0% found this document useful (0 votes)
59 views1 page

Electrical

This document contains 5 questions related to analyzing three-phase circuits. Question 1 asks about the relationship between phase and line voltages/currents in star and delta connected circuits. Question 2 involves calculating phase/line currents and power absorbed for inductive coils in star and delta configurations. Question 3 requires determining line current, power factor, and power for a mesh-connected balanced load. Question 4 involves calculating power and power factor using two wattmeter readings, one with the current coil reversed. Question 5 requires calculations based on a star-connected balanced load with given phase current/voltage and angle between them.

Uploaded by

Ritu Kapoor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views1 page

Electrical

This document contains 5 questions related to analyzing three-phase circuits. Question 1 asks about the relationship between phase and line voltages/currents in star and delta connected circuits. Question 2 involves calculating phase/line currents and power absorbed for inductive coils in star and delta configurations. Question 3 requires determining line current, power factor, and power for a mesh-connected balanced load. Question 4 involves calculating power and power factor using two wattmeter readings, one with the current coil reversed. Question 5 requires calculations based on a star-connected balanced load with given phase current/voltage and angle between them.

Uploaded by

Ritu Kapoor
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

UEE101

(Three phase circuits)

DEPARTMENT OF ELECTRICAL AND INSTRUMENATION ENGINEERING UES 001 ELECTRICAL AND ELECTRONICS SCIENCE

TUTORIAL 8 Course Instructor : Shakti Singh Q1.Deduce the relationship between the phase and line voltage and current in three phase star and delta connected circuits. Q2.Three inductive coils, each with a resistance of 15 ohm and an inductance of 0.03H are connected in (a) star and (b) delta, to a 3 phase supply of 400V. 50Hz supply .Calculate for each of the above case (i) Phase current (13,22.6) (ii) Line current (13,39.14) (iii)Total power absorbed.(7.632W, 22968W) Q3.A balanced mesh connected load of (8+j6) ohm per phase is connected to a 3 phase, 50Hz, 230V supply system. Calculate (i) Line current (ii) Power factor (iii)Power (iv)Total volt ampere {40A, 0.8, 12.7kW, 15.9kVA} Q4.Two wattmeter connected to measure the power input to a 3 phase circuit indicate 15 and 1.5kW respectively. The latter reading being obtained after reversing the current coil connection. Calculate the power and power factor of the load. (13.5, .427) Q5.A balanced star connected load is supplied from a symmetrical, 3 phase, 440V, 50Hz supply system. The current in each phase is 20 A and lags behind its phase voltage by an angle of 40, calculate (i) Phase voltage (ii) Load parameter (iii)Total power (iv)Reading of two wattmeter, connected in load circuit to measure total power. (254V, R=9.73, X=8.16, 11.6745, W1= 8.665 kW, W2=3.009kW)

You might also like