CAPACITORS EMI and RFI FILTERS

COMPANY Ltd.

CAPACITORS
FOR MOTOR APPLICATIONS

MKP CAPACITORS FOR MOTOR APPLICATIONS CONTENTS


I. 1. MKP - GENERAL INFORMATION ................................................................. 1.1 General information ........................................................................................ 3 1.2 Application category ...................................................................................... 3 1.3 Typical dielectrics characteristics ................................................................ 4 1.4 Ordering code ................................................................................................. 5

2. APPLICATIONS .............................................................................................. 2.1 MKP capacitors for motor run applications ................................................. 6 - applicatoin advice .............................................................................................. 6 - technical data ...................................................................................................... 7

3. MKP CAPACITORS IN PLASTIC CASE ........................................................... 3.1 Design and available executions .................................................................. 8 3.2 Summary tables - series and dimensions ................................................... 9

4. MKP CAPACITORS IN ALUMINIUM CASE ..................................................... 4.1 Desigh and available executions .................................................................. . 1 0 4.2 Summary tables - series and dimensions ................................................... . 1 1

5. MKP CAPACITORS FOR MOTOR SRART APPLICATIONS ........................... 5.1 MKP-TLS capacitors with starting device for asynchronous motors ....... . 1 2 5.2 MKP-TLR capacitors with starting-regulative device for asynchronous motors ..................................................................................... ..13 5.3 Summary tables - series and dimensions...................................................... 14

II. 1 ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START 1.1 EAS MOTOR START CAPACITORS ..............................................................15 1.2 EAS-TLS capacitors with starting device for asynchronous motors ........19

W E
W E N
2

MKP CAPACITORS FOR MOTOR APPLICATIONS


GENERAL INFORMATION

ELECTRICAL SPECIFICATIONS AND DEFINITIONS - Dielectric: bi-axially oriented polypropylene - Plates: self-healing metal layer Zn or Al deposited by evaporation under vacuum Rated voltage UR The rms value of the sinusoidal AC voltage which can be applied to the capacitor in normal wrking conditions. From 250 to 500 V (see each series) Rated current IR The value of the current flowing through the capacitor of rated capacitance at the rated voltage and frequency. Duty frequency range The capacitors can be used at a frequency range of 5060 Hz. Use at higher frequencies is possible provided the voltage, current, temperature and power limits are complied with. Operating temperature class Minimum temperature - 25 0C. Maximum temperature +70 0C or +85 0C. In accordance with the reference standards, these temperatures are those measured on the surface of the capacitor. Storage temperature -10 0C ... +85 0C Capacitance tolerance Rated tolerance 5%; 10% Different tolerance values are available on request. Dissipation factor (tgd) The value of the tangent of the loss factor measured at 50 Hz, 20 0C at the rated voltage is:

Insulation resistance between terminals and case Measured at 500 VDC, 20 0C after 30 seconds. Ri > 1000 Mohm Direct current operation These capacitors can be used with a DC voltage not exceeding the peak value of the rated voltage VDC

42

Vn

MECHANICAL SPECIFICATIONS Mounting: The capacitors may be provided with stud M8 for mounting: The maximun torque is 5 Nm Vibrations: In accordance with IEC 68-2-6 standards, the capacitors pass the test with a frequency range from 10 to 55 Hz, acceleration amplitude 10 g and duration 6 h. Operating classes and climatic categories IEC/EN 60252 Operating classes of capacitors for single phase motors are identified as follows: a) Life expentancy

30.000 h class A
failure % max

10.000 h class B 3%

3.000 h class C 3%

1.000 h class D 3%

3%

b) Climatic category

25
min. permissible temperature

85
max. permissible temperature

21
damp heat days

tgd 20 x 10

-4

c) Class of safety protection P0 P1 P2 Without safety protection Safety achievable by external means (fuse) With internal safety protection

Maximum permissible overloads The capacitors can operate in the following overload conditions throughout the temperature class range: I max = 1.3 IR U max = 1.1 UR The overload deriving from the simultaneous presence of voltage and current above the rated values, even if within the stated limits, must be such that the apprent power Pa (Irms x Vrms) absorbed by the capacitor is: Pa 1.35 x 2p f x C x UR2 Pulsed stress The capacitors are capable of withstanding steep wavefronts with a maximum voltage variation speed of 20 V/m s.

Markings Black colour. Data shown: CONIS trade mark, Series number, Capacitance in microfarad, Tolerance in %, Rated A.C. Voltage, Operating temperature range in degrees Centigrade, Coded climatic class and reliability data according to DIN 40040, Self-Healing property SH, Year and mounth of production.

MKP CAPACITORS FOR MOTOR APPLICATIONS


CHARACTERISTIC CURVES

Capacitance vs. frequency

Capacitance vs. temperature at 1 kHz

tg d 10 -4

tg d 10 -4

Dissipation factor vs. frequency

Dissipation factor vs.temperature at 1kHz

MWx F

105 104 103 102 101 0 25 50 75 100

T [0C]

Time constant vs. temperature

MKP CAPACITORS FOR MOTOR APPLICATIONS ORDERING CODE

MKP

XX

Rated voltage VAC

CONIS internal code

Capacitance tolerance 5%; 10%

Code Al Pl Code A O 1 2 3 4 5

Type of case Aluminium Plastic Rated capacitance - F

Identifies the terminals Push-wire adaptor Unipolar leads Soldering tags 3.8x0.5 Double faston 6.3x0.8 Single faston 6.3x0.8 Twin-core cable Lateral lead wires

Code 1 2

Resistor without discharge resistor with discharge resistor

Code 1 2

Cap without cap with protective cap

Code 1 2

Resin without resin with resin

Code C D

Mounting without fixing stud with fixing stud

Example of the following code: MKP-Z-Al-1D-222 - 4 F 10% 250VAC describes a MKP-Z capacitor, aluminium case, soldering tags, fixing stud, discharge resistor, protective cap and resin, 4 m F 10% 250VAC

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS


APPLICATION ADVICE
Motor capacitors are operation capacitors for single-phase induction motors with auxiliary winding and three-phase motor in Steinmetz circuits. Motor capacitors are permanently connected to the windings of the motor, so that both motor and capacitor have the same mode of operation. Motor capacitors are self-healing capacitors, i.e. a weak point in the dielectric would become ineffective by itself since the metal coating evaporates at the weak point. Capacitors used in this way should be carefully selected as far as voltage rating is concerned, and special attention should be paid to the method of operation (continuous or intermittent). The voltage developed across the capacitor terminals is, usually, higher than the supply voltage. Motor capacitors are utilized mainly in the following fields: Household and domestic appliances Office machines Heating and ventilation techniques Garden and recreational equipment. Single-phase induction motors The single-phase motors has two windings. The main winding is supplied directly from the mains, whereas the auxiliary winding supply is provided by the capacitance of the series-connected capacitor /fig.1/. The capacitance is selected so that the auxiliary winding is able to take up the capacitor current continuously. No switching devices are necessary for the auxiliary winding circuit, so that in respect of operating reliability the singlephase capacitor start and run motor is in no way inferior to a three-phase cage rotor motor. The motor is superior to a single-phase motor in Steinmetz connection in so far as it can be adapted to a considerable degree to the drive requirements by an appropriate winding layout. Also the capacitanse of the capacitor used here is smaller in relation to an identical motor out-put. Single-phase capacitor start and run motors are suitable only for driving machines which do not require the full rated output of the motor for starting. The performance requirements for the capacitor depend on the output power or torque and the design of the motor. If the capacitor is to operate in conjunction with a 220V.50 Hz singlephase motor whose main and auxiliary windings have the same number of turns, then a capacitance of aproximately 30 to 50 m F per kW of the rated motor output power should be used.
Rotor Rotor Rotor

Operation of three-phase Motors in single-phase supply Induction motors with a three-phase stator winding can either be driven from a three-phase supply or from a single-phase supply when suitably connected with a capacitor (Steinmetz circuit, Fig. 2a and fig. 2b). A three-phase induction motor with its stator connected in star for a 380V three-phase supply has 220V as phase voltage. The motor can therefore also run on a 220V threephase supply when delta connected. If the motor is designed for 125/220V then its phase voltage is only 125V and the motor must be connected in star for a three-phase supply of 220V. The Steinmetz circuit gives similar characteristics to threephase operation but with a single-phase supply.The motor runs as a three-phase machine, if the capacitor voltage causes a symmetrical voltage star at the rotor windings as with a three-phase supply. A symmetrical voltage distribution can however only be obtained with a certain capacitor at a certain load. For all other loads an asymmetrical voltage star is formed at the rotor, so that the motor can no longer operate under optimum conditions. The starting torque is reduced and the heat generation in the motor can become higher at no load than at full load. Experience has shown that with a voltage supply of 220V, 50 Hz, a capacitance of 70 m F/kW of motor power is necessary in order to give a starting torque of 30% of rated torque and in operation about 80% of the rated three-phase power. In order to obtain a higher starting torque, a starting capacitor with about double the capacitance must be connected in parallel. This must be switched off during run up to avoid overloading the motor. The direction of rotation can be reversed by connecting the capacitor to the other supply connection. The voltage across the capacitor terminals in the Steinmetz circuits is, at the rated power of the motor, about the value of the supply voltage, and under no load about 15% higher. If the open star circuit should be used for a special application please state this when ordering in order that the correct capacitor can be supplied. This circuit can be used when 125/220V three-phase motors are to operated from a 220V single-phase supply.

Fig. 1 Auxiliary winding motor with continuous operation capacitor a/ Delta connection Torque-Speed Characteristic a - single-phase motor, single winding b - single-phase motor, two windings with starting capacitor c - singl-phase motor, two windings with continuous operation capacitor Fig. 3 b/ Star connection Fig. 2 Three-phase motor on single-phase supply

Torque-Speed Characteristic a - Three-phase motor b - Single-phase motor in Steinmetz connection Fig. 4

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS


TECHNICAL DATA SERIES Reference standards Storage temperature Rated AC Voltage UR Rated DC Voltage 42UR Voltage rise/fall time (dv/dt) max Test voltage between terminals Test voltage terminals to case Terminals Creepage distances Clearance in air m Self discharge time Ri(MW) x C(mF) W d Dissipation factor (tgd ) Vibration strength Max fixing torque Degree of protection (ref. EN 60529) Capacitance tolerance Maximum permissible voltage (RMS) Maximum permissible current (RMS) Maximum permissible reactive output Rated frequency Expected life Temperature range and climatic category Safety class 7 30 000 h cl.A

MKP-AL

MKP-PL

IEC252 EN60252 VDE 0560-8 - 10 +85 0C 250VAC 350VDC 15V/ m s 400 VAC 560VDC 20V/ m s 2 UR for 2 sec (2UR + 1000V) but at least 2 kV for 2 sec Faston 6.35x0.8 single or double; soldering tags 3.8x0.5; Twin cable 7 mm

450VAC 630VDC 20V/ m s

5 mm

R x C

3000 sec.

20 x 10-4 at U=UR 20 0C and 50 Hz

According to Test Fc of IEC 68-2-6 Test duration - 6h. Frequency range 10 to 55 Hz Amplitude -0.75 mm; Acceleration max - 10 g M8 bolt: 5 Nm IP00 with faston; IP55 with protective cap 5% or 10% ( different tolerance available upon request) 1.1 x UR 1.3 x IR 1.35 x QR 50 Hz (60 Hz on request) 10 000 h 3 000 h cl.B cl.C Failure rate max 3% 1 000 h cl.D

-25 0C +85 0C 25/85/21 P0; P2 (FPU) for MKP-AL on request

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS IN PLASTIC CASE


DESIGN
DIELECTRIC: Low losses polypropylene film metallized with Zn or Al SELFHEALING. WINDING: Non-inductive type CASE: Plastic materials self-extinguishing grade V2 according to UL 94 standard. RESIN: Non polluting filling compound made of vegetable oil (non PCB) improving the protection of the winding and the functioning of the capacitor. DECK: Plastic materials self-extinguishing, grade V1 or V0 according to UL 94 standard. TERMINALS: - Faston-tinned brass 6.35 x 0.8 single or double only for D 30 mm - Unipolar leads: stiff wires or flexible wires copper - 0.5 mm2; 0.75 mm2 length - min 80 mm, max 250 mm stripping - 5 mm 1 mm - Twin - core cables: sleeve - PVC 105 0C (90 0C) copper - 2 x 0.75 mm2 length - 120; 155; 195 mm (other lengths on request) unsheath - 75 2 mm stripping - 5 0.5 mm - tinned CLASS OF SAFETY PROTECTION: P0 REFERENCE STANDARDS: EN60252 APPLICATION Motor run and start

AVAILABLE EXECUTIONS

H2

L5

100.5

MKP-PL-4C twin-core cable MKP-PL-4D twin-core cable

M8

M8

MKP-PL-3D single faston

MKP-PL-2D double faston

100.5

100,5

MKP-PL-3C single faston

MKP-PL-2C double faston

H2

L5

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS IN PLASTIC CASE


SERIES Life 30 000 h HPF cl.A 10 000 h HPF cl. B 3 000 h HPF cl. C 1000 h HPF cl. D D m C /mF/ mm MKPZ-PL
250 VAC 400 VAC 450 VAC 500VAC

MKP-PL 400 VAC 450 VAC 500 VAC

400 VAC 450 VAC

D mm 25 25 25 30 30 30 30 30 35 35 35 35 35 40 40 40 45 45 45 45 40 40 40 45 40 45 H D

H mm 55 55 55 55 55 55 55 55 55 55 73 73 73 73 73 73 73 73 73 73 93 93 93 93 128 128

1.5 25 55 2.0 25 55 2.5 25 55 3.0 25 55 25 55 3.5 25 55 25 55 3.75 25 55 30 55 4.0 25 55 25 55 4.5 30 55 30 55 5.0 30 55 30 55 6.0 30 55 35 55 7.0 35 55 35 55 8.0 35 55 35 55 9.0 35 55 35 55 10.0 35 55 35 73 11.0 35 73 35 73 12.0 35 73 35 73 13.0 35 73 40 73 14.0 35 73 40 73 15.0 35 73 40 73 16.0 40 73 40 73 18.0 40 73 40 73 20.0 40 73 45 73 22.0 45 73 45 73 25.0 45 73 45 93 30.0 45 73 45 93 35.0 45 93 45 93 40.0 45 93 40 128 45.0 40 128 40 128 50.0 45 128 45 128 55.0 45 128 60.0 45 128 Other dimensions and capacitance values on request 9

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS IN ALUMINIUM CASE


DESIGN
DIELECTRIC: Low losses polypropylene film metallized with Zn or Al SELFHEALING. WINDING: Non-inductive type CASE: Aluminium with/without fixing stud M8 x 10 Locking strength - 5 Nm RESIN: Non polluting filling compound made of vegetable oil (non PCB) improving the protection of the winding and the functioning of the capacitor. DECK: Plastic materials self-extinguishing, grade V1 or V0 according to UL 94 standard. TERMINALS: - Faston-tinned brass 6.35 x 0.8 single or double only for D30 mm - Soldering tags - tinned steel 3.8 x 0.5 - Unipolar leads: stiff wires or flexible wires copper - 0.5 mm2; 0.75 mm2 length - min 80 mm, max 250 mm stripping - 5 mm 1 mm - Twin - core cables: sleeve - PVC 105 0C (90 0C) copper - 2 x 0.75 mm2 length - 120; 155; 195 mm (other lengths on request) unsheath - 75 2 mm stripping - 5 0.5 mm - tinned PROTECTIVE CAP: Plastic materials self-extinguishing, grade V2 according to UL 94 standard. CLASS OF SAFETY PROTECTION: P0 or P2 (FPU) for D=45 mm on request. ACCESSORIES: Protective cap Crimp M8 and hexagonal nut M8 REFERENCE STANDARD: EN60252 - for motor run capacitors APPLICATION Motor run and start
L5

AVAILABLE EXECUTIONS

3.8x0.5

H2

H2

MKP-AL-4C twin-core cable MKP-AL-2C MKP-AL-3C double faston single faston MKP-AL-1C soldering tags
L5
3.8x0.5

H2

100.5

100.5

H2

M8

M8

100.5

M8

M8

MKP-AL-4D twin-core cable MKP-AL-1D soldering tags

MKP-AL-2D double faston

MKP-AL-3D single faston

10

100.5

MKP CAPACITORS FOR MOTOR RUN APPLICATIONS IN ALUMINIUM CASE


SERIES Life 30 000 h HPF cl. A 10 000 h HPF cl. B HSF 3 000 h HPF cl. C HSF 1000 h HPF cl. D C /mF/ D mm MKPZ-AL
250 VAC 400 VAC 450VAC 500VAC 25m F m 500VAC>25m F m 450 VAC 500 VAC

MKP-AL 400 VAC 450 VAC 500 VAC

400 VAC 450 VAC

D mm 60 60 60 78 78 78 60 60 78 78 78 78 78 78 78 78 98 98 98 98 98 132 132 132 132 132 132 132 leads. H D

D mm

H mm 60 60 60 78 78 78 60 60 78 78 78 78 78 78 78 78 98 98 98 98 98 132 132 132 132 132 132 132

2.0 25 60 25 60 25 3,0 25 60 25 60 30 3,5 25 60 25 60 30 3,75 25 60 25 60 25 4.0 25 60 30 60 25 4.5 25 60 30 60 25 5.0 30 60 30 60 35 6.0 30 60 35 60 35 7.0 35 60 35 60 35 8.0 35 60 35 60 35 9.0 35 60 35 78 35 10.0 35 60 35 78 40 11.0 35 78 35 78 40 12.0 35 78 35 78 40 14.0 35 78 40 78 45 15.0 35 78 40 78 45 16.0 35 78 40 78 40 18.0 40 78 40 78 40 20.0 40 78 40 98 45 22.0 45 78 40 98 45 25.0 45 78 40 98 45 30.0 45 78 45 98 45 32.0 45 78 45 98 45 35.0 45 98 45 98 50 40.0 45 98 40 132 50 45.0 40 132 45 132 50 50.0 45 132 50 132 55 55.0 45 132 55 132 55 60.0 45 132 55 132 *D 50 mm only for design with twin core cable or unipolar Other capacitance values and other dimensions on request 11

25 30 30 25 25 25 35 35 35 35 35 40 40 40 45 45 40 40 45 45 45 45 45 50 50 50 55 55

MKP CAPACITORS FOR MOTOR START APPLICATIONS MKP-TLS CAPACITOR WITH STARTING DEVICE FOR ASYNCHRONOUS MOTORS
APPLICATION
MKP-TLS capacitors are used for starting of single-phase asynchronous motors or three-phase motors in a single-phase net. MKP-TLS consists of two elements - MKP selfhealing capacitor with metallized polypropylene for dielectric and an electronic device TLS. The electronic device turns off the starting capacitor after attainment of 75 up to 100% of the nominal revolutions of the motor but not later than Tmax. The constructive features of the motors (quality of steel, scheme of coils winding, number of motor poles and supply voltage frequency) dont influence on the operation of MKP-TLS. A centrifugal breaker is not necessary when a capacitor with a starting device is used. Advantages of MKP-TLS: - Simplification of the motor construction and reduction of its overall dimensions. - Possibility of operating of the motor at heavier conditions - high humidity, availability of vibrations etc. - Reliability increase - Motor cost price decrease

TECHNICAL CHARACTERISTICS
Nominal voltage Nominal capacitance of start-up capacitor Nominal voltage of start-up capacitor Nominal frequency Working temperature range Nominal current Maximum starting regime Tmax Recovery time for the second time switching on Overall dimensions Terminals - length - bared outside insulation - stripped and tinned wire 110; 220 VAC 10 up to 120 mF 250; 450 VAC 42 up to 60 Hz -25C + 85C 6A; 16A; 25A; 40A 3 sec; 5 sec (other times are available at request) 1 - 2 sec see table 1 three-core cable 3x0,75mm2 , PVC 105C 120; 150; 250 mm (other lengths are available at request) 35 5 mm 5 0,5 mm

12

MKP CAPACITORS FOR MOTOR START APPLICATIONS MKP-TLR CAPACITOR WITH A STARTING - REGULATIVE DEVICE FOR ASYNCHRONOUS MOTORS
APPLICATION
MKP-TLR capacitors are used for starting of single-phase asynchronous motors or three-phase motors in a single-phase net. MKP-TLR consists of two elements - MKP selfhealing capacitor with metallized polypropylene for dielectric and an electronic device TLR. The electronic device is with a regulator which turns off the starting capacitor after attainment of 75 up to 100% of the nominal revolutions of the motor but not later than Tmax. If a reduction of the speed < 75% happens, due to shaft load, the capacitor automatically switches on itself so to recover the motor regime. The constructive features of the motors (quality of steel, scheme of coils winding, number of motor poles and supply voltage frequency) dont influence on the operation of MKP-TLR. A centrifugal breaker is not necessary when a capacitor with a starting device and a regulator is used. Advantages of MKP-TLR: - Simplification of the motor construction and reduction of its overall dimensions. - Possibility of operating of the motor at unstable supply voltage and heavier conditions- high humidity, availability of vibrations etc. - Reliability increase - Motor cost price decrease MKP-TLR are suitable for use at motors with irregular load or power supply networks with high variations of the nominal voltage. TECHNICAL CHARACTERISTICS Nominal voltage Nominal capacitance of start-up capacitor Nominal voltage of start-up capacitor Nominal frequency Working temperature range Nominal current Maximum starting regime Tmax Recovery time for the second time switching on Overall dimensions Terminals - length bared outside insulation stripped and tinned wire 110; 220 VAC 10 up to 120 m F 250; 450 VAC 42 up to 60 Hz -25C + 85C 6A; 16A; 25A; 40A 3 sec; 5 sec (other times are available at request) 1 - 2 sec see table 1 three-core cable 3x0,75mm 2, PVC 105C 120; 150; 250 mm (other lengths are available at request) 35 5 mm 5 0,5 mm

13

MKP CAPACITORS FOR MOTOR START APPLICATIONS


Table 1 Capacitance Case Capacitance Case MKP-TLS-PL-4C MKP-TLR-PL-4C MKP-TLS-PL-4D MKP-TLR-PL-4D

mF 10 20 30 35 40 45 50

DxH 45 x73 45 x 73 45 x 73 45 x 93 45 x 93 45 x 128 45 x 128

mF m 60 70 80 85 90 100 120

DxH 45 x128 50 x 94 50 x 119 50 x 119 55 x 119 55 x 119 60 x 119

L5

H2

H2
8

L5

14

100,5

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START

EAS-A SERIES EAS-B SERIES EAS-C SERIES

EAS SERIES AC MOTOR - START CAPACITORS


*For single-phase motor starting ( air conditioners, water pumps, refrigerators and similar applications)

SPECIFICATION

ITEM Operating temperature range Rated working voltage range Ur Capacitance range Dissipation factor at 200C 50 to 60 Hz

EAS-A

EAS-B

EAS-C

- 15 to +60 0C

- 15 to +60 0C

- 15 to +60 0C

125 to 320 VAC

125 to 320 VAC

125 to 320 VAC

30 to 500 m F

30 to 500 m F

30 to 500 m F

0.16

0.14

0.12

Duty cycle

AB 0.55% ED AB 1.7% ED AB 1% ED (Twenty applications (Twenty applications (Twenty applications per hour with per hour with per hour with duration 1 sec.) duration 3 sec.) duration 2 sec.)

15

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START

EAS-1
CASE: Without end cap Without fixing stud

DIMENTIONS [mm]

L1 Lmax

TABLE D x L F
60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250

VAC

EAS - A1 D L1 Lmax
38 38 38 38 38 46 46 46 46 38 38 38 46 46 46 46 46 46 38 38 38 38 46 46 46 46 46 38 38 38 46 46 46 46 46 46 38 38 46 46 46 46 46 46 52 70 70 70 70 70 85 85 85 85 70 70 70 85 85 85 85 85 85 70 70 70 70 85 85 85 85 85 70 70 70 85 85 85 85 85 85 70 70 85 85 85 85 85 85 105 82 82 82 82 82 98 98 98 98 82 82 82 98 98 98 98 98 98 82 82 82 82 98 98 98 98 98 82 82 82 98 98 98 98 98 98 82 82 98 98 98 98 98 98 123

EAS - B1 D L1 Lmax
38 38 38 38 38 46 46 46 46 38 38 38 46 46 46 46 46 52 38 38 38 38 46 46 46 46 46 38 38 46 46 46 46 46 46 52 38 38 46 46 46 46 46 46 52 70 70 70 70 70 85 85 85 85 70 70 70 85 85 85 85 85 105 70 70 70 70 85 85 85 85 85 70 70 85 85 85 85 85 85 105 70 70 85 85 85 85 85 85 105 82 82 82 82 82 98 98 98 98 82 82 82 98 98 98 98 98 123 82 82 82 82 98 98 98 98 98 82 82 98 98 98 98 98 98 123 82 82 98 98 98 98 98 98 123

EAS - C1 D L1 Lmax
38 38 38 38 38 46 46 46 46 38 38 46 46 46 46 46 46 52 38 38 46 46 46 46 46 46 52 38 38 46 46 46 46 46 46 52 38 38 46 46 46 46 46 52 70 70 70 70 70 85 85 85 85 70 70 85 85 85 85 85 85 105 70 70 85 85 85 85 85 85 105 70 70 85 85 85 85 85 85 105 70 70 85 85 85 85 85 105 82 82 82 82 82 98 98 98 98 82 82 98 98 98 98 98 98 123 82 82 98 98 98 98 98 98 123 82 82 98 98 98 98 98 98 123 82 82 98 98 98 98 98 123

125

160

220

280

320

Note: Capacitors are available with other sizes by customer's request

16

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START

EAS-2
L max

DIMENTIONS [mm]

CASE: With end cap Without fixing stud

+1.0 D-0.5

5.35.6

180+10

TABLE D x L EAS - C2
38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 38x87 38x87 38x98 38x98 38x98 43x98 43x98 43x98 43x128 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 43x128 43x128 43x128 43x128 38x87 38x87 38x87 38x87 38x98 43x98 43x98 43x98 43x128 43x128 43x128 43x128 38x87 38x87 38x87 38x87 38x98 43x98 43x98 43x128 43x128

F
60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250

VAC

EAS - A2
38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 38x87 38x87 38x87 38x87 38x87 38x87 38x87 43x98 43x98 43x98 43x128 43x128 38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 43x98 43x128 43x128 38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98

EAS - B2
38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 38x87 38x87 38x87 38x87 38x98 43x98 43x98 43x98 43x98 38x87 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 43x98 43x128 43x128 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 43x98 43x98 43x128 43x128 38x87 38x87 38x87 38x87 38x98 38x98 43x98 43x98 43x128

125

160

220

280

320

Note: Capacitors are available with other sizes by customer's request

17

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START

EAS-3
With fixing stud M8 x 10
L max

DIMENTIONS [mm]

CASE: With end cap

D max

180+10

5.35.6

M8

TABLE D x L EAS - C3
38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 38x90 38x90 38x100 38x100 38x100 43x100 43x100 43x100 43x130 38x90 38x90 38x90 38x90 38x100 38x100 38x100 43x100 43x130 43x130 43x130 43x130 38x90 38x90 38x90 38x90 38x100 43x100 43x100 43x100 43x130 43x130 43x130 43x130 38x90 38x90 38x90 38x90 38x100 43x100 43x100 43x130 43x130

F
60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250

VAC

EAS - A3
38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 38x90 38x90 38x90 38x90 38x90 38x90 38x90 43x100 43x100 43x100 43x130 43x130 38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 43x100 43x130 43x130 38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100

EAS - B3
38x90 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 38x90 38x90 38x90 38x90 38x90 43x100 43x100 43x100 43x100 38x90 38x90 38x90 38x90 38x90 38x90 38x90 43x100 43x100 43x100 43x130 43x130 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 43x100 43x100 43x130 43x130 38x90 38x90 38x90 38x90 38x100 38x100 43x100 43x100 43x100

125

160

220

280

320

Note: Capacitors are available with other sizes by customer's request

18

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START EAS-TLS CAPACITOR WITH A STARTING DEVICE FOR ASYNCHRONOUS MOTORS
APPLICATION
EAS-TLS capacitors are used for starting of single-phase asynchronous motors or three-phase motors in a single-phase net. EAS-TLS consists of two elements - Electrolytic motor-start capacitor EAS and an electronic device TLS. The electronic device turns off the starting capacitor after attainment of the nominal revolutions but not later than Tmax. The constructive features of the motors (quality of steel, scheme of coils winding, number of motor poles and supply voltage frequency) dont influence on the operation of EAS-TLS. A centrifugal breaker is not necessary when a capacitor with a starting device is used. Advantages of EAS-TLS. - Simplification of the motor construction and reduction of its sizes - Possibility of operating at heavier conditions - unstable supply voltage, high humidity, availability of vibrations etc. - Prevent the motor from burning - Reliability increase - Motor cost price decrease TECHNICAL CHARACTERISTICS Nominal supply voltage Nominal capacitance of start-up capacitor Nominal voltage of start-up capacitor Nominal frequency Working temperature range Nominal current Maximum starting regime Tmax Recovery time for the second time switching on Dimensions Terminals - length bared outside insulation stripped and tinned wire 110; 220 VAC 30 up to 500 mF 125 up to 320 VAC 42 up to 60 Hz -15C + 60C 6A; 16A; 25A; 40A 3 sec; (other times are available at request) 3 min see table 1 and 2 three-core cable 3x0,75mm2, 105C, PVC 120; 150; 250 mm (other lengths are available at request) 35 5 mm 5 0,5 mm

19

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START


EAS-TLS CAPACITOR WITH A STARTING DEVICE FOR ASYNCHRONOUS MOTORS

EAS-TLS
CASE: With end cap Without fixing stud
L max

DIMENTIONS [mm]

+1.0 D-0.5

5.66.1

180+10

TABLE 1
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142

/D x L/

F
60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250

VAC

EAS-TLS - A2
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142

EAS-TLS - B2
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142

EAS-TLS - C2

125

160

220

280

320

Note: Capacitors are available with other sizes by customer's request

20

ALUMINIUM ELECTROLYTIC CAPACITORS - AC MOTOR START


EAS-TLS CAPACITOR WITH STARTING DEVICE FOR ASYNCHRONOUS MOTORS

EAS-TLS
CASE: With end cap With fixing stud M8 x 10
L max

DIMENTIONS [mm]

D max

180+10

5.66.1

M8

TABLE 2 F
60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250 250 - 315 315 - 400 400 - 500 30 - 40 40 - 50 50 - 60 60 - 80 80 - 100 100 - 120 120 - 150 150 - 200 200 - 250

/D x L/

VAC

EAS-TLS - A3
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142

EAS-TLS - B3
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142

EAS-TLS - C3
45x107 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142 45x142 45x142 45x107 45x107 45x107 45x107 45x107 45x142 45x142 45x142 45x142

125

160

220

280

320

Note: Capacitors are available with other sizes by customer's request