Check Ec120
Check Ec120
Check Ec120
ENGINE STARTING
1. 2. 3. 4. 5. 6. 7. 8. 9. Booster pump A/C & PSTN light T4 TWG Starter TWG Ng = 50% TWG ON (30 seconds) FUEL P goes out ON < 150o (if not : check AFM) start position (white mark) depress (temp rises) monitor T4 (700o) release starter FLIGHT position maintain Tq < 40%
Check that ENG P HYDR MGB P lights go out HORN ON, check aural warning check HORN goes out FLIGHT position, TWG goes out
RUN UP CHECK
1. 2. 3. 4. 5. Pitot heat Booster pump All necessary systems Hydraulic accumulator Hydraulic shutt-off test ON, PITOT goes out OFF ON, tested CHECK CHECK
Wait 1 minute 63% < NG < 68% 5. 6. 7. 8. 9. GENE All systems, except BATT TWG Rotor brake A/C light OFF OFF shut-off position apply 150 RPM max. OFF
VEMD check : NG and NF cycles 10. Check 11. BATT 121.5 (emergency freq.) OFF