This document is an electrical diagram for a local control panel. It shows the wiring for push buttons, relays, contactors, and indicators for controls including start, stop, emergency stop, remote start, transformer on/off, lamp test, and input from a power unit. It also shows wiring for field trips, process trips, and a hooter or alarm. The diagram is labeled with terminal identifications and includes a legend for symbols.

Uploaded by

satindia
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
156 views

Control Circuit Diagram

This document is an electrical diagram for a local control panel. It shows the wiring for push buttons, relays, contactors, and indicators for controls including start, stop, emergency stop, remote start, transformer on/off, lamp test, and input from a power unit. It also shows wiring for field trips, process trips, and a hooter or alarm. The diagram is labeled with terminal identifications and includes a legend for symbols.

Uploaded by

satindia
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

VETRI ENGINEERS

E & IA DIVISION, COIMBATORE


A
> To be use d for clie nt a pprova l whe re a pplica ble .
LEGENT FOR SYMBOLS
RELAY
VENDOR DOCUMENT REVIEW
A - REVIWED WITH NO
B - REVIWED WITH
C - DO NOT PROCEED WITH
FABRICATION
D - RECEIVED AS INFORMATION
SCALE
NTS
DOC / DWG No. SHEET NO.
TITLE:
PUSH BUTTON
APPD
CONTROL CIRCUIT FOR LOCAL CONTROL PANEL
CHKD PRED DESCRIPTION DATE REV.
P
N
EMG
STOP
REMOTE STOP
OLR 1
R1 - 1
START
PB
K1
REMOTE
START
K
FROM
CONTROL
TRANSFORMER
T
R
A
N
S
F
O
R
M
E
R
O
N
T
R
A
N
S
F
O
R
M
E
R
O
F
F
TEST
R7
LAMP TEST
PB
T
O

A
N
N
P
O
W
E
R

S
U
P
P
L
Y
HOOTER
R
1

-

2
O
L
R

3
TO CLIENT DCS :
R1 - 3 OLR 4
TO ANNOUNCIATOR :
TRANSFORMER
ON
TRANSFORMER
OFF
STOP PB
NORMALLY CLOSED
NORMALLY OPEN
PILOT LAMP
HOOTER
TERMINALS
R

H
E
A
L
T
H
Y
INKAL VENTURES
K
CONTACTOR
SAK ISSUED FOR REVIEW / APPROVAL 09/ 02/ 2012 00
Rr
1
Ry
1
Rb
1
1005PS-001-DW-1590-003 03 of 05
OLR 5
TRANSFORMER
ON
TRANSFORMER
OFF
INPUT FROM POWER UNIT:
COMMENTS
COMMENTS & NOTED
LSL - 001
PSH - 001
TSH - 001
TSH - 002
NKA
FIELD TRIPS
R1
LOW LEVEL TRIP
Y

H
E
A
L
T
H
Y
B

H
E
A
L
T
H
Y
R
6

-

2
R
6

-

1
K 2
K
A
2 K
A
1 K
A
3 K
A
4 K
A
5 K
A
6 K
A
T
R
I
P

(
O
R
A
N
G
E
)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
TEST
R6
ALLS - 2601
120V, 50HZ
AC SUPPLY
Mfg. by SAI INDUSTRIES, VAPI
B
C
D
E
F
G
A
B
C
D
E
F
G
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10
NKA
PROCESS TRIP:
R3
R4 R2
R5
R2 - 1
R3 - 1
R4 - 1
R5 - 1
R
2

-

2
R
3

-

2
R
4

-

2
R
5

-

2
R2 - 3 R3 - 3 R4 - 3
R1 - 4 R2 - 4 R3 - 4 R4 - 4
ALLS - 2601
R
7

-

1
R
6

-

4
R
6

-

3
LOW LEVEL TRIP
ALLS - 2601
R5 - 3
R5 - 4
P
R
O
C
E
S
S

T
R
I
P
R
7

-

2
RESET
RESET
SAK RE-ISSUED FOR REVIEW / APPROVAL 03/ 03/ 2012 01 NKA NKA
RE-ISSUED FOR REVIEW / APPROVAL 26/ 04/ 2012 02 SAK NKA NKA
K
B
Kb
1
21
STOP
RESET