Projected Area (Cable Diameter x Hanger Spacing) Combining the above variables, we see that the force, applied to a hanger due to wind loading, is equal to the following: F = Wind Load Applied to Hanger = 0.00256 (Z/33)0.286 (V)2 Cf GH (Cable Diameter x Hanger Spacing)
From the above equations we can see that the velocity pressure exposure coefficient and the gust response factor introduce some height dependence when considering the amount of force subjected to an individual hanger.
593
The maximum spacing recommendations assume that all hangers are properly installed and tightened. Recommendations for a 150 ft (46 m) tower with 125 mph (200 km/h) wind speed and 1/2" radial ice (typical conditions) are highlighted in red. See Hanger Spacing Considerations, page 593 for further information. Standard Hangers Recommended Maximum Hanger Spacing
Cable Size Wind Speed: Radial Ice: 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" 2-1/4" 3" 4" 5" 5" Wind Speed: Radial Ice: 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" 2-1/4" 3" 4" 5" 5" LDF4-50A LDF4-75A HL4RP-50 HJ4-50 HLT4-50 HT4-50 HST4-50 HS4RP-50 FSJ4-50B FSJ4-75A LDF4.5-50 HJ4.5-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 LDF6-50 LDF7-50A HJ7-50A LDF12-50 HJ12-50 HJ8-50B HJ11-50B HJ9HP-50 HJ9-50 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 42396A-9 42396A-9 42396A-5 42396A-5 42396A-5 42396A-5 42396A-1 42396A-2 42396A-2 42395A-4 42396A-4 31766A-11 31766A-10 33598-5 33598-5 LDF4-50A LDF4-75A HL4RP-50 HJ4-50 HLT4-50 HT4-50 HST4-50 HS4RP-50 FSJ4-50B FSJ4-75A LDF4.5-50 HJ4.5-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 LDF6-50 LDF7-50A HJ7-50A LDF12-50 HJ12-50 HJ8-50B HJ11-50B HJ9HP-50 HJ9-50 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 43211A 42396A-9 42396A-9 42396A-5 42396A-5 42396A-5 42396A-5 42396A-1 42396A-2 42396A-2 42395A-4 42396A-4 31766A-11 31766A-10 33598-5 33598-5 Cable Type Number Hanger Type Number No Ice 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) No Ice 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) Recommended Maximum Hanger Spacing, feet (meters) 85 mph (137 km/h) 1/2" (13 mm) 1" (25 mm) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) No Ice 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) No Ice 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 100 mph (160 km/h) 1/2" (13 mm) 1" (25 mm) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
125 mph (200 km/h) 1/2" (13 mm) 1" (25 mm) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
150 mph (240 km/h) 1/2" (13 mm) 1" (25 mm) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 1 (0.3) 3 (0.9) 3 (0.9) 2 (0.6) 2 (0.6) 2 (0.6) 2 (0.6) 3 (0.9) 2 (0.6) 2 (0.6) 3 (0.9) 3 (0.9) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simutaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
594
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
The maximum spacing recommendations assume that all hangers are properly installed and tightened. Recommendations for a 150 ft (46 m) tower with 125 mph (200 km/h) wind speed and 1/2" radial ice (typical conditions) are highlighted in red. See Hanger Spacing Considerations, page 593 for further information. Snap-In Hangers Recommended Maximum Hanger Spacing
Cable Size Wind Speed: Radial Ice: 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 7/8" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" Wind Speed: Radial Ice: 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 5/8" 7/8" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" LDF4-50A LDF4-75 FSJ4-50B FSJ4-75A HL4RP-50 HLT4-50 HS4RP-50 HST4-50 HT4-50 HJ4-50 LDF4.5-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 FT5-50T LDF6-50 LDF7-50A HJ7-50A LDF12-50 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-6 206706A-2 206706A-2 206706A-2 206706A-2 206706A-2 206706A-3 206706A-4 206706A-4 206706A-5 LDF4-50A LDF4-75 FSJ4-50B FSJ4-75A HL4RP-50 HLT4-50 HS4RP-50 HST4-50 HT4-50 HJ4-50 LDF4.5-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 FT5-50T LDF6-50 LDF7-50A HJ7-50A LDF12-50 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-1 206706A-6 206706A-2 206706A-2 206706A-2 206706A-2 206706A-2 206706A-3 206706A-4 206706A-4 206706A-5 Cable Type Number Hanger Type Number No Ice 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) No Ice 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) Recommended Maximum Hanger Spacing, feet (meters) 85 mph (137 km/h) 1/2" (13 mm) 1" (25 mm) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) No Ice 100 mph (160 km/h) 1/2" (13 mm) 1" (25 mm) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) No Ice
125 mph (200 km/h) 1/2" (13 mm) 1" (25 mm) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 1 (0.30)
150 mph (240 km/h) 1/2" (13 mm) 1" (25 mm) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30) 1 (0.30)
3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simutaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
595
The maximum spacing recommendations assume that all hangers are properly installed and tightened. Recommendations for a 150 ft (46 m) tower with 125 mph (200 km/h) wind speed and 1/2" radial ice (typical conditions) are highlighted in red. See Hanger Spacing Considerations, page 593 for further information. Insulated Hangers Recommended Maximum Hanger Spacing
Cable Size Wind Speed: Radial Ice: 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" 2-1/4" 3" 4" 5" 5" FSJ1-75A HST1-50 LDF1-50 EFX2-50 ETS2-50 FSJ2-50 HS2RP-50 HST2-50 LDF2-50 FSJ4-50B FSJ4-75A LDF4-50A LDF4-75A HL4RP-50 HLT4-50 HS4RP-50 HST4-50 HT4-50 HJ4-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 LDF6-50 HJ7-50A LDF7-50A HJ12-50 LDF12-50 HJ8-50B HJ11-50 HJ9-50 HJ9HP-50 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-2 11662-2 11662-2 11662-2 33948-5 33948-3 33948-3 33948-6 33948-6 33948-2 33948-4 33948-1 33948-1 Cable Type Number Hanger Type Number No Ice 3.5 (1.07) 4.5 (1.37) 4.5 (1.37) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5.5 (1.68) 5 (1.52) 5.5 (1.68) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) Recommended Maximum Hanger Spacing, feet (meters) 85 mph (137 km/h) 1/2" (13 mm) 1" (25 mm) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3 (0.91) 3.5 (1.07) 3.5 (1.07) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3.5 (1.07) 3.5 (1.07) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 1.5 (0.46) 2 (0.61) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 3 (0.91) 3 (0.91) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3 (0.91) 3 (0.91) 5.5 (1.68) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) No Ice 100 mph (160 km/h) 1/2" (13 mm) 1" (25 mm) 1.5 (0.46) 2 (0.61) 2.5 (0.76) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2.5 (0.76) 3 (0.91) 3 (0.91) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 3 (0.91) 3 (0.91) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 1 (0.30) 1.5 (0.46) 1.5 (0.46) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 4.5 (1.37) 5 (1.52) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
3 (0.91) 4 (1.22) 4 (1.22) 4.5 (1.37) 5 (1.52) 5 (1.52) 5 (1.52) 5 (1.52) 4 (1.22) 4.5 (1.37) 4.5 (1.37) 5 (1.52) 5 (1.52) 5 (1.52) 5 (1.52) 4.5 (1.37) 4.5 (1.37) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simutaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
596
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
The maximum spacing recommendations assume that all hangers are properly installed and tightened. Recommendations for a 150 ft (46 m) tower with 125 mph (200 km/h) wind speed and 1/2" radial ice (typical conditions) are highlighted in red. See Hanger Spacing Considerations, page 593 for further information. Insulated Hangers Recommended Maximum Hanger Spacing
Cable Size Wind Speed: Radial Ice: 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 7/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 1-5/8" 2-1/4" 2-1/4" 3" 4" 5" 5" FSJ1-75A HST1-50 LDF1-50 EFX2-50 ETS2-50 FSJ2-50 HS2RP-50 HST2-50 LDF2-50 FSJ4-50B FSJ4-75A LDF4-50A LDF4-75A HL4RP-50 HLT4-50 HS4RP-50 HST4-50 HT4-50 HJ4-50 LDF5-50A HJ5-50 HJ5-75 HT5-50 LDF6-50 HJ7-50A LDF7-50A HJ12-50 LDF12-50 HJ8-50B HJ11-50 HJ9-50 HJ9HP-50 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-3 11662-2 11662-2 11662-2 11662-2 33948-5 33948-3 33948-3 33948-6 33948-6 33948-2 33948-4 33948-1 33948-1 Cable Type Number Hanger Type Number Recommended Maximum Hanger Spacing, feet (meters) 125 mph (200 km/h) No Ice 1/2" (13 mm) 1" (25 mm) 2.5 (0.76) 3 (0.91) 3 (0.91) 3.5 (1.07) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3.5 (1.07) 3.5 (1.07) 3.5 (1.07) 4 (1.22) 4 (1.22) 4 (1.22) 4 (1.22) 3.5 (1.07) 3.5 (1.07) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 4.5 (1.37) 4.5 (1.37) 1 (0.30) 1.5 (0.46) 2.5 (0.76) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 2 (0.61) 2 (0.61) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2.5 (0.76) 2.5 (0.76) 5 (1.52) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 4.5 (1.37) 4.5 (1.37) 1 (0.30) 1 (0.30) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 3.5 (1.07) 4 (1.22) 4.5 (1.37) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5.5 (1.68) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 4.5 (1.37) 4.5 (1.37) No Ice 150 mph (240 km/h) 1/2" (13 mm) 1" (25 mm) 1 (0.30) 1.5 (0.46) 1.5 (0.46) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 1.5 (0.46) 2 (0.61) 2 (0.61) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2.5 (0.76) 2 (0.61) 2 (0.61) 4 (1.22) 6 (1.83) 4.5 (1.37) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5 (1.52) 3.(0.91) 3.(0.91) 0.5 (0.15) 1 (0.30) 1 (0.30) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1 (0.30) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 1.5 (0.46) 3 (0.91) 3 (0.91) 3.5 (1.07) 5 (1.52) 5 (1.52) 5.5 (1.68) 6 (1.83) 4.5 (1.37) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 4.5 (1.52) 3 (0.91) 3 (0.91)
2 (0.61) 2.5 (0.76) 2.5 (0.76) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2.5 (0.76) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 6 (1.83) 6 (1.83) 5 (1.52) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 6 (1.83) 5 (1.52) 3 (0.91) 3 (0.91)
Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simutaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
597
The maximum spacing recommendations assume that all hangers are properly installed and tightened. Recommendations for a 150 ft (46 m) tower with 125 mph (200 km/h) wind speed and 1/2" radial ice (typical conditions) are highlighted in red. See Hanger Spacing Considerations, page 593 for further information.
Note: These same hanger spacing recommendations apply for the other following 1/2" cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
Note: These same hanger spacing recommendations apply for the other following 5/8" cable types: HJ4.5-50
Note: These same hanger spacing recommendations apply for the other following 7/8" cable types: VXL5-50, HJ5-50, HJ5-75, HT5-5.
Note: These same hanger spacing recommendations apply for the other following 1 5/8" cable types: HJ7-50A
No Ice 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 2 (0.61)
125 mph (200 km/h) 1/2" (13 mm) 1" (25 mm) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 2 (0.61) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 3 (0.91) 2 (0.61) 3 (0.91) 2 (0.61) 2 (0.61)
No Ice 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
150 mph (240 km/h) 1/2" (13 mm) 1" (25 mm) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61) 2 (0.61)
Note: These same hanger spacing recommendations apply for the other following 1/2" cable types: LDF4-75A, HL4RP-50, HLT4-50, HS4RP-50, HST4-50, HT4-50, HJ4-50
Note: These same hanger spacing recommendations apply for the other following 5/8" cable types: HJ4.5-50
Note: These same hanger spacing recommendations apply for the other following 7/8" cable types: VXL5-50, HJ5-50, HJ5-75, HT5-50
Note: These same hanger spacing recommendations apply for the other following 1 5/8" cable types: HJ7-50A. * These hanger spacings have been specified based on using the Click-On hangers with Andrew specified hardware kits. Definitions and Assumptions 1. Per EIA-222 Standard: Coefficient of drag for coaxial cable is 1.2 (cylindrical members). Ice forms completely around member (360 degrees). Combined wind and ice loading is reduced by 25% to reflect lower probability of wind and ice occuring simutaneously. 2. Wind speeds are maximum, which includes gust factors and exposure factors.
598
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Andrew offers a wide variety of hangers and cable ties for reliable and convenient support of HELIAX coaxial cables. Standard Hangers feature great strength and long term reliability. They are ideal for general purpose use. Insulated Hangers are for use on insulated towers. Snap-In Hangers offer quickest and easiest installation for cable sizes 1/2" to 2-1/4". Click-On Hangers support two cables and are stackable up to three high (six cables). They are easy to install and are ideal for towers with limited space. KwikClamp Hangers attach one, two or three cable runs to a tower without the need for adapters or drilling holes. Nylon Cable Ties are lowest cost for cables 1/2" and smaller. They are ideal for 1/4" and 3/8" cable and for temporary installations. Velcro* Cable Ties are the easiest way to organize jumpers within and between radio cabinets.
* Velcro is a registered trademark of Velcro Industries.
Standard Hanger
Insulated Hanger
Snap-In Hanger
Click-On Hangers
KwikClamp Hangers
Cable Ties
599
F Angle Adapter, Stainless Steel, kit of 10 pieces. For mounting cable 1/2" to 4" cable hangers to angle tower members up to 7/8" (22mm) thick. Includes hanger attachment hardware. See page 570 for bulk packs 3/8" Hardware ..........................................Type 31768A Metric Hardware .................................Type 31768A-M G Angle Adapter, Galvanized, kit of 10 pieces. For mounting cable 1/2" to 2-1/4" cable hangers to angle tower members up to 3/4" (19 mm) thick. Includes hanger attachment hardware. 3/8" Hardware, kit of 10 ...........................Type 242774 Metric Hardware, kit of 10 ...................Type 242774-M H 45 Adapter Kit of 10. Use with angle adapter and threaded rod support kit to place a hanger at a waveguide bend. Galvanized steel .............Type 42334 I Round Member Adapter Kit of 10 pieces. Stainless steel clamps to mount 1/2" to 4" cable hangers to round support members. Two each are needed for 3" and 4" cable hangers.
Member Diameter, in (mm) 1 - 2 (25 - 50) 2 - 3 (50 - 75) 3 - 4 (75 - 100) 4 - 5 (100 - 125) 5 - 6 (125 - 150) 6 - 8 (150 - 200) Type Number 31670-1 31670-2 31670-3 31670-4 31670-5 31670-6
D Hardware Kit of 10 sets. 3/8" fillister-head bolts, lock washers and nuts for attachment of hangers to drilled tower members. 3/4" (19 mm) long .................................Type 31769-5 1" (25 mm) long .....................................Type 31769-1 E Compact Angle Adapters, Stainless Steel. The adapters are suitable for use with single runs of HELIAX cable up to 2-1/4" diameter. When used with our stackable, Click-On hangers, they can accommodate up to six runs of LDF6 (1-1/4") or smaller and up to four runs of LDF7 (1-5/8") HELIAX cables. 3/8" Hardware ..........................................Type 243684 Metric Hardware ..................................Type 243684-M
600
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
J Tower Standoff Kit of 10 pieces. Adapters with round member clamps and hardware for 1/2" to 4" hangers. All parts are stainless steel or galvanized.
Member Diameter in (mm) 0.75 - 1.5 (20 - 40) 1.5 - 3.0 (40 - 75) 3 - 4 (75 - 100) 4 - 5 (100 - 125) 5 - 6 (125 - 150) 1 in (25 mm) Standoff 30848-5 30848-4 30848-1 30848-2 30848-3 2.5 in (60 mm) Standoff 41108A-1 41108A-2 41108A-3
M Support/Hoisting Grip. Use at 200 ft (60 m) intervals to raise cable and provide permanent cable support. Basic kit includes one grip and one support clamp. Support clamps are also available in kits of 10. Installation tool is required .......................Type SG-IT
For Cable Type 1/4" FSJ1 1/4" LDF1 3/8" EFX2 3/8" LDF2 3/8" FSJ2 1/2" FSJ4 1/2" LDF4 5/8" LDF4.5 7/8" LDF5/VXL5 1-1/4" LDF6/VXL6 1-5/8" LDF7/VXL7 2-1/4" LDF12 Grip with One Clamp F1SGRIP L1SGRIP E2SGRIP L2SGRIP F2SGRIP F4SGRIP L4SGRIP L45SGRIP L5SGRIP L6SGRIP L7SGRIP L12SGRIP Support Clamp Kit of 10 F1SGRIP-1IK L1SGRIP-1IK E2SGRIP-2IK L2SGRIP-2IK F2SGRIP-2IK F4SGRIP-4IK L4SGRIP-4IK L45SGRIP-45IK L5SGRIP-5IK L6SGRIP-6IK L7SGRIP-7IK L12SGRIP-12IK
K Threaded Rod Support Kit. Use to mount hangers away from supporting structure, under cable bridge and inside equipment room. Includes 3/8" diameter threaded rod, galvanized ceiling mounting plate, nuts and washers. Attach to angle tower members with 31768A angle adapters. Attach to round tower members with 30848 series tower standoffs. All components are stainless steel, except ceiling mounting plate.
Rod Length in (mm) 12 (305) 24 (610) 36 (915) Kit of 1 31771 31771-9 Kit of 5 31771-4 31771-6 31771-10
L Hoisting Grip. Use at 200 ft (60 m) intervals to raise cable on tower. Use with optional support clamp to achieve optimum cable grip.
Cable Size 1/2" 5/8" 7/8" 1-1/4" 1-5/8" 2-1/4" 3" 4" 5" Hoisting Grip Type Number 43094 29958 19256B 29961 24312A 31535 26985A 34759 31031-1 Optional Support Clamp Type Number F4SGRIP-4IK L45SGRIP-45IK L5SGRIP-5IK L6SGRIP-6IK L7SGRIP-7IK L12SGRIP-12IK
601
A Insulated Hanger for 1/4" to 7/8" Cables, Single. For use on insulated tower. Refer to tables on pages 596 and 597 for maximum spacing. For 1/4", 3/8" and 1/2" cables .................Type 11662-3 For 7/8" cable .........................................Type 11662-2 B Insulated Hanger for 1-1/4" - 5" Cables Single. For use on insulated tower.
Cable Size 1-1/4" 1-5/8" 2-1/4" 3" 4" 5" Max. Spacing Refer to tables on pages 596 and 597. Type Number 33948-5 33948-3 33948-6 33948-2 33948-4 33948-1
D Threaded Rod Support Kit of 5 pieces. 1/2" x 12" (305 mm) threaded rods, ceiling mounting plates, nuts and washers for suspending 5" cable hangers. All parts are stainless steel except galvanized ceiling mounting plate .......................................Type 31771-5 Angle Adapter Single. For insulated hangers. Maximum member thickness 7/8 in (22 mm). E For 1/2" and 7/8" cable ...........................Type 40430-1 F For 1-1/4" - 5" cable ................................Type 13555A G Round Member Adapter Single. For use with Type 33948 series (1-1/4"-5" cables) insulated hangers. Fits member diameters 1-3 in (25 - 75 mm). ...................................................................Type 13550 H Stainless Steel Wraplock 100 feet complete with fasteners. Use to attach 1/4" - 7/8" insulated hangers to round members. Not to be used to attach cable or waveguide directly to towers..............Type 12395-1
C Round Member Adapter/Tower Standoff Kit of 10 pieces. For mounting 5" cable hangers to round support members. HELIAX cable to clear tower leg flanges. Provides 2.5 in (60 mm) standoff. All parts are stainless steel or galvanized.
Member Diameter, in (mm) 3 - 4 (75 - 100) 4 - 5 (100 - 125) 5 - 6 (125 - 150) Type Number 43130-1 43130-2 43130-3
602
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Snap-In hangers can be used on any tower, by using the specially designed adapters described below. Guyed tower transmission support systems can also accommodate Snap-In hangers, when specified. Made of heavy gauge stainless steel. For hanger spacing recommendations, refer to page 595. Kit of 10 Hangers
Cable Size 1/2" 5/8" 7/8" 1-1/4" 1-5/8" 2-1/4" Type Number 206706-1 206706A-6 206706-2 206706-3 206706-4 206706-5
Snap-In Adapters
A Tower/Hanger Adapter cable support attaches to existing angle tower members. Includes angle support pre-punched with 3/4" and 7/16" holes to accommodate Snap-In hanger, and standard hanger.
Number of Cable Runs 1 4 8 J-Bolt or Angle Adapter Connections Required 1 2 3 Type No. 206929-1 206929-4 206929-8
B J-Bolt Hardware, Kit of 10 for attaching Tower/Hanger Adapter to 1-1/4" to 2-3/4" (32-70 mm) angle tower members. Includes J-bolt, flat washers, lock washers and nuts ..................................................Type 206930 C Angle Adapter, Kit of 10. For attaching Tower/Hanger Adapter to angle tower members. Stainless Steel, 3/8" hardware ................Type 31768A D Cluster Mount**. Octagonal cable support for one to seven cable runs attaches to 1-1/2" nominal steel pipe or 1.90" (48 mm) round tower members. Pre-punched with 3/4" and 7/16" holes to accommodate snap-in hangers and standard hangers. Supplied mounting hardware kit includes 3/8" plated bolts, flat washers, lock washers and nuts. Kit of 1 ....................................................Type 207030 Kit of 10 ..............................................Type 207030-2
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 B C
603
Snap-In Adapters
7/16" (11 mm) dia hole for attaching cover 1/4" (6 mm) dia hole for grounding wire
Snap-In Hanger
A B
4" (102 mm)
Length
Angle-leg or Pipe-leg
3/4" (19 mm) diameter holes Snap-in Hangers 7/16" (11 mm) diameter holes for Cushion Hangers 2-1/2" (64 mm) 2-1/2" (64 mm)
G E
A Snap-In Angle Adapter Kit of 10 pieces. Includes 3/4" pre-punched hole for mounting snap-in hangers to angle tower members. Stainless steel, 3/8" hardware ......................................................Type SAA B Snap-In Adapter Block Kit of 10 pieces. Mounts up to three snap-in hangers. Attach to tower using Type 31768A angle adapter or tower standoffs. Mechanically galvanized hardware .............Type SHA3 C Snap-In Tower Standoffs Kit of 10 pieces. Mounts snap-in hangers to round tower members and provides 2-1/2 in (64 mm) standoff. Includes 3/4" pre-punched hole. All parts stainless steel or galvanized.
Member Diameter, in (mm) 1-2 (25-50) 2-3 (50-75) 3-4 (75-100) 4-5 (100-125) Type STS-12 STS-23 STS-34 STS-45
E Universal Snap-In Brackets for both angle and round tower members. Pre-punched with 3/4" holes to mount up to twelve snap-in hangers. Galvanized steel.
Angle Member 2-1/2" to 4" 5" to 6" 8" Round Member Diameter 1-1/2" to 5-9/16" 6" to 8-5/8" 10-3/4" to 12-3/4" Type No. HAA-B2249 HAA-B2250 HAA-B2251
F Snap-In Adapter Brackets for large round members, water towers, or on the outside of a monopole. Mount up to three cable runs and are compatible with both snap-in and standard hangers. Use multiple brackets for additional runs. Use in conjunction with wraplock. The brackets slide on the wraplock. .........................................................Type HAA-B2391 G Stainless Steel Wraplock 100 feet complete with fasteners. Use to attach 1/4" - 7/8" insulated hangers to round members. Not to be used to attach cable or waveguide directly to towers..............Type 12395-1
D PVC Roof Sleeper, supports rooftop coax runs. Constructed of gray, UV resistant PVC. 4 in x 4 in (102 mm x 102 mm).
Number of Cable Runs 4 8 12 Dimensions, in (mm) 22 (559) 31.9 (810) 43.4 Type No. RTA-B1598 RTA-B1599 RTA-B1600
604
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Click-On Hangers
Install Cable with One Easy Click Click-on Hangers* are specifically designed to support HELIAX coaxial cable. They are stackable, install in just minutes, and provide a perfect fit that gives your PCS/PCN, cellular, microwave, rural telephony, GSM, or other telecommunications system a professional appearance, especially in confined spaces. The hangers are made of tough, UV-resistant material and set the standard for durability, simplicity of installation, and cost-effectiveness. Only two wrenches are required for installation. Refer to table on page 598 for maximum spacing.
*Patented United States No, 5794897
Click-On Hangers Ordering Information Kits of 10 Cable Size 1/2" 5/8" 7/8" 1-1/4" 1-5/8" Cable Type LDF4-50A LDF4.5-50A LDF5-50A LDF6-50 LDF7-50A Hanger Type Number L4CLICK L45CLICK L5CLICK L6CLICK L7CLICK
1/2", 5/8" or 7/8" Cable 1 2 3 1-1/4" or 1-5/8" Cable 1 2 3 243095-12 243095-8 243095-4 243095-10 243095-6 243095-2 243095-11 243095-7 243095-3 243095-9 243095-5 243095-1
Round Member Adapter, universal, kit of 10 Compact Angle Adapter, kit of 10 3/8" Hardware M10 Hardware Ceiling Adapter Stainless Steel Wraplock, 100 ft (305 m)
605
Click-On Hanger
Click-On Hanger
Nut Nut, Lock Washer and Flat Washer Nut, Lock Washer and Flat Washer
Hex Nut Ceiling Adaptor Lock Washer, Nut and Flat Washer
Threaded Rod
Click-On Hanger
Threaded Rod
Hex Nut
606
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
KwikClamp Hangers
Angle KwikClamp
Round/Flat KwikClamp
Channel KwikClamp
L5CLAMP-ANG40-1 L6CLAMP-ANG40-1 L5CLAMP-ANG40-2 L6CLAMP-ANG40-2 L5CLAMP-ANG40-3 L6CLAMP-ANG40-3 L5CLAMP-ANG50-1 L6CLAMP-ANG50-1 L5CLAMP-ANG50-2 L6CLAMP-ANG50-2 L5CLAMP-ANG50-3 L6CLAMP-ANG50-3 L5CLAMP-CNL-1 L5CLAMP-CNL-2 L5CLAMP-CNL-3 L6CLAMP-CNL-1 L6CLAMP-CNL-2 L6CLAMP-CNL-3
50 mm Angle
607
Cable Ties
Nylon Cable Tie Kit of 50 pieces. Weather-resistant straps for attaching 1/4" to 1/2" cables. Maximum spacing 3 ft (1 m) for HJ and LDF series and 18" (457 mm) for FSJ series cables. ..................................................Type 40417 Nylon Cable Tie Kit in Plastic Box. Black, weather-resistant cable ties. Kits are packaged in a reusable plastic box and organized for quick selection. Includes: Quantity 100, 4" (101 mm) cable ties, 18 lb (80 N) tensile strength Quantity 100, 5.5" (140 mm) cable ties, 40 lb (178 N) tensile strength Quantity 100, 7.5" (190 mm) cable ties, 50 lb (222 N) tensile strength 50 adhesive-backed black mounts ........Type CT-K350
Nylon Cable Tie Kit in Plastic Box
Nylon Cable Tie Installation Tool. For use with Type CT-K350, above. Tightens and trims cable tie in one process with one hand. Cuts ties flush with a simple 1/4 turn downward twist. Top loading for right or left hand users .......................................................Type CT-IT Jacketed Cable Tie Kit of 20 pieces. Weather-resistant ties for attaching FSJ Series cable directly to tower members. Maximum spacing 18" (457 mm) .................................................................Type 27290A Velcro* Cable Ties. The easiest way to organize inter-rack cabling. Secure in high-vibration areas. No special tying procedure required. Can be reused to accommodate future expansion. Black, 8" (203 mm) length. Maximum bundle diameter, 2" (51 mm). Minimum bundle diameter, 0.25" (6.4 mm). Tensile strength, 40 lb (178 N). For indoor use only. Kit of 10..................................................Type VCT8-10 Kit of 50 ................................................Type VCT8-50 Kit of 100 .............................................Type VCT8-100
* Velcro is a registered trademark of Velcro Industries.
608
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Grounding Kits
SureGround Kit
A well designed system uses grounding kits to provide a bond between the cable and the tower/earth ground system. One grounding kit is recommended at tower top, tower bottom, at 200 ft (60 m) intervals (where applicable), and at the entrance to the equipment shelter. SureGround and SureGround Plus Series and 204989 and 241088 Series Grounding Kits offer: Solid copper construction for high current handling capability, compatibility with copper cable outer conductors, and long life. Meet military standards at commercial prices. Provide certainty of continued operation. Tested at an independent laboratory to withstand 200,000 amps. Andrew 204989 and 241088 series solid copper grounding kits have passed United States Air Force lightning simulation tests and meet MIL-STD-188-124A. The non-braided solid copper construction of all Andrew grounding kits eliminates corrosion caused by moisture retention and wicking. A heat shrink tube protects the cable terminal connection.
Easy Installation Standard Grounding Kits (204989 and 241088 series) require few steps to install and include easy to follow instructions. Proper tensioning is ensured by an expansion section which provides visual indication that the strap is secured. SureGround Grounding Kits install in less than half the time required for standard grounding kits. Factory assembled into one component, they feature a pre-formed clip-on grounding strap for easy, snap-on installation. SureGround Plus Grounding Kits are even easier to install. Simply remove a short length of cable jacketing, snap the wraparound strap in place, slip the rubber boot into place and secure with clamps.
Kits Include
Standard Grounding Kits for 1/2" and Larger Cables. Series 204989 and 241088 kits include a solid copper strap riveted to the grounding wire, a coiling tool for proper tightening, tower attachment hardware, and a two-part tape weatherproofing system. Field-attachable, crimp-on grounding lugs require the use of a crimping tool (not included, described below). Standard Grounding Kit for 1/4" and 3/8" Cables. Includes a solid copper strap, connection hardware, tower atachment hardware, and a two-part tape weatherproofing system ...............................Type 223158 SureGround Grounding Kit is a one-piece factory assembled ground strap which includes a two-part tape weatherproofing system. SureGround Plus Grounding Kits include a factory assembled ground strap, a preformed rubber boot and two clamps.
609
Cable Size Grounding Wire Length: 1/4" and 3/8" 1/2" 5/8" and 7/8" 1-1/4" 1-5/8" 2-1/4" and 3" 4" 5"
610
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
600 mm (24 in) Grounding Wire LDF4 LDF45 LDF5 LDF6 LDF7 LDF12 SGL4-06B1 SGL45-06B1 SGL5-06B1 SGL6-06B1 SGL7-06B1 SGL12-06B1 SGL4-06B2 SGL45-06B2 SGL5-06B2 SGL6-06B2 SGL7-06B2 SGL12-06B2
1000 mm (39 in) Grounding Wire LDF4 LDF45 LDF5 LDF6 LDF7 LDF12 SGL4-10B1 SGL45-10B1 SGL5-10B1 SGL6-10B1 SGL7-10B1 SGL12-10B1 SGL4-10B2 SGL45-10B2 SGL5-10B2 SGL6-10B2 SGL7-10B2 SGL12-10B2
1500 mm (59 in) Grounding Wire LDF4 LDF4 LDF5 LDF6 LDF7 LDF12 SGL4-15B3 SGL45-15B3 SGL5-15B3 SGL6-15B3 SGL7-15B3 SGL12-15B3 SGL4-15B4 SGL45-15B4 SGL5-15B4 SGL6-15B4 SGL7-15B4 SGL12-15B4
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 2/01
611
600 mm (24 in) Grounding Wire LDF4 LDF4.5 LDF5 LDF6 LDF7 LDF12 SGPL4-06B1 SGPL45-06B1 SGPL5-06B1 SGPL6-06B1 SGPL7-06B1 SGPL12-06B1 SGPL4-06B2 SGPL45-06B2 SGPL5-06B2 SGPL6-06B2 SGPL7-06B2 SGPL12-06B2
1000 mm (39 in) Grounding Wire LDF4 LDF4.5 LDF5 LDF6 LDF7 LDF12 SGPL4-10B1 SGPL45-10B1 SGPL5-10B1 SGPL6-10B1 SGPL7-10B1 SGPL12-10B1 SGPL4-10B2 SGPL45-10B2 SGPL5-10B2 SGPL6-10B2 SGPL7-10B2 SGPL12-10B2
1500 mm (59 in) Grounding Wire LDF4 LDF4.5 LDF5 LDF6 LDF7 LDF12 SGPL4-15B3 SGPL45-15B3 SGPL5-15B3 SGPL6-15B3 SGPL7-15B3 SGPL12-15B3 SGPL4-15B4 SGPL45-15B4 SGPL5-15B4 SGPL6-15B4 SGPL7-15B4 SGPL12-15B4
612
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Punched for Arrestor Types All APTL Series, 7-16 DIN or Bolt Grounded APG and APM Series, 7-16 DIN or Bolt Grounded N Bulkhead or Bolt Grounded All APTL Series, 7-16 DIN or Bolt Grounded APG and APM Series, 7-16 DIN or Bolt Grounded N Bulkhead or Bolt Grounded
613
Ordering Information
Interface Type For LDF5-50A, 7/8" Foam-Dielectric Cable Bulkhead N Female Bulkhead 7-16 DIN Female For LDF6-50, 7/8" Foam-Dielectric Cable Bulkhead N Female Bulkhead 7-16 DIN Female For LDF7-50A, 7/8" Foam-Dielectric Cable Bulkhead N Female Bulkhead 7-16 DIN Female APTL7-BNF-(*) APTL7-BDF-(*) APTL6-BNF-(*) APTL6-BDF-(*) APTL5-BNF-(*) APTL5-BDF-(*) Type Number
Integrated Arrestor/Connector Design Insertion loss less than 0.1 dB Improved system performance Reduced component costs Easy installation
Completely weatherproof RingFlare connector design automatically flares the cable as the connector is tightened. Quarter-Wave Shorting Stub Technology Provides true multi-strike capability. Tests performed by independent laboratories verify that Arrestor Plus withstands in excess of 50 impulse current surges of 50 kA without product degradation. Reliable equipment protection Maintenance free
614
Revised 12/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Operating Frequencies
Frequency Band, MHz** 824-960 824-900 870-960 800-870 1700-1900 1850-1990 Insertion Loss, dB < 0.1 < 0.1 < 0.1 < 0.1 < 0.1 < 0.1 VSWR Max. 1.10 1.07 1.07 1.07 1.07 1.07 Detail Number -1 -2 -3 -6 -11 -9
615
616
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Weatherproofing
Cable Size For Connector Interface 1-5/8" to 1/2" For Splices 3", 4" and 5" 1-5/8" and 2-1/4" 1-1/4" 7/8" 1/2"
1 2 6 8 12
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 9/00 &12/00
617
Weatherproofing
1.20-0.84 (30-12) 0.48 (12) 0.84 (21) 1.20 (30) 1.20 (30)
Kits for Type N and 7-16 DIN Connectors 5/8"-3/8" 5/8"-1/2" 5/8"-5/8" 7/8"-1/4" 7/8"-3/8" 7/8"-1/2" 1-1/4"-1/4" 1-1/4"-3/8" 1-1/4"-1/2" 1-5/8"-1/4" 1-5/8"-3/8" 1-5/8"-1/2" 2-1/4"-3/8" 2-1/4"-1/2" Kits for Antenna Interfaces** 1/4"-1-1/2" Omni/Panel base or Type N or DIN 3/8"-1-1/2" Omni/Panel base or Type N or DIN 1/2"-1-1/2" Omni/Panel base or Type N or DIN 1/4"-2" Omni/Panel base or Type N or DIN 3/8"-2" Omni/Panel base or Type N or DIN 1/2"-2" Omni/Panel base or Type N or DIN 1/2" LDF4 - Type N interface 5/8"-Type N or DIN interface 7/8"-Type N or DIN interface 0.29 (7.4) - *** 0.41 (10) - *** 0.41 (10) - *** 0.29 (7.4) - *** 0.41 (10) - *** 0.41 (10) - *** 0.49 (12) - *** 0.80 (20) - *** 0.49 (12) - *** 241548-10 241548-8 241548-8 241548-11 241548-9 241548-9 241548-4 241474-7 241548-5 0.80-0.41 (20-10) 0.80-0.63 (20-16) 0.80-0.80 (20-20) 0.84-0.29 (21-7.4) 0.84-0.41 (21-10) 0.84 0.63 (21-16) 1.20-0.29 (30-7.4) 1.20-0.41 (30-10) 1.20-0.63 (30-16) 1.20-0.29 (30-7.4) 1.20-0.41 (30-10) 1.20-0.63 (30-16) 1.40-0.41 (36-10) 1.40-0.63 (36-16) 241475-13 241475-13 241474-7 241475-12 241475-9 241475-9 241475-11 241475-5A 241475-5A 241475-11 241475-5A 241475-5A 241475-8 241475-8
Kits for Arrestor Plus Surge Protectors 7/8" LDF5 APTL5 1-1/4" LDF6 APTL6 1-5/8" LDF7 APTL7 0.84 1.20 1.20 241474-5 241474-6 241474-6
* Minimum application diameter is the fully compressed diameter of each tube in the kit. ** Andrew Cold Shrink weatherproofing is completely compatible with Andrew base station antennas. Request bulletin 10138 for complete details.
618
Revised 9/00
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
4" (102 mm) Entry Opening, Multiple Entrance Plate D E 1 1 4 8 12 16 7 (178) 5 (127) 9.5 (241) 17.5 (444) 25.5 (648) 25.5 (648) 7 (178) 5 (127) 25.5 (648) 25.5 (648) 25.5 (648) 25.5 (648) 5.5 (139) 5.5 (139) 5.5 (139) 5.5 (139) 204673-1 204673-2 204673-4 204673-8 204673-12 204673-16
A Single Entrance Wall/Roof Feed Thru Assembly. Includes rubber boot, clamp and galvanized steel plate. Order from table. B Multiple Entrance Wall/Roof Feed Thru Plate.Plate with one or more 4 or 5-inch entry holes. Use with the corresponding size rubber cable boots (sold separately). C Cable Entry Boot. Use with above feed thru plate, with the corresponding size entry hole.
5" (127 mm) Entry Opening, Multiple Entrance Plate 1 2 3 4 6 9.5 (241) 9.5 (241) 9.5 (241) 17.5 (444) 17.5 (444) 9.5 (241) 17.5 (444) 25.5 (648) 17.5 (444) 25.5 (648) 7 (178) 7 (178) 7 (178) 7 (178) 48940-1 48940-2 48940-3 48940-4 48940-6
NEW!
D SNAP-IN Entry Port. Patent Pending. Snaps into a cabinet or metal plate, 0.06 to 0.14 in (1.5 to 3.5 mm) thick, with a 3.5 in (89 mm) diameter hole. If your cabinet or metal plate has a 4 in (100 mm) hole, use adapter plate below. Constructed from a weather-resistant engineering plastic. Use with One-Piece cable entry boot (Item C) for a durable, low cost alternative to fabricated metal entry ports. SNAP-IN Entry Port ............................ Type SEP-4 SNAP-IN Entry Port, kit of 10 .............Type SEP-4-10 Blank Cap, 4 in (100 mm)................... Type CAP-4 Blank Cap, 4 in (100 mm), kit of 10.... Type CAP-4-10 E Adapter Plate. Mounts SNAP-IN entry port (Item D) to an existing 4 in (100 mm) opening in a cabinet or metal plate, 0.06 to 0.14 in (1.5 to 3.5 mm) thick. ..............................................................Type SEPA-4 Wall/Roof Feed Thru Assembies, Single Entrance
Cable Size 1/2" 5/8" 7/8" 1-1/4" 1-5/8" 2-1/4" 3" 4" 5" Type Number 40656A-3 40656A-7 40656A-1 40656A-5 40656A-2 40656A-6 40394-2 40394-1 33938-5
4" (102 mm) Cable Boots 1/4" Foam 3/8" Foam 1/2" Foam 1/2" Foam 1/2" Foam 1/2" Air 1/2" Air 5/8" 5/8" 7/8" 7/8" 7/8" 1-1/4" 1-5/8" 2-1/4" 3" 5" (127 mm) Cable Boots 3/8" Foam 1/2" Foam 1/2" Foam 1/2" Foam 1/2" Air 1/2" Air 5/8" 5/8" 7/8" 7/8" 1-1/4" 1-5/8" 2-1/4" 3" 3 1 3 4 1 3 1 3 1 3 1 1 1 1 48939A-16 48939A-6 48939A-8 48939A-17 48939A-7 48939A-5 48939A-14 48939A-15 48939A-1 48939A-2 48939A-3 48939A-4 48939A-9 48939A-10 3 1 1 3 4 1 3 1 3 1 2 3 1 1 1 1 204679A-17 204679A-19 204679A-5 204679A-7 204679A-16 204679A-6 204679A-1 204679A-13 204679A-14 204679A-2 204679A-18 204679A-15 204679A-3 204679A-4 204679A-8 204679A-9
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00
619
ArrestorPort II
The ArrestorPort II is the latest design offering the greatest cost savings and installation ease for wireless systems using surge arrestors.
620
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
* For discontinued tool CPT-F4A use CPT-BKS1 blade kit For discontinued tool CPT-F4B use CPT-BKSF4 blade kit
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 12/00 & 5/01
621
DIN
LDF5 Kit
x x x x x x x x x x
x x x x x x x x x
622
Revised 5/01
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Attachment Tools
Wrenches
Crimping Tool
Description 2-5/8" torque wrench 2-1/4" torque wrench 1-7/8" torque wrench 21mm torque wrench 1-1/4" torque wrench 1-1/4" torque wrench 13/16" torque wrench
Application LDF12 connectors LDF7 connectors LDF6 connectors LDF4.5 connectors Coupling torque DIN connectors LDF5 connectors Coupling torque N connectors
Wrench Kit
Kit includes the three wrenches listed below. ..................................................................Type 244372 Type 244459-7, wrench for LDF7 (1-5/8") connectors Type 244459-6, wrench for LDF6 (1-1/4") connectors Type 244459-5, wrench for LDF5 (7/8") connectors
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 7/00 & 5/01
623
Connector Accessories
A Connector PIN-PAKS. Replacement connector center pins individually packaged in sets (quantities shown below). Each pin can be easily separated from the set. PIN-PAKS for 7/8" cable and smaller include five replacement pins: PIN-PAKS for 1-1/4" and 1-5/8" cable include two replacement pins.
For Connector Type F1PNM-H C41SW F2NM, F2NM-H F2PNM, F2PNM-H F2PDM F4NM, F4NM-H F4NMV2 F4PNM, F4PNM-H F4PNMV2 F4NF F4PNF F4PDM F4PDMV2 L2NM, L2NM-H L2PNM, L2PNM-H L4NM, L4NM-H L4PNM, L4PNM-H L4PDM L4NF L4PNF L5NM L5PNM, L5PNM-H L5NF L5PNF L5PDM L5PDF, L5PDF-BH L6PNM, L6PNM-H L6PNF L6PDF, L6PDF-BH L6PDM L7PNF L7PNM L7PDM V5PNF V5PNM V5PDF V5PDM PIN-PAK Type No. 242881 241051-3 242075-3 242075-4 114402-2 241455-3 243640-2 241455-4 243472-2 241496-3 241496-4 114417-2 243465-2 48335-3 48335-4 241730-3 241730-4 222483-2 242855 242855-2 43158-5 241495 43157-2 241092 114105 114105-2 243370 241057 114105-4 114105-3 241056 243371 242960 244985-2 244983-2 244989-2 244987-3 Quantity Per Kit 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 1 5 5 5 5
B Bulkhead Adapter. For use with type N or UHF jacks for 1/4", 3/8", 1/2" or 7/8" HELIAX cable. Includes faceplate and mounting hardware .........Type 26016-2 Connector Reattachment Kit includes rubber O-ring and gasket parts to replace those which may be damaged during disassembly and subsequent reattachment of connectors. Does not include interface O-rings or gaskets.
Cable Types LDF2-50 LDF4-50A FSJ4-50B LDF5-50A LDF6-50 LDF7-50A HJ4-50,HT4-50 HJ5-50 For Connector Types Reattachment Kit Type No. 34767A-38 34767A-27 34767A-51 34767A-39 34767A-66 34767A-28 34767A-43 34767A-35 34767A-22 34767A-3 34767A-5 34767A-44 34767A-18 34767A-6 34767A-7 34767A-20 34767A-19 34767A-13 34767A-46 34767A-50 34767A-49 34767A-47 34767A-60 34767A-10 34767A-30 34767A-57 34767A-58 34767A-59 34767A-15 34767A-16 34767A-40 34767A-41 34767A-17 34767A-55 34767A-56 34767A-45 34767A-31
Foam-Dielectric Cables L2 and L42 Series L44 Series, except L4NM, L44PCW, L44PCN, L4NM, L44PCW, L44PCN F4 and 44AS Series F4V2 Series L5 and L45 Series L6 and L46 Series L7 and L47 Series H4PNM, H4PNF, 74PN, 74PW H5PNF, H5PNM, 75PN, 75AR, 75PW 75AG, 75AU 75ART, 75AGT H5NF-T, 75NT 87G, 87R H7PNF, 87PN, 87S, 87SG 87SGT, 87ST H7NF-T, H7NM-T, 87NT, 87WT 87Z H12PNF, 82PN 82GF 82RF 82R H8( )-302 78AGF, 78ARM, 78ARF, 78AGM, 78AS 78BZ H11( )-602 H11( )-M408 H11( )-302 81RF 81GF 42826 42896 81Z H9( )-602, H9HP( )-602 H9( )-M408, H9HP( )-M408 79AG, 79AR 79AZ, H9HPZ
Air-Dielectric Cables
HJ7-50A
HJ12-50
HJ8-50B
HJ11-50
HJ9-50, HJ9HP-50
624
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Connector Adapters
Ordering Information
Description A L M B C D E F G N O H I J K L P M Q N O P Q N Junction, female-female, UG-29B/U N Junction, male-male, UG-57B N Right Angle, male-female, UG-27D/U N Tee, female-female-female, UG-28A/U UHF Junction, female-female, PL-258 UHF Right Angle, male-female, M-359A UHF Tee, female-male-female, M-358 N female-UHF male N male-UHF female Flange Adapter, F flange, male-7/8" EIA, 50 ohm F Flange, female-N female F Flange Elbow, F Flange, male-F Flange, female 7-16 DIN male-N female 7-16 DIN male-N male 7-16 DIN female-N female 7-16 DIN female-N male 90 Miter Elbow, 7/8" EIA, 50 ohm 90 Miter Elbow, 1-5/8" EIA, 50 ohm 90 Miter Elbow, 3-1/8" EIA, 50 ohm N female-7/8" EIA, 50 ohm N female-1-5/8" EIA, 50 ohm N female-3-1/8" EIA, 50 ohm LC female-7/8" EIA, 50 ohm LC female-1-5/8" EIA, 50 ohm N Male-TNC Male N Female-TNC Male N Male-N Male, hex head Type No. 10804-11 10804-9 10804-66 10804-17 10805-6 10805-5 10804-4 10805-12 10805-11 33682 104300-2 203361 CA-PNFDM CA-PNMDM CA-PNFDF CA-PNMDF 1060A ACX150-10SE ACX350-10SE 2260B 2261A 2262 2360A 2361A CA-NMTM CA-NFTM CA-NMNM-H
R R S S T U T U V V
U.K. 0800-250055 Australia 1800-803 219 New Zealand 0800-441-747 Revised 12/00
625
Elevator Shaft
Floor penetration
False Ceiling
626
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
Fire Gas Toxicity Fire Retardant Jacketing Characteristics. Some coaxial cables use halogenated polymeric jacketing to provide fire retardance. (Halogens are chemically related elements such as fluorine, chlorine, and bromine.) The drawback to such materials is increased levels of smoke and toxic gases under fire. All HELIAX Coaxial Cables rated Type CATVR achieve fire retardance by using non-halogenated jacketing. While such a jacketing has low toxicity characteristics when burned, it is somewhat less effective at high temperatures than halogenated jacketing. Presently, it is not possible to achieve the highest fire retardance rating, CATVP, without either employing halogenated jacketing or omitting the jacket entirely; consequently, Type CATVP listed HELIAX cables presently use halogenated fire retardant jacketing. New York State Requirements. The New York State Department of State (DOS) Office of Fire Prevention and Control publishes a Fire Gas Toxicity Data File for products covered by Article 15, Part 1120 of the New York State Uniform Fire Prevention and Building Code. Only products listed in this directory are permitted to be used in the construction of some buildings in New York State. All of Andrew Corporations cable and waveguide products are listed in the Fire Gas Toxicity Data File, as follows:
New York State DOS File Number 16120-880602-2007 Listed Manufacturer Andrew Listed Cables All Codes All Codes All Codes All Codes
Market Name RADIAX Slotted Coaxial Cable Foam Dielectric HELIAX Coaxial Cable Foam Dielectric HELIAX Coaxial Cable Air Dielectric HELIAX Elliptical Waveguides
16120-880602-2008
Andrew
16120-871217-1058
Andrew
16120-880602-2006
Andrew
627
628
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
** High temperature foam dielectric. *** Type CATVP elliptical waveguides are available on request. All cables meet standards BS4066 Part 1 and IEC332 Part 1. Type CATVP, CATVR and CATV cables meet BS4066 Part 3 and IEC332 Part 3, Catagory C. All type CATVP air-dielectric cables are also listed by the Canadian Standards Association (CSA) as Communications Cable, Type CXC-FT4, FT6. They carry dual UL/CSA markings. All type CATVR, CATV, and CATVX RADIAX, superflexible, and foam-dielectric cables listed comply with equivalent Canadian Standards Association (CSA) requirements and are CSA marked.
629
Intermodulation Generation
Figure 1 Bulk Length of LDF4-50A
-60 -70 -60 -70
1875
1880
1885
1890
1895
1900
1905
1910
3rd Order IM Frequency, MHz Test Power +43 dBm for Each Tone
3rd Order IM Frequency, MHz Test Power +43 dBm for Each Tone
Intermodulation (IM), the intermixing of fundamental signal frequencies in a nonlinear circuit, has been a problem in multichannel communication systems for years. IM produces additional spurious signals at frequencies close to the operating frequencies, which can create additional noise in the system or even swamp the channel and make it unavailable for traffic. The many channels in modern wireless communications systems are typically arranged into base station transmit and receive frequency bands. Depending on the particular generating signal frequencies, IM products can fall into these receive frequencies. It therefore becomes desirable to keep the IM level low enough to prevent additional noise at the receivers. Any deviation from linearity in a circuit will cause some IM. Nonlinearity is present when the voltage is not exactly proportional to the current or if output power is not exactly proportional to input power. Imperfect contacts at conductor junctions and the presence of ferromagnetic materials in or near the current path are the two main causes of nonlinearity in passive circuits. Measured passive IM levels are not very dependent on frequency, but do depend on the signal amplitude. Thus, when measuring or specifying IM performance of a component, the power levels of the carriers must be specified. Typically, testing is performed using two tones fairly closely spaced in frequency, the power level of each being 20 W (+43 dBm).
Low IM vs. Inferior Designs dBm Large number of components Low pressure contact, outer Low pressure contact, inner Nickel plating Low IM design -95 -96 -85 -83 -120 to -130
HELIAX cables, constructed from a single inner and single outer conductor deliver the best IM performance. Because current flow in coaxial cables is longitudinal, designs with many individual conductors require the current to cross numerous boundaries, each boundary being capable of producing IM products. It is not possible to apply high pressure between the individual conductors of a braided or foil-braid cable, for example, to improve IM performance. IM levels for braided cables are typically -80dBm or worse at a test power level of +43 dBm. By contrast, Figure 1 and Figure 2 show the excellent IM performance of HELIAX cables. Figure 1 is the IM characteristic for a bulk length (approximately 5,000 feet) of LDF4-50A, swept in frequency through the PCS band, and Figure 2 is a similar plot for an assembly length (15 feet) of FSJ4-50B. Levels for both are -120 dBm or better at the test power level of +43 dBm for each tone. HELIAX connectors are also designed and manufactured for the lowest IM. Three factors are important in connector design to minimize IM generation. First, the number of individual contact surfaces must be a few as possible. Second, where contact surfaces are necessary, they must be designed for excellent contact by using means to generate high pressure or by using soldering. Third, base materials, platings, and underplatings at RF current-carrying surfaces must not be made of ferromagnetic materials. The table shows measured IM levels for various RF connectors fitted to short lengths of cable. Andrew connectors, designed and constructed using these principles for low IM generation outperform other manufacturers designs that deviate from these principles in one way or another.
630
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
-40
-20
20
40
60
80
100
1.25
1.5
1.75
2.0
2.25
2.5
2.75
3.0
Ambient Temperature, C
VSWR at Termination
Attenuation The attenuation versus frequency characteristics of HELIAX coaxial cables are provided as part of the data for each cable in this catalog. The figures are guaranteed to within 5%. The values provided are for 20C (68F) ambient and increase slightly with higher temperature or applied power, up to approximately 15% above the curves at 100C (212F) ambient temperature. Figure 1 shows this relationship. Temperature Ratings for HELIAX Coaxial Cables
Effect of Connector on Transmission Line Loss Usually, connector insertion loss is negligible compared with the attenuation of the cable. Connector insertion loss depends on the frequency of operation. You can easily calculate the total transmission line insertion loss (the sum of cable attenuation and insertion loss of the connectors) using our AASP software available on our web site at www. andrew.com. To approximate insertion loss for two connectors, add 0.1 dB to the transmission line loss.
Storage
Installation
Operation
Standard Black Polyethylene Jacketed Cables Up to 2-1/4" Cables 3" and Larger Cables Connectors C F CATVX Rated Cables C F CATVR Rated Cables C F CATVP Rated Cables Polyethylene Dielectric High Temperature Dielectric C F C F -40 to 85 -40 to 185 -40 to 100 -40 to212 -40 to 60 -40 to 140 -40 to 60 -40 to 140 -40 to 85 -40 to 185 -40 to 150 -40 to 302 -30 to 80 -22 to 176 -25 to 60 -13 to 140 -30 to 80 -22 to 176 -30 to 80 -22 to 176 -25 to 60 -13 to 140 -30 to 80 -22 to 176 -70 to 100** -94 to 212** -40 to 60 -40 to 140 -55 to 150*** -67 to 302*** C F C F -70 to 85* -94 to 185* -70 to 85* -94 to 185* -40 to 60 -40 to 140 -40 to 60 -40 to 140 -55 to 85 -67 to 185 -40 to 85 -40 to 185
* Cable with connectors attached rated to -40C (-40F). ** Upper temperature limited by connector package material. Storage defined as packaged connectors, not connectors installed on cable. *** If connectors are operated above 100C (212F) and then separated, interface seals (gaskets or O-rings) should be replaced before remating. Air cable and connectors will operate below -40C (-40F), but may experience air pressure loss exceeding 1lb/in2 (7kPa) in 24 hours. For CATVP air cables, 7/8" and larger, the installation temperature is -20 to 60C (-4 to 140F)
631
Load VSWR Effect on Total Transmission Loss When the transmission line is attached to a load, such as an antenna, the VSWR of the load increases the total transmission loss of the system. This effect is quite small for normal conditions. Figure 2 on page 631, shows the minimum increase in loss with load VSWR, assuming a VSWR of 1.0 at the input of the transmission line. This requires use of an input matching device. Power Rating Considerations Both peak- and average-power ratings are required to fully describe the capabilities of a given transmission line. Typically, peak-power ratings limit usage with amplitude modulation at medium frequencies (530-1610 kHz) or pulsed usage, while average-power ratings limit the high frequency usage. Peak-Power Rating The peak-power rating of a transmission line is limited by voltage breakdown between the inner and outer conductors. Voltage breakdown is essentially independent of RF frequency, but varies with line pressure and type of pressurizing gas. Peak-power ratings are, therefore, generally stated for the following standard conditions: VSWR = 1.0, zero modulation and one atmosphere absolute dry air pressure (0 lb/in2 or 0 kPa gauge) at sea level. The peak-power rating of the selected cable must be derated for modulation technique and VSWR, as follows: Peak Power Derating for Modulation and VSWR
Modulation AM FM and DTV Analog TV Peak Power Derating Calculation PMAX = PMAX = PMAX = PPK (1+M)2 VSWR PPK VSWR PPK = (1+AU+2AU) VSWR PPK (2.09) VSWR
Rated transmitter power must be less than calculated derated peak power of the cable for safe operation. For digital TV (DTV), peak power is typically 7dB higher than average power. From derating expressions, it can be seen that 100% amplitude modulation increases the peak power in the transmission line by a factor of 4. Also, the peak power in the transmission line increases directly with VSWR. The transmission line peak-power rating can be significantly increased by pressurization. See page 633 for details. An adequate safety factor on peak power is necessary to safeguard against voltage breakdown which can result in permanent damage to the transmission line. All HELIAX semiflexible coaxial cables are high-voltage tested to the equivalent of 200% of their rated peak powers (safety factor of 1.4 on voltage), and all rigid coaxial lines to the equivalent of 400% of rated peak powers (safety factor of 2.0 on voltage). These safety factors are intended as a provision for transmitter transients, lightning induced transients, and high voltage excursions due to other unforeseen causes. Andrew is known for its conservative specifications that insure long term, reliable performance. We continue to hold this commitment to our customers by maintaining the highest level of quality and performance. HELIAX peak-power ratings are determined according to the relation: PPK =
(E x 0.707 x 0.7) SF
P
ZC Where: PPK EP 0.707 0.7 SF = = = = = Cable power rating, standard conditions dc production test voltage RMS factor dc to RF factor (empirically verified) Safety factor on voltage = 1.4 for HELIAX semiflexible cables = 2.0 for rigid coaxial lines = Characteristic impedance
Where: PMAX PPK M VSWR AU 2.09 = = = = = = Derated peak power Peak power rating of cable Amplitude modulation index (100% = 1.0) Voltage standing wave ratio Aural to visual ratio (20% Aural: AU = 0.2) Modulation derating factor for TV, for AU=0.2
ZC
632
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
.5
P' = Rating at new Amb. Temp. P = Rating at Normal Amb. Temp. of 40C
10
15
2
20
25
30
0 -50
50
100
150
200
Ambient Temperature, C
Typical dc production test voltages for various sizes of semiflexible coaxial cable and rigid line are shown below.
Impedance ohms 50 50 50 50 50 50 50 50 50, 75 75 75 Ep, kV Flexible cables 6 9 11 13 16 21 27.5 Ep, kV Rigid lines 11 19 36 41.8 47
DC Test Voltage kV 1.0 1.5 1.5 2.0 2.0 4.0 4.2 4.0 2.5 5.0 6.0 11 19 21 27.5
Average Power kW* 0.1 0.1 0.3 0.3 0.6 0.6 1.2 1.3 1.2 3.5 1.7 4.9 16 27 57
Nominal size 7/8" 1-1/4" 1-5/8" 2-1/4" 3" 3-1/8" 4" 5" 6-1/8" 7-3/16" 8-3/16"
Average power ratings of the connector interfaces are based on an operating frequency of 900 MHz. The values shown in this table are typical for most applications.
Foam-dielectric cables have a greater dielectric strength than air-dielectric cables of similar size. For this reason they might be expected to have higher peak-power ratings than air cables. Higher peak-power ratings usually can not be realized, however, because the commonly used connectors for foam cables have air spaces at the cable/connector interface which limit the allowable RF voltage to air cable values. Andrew rates similar size foam- and air-dielectric cables alike for this reason. Effect of Connector on Power Rating The peak power handling capability of a cable assembly is the smaller of the values for the cable and the connectors. The following table shows power ratings for common connectors at standard conditions of VSWR = 1.0, zero modulation and one atmosphere dry air pressure (0 lb/in2 or 0 kPa gauge) at sea level.
Increased Peak Power Ratings Pressurization and/or the use of high-density gases with high dielectric strength can be used to increase peakpower ratings. These effects are shown in Figure 3. For a given transmission line pressure, the increase in peak-power rating is significant. For example, a line pressure of 10 lb/in2 (70 kPa) dry air increases the peak-power rating by a factor of 1.9. Pressurization above 30 lb/in2 (207 kPa) is not recommended. Average Power Rating Average power ratings for semiflexible cables are determined by the maximum permissible inner conductor temperature. This maximum temperature depends on the type of dielectric, and is governed by considerations of the long-term life of the dielectric. Average power ratings for rigid coaxial lines are also determined by the maximum inner conductor temperature. For rigid lines this maximum temperature is set primarily by considerations of differential expansion of inner and outer conductors, and the maximum movement permissible at the joints (inner connectors).
Visit us at: www.andrew.com
633
Figure 6 Variation of Average Power Rating with Intensity of Direct Solar Radiation
1.0 (200C) 0.9
7/8" 1-5/8" - 2-1/4" 3" and 3-1/8" 4" and 5" 6-1/8" -- 8-3/16"
(121C) 0.8 (100C) 0.7 Rated Inner Conductor Temperatures 100C (212F) LDF Foam Cables. H4, H5, H7, H9, H12 Air Cables 0.5 121C (250F) H8, H11 Air Cables 200C (392F) HT4, HT5, and HLT4-50T Air Cables 0.4 0 200 400 600 800 1000
0.6
Andrew average power ratings are based on a VSWR of 1.0, atmosphere pressure and ambient temperature of 40C (104F). Derating Average Power for Modulation Condition To convert rated transmitter power to average power for analog television transmission, multiply by 0.8 (totally black picture + aural signal). For FM radio and digital television (DTV), the factor is 1.0. Transmission lines for AM radio at MF frequencies (530-1610 kHz) are usually peak power limited. At higher (HF) frequencies, the limitation is average power capability and the required derating factor, D.F., is:
2 D.F. = 1 + M 2
For example: Calculate power rating for 3" HJ8-50B cable operating at 100 MHz with VSWR = 1.1, F1 (from Figure 5) = 0.33: D.F. = 2 x 1.1 1.12 x (1 + 0.33) + 1 - 0.33 = 0.965
Average Power Rating at 1.00 VSWR = 42.4 kW (from page 566) Average Power Rating at 1.1 VSWR = 42.4 x 0.965 = 41.0 kW Derating Average Power for Direct Solar Radiation The average power handling capability of a cable exposed to direct solar radiation will be reduced. The appropriate derating factors for the different cable types are shown in Figure 6. The average radiation intensity for moderate climates is 200 W/m2 or less. Hot, dry climates give solar radiation intensities which at the hottest time of the day can be 1,000 W/m2 or higher. The mean value over the day, which is applicable to average power derating calculations provided absolute maximum temperatures are not exceeded, is up to 400 W/m2. These hot, dry locations are also subject to elevated ambient temperatures, which must also be considered (Figure 4).
where M is the modulation depth (100% = 1.0), expressed decimally. Average Power Rating Adjustment for Ambient Temperature The baseline power rating can be adjusted to meet the actual usage conditions. Figure 4 shows the variation of average power rating with ambient temperature. Derating Average Power for VSWR The derating factor (D.F) is calculated from the following formula: D.F. = 2 (VSWR) VSWR2 (1 + F1) + 1 - F1
where F1 is a factor that varies with frequency and line size. This calculation of derating factor is conservative in that it assumes all reflected power is re-reflected at the transmitter and absorption of the reflected signal by the line attenuation is small. Select the factor from the applicable curve in Figure 5, calculate factor D.F., and multiply by the average power from the cable characteristics table.
634
Customer Service Center - Call toll-free from: U.S.A., Canada and Mexico 1-800-255-1479
7.9
100
200 Miles
Values for average direct solar radiation for locations in the USA are shown in Figure 7. For conversion purposes, to determine a derating factor from Figure 6 from the information by location from Figure 7, 1 MJ/m2 over a 24-hour period is equivalent to 11.6 W/m2. Derating Average and Peak Powers for Altitude Derating factors for average and peak powers with altitude are shown in the following table. These factors have been determined assuming just nominal overpressure inside the transmission line. Both average and peak powers must be derated because the lower atmospheric pressure with increasing altitude reduces both heat transfer from inner and outer conductors, and the dielectric strength of the air inside the line.
Derating Average and Peak Powers for Altitude Altitude above Sea Level ft (m) 0 (0) 5000 (1524) 8000 (2438) 10500 (3200) 15000 (4572) P1/P Average Power 1.00 0.92 0.87 0.84 0.78 P1/P Peak Power 1.00 0.69 0.53 0.44 0.30
Efficiency The efficiency of a transmission line depends on its length and attenuation. The efficiency is defined as the percent of transmitter power which reaches the antenna. It can be calculated as: Efficiency = 100% 10 (dB) 10 where dB is the total attenuation of the transmission line at the frequency of interest. The remaining power is lost in the transmission line and is dissipated as heat.
635