0% found this document useful (0 votes)
23 views

JC International Limited: Certificate of Visual Examination and Mpi

This document provides a certificate of visual examination and magnetic particle inspection for a BX-3 hydraulic elevator. The inspection was performed on August 9, 2011 by Olatunji Akinlade and found no cracks, though minor laminations were present on both ears, within acceptance criteria. The elevator is owned by Seadrill and was inspected at the JCI base using their test procedure JOP-020 with no defects found, certifying it as fit for use.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views

JC International Limited: Certificate of Visual Examination and Mpi

This document provides a certificate of visual examination and magnetic particle inspection for a BX-3 hydraulic elevator. The inspection was performed on August 9, 2011 by Olatunji Akinlade and found no cracks, though minor laminations were present on both ears, within acceptance criteria. The elevator is owned by Seadrill and was inspected at the JCI base using their test procedure JOP-020 with no defects found, certifying it as fit for use.

Uploaded by

Michael Okwuwa
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

JCI

JC International Limited RC 413243


Plot 5 JC Street, Off Peter Odili Road, Trans Amadi, P.O. Box 6427 Trans Amadi Port Harcourt TEL: 234-084-489909, 08033108342, E-mail: [email protected] Website: www.jcinternationalng.com

CERTIFICATE OF VISUAL EXAMINATION AND MPI


Certificate No. 1036 Identification Number Date of Examination 08/09/11 Examiner OLATUNJI AKINLADE Qualifications SNT LEVEL II MT, PT & UT

Description of Equipment:

BX-3 HYDRAULIC ELEVATOR

NL 92844

DIMENSIONS Right Ear: Left Ear: 4.15/16 4.31/32

SIZE: 9.5/8 20 SWL: 350TONS

MANUFACTURER- CGS
Next Date of Examination: 07/03/12 METHOD: All accessible areas were subjected to a magnetic particle testing. No crack

or crack-like indication was found. NOTE: Lamination was found on both left and right ear, but still within
acceptance Criteria
SPECIFICATION : API RP 8B MPI METHOD: WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET SERIAL NO. : 43254 COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) Name and address of equipment owner: SEADRILL Address of premises where Test / Examination was held: JCI BASE TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIC FIELD INDICATOR: BURMAH CASTROL STRIP

We hereby certify that on 08/09/11 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector:
Revision No: 01

Name of Inspector: OLATUNJI AKINLADE


Doc No: JCIC-020

Cert No.227173