How To Use Pathloss
How To Use Pathloss
DESCRIPTION ON
HOW TO USE PATHLOSS SOFTWARE AS A COMPLETE MICROWAVE SYSTEM PLANNER
Contents 1- Required Software 1.1- Necessary Data for Microwave Network Design & How to place it in your PATHLOSS Program 2- How to operate PATHLOSS 2.1- Sites Data Entry & Creation of Network 2.2- Link by Link PATHLOSS Files Creation 2.3- Terrain Data & Obstruction Entry 2.4- Finding Suitable Antenna Heights 2.5- Link Budget Calculations 2.6- Frequency Interference Calculations for The Network
1- Required Software 1.2- Necessary Data for Microwave Network Design & How to place it in your PATHLOSS Program
The followings data must be placed in PATHLOSS program folder to be able to use the program as a full Microwave system Planner 1- Rain File 3- Gopo30303 (Terrain Data File) 2- Equipment File
Fig. 1.2.1
EXPLANATION ABOUT HOW TO USE THIS DATA WILL COME IN (2.5 LINK BUDGET CALCULATIONS)
Fig. 1.2.2
Fig. 1.2.3
2- Equipment
This folder contents 4 folders but for our Microwave design we just use 2 folders as the followings 1- MAS which contents Microwave Antenna Data for different Antenna Manufacturer (Andrew , RFS , ERICSSON , ..) as shown in Fig. 1.2.4 2- MRS which contents Microwave Radio Data for different Manufacturers NOTE: We just concern of NEC Equipment which is not included with our PATHLOSS software. NEC data will be attached with this documents as Soft copy so please kindly place it in your PATHLOSS folder (inside MRS folder) to be used As shown in Fig. 1.2.5 NOTE: EQUIPMENT FOLDER IS AVAILABLE ON PATHLOSS PROGRAM CD. SO PLEASE KINDLY COPY TO YOUR PATHLOSS FOLDER EXPLANATION ABOUT HOW TO USE THIS DATA WILL COME IN (2.5 LINK BUDGET CALCULATIONS)
Fig. 1.2.4
Fig. 1.2.5
Fig. 1.2.6
Fig. 1.2.7
Fig. 1.2.8
Fig. 1.2.9
Fig. 2.1.1
2.1.2- In Network screen Click on Site Data & choose Site List as shown in Fig. 2.1.2
Fig. 2.1.2 2.1.3- In Site List Page Click on Edit then Add as shown in Fig. 2.1.3
Fig. 2.1.3
2.1.4- Inter Site Name, Call Sign (Station ID. This is important for Frequency Interference calculations. So if there is not Station ID you can give numbers for each station as Example 1 , 2, 3,.) , Latitude & Longitude then click OK as shown in Fig. 2.1.4
Fig. 2.1.4 2.1.5- Repeat steps 2.1.3 & 2.1.4 to enter other sites data then close Site List Page. Then you get Map grid with locations, Names of the entered sites data as shown in Fig. 2.15
Fig. 2.1.5
2.1.6- Connect between stations according to actual links configuration by press & drag from site to opposite site as shown in Fig. 2.1.6 Then repeat the above to connect all the links
2.2- Link by Link PATHLOSS Files Creation After we finished of all sites data entry & making the link connections correct according to actual links configuration we have to go through link by link & create its pathloss file as the followings
2.2.1- Press on the link & click Summary as per shown in Fig. 2.2.1 2.2.2- In Summary Page Inter the design frequency band as shown in Fig. 2.2.2 2.2.3- Save this file in the same folder you saved the network 2.2.4- Repeat the above for the other links
Fig. 2.2.1
Fig. 2.2.2
2.3.3- Enter Obstructers by clicking on Structure position. Then choose structure type (Tree, Building or Water Tower). Enter this structure height in meters as per shown in Fig. 2.3.3 2.3.4- Repeat the above for the other obstacles
Fig. 2.3.3
Fig. 2.4.1
2.4.2- In Antenna Height page click on Optimize to get optimize antenna height for reference only as shown in Fig. 2.4.2
Fig. 2.4.2 2.4.3- The above Antenna is only for reference while the final antenna height will be decided according to the actual tower conditions & space availability 2.4.4- Go to Summary page & enter antenna heights which you think it will have clear LOS according to your path survey (mirror test or any other physical check) as shown in fig. 2.4.3 2.4.5- Go to Print Profile page from Module menu or by pressing ctrl P to confirm that link Fresnel zone has clear LOS above obstacles as shown in Fig. 2.4.5 2.4.6- If antennas heights which you entered still low to get clear LOS. Increase antenna height again according to available tower height till you get clear LOS with enough margin above obstacles
Fig. 2.4.3
Fig. 2.4.5
Fig. 2.5.1 2.5.2- Enter Point frequency & polarization at each site by pressing on Ch. Then click OK As shown in Fig. 2.5.1 & 2.5.2
Fig. 2.5.2
2.5.3- Select Radio Equipment type by clicking on TR you will get Radio Equipment page as shown in Fig. 2.5.3
Fig. 2.5.3 2.5.4- click on Code Index then New Index. Go to your pathloss folder Equipment MRS NEC (where you placed NEC equipment folder) as shown in Fig. 2.5.4
Fig. 2.5.4
2.5.5- Select your radio according to Type (3000S , Pasolink , Pasolink+ , ..) , Frequency ban (7G , 8G , 11G, .) Modulation (16 QAM , 32 QAM , 128 QAM,.) Capacity (PDH x E1 , STM-0 , STM-1) then click Both to set same Radio for both stations then Press OK as shown in Fig. 2.5.5
Fig. 2.5.5 2.5.6- Set Branching Circuit or Hybrid Loss by clicking on its Symbol (above TR) then press OK as shown in Fig. 2.5.6
Fig. 2.5.6
2.5.7- Enter Feeder Data & connection losses by pressing on Wave Guide symbol then kick OK as shown in Fig. 2.5.7
Fig. 2.5.7 2.5.8- Select antenna type for each station by clicking on antenna symbol then press as shown in Fig. 2.5.8
Fig. 2.5.8
2.5.9- Press on Code Index then New Index then brows for pathloss folder (where you placed it) Equipment MAS Antenna manufacturer (Andrew, RFS, ..) Frequency Range (102-132 , 122 132 , 142 153 , .)then press OK as shown in Fig. 2.5.9
Fig. 2.5.9 2.5.10- Select antenna for site 1 & press on Site 1 & select antenna for site 2 & press Site 2 or in case of both sites have same antenna press on Both. The press Close OK as shown in Fig. 2.5.10
Fig. 2.5.10
2.5.11- Set Reliability Method In worksheet page go to Operation Menu reliability Methods as per attached in Fig. 2.5.11
Fig. 2.5.11 Set Reliability criteria as per shown in Fig. 2.5.11-1 for SDH or as Project & Customer requirement & press OK
Fig. 2.5.11.1
2.5.12- Set of Rain factor Press on Rain symbol select ITU-R-P-530. 6/8 press Load Rain File Select Rain area according to ITU-530 Map Fig. 1.2.3 (Rain Files are placed in Pathloss folder Rain) Press Close as per shown in Fig. 2.5.12
Fig. 2.5.12 2.5.13- Set Geoclimatic Factor Press on the Ground Symbol (as shown in Fig. 2.5.13-1) Set Geoclimatic Factor according to ITU-R-P-453 as Shown in Fig. 2.5.13-2)
Fig. 2.5.13-1
Fig. 2.5.13-2
2.5.14- Make sure of either our Path Calculation is correct or we need to revise again. To do that please check the followings - Make sure that your worksheet page has Green Correct sign in Right Bottom of screen. If it is wrong sign that's mean there are some data mistake - Have a look to RX Signal, Fade Margin & (Annual Availability with rain) Percentage as per shown in Fig. 2.5.14
Fig. 2.5.14 If any of (RX, Margin, Availability) is less than the required to meet the Spec. & recommendations. You have to increase antenna diameter or add Space Diversity Radio to reach to the required Spec. So you go to step 2.5.10 again & select new antennas
2.5.15- After finish of path calculations go to Report Menu in Worksheet page click Full Report You will get full path calculation report as below one. You can copy it to Word or Excel sheet & save it for reference & submitting with your survey report
Microwave Worksheet - Vika Spuri-Nangoli.pl4 Vika Spuri Nangoli Elevation (m) 211.00 210.84 Latitude 28 38 24.30 N 28 40 54.20 N Longitude 077 04 28.80 E 077 04 11.20 E True azimuth () 354.09 174.09 Vertical angle () -0.02 -0.01 Antenna model VHP6-142 VHP6-142 Antenna height (m) 0.00 0.00 Antenna gain (dBi) 46.00 46.00 TX line length (m) 0.60 0.60 TX line unit loss (dB /100 m) 100.00 100.00 TX line loss (dB) 0.60 0.60 Circ. branching loss (dB) 3.50 3.50 Frequency (MHz) 15000.00 Polarization Vertical Path length (km) 4.64 Free space loss (dB) 129.32 Atmospheric absorption loss (dB) 0.13 Net path loss (dB) 45.65 45.65 Radio model PASOLINK+ 15G 155MB PASOLINK+ 15G 155MB TX power (watts) TX power (dBm) EIRP (dBm) TX Channels RX threshold criteria RX threshold level (dBm) RX signal (dBm) Thermal fade margin (dB) Geoclimatic factor Path inclination (mr) Average annual temperature (C) Worst month - multipath (%) (sec) Annual - multipath (%) (sec) (% - sec) Rain region 0.01% rain rate (mm/hr) Flat fade margin - rain (dB) Rain rate (mm/hr) Rain attenuation (dB) Annual rain (%-sec) Annual multipath + rain (%-sec) , 10 1424 Reliability Method - ITU-R P.530-7/8 Rain - ITU-R P530-7 0.04 0.04 16.50 16.50 58.40 58.40 1 14543.0000V 1' 14963.0000V BER 10-6 BER 10-6 -67.50 -67.50 -29.15 -29.15 38.35 38.35 1.77E-04 0.03 30.00 99.99993 99.99993 1.88 1.88 99.99997 99.99997 8.48 8.48 99.99995 - 16.95 ITU Region N 95.00 38.35 186.44 38.35 99.99916 - 264.20 99.99911 - 281.15
Fig. 2.6.1 Have a look to your network & make sure that all links Frequencies & Polarizations are correct according to your plan. If there is any mistake in any link please go to its work sheet & make it correct 2.6.2- Go to Interference Menu & Click Calculate Intra as per shown in Fig. 2.6.2
Fig. 2.6.2 2.6.3- Set the Interference Calculation criteria according to Specs. & press Calculate as per shown in Fig. 2.6.3
Fig. 2.6.3
Fig. 2.6.4 2.6.5- You will get Interferences cases as below example. Study carefully those interference cases & if any one of them is dangerous case please re-plan you network frequencies or change your antenna type to higher XPD antennas. Also you can use ATPC function to keep lower TX power which will help to avoid some interference cases
Interference Cross Reference - Bharti Delhi (final).gr4 Coordination Distance (km) 100.00 obj objective (dBm) Maximum frequency Separation (MHz) 28.00 v-i path length (km) Default Minimum Interference Level (dBm) -105.00 tad discrimination (dB) Margin (dB) 10.00 ifl (dBm) Threshold degradation objective (db) 3.00 td Degradation (dB) Total number of cases calculated 87 * Calculation made on , 10 1424 09:46:00 Interference level Victim to interferer Total antenna Interfering Signal Threshold OHLOSS
Case 1 Charmwood (Okhla), VHP4A-142, 14963.0000H, STM1-128QAM, obj = -98.6 1-1 Faridabad (Charmwood), VHP2-142, 14963.0000V, STM1-128QAM, v-i = 3.3, tad = 70.0 (i 0.0 v -191.9), ifl = -102.0 (3.5), td = 1.6 1-2 Okhla (Sarita Vihar), VHP2-142, 14963.0000V, STM1-128QAM, v-i = 3.5, tad = 68.0 (i 128.8 v 0.0), ifl = -100.2 (1.7), td = 2.2 Case 2 Okhla (Charmwood), VHP2-142, 14543.0000H, STM1-128QAM, obj = -98.6 2-1 Charmwood (Faridabad), VHP4A-142, 14543.0000V, STM1-128QAM, v-i = 3.5, tad = 67.0 (i 191.9 v 0.0), ifl = -99.1 (0.5), td = 2.7 2-2 Faridabad19 (Faridabad), VHP2-142, 14543.0000V, STM1-128QAM, v-i = 11.0, tad = 52.2 (i -5.7 v -2.3), ifl = -100.3 (1.7), td = 2.2 *
2-3 Sarita Vihar (Okhla), VHP2-142, 14543.0000V, STM1-128QAM, v-i = 2.0, tad = 68.0 (i 0.0 v -128.8), ifl = -101.4 (2.9), td = 1.8 Case 3 Faridabad (Charmwood), VHP2-142, 14543.0000V, STM1-128QAM, obj = -98.6 3-1 Charmwood (Okhla), VHP4A-142, 14543.0000H, STM1-128QAM, v-i = 3.3, tad = 70.0 (i -191.9 v 0.0), ifl = -101.8 (3.2), td = 1.7 3-2 Faridabad19 (Faridabad), VHP2-142, 14543.0000V, STM1-128QAM, v-i = 4.2, tad = 62.0 (i 0.0 v -164.7), ifl = -102.0 (3.4), td = 1.6 3-3 Shalimar Bagh (Wazipur), VHP4A-142, 14543.0000V, STM1-128QAM, v-i = 31.4, tad = 30.1 (i 9.4 v 1.0), ifl = -81.5 (-17.0), td = 17.1 * 3-4 Kamal Hotel (Gopala Tower), VHP2-142, 14543.0000H, STM1-128QAM, v-i = 25.2, tad = 48.3 (i -38.8 v -0.5), ifl = -103.8 (5.2), td = 1.1 * Case 4 Charmwood (Faridabad), VHP4A-142, 14963.0000V, STM1-128QAM, obj = -98.6 4-1 Okhla (Charmwood), VHP2-142, 14963.0000H, STM1-128QAM, v-i = 3.5, tad = 67.0 (i 0.0 v 191.9), ifl = -99.3 (0.8), td = 2.6 4-2 Faridabad (Faridabad19), VHP2-142, 14963.0000V, STM1-128QAM, v-i = 3.3, tad = 62.0 (i 164.7 v 0.0), ifl = -94.1 (-4.4), td = 5.7 Case 5 Faridabad19 (Faridabad), VHP2-142, 14963.0000V, STM1-128QAM, obj = -98.6 5-1 Okhla (Charmwood), VHP2-142, 14963.0000H, STM1-128QAM, v-i = 11.0, tad = 52.2 (i -2.3 v -5.7), ifl = -100.5 (2.0), td = 2.1 * 5-2 Faridabad (Charmwood), VHP2-142, 14963.0000V, STM1-128QAM, v-i = 4.2, tad = 62.0 (i -164.7 v 0.0), ifl = -102.2 (3.7), td = 1.6 5-3 Touch Tel (Faridabad19), VHP4A-142, 14963.0000H, STM1-128QAM, v-i = 4.4, tad = 68.0 (i 0.0 v -170.3), ifl = -102.5 (3.9), td = 1.5 5-4 Mayur Vihar Ph-3 (Noida Sec10), VHP2-142, 14963.0000H, STM1-128QAM, v-i = 20.6, tad = 50.3 (i 1.3 v -341.0), ifl = -104.2 (5.6), td = 1.0 * Case 6 Faridabad (Faridabad19), VHP2-142, 14543.0000V, STM1-128QAM, obj = -98.6 6-1 Charmwood (Faridabad), VHP4A-142, 14543.0000V, STM1-128QAM, v-i = 3.3, tad = 62.0 (i 0.0 v 164.7), ifl = -93.9 (-4.7), td = 5.9 6-2 Faridabad19 (Touch Tel), VHP2-142, 14543.0000H, STM1-128QAM, v-i = 4.2, tad = 68.0 (i 170.3 v 0.0), ifl = -108.0 (9.4), td = 0.5 Case 7 Touch Tel (Faridabad19), VHP4A-142, 14543.0000H, STM1-128QAM, obj = -98.6 7-1 Faridabad19 (Faridabad), VHP2-142, 14543.0000V, STM1-128QAM, v-i = 4.4, tad = 68.0 (i -170.3 v 0.0), ifl = -102.2 (3.7), td = 1.5 7-2 Vaishali (Mayur Vihar Ph-3), VHP4A-142, 14543.0000V, STM1-128QAM, v-i = 28.5, tad = 50.7 (i 0.7 v -352.4), ifl = -95.1 (-3.5), td = 5.1 * Case 8 Faridabad19 (Touch Tel), VHP2-142, 14963.0000H, STM1-128QAM, obj = -98.6 8-1 Faridabad (Faridabad19), VHP2-142, 14963.0000V, STM1-128QAM, v-i = 4.2, tad = 68.0 (i 0.0 v 170.3), ifl = -108.2 (9.7), td = 0.4