Ultrasonic Transducer For Humidifier

Lattrons transducers for ultra sonic humidifier are designed for special users who need high corrosion resistance. It has unique electrod of ceramic (TiN) thin film.

Features
TiN ELECTRODE ( UNIQUE IN THE WORLD) LONG LIFETIME HIGH Tc GOOD RESISTANCE TO SCALE

Application
FOR ULTRASONIC HUMIDIFIER FOR MEDICAL NEBULIZER FOR SHOW CASE FOR INDUSTRIAL HUMIDIFIER

Application Spec.
SPECIFICATION
RESONANCE FREQUENCY DRIVING VOLTAGE DIMENSION THICKNESS ELECTRODE DIMENSION. LPC-HT-16 1650 KHz 70 250 Vp-p D 20 mm X 1.25 mm 1.25 mm D 10 mm LPC-HT-16 2400 KHz 70 150 Vp-p D 20 mm X 0.85 mm 0.85 mm D 10 mm 0.1 mm 0.05 mm TOLERANCE 3%

UNIT : mm

www.lattron.com

SPECIFICATIONS
Specifications Unit Values Condition of measurement : 26 1 Operating temp : 26 1 The water level : 45mm (Above surface of transducer) Measuring duration : 1 hour (After 5 minutes operating with 110% operating input. Mist output is converted from the weight decrease of water for 1 hour) Used a standard circuit 25W operating Standard : 50% diminution of mist output Measured by HP4194A Measured by HP4194A KEITHLEY Model 2000 Operating water temp

1) Mist output ratio (Tentative)

cc/hrs

450

2) Life time (Tentative)

hrs

10000

3) Capacitance 4) Dielectric loss 5) Resistivity 6) Resonant frequency 7) Resonant impedance

pF % M MHz

1600

20%

0.5% 1 1.65 103 0.1 1.0

Measured by HP4194A Measured by HP4194A Kr = 100 {2.51(Frr Faa)/Frr} Frr: Resonant frequency in radial mode Faa: Ant-resonant frequency in radial mode

8) Radial coupling factor

48%

OPERATION CONDITION
Classification Operating water Operating humidity Max input Max temperature Condition of examination Service water, Drinking water 85% RH 35 W 85

www.lattron.com