JC International Limited: Certificate of Visual Examination and Mpi
JC International Limited: Certificate of Visual Examination and Mpi
Description of Equipment:
NL 92844
MANUFACTURER- CGS
Next Date of Examination: 07/03/12 METHOD: All accessible areas were subjected to a magnetic particle testing. No crack
or crack-like indication was found. NOTE: Lamination was found on both left and right ear, but still within
acceptance Criteria
SPECIFICATION : API RP 8B MPI METHOD: WET VISIBLE MATERIAL: CARBON STEEL. EQUIPMENT USED: PERMANENT MAGNET SERIAL NO. : 43254 COMSUMABLES USED: (a)CONTRAST PAINT (b)BLACK MAGNETIC INK RESULT: NO DEFECT FOUND (NDF) Name and address of equipment owner: SEADRILL Address of premises where Test / Examination was held: JCI BASE TEST PROCEDURE: JOP-020 MAGNETIZING CURRENT: DC MAGNETIC FIELD INDICATOR: BURMAH CASTROL STRIP
We hereby certify that on 08/09/11 (date) no defect was found on the item/s described on this certificate as at the time of inspection fit for use. Signature of Inspector:
Revision No: 01
Cert No.227173