0% found this document useful (0 votes)
85 views

International Limited International Limited: JC JC

1. This is a heavy weight drill pipe inspection report for Seadrill (West Capella) conducted by JC International Limited at their base location. 2. The inspection included a visual inspection of the tubes and connections, MPI slip/upset testing, blacklight inspection of connections, and dimensional measurements. 3. Of the 5 pieces of 5.7/8" heavy weight drill pipe inspected, 2 were rejected - one due to a bent tube and galled thread connection, and another due to a belled out box and galled thread pin connection. The other 3 pieces were found to be acceptable.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views

International Limited International Limited: JC JC

1. This is a heavy weight drill pipe inspection report for Seadrill (West Capella) conducted by JC International Limited at their base location. 2. The inspection included a visual inspection of the tubes and connections, MPI slip/upset testing, blacklight inspection of connections, and dimensional measurements. 3. Of the 5 pieces of 5.7/8" heavy weight drill pipe inspected, 2 were rejected - one due to a bent tube and galled thread connection, and another due to a belled out box and galled thread pin connection. The other 3 pieces were found to be acceptable.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JC International Limited RC.

413243

Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: [email protected] Website: www.jcinternationalng.com

HEAVY WEIGHT DRILL PIPE INSPECTION REPORT

ROTARY SHOULDER CONNECTIONS

CUSTOMER:

SEADRILL (WEST CAPELLA)

RIG:

LOCATION: JCI BASE

W.O.NO.

P.O. No.:

W.O. No.:

REPORT NO.
HEAVY WEIGHT SIZE: 5.7/8" H.W.D.P CONNECTION: 5.1/2 FH VAM EIS

2905

DATE:20-03-20112

INSPECTION PROGRAME:

VISUAL TUBE, VISUAL CONNECTION, MPI SLIP/UPSET, BLACKLIGHT CONNECTION, DIMENSIONAL 3


SPECIFICATION:

DS-1 STANDARD.
CATEGORY

1
ALL DIMENSIONS IN INCHES BOX TOOL JOINT PIN TOOL JOINT

3-5

CENTER WEAR PAD

IDENTIFICATION NO

TUBE COND.

LENGTH (FT)

OD

HB COND

Bevel Dia.

Seal Width

Counterbore Dia Depth

Boreback Length Dia

Lead Gauge

Tong Space

Cond

MPI Upset

ID

OD

HB OD

Bevel Dia.

Neck Length

SRG Width Dia

Lead Gauge

Tong Space

Cond

MPI Upset

Side OD Box Side


ACC ACC ACC ACC

Pin Side
ACC ACC ACC ACC ACC

MPI Box Pin Side Side


ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC

118458 118486 118480 118480 118483

ACC BENT ACC ACC ACC

30.43 30.42 30.42 30.33 30.35

7 7 7 7 7

ACC ACC ACC ACC ACC

6.29/32 6.29/32 6.29/32 6.29/32 6.29/32

3/8 3/8 3/8 3/8 3/8

5.15/16 5.15/16 5.15/16 5.15/16 5.15/16

5/8 5/8 5/8 5/8 5/8

20.9/16 BELLED BOX ACC 20.1/2 20.5/8 20.3/4 19.1/2 ACC G/T ACC ACC ACC ACC ACC ACC

4 4 4 4 4

7 7 7 7 7

ACC ACC ACC ACC ACC

6.11/16 6.11/16 6.11/16 6.11/16 6.11/16

3/4 3/4 3/4 3/4 3/4

NA NA NA NA NA

NA NA NA NA NA

21 21 21 21 21

G/T G/T ACC G/T ACC

OK OK OK OK OK

6.3/8 6.3/8 6.3/8 6.3/8 6.3/8

ACC

Max Reqd. Min. Reqd.

SD = Seal Damage TD = Thread Damage BB = Belled out Box ST = Streched Thread GT = Galled Thread

CRK = Crack WO = Wash Out CS = Corroded Seal CT = Corroded Thread STJ = Short Tool joint

RF = Refaced ACC = Acceptable REJ = Rejected N/A = Not Applicable HB = Hard Band

LENGTHS READY FOR USE LENGHTS WITH PIN CONN. REJECTED LENGHTS WITH BOX CONN. REJECTED LENGHTS WITH PIN & BOX CONN. REJECTED TOTAL LENGTH INSPECTED

1 2 1 1 5

CONNECTIONS REFACED

COMMENTS: NO 2 WITH SN 118486 IS BENT & PIN G/T. NO 1 WITH S/N 118458 IS BELLED OUT BOX & PIN G/T. NO 3 IS ACCEPTABLE FOR USE AS AT THE TIME OF INSPECTION. NO 4 IS PIN GALLED THREAD. NO 5 IS ACCEPTABLE FOR USE AS AT THE TIME OF INSPECTION 20/03/2012
DATE:

CUSTOMER SIGNATURE:..

INSPECTOR:

SIMON OGAB

ASNT LEVEL II

Member