“3438 5.03, 30605» gi,MAIN P.C. BOARD
(viewed from the component side)902A SERVICE MANUAL
ADJUSTMENT PROCEDURES
Adjustmant Notes: funtess otherwise spacitiga:!
t. Anisolation transformer must ha used when
servicing this unit,
2. Line voltage maintained at TZOVAC, 60Hz.
3. The unit should be allowed to warm up for
at least 30 minutes prior to making ary
adjustments.
4. Voltages measured with respect to ground.
3. Signal injection point is tha Video In Jack.
Power Supply Adjuatmant
1. With the unit off, set the Volume Contral
{R316}, Contrast Control (R585), and
Brightness Control {R589} to minimum.
Praset A114 to mechanical center.
Connect a voltmeter across C494 and turn on
the unit.
4. Adjust R114 for a reading of 125¥V on the
meter.
Ah
Horizonta! Synchronization Adjustmant
1. Inject 4 cross-hatch pattern signal and short
C434.
2. Adjust the horizontal syne with A437.
3. Remove tha short fram C434,
Vertical Synchronization Adjustment
1. Inject a cross-hatch pattern signal and short
C434,
2. Adjust the vartical sync with R331,
3. Remove the short from C434.
Horizontal Amplitude and Centering Adjustment
1. Inject a cross-hatch Pattern signal and set the
Brightness Controt (R589) and Contrast Con-
trol (R585) to their mechanical centers,
2. Adjust R485 so that 14 blocks correspond to
@ width of 28cm.
3. Adjust R453 te center the display
horizontatty,
Vertical Amplitude and Centering Adjustment
1. Inject a cross-hatech pattern signal and sat the
Brightness Contro! (R589) and Contrast Con-
tral (R585) to their mechanical centers.
2. Adjust R353 so that 10 blocks carrespond to
a height of 18.5em.
3. Adjust R364 to center the display verticaily,
Chrominanece Adjustment
1. Inject a color bar Pattern signal and adjust the
secondary controls for normal viewing. Place
SK3 inct used in CM8562} in the off position.
#, Connect an oscilloscope to pin 15 of C502
and adjust $533 for minimum amplitude of
the chrominance signal that is present on the
various brightness steps of the luminance
signal.
3. Short pins 9 and 17 of IC561.
4. Adjust C567 to minimize the chroma aS Visi-
ble on the screen,
9. Remove the shorting clips from pins 9 and 17.
Comb Fliter Adjustment
1. Inject a color bar pattern signal and place the
Comb Filter Switch (SK3) in the on position,
2. Connect an oscilloscope to the emitter of
T5531 and adjust R523 and $515 for
minimum amplitude of the chrominance
Signal. For optimum performance, repeat the
adjustment.
Focus Adjustmant
t. Inject a cross-hatch Pattern signal and set the
Brightness Control (R589) to minimum and
the Contrast Contral { R585) to maximum.
2. Adjust R732 for optimum focus,
X-Ray Protection Circuit Adjustment
1. Inject a color bar Pattern signal snd set the
Brightness and Contrast Controls te minimum.
2. Connect a voltmeter between the wiper af
R457 and ground.
3. Adjust R457 for a reading of 6.9V.
NOTE: The following adjustments need only be
Parformed if the CRT has been replaced. Minor
corrections far purity and convergence may be
accomplished through the use of the Purity and
Convergence Assambly located on tha neck of
the CRT.