Hermetic Compressors
Hermetic Compressors
Hermetic Compressors
BOX 91
89219-901 - Joinville - SC - Brazil
Phone: +55 47 3441-2121
Fax: +55 47 3441-2780
^
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 1 - 98
This handbook on hermetic compressors is designed for those working in the refrigeration field,
whom already know the basic techniques of domestic and commercial refrigeration, and air con-
ditioning. It is intended to be a guide in the selection of Embraco Europe compressors and their
correct application.
GENERAL INDEX
1 TECHNICAL DOCUMENTS 11
1.1 GENERAL CATALOG 11
1.2 GENERAL GUIDE OF COMPRESSORS 11
1.3 TECHNICAL BULLETIN 11
1.4 ELECTRICAL COMPONENT CATALOG 12
1.5 COMPRESSOR HANDBOOK 12
1.6 ELECTRONIC CATALOG 12
2 GENERAL INFORMATION 13
2.1 COMPRESSOR RANGES 13
Table 1 Compressor Series - Application - Refrigerants .................................................................................13
2.2 APPLICATIONS 13
Table 2 Applications...............................................................................................................................................13
2.3 STARTING TORQUE CLASSIFICATION 14
Table 3 Electrical motor starting torque classification....................................................................................14
2.4 ELECTRIC MOTOR TYPES 14
Table 4 Electrical motor types..............................................................................................................................14
2.5 VOLTAGES & FREQUENCIES 15
Table 5 Voltages & Frequencies ..........................................................................................................................15
2.6 COMPRESSOR ELECTRICAL COMPONENTS 16
Table 6 Electrical components..............................................................................................................................16
2.7 COMPRESSOR COOLING TYPES 16
Table 7 Cooling Types............................................................................................................................................16
2.8 COMPRESSOR NAMEPLATES - IDENTIFICATION DATA 17
Figure 1 Metallic Nameplates (used up to 2001) ...............................................................................................17
Figure 2 Adhesive Nameplates ..............................................................................................................................17
Figure 3 Series NB/NE - Adhesive Nameplates (used up to 2003) .................................................................18
Figure 4 Series BP - Adhesive Nameplates (used up to 2004) .........................................................................18
Figure 5 Series EM - Adhesive Nameplates ........................................................................................................18
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
2 - 98
Figure 6a Compressor Model Identification Code .............................................................................................. 19
Figure 6b Series EM - Compressor Model Identification Code ........................................................................ 20
Figure 7 Compressor Bill of Materials Code ..................................................................................................... 21
Figure 8 Manufacturing Date Code ..................................................................................................................... 21
2.9 WIRING DIAGRAMS 22
Table 8 Wiring Diagram....................................................................................................................................... 23
2.9.1 Compressor Wiring Diagram - EM Series - RSIR ............................................................................ 24
Figure 9 RSIR Version terminal board with PTC starting device .................................................................. 24
2.9.2 Compressor Wiring Diagram BP-NB Series RSIR-RSCR .......................................................... 24
Figure 10 RSIR and RSCR Standard Version ....................................................................................................... 24
2.9.3 Compressor Wiring Diagram BP-T-NB-NE Series (electrical components without
terminal board) RSIR-CSIR .............................................................................................................. 25
Figure 11 RSIR and CSIR standard version ......................................................................................................... 25
2.9.4 Compressor Wiring Diagram T Series (electrical component with
terminal board) RSIR-CSIR .............................................................................................................. 25
Figure 12 RSIR - CSIR terminal board version ................................................................................................... 25
2.9.5 Compressor Wiring Diagram NB-NE Series (electrical component with
terminal board) RSIR-CSIR .............................................................................................................. 26
Figure 13 RSIR and CSIR terminal board version .............................................................................................. 26
2.9.6 Compressor Wiring Diagram NB Series (electrical component with
terminal board) RSIR-RSCR ............................................................................................................. 26
Figure 14 RSIR and RSCR terminal board version with PTC starting device ............................................... 26
2.9.7 Compressor Wiring Diagram T-J Series PSC-CSR ...................................................................... 27
Figure 15 PSC and CSR Versions .......................................................................................................................... 27
2.9.8 Compressor Wiring Diagram NE-T-J Series CSR BOX .............................................................. 27
Figure 16 CSR BOX with internal or external overload protector ................................................................... 27
2.9.9 Compressor Wiring Diagram T-J Series CSIR .............................................................................. 28
Figure 17 Standard CSIR (with the relay T.I. 3CR or G.E. 3ARR2) ................................................................ 28
2.9.10 Compressor Wiring Diagram T-J Series CSIR BOX .................................................................... 28
Figure 18 CSIR BOX (with relay T.I. 3CR or G.E. 3ARR2) .............................................................................. 28
2.9.11 Compressor Wiring Diagram J Series CSIR BOX ........................................................................ 29
Figure 19 CSIR BOX (with relay G.E. 3ARR3 or AMF RVA) ........................................................................... 29
2.9.12 THREE PHASE ...................................................................................................................................... 29
Figure 20 Three Phase ............................................................................................................................................. 29
3 COMPRESSOR SUPPLY CONDITIONS 30
3.1 ELECTRICAL INSULATION 30
3.2 IP DEGREE OF PROTECTION 30
Table 9 IP Degree .................................................................................................................................................. 30
3.3 THE COMPRESSOR SHELL HYDROSTATIC STRENGTH 30
3.4 DEHYDRATION 31
Table 10 Maximum level of residual humidity .................................................................................................... 31
3.5 PAINTING 31
MP01EH 2000-04 07 2010-02
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
3 - 98
3.6 COMPRESSOR PRESSURISATION 31
3.7 OIL CHARGE 31
Table 11 Lubricant oils used in the compressors ................................................................................................32
3.8 MINIMUM QUANTITY OF LUBRICANT 32
Table 12 Minimum quantity of oil ..........................................................................................................................32
3.9 SPECIAL VERSIONS 33
Table 13 Special Version Examples.......................................................................................................................33
4 COMPRESSOR PACKAGING 34
4.1 MULTIPLE CARTON DISPOSABLE PACKAGE 34
Table 14 Characteristics of carton multiple packages .......................................................................................34
Figure 21 One Box + Shipping Skid .......................................................................................................................34
Figure 22 Two Boxes + Shipping Skid ...................................................................................................................34
4.1.1 Compressor Identification Marks .........................................................................................................35
Figure 23 Package Label ..........................................................................................................................................35
4.2 RETURNABLE WOOD PACKAGE 36
Table 15 Characteristics of returnable multiple wood packages .....................................................................36
Figure 25 EM (120 compressors) ........................................................................................................................36
Figure 26 EM (100 compressors) ........................................................................................................................37
Figure 27 NB (80 compressors) ..........................................................................................................................37
4.2.1 Compressor identification marks ..........................................................................................................37
4.3 PACKAGE FOR ELECTRICAL COMPONENTS AND ACCESSORIES 38
Figure 28 Components packing label .....................................................................................................................38
4.4 SINGLE PACKAGE 39
Figure 29 Single Compressor Package ..................................................................................................................39
5 HANDLING, TRANSPORTING AND STORING
COMPRESSORS 40
5.1 HANDLING 40
5.2 TRANSPORTING 40
5.2.1 Shipment by container ............................................................................................................................40
Table 16 Load Characteristics for 20' container.................................................................................................41
5.2.2 Shipments by truck ..................................................................................................................................41
Table 17 Characteristics of load by truck.............................................................................................................41
5.3 ACCEPTABLE COMPRESSOR POSITIONS DURING TRANSPORTATION 42
Table 18 Acceptable compressor position during transportation.....................................................................42
5.4 STORAGE 43
Table 19 Maximum height for multiple throwaway carton packages ..............................................................43
Table 20 Maximum height for multiple returnable packages............................................................................44
MP01EH 2000-04 07 2010-02
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 4 - 98
6 INFORMATION ABOUT CORRECT COMPRESSOR
INSTALLATION 45
6.1 COMPRESSOR SELECTION 45
6.1.1 Minimum evaporating temperature ..................................................................................................... 45
6.1.2 ReIrigeration capacity ............................................................................................................................ 45
6.1.3 ReIrigerant type ....................................................................................................................................... 45
6.1.4 Ambient temperature .............................................................................................................................. 45
6.1.5 Operating Voltages and Frequencies ................................................................................................... 46
6.1.6 Electric motor starting torque ............................................................................................................... 46
6.1.7 Compressor cooling type ....................................................................................................................... 46
6.1.8 Noise level ............................................................................................................................................... 46
6.1.9 Maximum current input ......................................................................................................................... 46
6.2 COMPRESSOR UNPACKING 46
6.3 PREPARATION OF REFRIGERATING SYSTEM COMPONENTS 47
6.4 REFRIGERANT USE GUIDE 48
6.4.1 Guide Ior the use oI R134a ................................................................................................................... 49
Table 21 R134a Physical Characteristics ............................................................................................................ 49
Table 22 R134a Ecological Characteristics ........................................................................................................ 49
6.4.2 Guide Ior the use oI R600a ................................................................................................................... 52
Table 23 R600a Physical characteristics ............................................................................................................. 52
Table 24 R 600a Ecological Characteristics....................................................................................................... 52
6.4.3 Guide Ior the use oI R404A .................................................................................................................. 54
Table 25 R 404A Physical Characteristics .......................................................................................................... 54
Table 26 R 404A Ecological Characteristics....................................................................................................... 54
6.4.4 Guide Ior the use oI R407C .................................................................................................................. 57
Table 27 R 407C Physical Characteristics .......................................................................................................... 57
Table 28 R 407C Ecological Characteristics ...................................................................................................... 57
6.4.5 Guide Ior the use oI R290 ..................................................................................................................... 60
Table 29 R290 Physical Characteristics .............................................................................................................. 60
Table 30 R290 Ecological Characteristics .......................................................................................................... 60
6.5 FILTER DRYER 62
Table 31 Suggested Filter Dryer............................................................................................................................ 62
Table 32 Inconvenient caused by moisture in the system.................................................................................. 62
6.6 CAPILLARY TUBES 63
Table 33 Choice of Capillary ................................................................................................................................. 63
6.7 APPLICATION OF RUBBER GROMMETS 70
Figure 30 Rubber Grommets Assembling Process .............................................................................................. 70
Table 34 Rubber Grommets.................................................................................................................................... 71
Figure 31 Rubber Grommets ................................................................................................................................... 71
6.8 WELDING OF CONNECTION TUBES 73
6.9 ROTALOCK VALVES 73
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 5 - 98
Table 35 Suggested tightening torques..................................................................................................................74
Figure 32 Rotalock Valve .........................................................................................................................................74
Figure 33 Valve Position ..........................................................................................................................................75
6.10 COMPRESSOR COOLING 75
Table 36 Fan Coolers Characteristics...................................................................................................................75
6.11 VACUUM OPERATIONS 76
6.12 REFRIGERANT CHARGE 76
Table 37 Maximum Refrigerant Charge................................................................................................................76
6.13 REFRIGERANT LEAKS CONTROL 77
6.14 ELECTRIC SUPPLY 77
7 RUNNING DATA AND COMPRESSOR CHECKING
PROCEDURES 78
7.1 COMPRESSOR RUNNING LIMITS 78
7.1.1 Maximum temperature oI electric motor stator windings ................................................................78
7.1.2 Discharge gas maximum temperature ..................................................................................................79
7.1.3 Discharge gas maximum pressures ......................................................................................................79
Table 38 Discharge gas maximum pressures .......................................................................................................79
7.1.4 Suction gas overheating ..........................................................................................................................79
7.1.5 Compressor operating Iields ..................................................................................................................80
7.1.6 Start conditions ........................................................................................................................................82
Table 39 Pressure limit value..................................................................................................................................82
7.1.7 Oil cooler temperatures ..........................................................................................................................82
7.1.8 Running time ............................................................................................................................................83
7.1.9 Cycling ......................................................................................................................................................83
7.2 COMPRESSOR CONTROL PROCEDURES 83
7.3 TROUBLESHOOTING AND SERVICE CHART 83
Table 40 Troubleshooting and service chart ........................................................................................................84
7.4 ELECTRIC CIRCUITS CONTROL 87
7.4.1 Standard version RSIR - RSCR EM Series with PTC starting device ...........................................87
7.4.2 Standard version RSIR - RSCR BP Series with PTC starting device ............................................88
7.4.3 Standard version RSIR NB - NE - T Series with electromagnetic current relay ..........................88
7.4.4 Standard version CSIR NB - NE - T Series with electromagnetic current relay ..........................89
7.4.5 Terminal board version RSIR NB - NE - T Series with electromagnetic current relay ..............90
7.4.6 Terminal board version CSIR NB - NE - T Series with electromagnetic current relay ..............90
7.4.7 Terminal board version RSIR and RSCR NB Series with PTC starting device ...........................91
7.4.8 Standard version PSC NE - T - J Series ..............................................................................................92
7.4.9 Standard versions CSR - CSR BOX NE - T - J Series with potential current relay ....................92
7.4.10 Standard versions CSIR and CSIR BOX T and J Series with current electromagnetic relay ....93
7.4.11 Standard version CSIR J Series with current electromagnetic relay ..............................................94
7.4.12 Three-Phase Version J ............................................................................................................................94
COMPRESSORS
HANDBOOK
GENERAL INDEX
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 6 - 98
7.5 CONTROL PROCEDURES 95
7.5.1 Control oI electric motor stator windings ........................................................................................... 95
7.5.2 Control oI stator windings ohmic resistance ...................................................................................... 95
7.5.3 Control oI start and run capacitors ....................................................................................................... 95
8 HOW TO RETURN SUPPLIED PRODUCTS
TO EMBRACO EUROPE 96
8.1 CONDITIONS 96
8.2 TESTS ON THE CUSTOMER APPLICATIONS 97
COMPRESSORS
HANDBOOK
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 7 - 98
INDEX OF FIGURES
Figure 1 7 1 ) 1 0 0 2 o t p u d e s u ( s e t a l p e m a N c i l l a t e M
Figure 2 7 1 s e t a l p e m a N e v i s e h d A
Figure 3 8 1 ) 3 0 0 2 o t p u d e s u ( s e t a l p e m a N e v i s e h d A - E N / B N s e i r e S
Figure 4 8 1 ) 4 0 0 2 o t p u d e s u ( s e t a l p e m a N e v i s e h d A - P B s e i r e S
Figure 5 8 1 s e t a l p e m a N e v i s e h d A - M E s e i r e S
Figure 6a 9 1 e d o C n o i t a c i f i t n e d I l e d o M r o s s e r p m o C
Figure 6b 0 2 e d o C n o i t a c i f i t n e d I l e d o M r o s s e r p m o C - M E s e i r e S
Figure 7 1 2 e d o C s l a i r e t a M f o l l i B r o s s e r p m o C
Figure 8 1 2 e d o C e t a D g n i r u t c a f u n a M
Figure 9 4 2 e c i v e d g n i t r a t s C T P h t i w d r a o b l a n i m r e t n o i s r e V R I S R
Figure 10 4 2 n o i s r e V d r a d n a t S R C S R d n a R I S R
Figure 11 5 2 n o i s r e v d r a d n a t s R I S C d n a R I S R
Figure 12 5 2 n o i s r e v d r a o b l a n i m r e t R I S C - R I S R
Figure 13 6 2 n o i s r e v d r a o b l a n i m r e t R I S C d n a R I S R
Figure 14 6 2 e c i v e d g n i t r a t s C T P h t i w n o i s r e v d r a o b l a n i m r e t R C S R d n a R I S R
Figure 15 7 2 s n o i s r e V R S C d n a C S P
Figure 16 7 2 r o t c e t o r p d a o l r e v o l a n r e t x e r o l a n r e t n i h t i w X O B R S C
Figure 17 8 2 ) 2 R R A 3 . E . G r o R C 3 . I . T y a l e r e h t h t i w ( R I S C d r a d n a t S
Figure 18 8 2 ) 2 R R A 3 . E . G r o R C 3 . I . T y a l e r h t i w ( X O B R I S C
Figure 19 9 2 ) A V R F M A r o 3 R R A 3 . E . G y a l e r h t i w ( X O B R I S C
Figure 20 Three Phase 29
Figure 21 4 3 Carton Package Unit
Figure 22 4 3 Wood Package Unit
Figure 23 Package Label 35
Figure 25 EM (120 6 3 ) s r o s s e r p m o c
Figure 26 EM (100 7 3 ) s r o s s e r p m o c
Figure 27 7 3 ) s r o s s e r p m o c 0 8 ( B N
Figure 28 8 3 l e b a l g n i k c a p s t n e n o p m o C
COMPRESSORS
HANDBOOK
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 8 - 98
Figure 29 Single Compressor Package 39
Figure 30 Rubber Grommets Assembling Process 70
Figure 31 Rubber Grommets 71
Figure 32 Rotalock Valve 74
Figure 33 Valve Position 75
COMPRESSORS
HANDBOOK
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 9 - 98
INDEX OF TABLES
Table 1 Compressor Series - Application - Refrigerants 13
Table 2 Applications 13
Table 3 Electrical motor starting torque classification 14
Table 4 Electrical motor types 14
Table 5 Voltages & Frequencies 15
Table 6 Electrical components 16
Table 7 Cooling Types 16
Table 8 Wiring Diagram 23
Table 9 IP Degree 30
Table 10 Maximum level of residual humidity 31
Table 11 Lubricant oils used in the compressors 32
Table 12 Minimum quantity of oil 32
Table 13 Special Version Examples 33
Table 14 Characteristics of carton multiple packages 34
Table 15 Characteristics of returnable multiple wood packages 36
Table 16 Load Characteristics for 20' container 41
Table 17 Characteristics of load by truck 41
Table 18 Acceptable compressor position during transportation 42
Table 19 Maximum height for multiple throwaway carton packages 43
Table 20 Maximum height for multiple returnable packages 44
Table 21 R134a Physical Characteristics 49
Table 22 R134a Ecological Characteristics 49
Table 23 R600a Physical characteristics 52
Table 24 R 600a Ecological Characteristics 52
Table 25 R 404A Physical Characteristics 54
Table 26 R 404A Ecological Characteristics 54
Table 27 R 407C Physical Characteristics 57
Table 28 R 407C Ecological Characteristics 57
Table 29 R290 Physical Characteristics 60
COMPRESSORS
HANDBOOK
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 10 - 98
Table 30 R290 Ecological Characteristics 60
Table 31 Suggested Filter Dryer 62
Table 32 Inconvenient caused by moisture in the system 62
Table 33 Choice of Capillary 63
Table 34 Rubber Grommets 71
Table 35 Suggested tightening torques 74
Table 36 Fan Coolers Characteristics 75
Table 37 Maximum Refrigerant Charge 76
Table 38 Discharge gas maximum pressures 79
Table 39 Pressure limit value 82
Table 40 Troubleshooting and service chart 84
COMPRESSORS
HANDBOOK
Chapter
TECHNICAL DOCUMENTS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 11 - 98
1 TECHNICAL DOCUMENTS
The technical and technical-commercial documents oI Aspera compressors produced by Embra-
co Europe are available in the Iollowing types:
1.1 GENERAL CATALOG
This technical-commercial catalog includes inIormation about all gas reIrigerants that are ap-
proved by Embraco Europe and organizes all compressors into diIIerent series and applications
(LBP, MBP, HBP, Air Conditioning) divided by 50 Hz or 60 Hz Irequency.
The inIormation in the general catalog is as Iollows:
Product inIormation
Gas reIrigerant application guide
General technical data
Nominal perIormance and en ergy cons umption ac cording to 'sub-cooled liqu id and
EN 12900 CECOMAF test conditions (only Ior models with reIrigerant R134a and R600a in
50Hz).
ReIerence table Ior identiIying drawings and diagrams oI each compressor model.
External view oI the compressor with principal dimensions.
IdentiIication nameplates
Grommets and sleeves
Assembling process
Wiring diagrams
Electrical connections
1.2 GENERAL GUIDE OF COMPRESSORS
This technical-commercial guide represents a quick reIerence Ior choosi ng compressors. It in-
cludes inIormation about all gas reIrigerants that are approved by Embraco Europe and organizes
all compressors into diIIerent series and applications (LBP, MBP, HBP and Air conditioner di-
vided by 50Hz or 60Hz Irequency.
The inIormation in the guide is as Iollows:
IdentiIication table oI available Aspera voltage and Irequency codes.
Nominal perIormance and energy consumption according to the 'sub-cooled liquid and EN
12900 CECOMAF test conditions.
1.3 TECHNICAL BULLETIN
This document contains exclusive compressor technical data:
External view oI the compressor with principal dimensions
Mechanical characteristics
Electrical characteristics oI motor and components
COMPRESSORS
HANDBOOK
Chapter
TECHNICAL DOCUMENTS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 12 - 98
Wiring diagrams
Graphs of Mass Flow, Current Input, Watt Input, Refrigeration Capacity, as a func-
tion of the evaporating temperature (within the characteristic field) at two or more condens-
ing temperatures.
1.4 ELECTRICAL COMPONENT CATALOG
This catalog allows the identification of the electrical components to be supplied with the Com-
pressor Model and its Bill of Lading.
The information contained in the catalog is:
Reference of Compressor Model & Bill of Lading.
Compressor electrical data (Voltage & frequency, motor type, nominal Watt, nominal FLA,
LRA, and resistance of the electrical motor).
Starting relay & O/L protector characteristics and code numbers used by Aspera and suppli-
ers.
Run & start capacitors (if applicable) characteristics and Aspera code number.
Terminal board assembly or El
The use of electrical components different that those approved by Embraco can cause
abnormal working and even severe damage to compressor.
ectrical box Aspera code number.
1.5 COMPRESSOR HANDBOOK
The Handbook includes useful information about compressors and their components and ad-
dresses the correct application of the compressors with various refrigerants.
1.6 ELECTRONIC CATALOG
The Electronic Catalog is available on our web site www.embraco.com.
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 13 - 98
2 GENERAL INFORMATION
2.1 COMPRESSOR RANGES
Table 1 indicates the refrigerant types used in the compressors available on catalog for each se-
ries and according to the different applications.
Table 1 Compressor Series - Application - Refrigerants
The available models in the different applications, the thermodynamic and electrical performanc-
es, the external dimensions and the approved electrical components, are listed in the General Cat-
alog, Technical Bulletin, Electrical Components Catalog and Electronic Catalog, which
complement this Handbook.
2.2 APPLICATIONS
Table 2 Applications
SERIES
APPLICATION
LBP MBP HBP AC
EM R134a - R600a R134a - R600a
NB
R134a - R600a - R404A -
R507
- R404A - R290 R404A - R290
R404A - R507 R22 - R134a
NE
R22 - R134a - R404A - R507 -
R290
R404A - R507 R22 - R134a -
R600a
R22 - R407C
T - NT
R22 - R134a - R404A - R507 -
R290
R404A - R507
R290
R290
R22 - R134a -
R22 - R407C
NJ R22 - R134a - R404A - R507 R404A - R507 R22 - R134a R22 - R407C
TYPE DESCRIPTION
LBP
(Low Back Pressure)
Models at low evaporating temperatures, suitable for applications with working
evaporating temperatures lower than -20 C; for instance refrigerators, freezers,
frozen food cabinets, frozen food display cases, display windows, etc.
MBP
(Medium Back Pressure)
Models for medium evaporating temperatures, suitable for applications with work-
ing evaporating temperatures higher than -20 C; such as fresh food cabinets, drink
coolers, ice makers etc.
HBP
(High Back Pressure)
Models at high evaporating temperatures, suitable for applications with working
evaporating temperatures higher than -15 C; such as fresh food cabinets, drink
coolers, ice makers, dehumidifiers etc.
AC
(Air Conditioning)
Models for air conditioning with R22, suitable for applications with positive work-
ing evaporating temperatures, such as air conditioners, heat pumps and dehumidifi-
ers.
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 14 - 98
2.3 STARTING TORQUE CLASSIFICATION
Table 3 describes the types oI starting torque Ior the electrical motors oI Aspera and Embraco
compressors produced by Embraco Europe.
Table 3 Electrical motor starting torque classification
2.4 ELECTRIC MOTOR TYPES
Table 4 describes the diIIerent types oI electric motors used in Aspera compressors.
Table 4 Electrical motor types
TYPE DESCRIPTION
LST
Low Starting Torque
LBP - MBP - HBP - AC applications with RSIR - RSCR - PSC electric motors.
Execution suitable Ior systems with a capillary tube or with balanced pressures at
start up.
HST
High Starting Torque
LBP - MBP - HBP applications with CSIR- CSR electric motors.
Execution suitable Ior systems with expansion valve or capillary, with unbalanced
pressures at start up.
TYPE DESCRIPTION
RSIR
Resistance Start - Inductive Run
This motor type, used in the compressor oI small power, has a low starting torque
(LST) and mu st be applied only to capi llary tube systems where the pressures
equalize. The motor is characterized by a start winding with high ohmic resistance
and must be disconnected when it reaches the stabilized rotational speed. An elec-
tromagnetic relay, calibrated Ior the motor current, disconnects the start winding at
the end oI the start up. An alternative to the electromagnetic relay is, Ior some
models, a PTC solid state-starting device.
CSIR
Capacitive Start - Inductive Run
Similar to R SIR mo tor, but wit h a di IIerent st art winding in seri es with a start
capacitor oI suitable capacitance to get a high starting torque.
RSCR
Resistance Start - Capacitive Run
Similar to RSIR motor version but uses a PTC solid state starting device and a per-
manent connected run capacitor to improve its eIIiciency.
PSC
Permanent Split Capacitor
PSC versi on wi th capacitive run wi nding. This motor is characterized by the run
capacitor permanently connected in series with the start winding; both remain con-
nected even aIter the motor starts. The starting torque is enough to guarantee that
the compressor starts only with balanced pressures in capillary tubes systems or
with a pressure equalizer.
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 15 - 98
2.5 VOLTAGES & FREQUENCIES
Table 5 are indicates the various rated voltages and frequencies with the corresponding operating
ranges and minimum starting voltages of the compressors.
Table 5 Voltages & Frequencies
CSR
Capacitive Start & Run
CSR version with capacitive run and start windings. Same as PSC motor but with a
start capacitor in series with the start winding. A potential starting relay, calibrated
for each motor, disconnects the start capacitor at the end of the start. The motor is
characterized by a high starting torque (HST) and high efficiency.
3
Three phase
Three-phase windings with star connections.
PLEASE NOTE: Not all voltages and frequencies are available on all compressors. For the availability
of different voltages and frequencies for each model and refrigerant type consult the Aspera Compressor
Catalog. For the different versions availability, please check with the Embraco Europe Sales & Marketing
Department.
ASPERA
CODE
RATED VOLTAGE & FREQUENCY
(1)
VOLTAGE WORKING RANGE MINUMUM START
VOLTAGE
@ 50 HZ @ 60 HZ @ 50 HZ @ 60 HZ
A 220-240 V 50 Hz 1~ 198 V 254 V 187 V
B 200-230 V 50 Hz 1~ / (208-230 V 60 Hz 1~) 180 V 244 V 187 V 244 V 170 V 177 V
V 7 8 1 V 2 4 2 V 0 0 2 ~ 1 z H 0 5 V 0 2 2 C
D 208-230 V 60 Hz 1~ / (200 V 50 Hz 1~) 180 V 220 V 187 V 244 V 170 V 177 V
G 115 V 60 Hz 1~ / (100 V 50 Hz 1~) 90 V 110 V 103 V 127 V 85 V 98 V
J 230 V 60 Hz 1~ / (200 V 50 Hz 1~) 180 V 220 V 207 V 253 V 170 V 195 V
K 200-220 V 50 Hz 1~ / (230 V 60 Hz 1~) 180 V 234 V 207 V 253 V 170 V 195 V
M 380-420 V 50 Hz 3~ / (440-480 V 60 Hz 3~) 332 V 445 V 396 V 509 V 323 V 374 V
N 200-240 V 50 Hz 1~ / (230 V 60 Hz 1~) 180 V 254 V 207 V 253 V 170 V 195 V
V V 0 7 1 0 7 1 180 V 220 V V 0 2 2 V 0 8 1 ~ 3 z H 0 6 / 0 5 V 0 0 2 R
V 5 8 V 5 8 V 0 1 1 V 0 9 V 0 1 1 V 0 9 ~ 1 z H 0 6 / 0 5 V 0 0 1 Q
323 V 342 V 418 V 380 V 60 Hz 3~ P
T 220-230 V 50 Hz 1~ 198 V 244 V 187 V
V 7 8 1 V 2 4 2 V 0 0 2 ~ 1 z H 0 6 V 0 2 2 U
V 5 9 1 V 3 5 2 V 7 0 2 ~ 1 z H 0 5 V 0 3 2 V
V 7 8 1 V 7 8 1 V 2 4 2 V 0 0 2 V 2 4 2 V 0 0 2 ~ z H 0 6 / 0 5 V 0 2 2 W
(1) Voltage/Frequency range indicated in brackets may not be included in Agency Approvals.
TYPE DESCRIPTION
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 16 - 98
2.6 COMPRESSOR ELECTRICAL COMPONENTS
The intended electrical components for each type of electric motor are indicated in Table 6 and
are usually supplied as compressor equipment.
Only under some circumstances agreed on with the customer, can the electrical components be
excluded from the compressor equipment.
Table 6 Electrical components
2.7 COMPRESSOR COOLING TYPES
Table 7 lists the various cooling types intended for each compressor model, as indicated in the
Compressor Catalog and Technical Bulletin.
For information on the proper installation and cooling of the compressor, consult section
6.10 - COMPRESSOR COOLING.
Table 7 Cooling Types
MOTOR
TYPE
OVERLOAD
PROTECTOR
STARTING DEVICE CAPACITORS
CURRENT
RELAYS
VOLTAGE
RELAYS
PTC START RUN
RSIR YES YES
(1)
YES
(1)
CSIR YES YES YES
RSCR YES YES YES
PSC YES YES
CSR YES YES YES YES
3 YES
(1) For some RSIR models in the NB series, a PTC starting device can be used as an alternative to the current relay.
For the RSIR compressors in the BP and EM series, the PTC starting device is standard. Only some specific HBP models in the BP
series can use a current relay.
TYPE DESCRIPTION
S
Static cooling: the compressor does not require forced cooling, but it must be
installed so that the ambient air can adequately cool to avoid overheating.
F
Fan cooling: the compressor requires forced cooling through the use of a fan, sized
as indicated in section 6.10 Compressor Cooling.
OC
With oil cooler: coil positioned in the lower internal part of the housing, immersed
in the lubrication oil, where the gas coming from the first part of the heat
exchanger circuit circulates.
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 17 - 98
2.8 COMPRESSOR NAMEPLATES - IDENTIFICATION DATA
Legend 1 Identification data in the nameplates:
Figure 1 Metallic Nameplates (used up to 2001)
Figure 2 Adhesive Nameplates
1 Compressor Model (see Figure 6a) 8 ReIrigerant
2 Bill oI Materials (see Figure 7) 9 Agency Approvals
3 Supply Voltage 10 Control Digits
4 Current Consumption (when applicable) 11 Lubricant Type and Quantity
5 Locked Rotor Current (when applicable) 12 ManuIacturing Date (d.m.y) or Date Code
6 Serial Number 13 ManuIacturing Country (Italy, Slovakia)
7 ManuIacturing Data Code (see Figure 8)
aT001
aT003
1
3 4
3 5
3 7 6
13
8
9
2
MADE IN
THERMALLY
PROTECTED
THERMALLY PROTECTED
NOSTART WITHOUT STARTINGDEVICE
1
3
3 8
13
5
2 12 6
R 134a
9
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 18 - 98
Figure 3 Series NB/NE - Adhesive Nameplates (used up to 2003)
Figure 4 Series BP - Adhesive Nameplates (used up to 2004)
Figure 5 Series EM - Adhesive Nameplates
Suction arrow on right side aT005
aT009
aT019
MADE IN ITALY
THERMALLY PROTECTED
11
5
3
4
10
6
9
2
1
R 134a
SUCTION
2123
1
S
U
C
T
IO
N
THERMALLY
PROTECTED
2120
2
3
11
6
10
4 5
MADE IN ITALY
8
9
NO START WITHOUT STARTING DEVICE
THERMALLY PROTECTTED
1
4 5
3
11 IPH
9
8
13
2 12 6
SUCTION
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 19 - 98
Figure 6a Compressor Model Identification Code
aCC001e
APPLICATION CODE
1. LBP - LST
2. LBP - HST
3. LBP - LST - Oil Cooler
4. LBP - HST - Oil Cooler
5. HBP - LST or MBP - LST
6. HBP - HST or MBP - HST
7. AC
9. MBP/HBP - HST
REFRIGERANT TYPE CODE
AND POSSIBLE DESIGN ALTERNATIVES
M
K
T
U
Y
First Generation
Second Generation
Third Generation
Fourth Generation
Fifth Generation
REFRIGERATION CAPACITY
ENERGY EFFICIENCY LEVEL
The first digit indicates the number
of zeros to be added to the 2
following digits to get the rated
capacity at 50 Hz. (In the indicated
example the capacity is 58 Kcal/h).
A - B - C - D
E - F - G
K - J - L
M - N
P
R
S - T
U
V
Y
Z - ZH - H
ZX
GE - GF - GG
GJ - GK
GS
GP
R12 single phase
R22 single phase
R502 single phase
R12 three phase
R22 three phase
Gas recycling
R502 three phase
R290 single phase
R290/R600a single phase
R600a single phase
R134a single phase
R134a three phase
R407C single phase
R404A single phase
R404A three phase
R407C three phase
NE K 2 134 GK
EM-NB-NE-T-NT-NJ
COMPRESSOR SERIES
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 20 - 98
Figure 6b Series EM - Compressor Model Identification Code
aCC002e
EFFICIENCY LEVEL
S
T
U
Y
Z
X
Standard
First Generation
Second Generation
Third Generation
Fourth Generation
Fifth Generation
2C Sixth Generation
EM
SERIES
R
P
C
X
Relay
PTC + Optional Run Capacitor
PTC + Mandatory Run Capacitor
Relay + Mandatory Start
Capacitor
EM S 36 H L P
COOLING CAPACITY
ELECTRICAL COMPONENTS
L
H
LBP
HBP
APPLICATION
Blank
H
C
R 12
R 134a
R 600a
U R 290
REFRIGERANT
Rated cooling capacity divided by
10 expresse in Btu/h (subcooled
liquid conditions) and referred to
the frequency listed on the
compressor nameplate.
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 21 - 98
Figure 7 Compressor Bill of Materials Code
Figure 8 Manufacturing Date Code
aCC003e
aCC004e
2 9 4 B A 5 0 8 1 A N
COMPLETE BOM CODE
(Listed on shipping documents and invoices)
BOM CODE ON NAMEPLATE
TYPE, SERIES, CLASS CODES
MODEL CODE
VOLTAGE & FREQUENCY SUPPLY CODE (see Table 5)
EXTERNAL VERSION CODE
ELECTRICAL COMPONENTS CODE
ACCESSORIES CODE
PACKING CODE
A B
A SEPTEMBER =
B OCTOBER =
C NOVEMBER =
D DECEMBER =
E JANUARY =
F FEBRUARY =
B 1990 / 91 =
C 1991 / 92 =
D 1992 / 93 =
N 2001 / 2002 =
E 1993 / 94 =
P 2002 / 2003 =
F 1994 / 95 =
R 2003 / 2004 =
G 1995 / 96 =
S 2004 / 2005 =
H 1996 / 97 =
T 2005 / 2006 =
U 2006 / 2007 =
V 2007 / 2008 =
G MARCH =
H APRIL =
J MAY =
K JUNE =
L JULY =
M AUGUST =
R A E Y H T N O M
FROM SEPTEMBER TO AUGUST OF FOLLOWING YEAR
J 1997 / 98 =
K 1998 / 99 =
L 1999 / 2000 =
M 2000 / 2001 = A 2012 / 2013 =
W 2008 / 2009 =
X 2009 / 2010 =
Y 2010 / 2011 =
Z 2011 / 2012 =
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 22 - 98
2.9 WIRING DIAGRAMS
The following pages represent the electrical connections wiring diagrams for all the configura-
tions supplied with the compressors. On the wiring diagram, outlined with bold lines are the con-
nections already existing on the electrical components (as supplied to the customer). Dotted lines
represent the main connections which must be made by the customer. These include the thermo-
stat, the supply line and the fan motor, if applicable.
The connection screws on overload protectors, relays, terminal boxes and ground plates, are sup-
plied with a clamping torque of (0.1 0.3 Nm) (1 3 kgcm). For the final tightening during the
wiring done by the customer, we suggest to apply a torque of 0.8 1.4 Nm (8 14 kgcm) to the
screws. The final clamping torque of electrical connections screw terminals should conform to
the IEC 685-2-2 standard.
Legend 2 Wiring Diagram
Overload Protector
Integrated PTC Device
Overload Protector
Current Start Relay
Current Start Relay with Capacitor
Connections
3CR Current Start Relay 3ARR3 Start Relay
PTC Start Device
Run Capacitor
Run Capacitor
(mandatory - not supplied)
Optional Run Capacitor Start Capacitor
Fan
Lamp Pushbutton
3-Phase Motor Single Phase Motor
Low-High Pressure Switch Thermostat
Earth Connection
3-Phase Supply Pilot Circuit 24 or 220 V
Single Phase Supply
Common Common (Internal Overload Protector)
Run Start
Terminal Block
Wh White Cable Br Brown Cable
Bl Blue Cable Bk Black Cable
YG Yellow-Green Cable Re Red Cable
Connections supplied
Connections to be made by the
Customer (not supplied)
1
S R
1
S R
2
2 1
3 5 4
4 4
2
1
5
S R
M
C
S R
R
C
S
t$
C
C'
R
S
1 N L
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 23 - 98
Table 8 Wiring Diagram
The represented electrical wiring diagrams are listed on the following table:
SERIES
MOTOR
TYPE
ELECTRICAL COMPONENTS EXECUTION FIG.
EM
RSIR Faston terminal board (PTC starting device and overload protec-
tor)
9
NB
RSIR
RSCR
Standard (integrated PTC starting device and overload protector)
Standard (integrated PTC starting device, overload protector and
run capacitor)
10
T
RSIR
CSIR
Standard (current relay and overload protector)
Standard (current relay and overload protector and start capaci-
tor)
11
NB-NE
RSIR
CSIR
Cord anchorage (current relay and overload protector)
Cord anchorage (current relay and overload protector and start
capacitor)
11
T
RSIR
CSIR
Terminal board (current relay and overload protector)
Terminal board (current relay and overload protector and start
capacitor)
12
NB-NE17
RSIR
CSIR
Terminal board (current relay and overload protector)
Terminal board (current relay and overload protector and start
capacitor)
13
NB
RSIR Ptc
RSCR Ptc
Terminal board (PTC and overload protector)
Terminal board (PTC, overload protector and run capacitor)
14
T-NJ17
PSC
CSR
Standard (external overload protector and run capacitor)
Standard (3ARR3/RVA relay, external overload protector, run/
start capacitor)
15
T-NJ17
CSR Box
CSR Box
Box (3ARR3/RVA relay, internal overload protector, run/start
capacitor)
Box (3ARR3/RVA relay, external overload protector, run/start
capacitor)
16
T-NJ
CSIR
CSIR
Standard (3CR/3ARR2 current relay, overload protector and start
capacitor)
Standard (3CR/3ARR2 current relay, overload protector and start
capacitor)
17
T-NJ17
CSIR Box
CSIR Box
Box (3CR/3ARR2 current relay, overload protector and start
capacitor)
Box (3CR/3ARR2 current relay, overload protector and start
capacitor)
18
NJ
CSIR Box
3 PHASE
Box (3ARR3/RVA relay, external relay and start relay)
Standard (internal overload protector)
19
20
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 24 - 98
2.9.1 Compressor Wiring Diagram - EM Series - RSIR
The electrical connections on the terminal board can be made with 4.76mm (3/16") male quick-
connect terminations and with M 3.5 x 6 screws that are on three terminals L1-N-ground. Con-
nection for the compressor ground is with a 4.76 mm quick-connect termination.
Figure 9 RSIR Version terminal board with PTC starting device
2.9.2 Compressor Wiring Diagram NB Series RSIR-RSCR
Standard version allows electrical connection with 4.76mm (3/16") male quick-connect termina-
tions to the overload protector, PTC and grounding terminal; with M 3.5 screws on the terminal
for the starting device and for the compressor ground.
Figure 10 RSIR and RSCR Standard Version
RSIR aSE010
RSIR aSE020
RSCR (mandatory run capacitor) aSE030 RSCR (optional run capacitor) aSE040
2 1
3
C
S R
N
L
1
L
2
t
3 1 2
S
2
R
C
2 1
3
N L
t
S
2
R
C
N L
2 1
3
t
N L
t
S
2
R
C
2 1
3
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 25 - 98
2.9.3 Compressor Wiring Diagram T-NB-NE-NT Series (electrical components without
terminal board) RSIR-CSIR
The basic version allows electrical connection with 4mm eyelets to the overload protector, start
relay and compressor ground.
Figure 11 RSIR and CSIR standard version
2.9.4 Compressor Wiring Diagram T Series (electrical component with terminal board)
RSIR-CSIR
Allows electrical connection on the terminal board available in two versions:
1. Terminal board with screw connections and a 4mm eyelet ground connection.
2. 4.76mm (3/16") male quick-connect terminations and M 3.5 screws for each terminal, 4mm
eyelet for ground.
Figure 12 RSIR - CSIR terminal board version
RSIR aSE050 CSIR aSE060
RSIR aSE070 CSIR aSE080
C
S R
2 1
3
M
1
1
C
S R
2 1
3
M
2
1
2 1
3
C
S R
1
N
L
t
M
1
N
L
t
1 2
C
2 1
3
S R M
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 26 - 98
2.9.5 Compressor Wiring Diagram NB-NE-NT Series (electrical component with termi-
nal board) RSIR-CSIR
Allows for electrical connections on the terminal board with 4.76mm (3/16") or 6.35mm (1/4")
quick-connect terminations and M 3.5 screws for terminal L - N - ground.
Figure 13 RSIR and CSIR terminal board version
2.9.6 Compressor Wiring Diagram NB Series (electrical component with terminal board)
RSIR-RSCR
Allows electrical connections to the terminal board with 4.76mm (3/16) quick-connect termina-
tions and M3.5 screws for terminals L-N-ground.
Figure 14 RSIR and RSCR terminal board version with PTC starting device
RSIR aSE230 CSIR aSE231
RSIR PTC aSE200 RSCR PTC aSE201
2 1
3
C
L
N
1
t
1
S R
2 1
3
C
L
N
1
t
1 2
S R
2 1
3
C
S R
L
N
1
t
3 1 2
2 1
3
C
S R
L
N
1
t
3 1 2
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 27 - 98
2.9.7 Compressor Wiring Diagram T-NT-NJ Series PSC-CSR
Electrical connection can be made with 6.35mm (1/4") male quick-connect terminations to the
hermetic terminal and capacitors. For the screws to the relay, overload protector and ground use
4mm eyelets.
Figure 15 PSC and CSR Versions
2.9.8 Compressor Wiring Diagram NE-T-NT-NJ Series CSR BOX
Electrical connections can be made with 4mm eyelet terminals for the screws on the start relay
and on the ground screw of the box and the compressor.
Figure 16 CSR BOX with internal or external overload protector
PSC aSE120 CSR aSE130
CSR BOX aSE140
C
S R M
2 1
3
R
C
C'
S
4 4
2
1
M
2 1
3
5
WH
R
C
C'
S
4 4
2
1
M
2 1
3
5
RD
BK
GNYE
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 28 - 98
2.9.9 Compressor Wiring Diagram T-NT-NJ Series CSIR
Electrical connections can be made with 6.35mm (1/4") male quick-connect terminations to the
relay, start capacitor and hermetic terminals 4mm eyelet connections for the protector and
ground.
Figure 17 Standard CSIR (with the relay T.I. 3CR or G.E. 3ARR2)
2.9.10 Compressor Wiring Diagram T-NT-NJ Series CSIR BOX
Electrical connections can be made with 6.35mm (1/4") male quick-connect terminations to the
relay, start capacitor and hermetic terminals 4mm eyelet connections for the protector and
ground.
Figure 18 CSIR BOX (with relay T.I. 3CR or G.E. 3ARR2)
CSIR aSE150
CSIR BOX aSE160
1
C
S R
2 1
3
M
2 M
Bk
L S
GNYE
L
C
S R
2 1
3
M 1
M
2
S
RD
BK
BK
WH
COMPRESSORS
HANDBOOK
Chapter
GENERAL INFORMATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 29 - 98
2.9.11 Compressor Wiring Diagram NJ Series CSIR BOX
Electrical connections can be made with 4mm eyelet terminals for the screws on the start relay
and on the ground screw of the box and the compressor.
Figure 19 CSIR BOX (with relay G.E. 3ARR3 or AMF RVA)
2.9.12 THREE PHASE
Electrical connections can be made with 6.35mm (1/4") male quick-connect terminations to the
hermetic terminal and 4mm eyelet for ground connection.
Figure 20 Three Phase
CSIR BOX aSE170
aSE180
C
C'
4 4 1
M
2 1
3
5
RD
BK
WH
GNYE
R
2
S
M
C
S R
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR SUPPLY CONDITIONS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 30 - 98
3 COMPRESSOR SUPPLY CONDITIONS
3.1 ELECTRICAL INSULATION
All compressors are tested with high voltage to verify the electrical insulation to ground, the di-
electric strength, and in accordance with the acceptable limits of the most severe requirements
from the following standards:
CENELEC HD 277.S1 + HD 251.S3
IEC 335-2-34 + 335-1
VDE 0700 Teil 1 + Teil 34
BS 3456 - Par.3 - Sect.3-18
EN 60335-2-34 - EN 60335-1
UL 984
3.2 IP DEGREE OF PROTECTION
The degree of protection of the electrical components supplied with the compressor are listed in
Table 9 in accordance with the following standards:
IEC 529
EN 60529
Table 9 IP Degree
3.3 THE COMPRESSOR SHELL HYDROSTATIC STRENGTH
The compressor shell resists pressures above those prescribed in the following standards:
IEC 335-2-34
EN 60335-2-34
UL 984
SERIES T NB NE NT EM
NE (AC) T (AC)
NT (AC) NJ
IP DEGREE IP 31 IP 32 IP 33
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR SUPPLY CONDITIONS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 31 - 98
3.4 DEHYDRATION
Table 10 Maximum level of residual humidity
3.5 PAINTING
Black water based paint resists corrosion for 240 hours (test in humid atmosphere - ambient 43
C and relative humidity 100% - according to standard ASTM D 2247).
The compressors are supplied with the tube ends and the electrical connections on the unpainted
hermetic terminal.
3.6 COMPRESSOR PRESSURISATION
The compressor is pressurized to a pressure of about 0.2 bar with dry air (dew point lower than
-40 C); the tubes are sealed with rubber plugs to maintain this pressure.
The compressors for use with hydrocarbons are supplied without pressurization.
3.7 OIL CHARGE
Table 11 shows the lubricant charged in the various series of compressors. The quantity is indi-
cated in the General Catalog and Technical Bulletin. Only in an exceptional case, in accordance
with the Sales Department, can the compressors be shipped without oil.
In the interest of warranty, occasionally additives or substitution of the lubricant, can be made
by the customer under the approval of Embraco Europe.
A colored O stamped on the compressor cover indicates the presence and type of oil (for color
and oil type see Table 11).
The maximum humidity content in the oil is 40 ppm.
SERIES RESIDUAL MOISTURE MAXIMUM AMOUNT
EM - NB - NE 60 mg H
2
O
T - NT 80 mg H
2
O
NJ 90 mg H
2
O
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR SUPPLY CONDITIONS
Doc. Code Emission Revision Date Page
MP01E+ 2000-04 0 20-02 32 - 98
Table 11 Lubricant oils used in the compressors
3.8 MINIMUM QUANTITY OF LUBRICANT
The minimum amount of oil in the compressor that guarantees the correct lubrication is indicated
in Table 12:
Table 12 Minimum quantity of oil
Oil quantities below the minimum prescribed level will not allow the oil pump to prime and will
cause wear, leading to the eventual seizure of the mechanical parts.
SERIES STAMP
(1)
Brand Type Viscosity
(4)
Alkilbenzene
Alkilbenzene
Mineral
Mineral
Polyolester
Polyolester
Polyolester
Mineral
Reniso 46
Microlab
Avia FCA 7EP
Avia FCA 15EP
Emkarate RL 22H
Emkarate RL 10H
Emkarate RL 22HB
Avilube FC 32
R22 models
R600a EMT, EMU,
EMY, EMZ, EMX
R600a NBT, NBU, NBY
R600a NBM
R134a, R404A,
R290 EMT
R134a NBT
R134a, R404A,
R407C, R290
R22 AC models
ISO 46
ISO 5
ISO 7
ISO 15
ISO 22
ISO 10
ISO 22
ISO 32
Blue
Red
Pink
(3)
Yellow
White
(2)
Violet
(3)
(1) Color of the O stamped on compressor cover
(2) Except EMT and NBT
(3) On EM compressors no stamp, but oil type is printed in clear onto cover
(4) Except R22 AC models
SERIES EM
OIL cm
3
min. 130
NB
150
NE
200
T - NT
300
NJ
500
Violet
(3)
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR SUPPLY CONDITIONS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 33 - 98
3.9 SPECIAL VERSIONS
All special version compressors that are indicated in the catalog or that are a customer's special
request, may not be available; Table 16 shows all special versions intended for each compressor
series. For the availability of the versions in the table or the feasibility of others not mentioned,
please contact the Embraco Europe Sales Department.
Table 13 Special Version Examples
SERIES DESCRIPTION
EM Compressors with a clip on the cover for the mounting of a condensate pan.
NB NE
Compressors with Universal base plate (4 holes with a diameter of 19.05mm
with dimensions of 101.6 x 165 mm) and internal standard tube ID.
NJ
Compressors without suction tubes but with a fixture for rotalock valve (not sup-
plied).
NJ
Compressors without suction tubes but with a fixture for rotalock valve supplied
with associated parts (unassembled).
All Series Compressors without grommets and sleeves.
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 34 - 98
4 COMPRESSOR PACKAGING
4.1 MULTIPLE CARTON AND WOOD DISPOSABLE PACKAGE
This type of package consists of cartons containing one or more levels of compressors in the
quantities indicated in Table 14, secured with straps on wooden pallet skids with dimensions of
830 mm x 1130 mm and a variable height according to the compressor model. For overseas ship-
ments or in the case of difficult transport, plywood protection is available for the standard pack-
aging with the sides and cover secured with straps.
Table 14 Characteristics of carton multiple packages
Figure 21 Carton Package Unit
Wood Package Unit
Figure 22
SERIES PACKAGE UNIT Fig.
Figure 22 80, 100, 120 EM
NB NE
NB NE electricals assembled
40, 80
37, 74
T
T electricals assembled
40, 60
30
NT
NT electricals assembled
36
24
36
Figure 22
Figure 22
Figure 22
Figure 22
Figure 22
Figure 21
Figure 21 NJ
aIMA01
PACKAGE UNIT
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 35 - 98
4.1.1 Compressor Identification Marks
Tags are applied on two sides of each package and report the following data:
Figure 23 Package Label
1. Compressor Bill of Material
2. Compressor Bill of Material (Type 39 bar code)
3. Compressor Model
4. Voltage & Frequency
5. Refrigerant
6. Package Quantity
7. Package Serial Number (Type 128 bar code)
8. Package Serial Number
1 2
3 4 5
6
7
8
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 36 - 98
4.2 RETURNABLE WOOD PACKAGE
This type of package consists of a shipping skid of 790 mm x 1200 mm on which are positioned
the elements composing the packaging of various compressor layers, as listed below, secured
with straps to the shipping skid (see figures 25-26-27).
Legend 4
This type of package, created to comply to recycling regulations, requires returning to Aspera of
all components for their reuse.
Furthermore they should arrive arranged in reverse sequence (top skid, separator skid, base, ship-
ping skid) or in separated groups (all shipping skids, all bases, all separator skids and all top
skids).
Table 15 Characteristics of returnable multiple wood packages
Figure 25 EM (120 compressors)
A
SHIPPING
SKID
on which the base is positioned.
B BASE on which the first layer of compressors is positioned.
C
SEPARATOR
SKID
are positioned between layers, in quantities according to the compres-
sor series, as indicated in Table 15.
D TOP SKID upper element closing of the package.
SERIES PACKAGING TYPE
EM
120 compressors per package (6 layers of 20 compressors) Figure 25
100 compressors per package (5 layers of 20 compressors) Figure 26
NB 80 compressors per package (4 layers of 20 compressors) Figure 27
aIM120
D
C
B
A
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 37 - 98
Figure 26 EM (100 compressors)
Figure 27 (0NB (80 compressors)
4.2.1 Compressor identification marks
Two tags placed on the outer side of the package indicate the data of the contents (see 4.1.1).
aIM100
aIM080
D
C
B
A
D
C
B
A
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 38 - 98
4.3 PACKAGE FOR ELECTRICAL COMPONENTS AND ACCESSORIES
Electrical components and accessories are packed separately in carton boxes. A label is applied
showing the Iollowing data:
Legend 5 Components packing label
1. Compressor Bill oI Materials (complete oI electrical components and accessories)
2. Compressor Type
3. Required Quantity
4. Customer Name
5. List oI electrical components and accessories shipped (code / description / quantity)
Figure 28 Components packing label
AIM008
EUROPE S.r.l.
STABILIMENTO
DOCUMENTO
NUMERO DATA
COD. DISTINTA BASE
1 2 3 4
MAG.
ENTE EMITTENTE FIRMA RESPONSAB. DATA EMISSIONE ENTE RICEVENTE FIRMA RESPONSAB. VISTO
COD. DISEGNO DESCRIZIONE
5
U.M. Q.T RICH. Q.T CONS. Q.T MANC.
DESCRIZIONE MODELLO Q.T RICH. CLIENTE CAUSALE DESTINAZIONE
BUONO DI PRELIEVO
COMPONENTI ELETTRICI E ACCESSORI
COMPRESSORS
HANDBOOK
Chapter
COMPRESSOR PACKAGING
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 39 - 98
4.4 SINGLE PACKAGE
This type oI package consists oI a carton and an in ternal separator to prevent any compressor
movement.
The electric equipment is assembled on compressor, while rubber grommets and sleeves are sup-
plied unassembled, in a polyethylene bag.
The CSR-CSIR m odels i n the version with Box have some electric equipment assembled on
compressor (cover and ground screw; protector spring and overload protector when required),
while the rubber grommets and the sleeves are in a polyethylene bag.
The assembled Box (relay, capacitors, and connecting cables) is supplied in a separate package.
A new package with all components inside, included the Box, is now available.
Figure 29 Single Compressor Package
aIM007
COMPRESSORS
HANDBOOK
Chapter
HANDLING, TRANSPORTING AND STORING COMPRESSORS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 40 - 98
5 HANDLING, TRANSPORTING AND
STORING COMPRESSORS
5.1 HANDLING
The handling oI the mu ltiple packages must be done only by Iork s via 'Transpallet and 'Li It
Trucks. Access is available Irom all Iour sides oI the package. It is suggested that the use oI Iorks
having a length no longer than the size oI the pallet`s shortest side (830mm Ior throwaway cartons
or 790mm Ior wooden recycling packages), to avoid damaging the next packages and the compres-
sors inside with the Iorks protruding Irom the back side oI the pallet.
5.2 TRANSPORTING
The transportation oI all types oI packaging must be made with an upright compressor (working
position), as indicated by the vertical arrow placed on the sides oI the carton.
Follow these instructions, particularly Ior the 'Single packages, which are easier to damage.
Incorrect transport can caus e deIormation oI brackets and internal muIIlers and/or oil entering
into the suction muIIlers and stator shiIts, which can result in a reduction oI stator/rotor air gap.
The consequences during operation can appear with deIormations or breaks oI reed valves and
springs, and with starting problems oI the electric motor.
5.2.1 Shipment by container
The predominant method oI transport is by container oI which there are two diIIerent types Ior
capacity and length: 20' (about 6.1 m) and 40' (about 12.2 m). The standard cont ainer used by
Embraco Europe is the 20', which allows in comparison to the 40', a higher ratio weight/volume
and consequently a better utilization oI the internal volume.
Table 16 indicates the characteristics oI the load. For each compressor series, indicated are the
number oI layers, the package number and type Ior each layer, the total number oI compressors
and the inIormation on the packaging oI equipped components. Occasionally, some Ireight Ior-
warders in the interest oI expediency, preIer to employ a 40' container, even with the disadvan-
tage oI total volume utilization.
ATTENTION: The multiple packages must not be handled with cranes by means of cables and hooks.
Embraco Europe will not be responsible for damages to the product resulting from the use of improper han-
dling.
COMPRESSORS
HANDBOOK
Chapter
HANDLING, TRANSPORTING AND STORING COMPRESSORS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 41 - 98
Table 16 Load Characteristics for 20' container
5.2.2 Shipments by truck
The transportation of compressors by truck is the most common system for highway or short dis-
tances where the stresses on the product are reduced. This type of transportation, if made without
the necessary precautions on load steadiness and travel on uneven roads can cause stresses to
compressors with possible damages to the suspension springs and to the internal discharge muf-
flers. For an Embraco 24,000 kgs (11,000 lb) truck, the load composition is as follows in
Table 17:
Table 17 Characteristics of load by truck
SERIES
FIRST LAYER
PACK N - N COMP.
SECOND LAYER
PACK N - N COMP.
THIRD LAYER
PACK N - N COMP.
TOTAL N OF
COMPRESSORS
EM 14 - 120 14 - 60
(4)
2.520
NB 14 - 72 14 - 72
(4)
2.016
NE
(1)
14 - 72 11 - 72
) 4 ( ) 2 (
1.800
14 - 72 13 - 72
) 4 ( ) 3 (
1.944
T
(1)
14 - 36 14 - 36 7 - 36
(4)
1.260
14 - 72 14 - 36
(4)
1.512
NJ 14 - 36 11 - 36
) 4 ( ) 2 (
900
(1) The different load structure (1.800 or 1.944 NE series compressors - 1.260 or 1.512 T compressors) is determined by the ratio
between the maximum container weight and the compressor weight.
(2) No. 3 package filler is added (containing all the equipped components).
(3) A package as filler packaging, containing part of the equipped components is added.
(4) Type of load which is rarely used. To be avoided due to an incomplete 3rd layer.
Packages are added containing the equipped components.
SERIES
PACKAGE UNIT TYPE &
COMPRESSOR QUANTITY
PACKAGE N
TOTAL N OF
COMPRESSORS
EM Throwaway carton of 120 compressors 28 32 3.000 3.240
EM Recycling wooden of 120 compressors 28 32 3.000 3.120
NB-NE Throwaway carton of 72 compressors 28 32 2.016 2.304
NB Recycling wooden of 80 compressors 28 32 2.016 2.304
T Throwaway carton of 72 compressors 28 32 1.512 1.728
NJ Throwaway carton of 36 compressors 28 32 972 1.080
COMPRESSORS
HANDBOOK
Chapter
HANDLING, TRANSPORTING AND STORING COMPRESSORS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 42 - 98
5.3 ACCEPTABLE COMPRESSOR POSITIONS DURING
TRANSPORTATION
For the finished product (compressor assembled in the application), certain transportation con-
ditions do not require that the compressor is positioned upright. Table 18 represents the various
acceptable transportation positions. Any position not listed below is prohibited.
Table 18 Acceptable compressor position during transportation
For the solution of potential positioning problems during assembling and transport, please con-
sult the Technical Assistance - Sales Department.
We advise against the transport by rail, even if correctly performed, because during the shunting,
stress to the compressors from decelerations can cause stator shifts, or deformation or breaking
of brackets and internal discharge tubes.
SERIES
POSITION
Normal
(upright) Label up
Terminal board
up Label down
Terminal board
down
Upside-down
EM
T
NT
NB
NE
NJ
MAXIMUM ALLOWABLE RATE OF DECELERATION DURING THE TRANSPORT: 1g
COMPRESSORS
HANDBOOK
Chapter
HANDLING, TRANSPORTING AND STORING COMPRESSORS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 43 - 98
5.4 STORAGE
The storage of multiple packages can be done by placing one package upon another according
to the limits indicated in Table 19 and 20. The maximum allowable height is illustrated on the
two sides of the cartons making up the package unit.
Table 19 Maximum height for multiple throwaway carton packages
Throwaway packaging: 1 box + shipping skid
aIMA015
Throwaway packaging: 2 boxes + shipping skid
aIMA023
S T I N U 3 . X A M S T I N U 5 . X A M
COMPRESSORS
HANDBOOK
Chapter
HANDLING, TRANSPORTING AND STORING COMPRESSORS
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 44 - 98
Table 20 Maximum height for multiple returnable packages
All packages must be stored in places protected from humidity and bad weather, as illustrated
(open umbrella) on the external sides of the cartons.
Embraco Europe Srl does not take any responsibility for occasional damages to the pack-
age and to the finished product resulting from not observing these instructions.
returnable packages
(0NB1( Series 80 compr
aIM0804
returnable packages
EM Series - 120 compressors
aIM1203
returnable packages
EM Series -100 compressors
aIM1004
MAX. 4 UNITS MAX. 3 UNITS MAX. 4 UNITS
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 45 - 98
6 INFORMATION ABOUT CORRECT
COMPRESSOR INSTALLATION
6.1 COMPRESSOR SELECTION
The proper selection oI the compressor should be made according to the Iollowing system char-
acteristics where it will be installed:
6.1.1. Min imum evaporating temperature
6.1.2. ReIrigeration capacity
6.1.3. ReIrig erant type
6.1.4. Am bient temperature
6.1.5. Run ning voltages and Irequencies
6.1.6. Electric motor starting torque
6.1.7. Compressor cooling type
6.1.8. Noise level (iI applicable)
6.1.9. Max current input (iI applicable)
Note For the operational limits of the compressor consult section 7.1.
6.1.1 Minimum evaporating temperature
The minimum running evaporating temperature oI the syst em, along with the condensing tem-
perature, allows the id entiIication oI the com pressor appl ication and it s reIrigeration capacity
(see '2- General InIormation par. 2.2).
6.1.2 Refrigeration capacity
The required cooling capacity at standard working conditions oI the system, in Watt or kcal/h,
according to the evaporating and condensing temperatures. The capacity depends on the mass
Ilow rate, which is a Iunction oI the compressor displacement, RPM, and volumetric eIIiciency.
6.1.3 Refrigerant type
ReIrigerant selection can be made Irom the available list taking into consideration the market re-
quirements oI the product and ecological Iactors.
6.1.4 Ambient temperature
The compressor must be selected in order to ensure it is suitable to operate at the maximum re-
quired ambient temperature (e.g. temperate climate 32 C or tropical climate 43 C).
Compressors are intended Ior indoor use, and a minimum oI 5 C is required Ior working, in or-
der to have a correct lubricatio n. II ambient temperature is ar ound above value and reIrigerant
charge is approachin g or overcoming t he maximum al lowed limit, can b e useIul the use oI a
crankcase heater.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 46 - 98
6.1.5 Operating Voltages and Frequencies
The compressor must be selected according to the voltage and Irequency conditions where the
cabinet will operate in the Iield, considering the voltage Iield typical oI each motor type and their
prescribed tolerances. (See '2-General InIormation par. 2.5).
6.1.6 Electric motor starting torque
The selection oI the electric motor starting torque type (low starting torque LST - high starting
torque HST) must be made according to the suction and discharge pressures oI the system during
the compressor start. For systems with capillary tubes or expansion valves with pressure equali-
zation, a low starting torque (LST) is suitable. This compressor does not use a start capacitor, and
is able to start only with balanced suction and discharge pressures. For systems with expansion
valve where the suction and discharge pressures remain unbalanced, it is necessary to use a high
starting torque compressor (HST). See what prescribed under par. '7.1.6 - Start conditions.
6.1.7 Compressor cooling type
Smaller compressors, with relatively low power motors, can be used in a static cooled arrange-
ment. Compressors with higher power motors require Iorced ventilation. Some compressors in
the E and T series are also available with an oil cooler. This oil cooler is a coil positioned in the
lower part oI the hou sing immersed in the oil sump. (See '2.7 - COMPRESSOR COOLING
TYPES).
6.1.8 Noise level
In some applications the noise level oI the system is a consideration. Certain compressors have
been developed speciIically Ior low noise applications. In order to select the best compressor Ior
a given application, noise tests oI the complete system should be perIormed as the total noise lev-
el is related to the integration oI all components and the circulation oI the reIrigerant.
6.1.9 Maximum current input
II there are restrictions on the current absorbed by the compressor and/or on the short circuit cur-
rent LRA, you may choose a compressor which meets the requested requirements.
6.2 COMPRESSOR UNPACKING
Remove the compressor Irom th e package keepi ng it in an upright position to avoid damage.
Failure to maintain the compressor in an upright position can result in the introduction oI oil into
the suction and process connection, possibly causing welding problems. Another more serious
consequence can be the breaking oI reed valves during compressor start due to oil and the suction
muIIler. For the same reason, the compressor must remain upright while assembling the grom-
mets and sleeves to the base plate.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 47 - 98
6.3 PREPARATION OF REFRIGERATING SYSTEM COMPONENTS
The cleaning (solid substances and non-condensable) and the reduced moisture in all the compo-
nents oI the reIrigeration system, are the primary concerns Ior the compressor good running and
liIe.
With the in troduction oI R134 a and R404A reIrigerants, using new po lyolester oils, Embraco
Europe adopted strict limits in comparison with CFC - HCFC reIrigerants. By introducing some
modiIications to the production line, a drast ic reduction oI the moisture content and solid non-
condensable residue in the compressors was achieved. Furthermore, in all production processes
oI Embraco Europe and oI external suppliers, all non-compatible products that may contaminate
the new reIrigerants and the new polyolester oils have been eliminated. These include all chlorine
based compounds, as well as non ester based oils. For the same reason, Embraco Europe suggests
the use oI system components such as tubes , condensers, evaporators, oil separators, liquid re-
ceivers, valves, capillaries, etc., to have a moisture and solid and non-condensable residuals con-
tents reduced by 50 in comparison to what is prescribed by DIN 8964 Standard - and Iree oI
the contaminants mentioned in the previous paragraph.
We suggest that the components remain sealed as long as possible before their assembly,
performing the welding no later than 15 minutes from assembling the components.
To avoid oil residuals during the welding process, it can be useIul to blow out these components
with nitrogen or dry air, with a dew point lower than -40 C, beIore using them. These instruc-
tions can be taken as a reIerence also Ior systems using CFC - HCFC reIri gerants (R12-R22-
R502- etc.) and isobutane (R600a), even iI these reIrigerants do not require such strict require-
ments as R134a and R404A.
We suggest removing the rubber plugs Irom the tubes oI the upright compressor in the Iollowing
sequence: discharge tube, suction tube and service tube.
A diIIerent sequence can cause oil being carried out oI the compressor by the internal pressuri-
zation. This can cau se subsequent welding diIIiculties on the tub es and internal contamination
due to oil residues.
The internal oiling oI the tubes can make the welding diIIicult, and moreover it can introduce
contaminants into the system due to 'oil cracking.
Embraco Europe Srl is not responsible for any damage to the compressor caused by the use
of inappropriate components and production processes and products not compatible with
the new refrigerants and lubrication oils.
On page 62, Tabl e 32 indicates the po ssible probl ems in t he system coming Irom a residual
moisture content higher than the above indicated limits. As residual moisture, moisture remain-
ing in the running system may not be absorbed by the molecular sieve oI the Iilter.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 48 - 98
6.4 REFRIGERANT USE GUIDE
Access to inIormation about, and application oI, the new reIrigerants allows the manuIacture re-
liable equipment that is correctly dimensioned and operates under saIe conditions.
In this section, presented are some guidelines Ior the use oI the Iollowing reIrigerants: R134a -
R600a - R404A - R407C - R290.
Because of the vast differences between systems and different working fields typical of each
application, the reliability of the equipment should be defined by appropriate life and field
tests.
All operations related to the use of refrigerants should be performed in accordance with
local laws and rules related to this subject.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 49 - 98
6.4.1 Guide for the use of R134a
6.4.1.1 General information
The R134a reIrigerant (1.1.2.2 - tetraIluorethylene) is used to replace the R12 in applications
with low, medium and high evaporator temperatures.
Table 21 R134a Physical Characteristics
Table 22 R134a Ecological Characteristics
6.4.1.2 System components compatibility
All reIrigeration system components should be compatible with the reIrigerant and lubricant
used in the compressor. Substances containing chlorine, mineral oils, paraffin and silicone are
not approved.
All equipment used in the reIrigerator manuIacturing process that require lubrication and may
come into contact with the reIrigeration system components, must use exclusively polyolester oil
as a lubricant (suggested viscosity 18 - 20 cSt 40 C). Due to the strict requirements associated
with the use oI the R134a, particular attention must be given to the internal cleanliness oI the sys-
tem. The above mentioned substances as well as any solid residues (dust, metal particles, etc...)
must not be introduced into the system. It is recommended that the maximum level oI the con-
tamination should be 50 less than what is prescribed in norm DIN 8964
(1)
.
6.4.1.3 Expansion device
Capillary tubes: For a new application, the Iirst component to be dimensioned should be the
capillary tube. To prepare the prototype, use chapter 6.6 - Capillary Tubes Selection as a reIer-
ence.
As a general rule, to convert a system Irom R-12 to R134a, the same capillary tube may be used.
It is not recommended to use a capillary tube with an internal diameter less than 0.6 mm.
For each system, the optimal dimensioning oI the capillary tube should be perIormed in an ap-
propriate test laboratory in order to obtain the best working conditions, and to avoid the return oI
liquid reIrigerant to the compressor.
Expansion Valve: Should be selected according to the working temperatures and pressure char-
acteristics oI reIrigerant R134a.
6.4.1.4 Evaporator and condenser
Generally to convert a system Irom R-12 to R134a, the same evaporator and condenser tube may
be used.
Molecular Weight 102 (ReI.: R 12 120.9)
Critical Temperature 101.1 C (ReI.: R 12 111.8 C)
Critical Pressure 40.6 bar (ReI.: R 12 41.1 bar)
Boiling Point -26.5 C (ReI.: R 12 -29.8 C)
ODP (Ozone Depletion Potential) 0 (ReI.: R 12 1)
GWP (Global Warming Potential) 1300 (100 years) (ReI.: R 12 8501)
(1) The soluble residual contents and solid residues must be less than 100mg /m
2
of system internal surface area. Of this,
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 50 - 98
6.4.1.5 Filter dryer
It is recommended to use a Iilter dryer, such as XH7, that is compatible with the reIri gerant
R134a and the compressor oil. (ReIer to chapter 6.5 - Selection oI the Filter Dryer).
The Iilter should have a molecular sieve oI no less than 3 Angstrom.
It is suggested to increase the mass oI the molecular dryer 15 to 20, compared to the one used
with reIrigerant R 12.
Always consult the manuIacturer Ior the proper selection oI a Iilter dryer.
6.4.1.6 Evacuation and charging equipment
Generally the vacuum level Ior a R134a system is the same used Ior a system with R 12.
Good reIrigeration practice suggests system evacuation Irom both low side and high side, achiev-
ing a minimum level oI 0.14 mbar (100 Hg) with a non-condensable value oI less than 0.3 by
volume.
Use charging equipment suitable Ior use oI the reIrigerant R134a, and iI possible, dedicate this
machine Ior use only with reIrigerant R134a.
6.4.1.7 Refrigerant charge
Generally the quantity oI the reIrigerant R134a introduced into the system can be reduced Irom
5 to 20, compared to the required charge oI R 12.
For each system, the optimal reIrigerant charge should be determined in an appropriate test lab-
oratory in order to obtain the best working conditions, and to avoid the return oI liquid reIrigerant
to the compressor.
ReIrigerant R134a should not have any contamination; even a small amount oI a Chlorine based
reIrigerant can cause problems.
6.4.1.8 Moisture
In order to avoid problems that can shorten liIe oI the reIrigeration system, use components that
are supplied internally dried and properly sealed, to prevent the entrance oI moisture. These com-
ponents should remain sealed until they are used.
It is recommended to avoid leaving the compressor and components exposed to the ambient Ior
more than 15min.
II there is doubt about the presence oI moisture in a component; it may be dried by blowing dry
air (with a dew pont below -40 C) through the internal surIace Ior a suIIicient time period.
It is recommended to maintain moisture content in the system 50 lower than it is prescribed by
norm DIN8964.
The level oI moisture present in the reIrigeration circuit should be below 40ppm and aIter the
system has been operating, the Iilter dryer should remove moisture Irom the system Irom a level
below 20ppm.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 51 - 98
6.4.1.9 Leak control
It is recommended that special attention be given to the correct welding oI the system compo-
nents to avoid the possibility oI leaks. This is due to the smaller molecular dimensions oI reIrig-
erant R134a.
To guarantee the maximum eIIiciency in controlling leaks, it is recommended to use a leak de-
tector designed Ior use with reIrigerant R134a, or as an alternative, a detector designed Ior use
with Helium.
6.4.1.10 Equalization time for suction and discharge pressures
The use oI the reIrigerant R134a requires signiIicantly more time Ior the suction and discharge
pressures to equalize compared to R 12. Because oI this, the compressor should be selected ac-
cordingly to allow Ior this longer equalization time.
6.4.1.11 High pressure limit control
To protect the system, it may be necessary to install a high pressure limit switch to control the
maximum discharge pressure. The settings on this limit switch should be in accordance with the
limits established in Chapter 7.1.3 - Discharge gas maximum pressures.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 52 - 98
6.4.2 Guide for the use of R600a
6.4.2.1 General information
The reIrigerant R600a (isobutane) is used to subst itute R 12 as an alternative to R 134a, primarily
in domestic reIrigerators and Ireezers.
BeIore supplying compressors Ior use with R600a, it is Iirst necessary to perIorm an evaluation
oI the risks involved with the use oI this reIrigerant. The customer should perIorm a risk assess-
ment to ensure proper knowledge about the handling and use oI the R600a in the reIrigerant sys-
tem ( Ior Iurther inIor mation please contact the Technical A ssistant Department at Embraco
Europe).
When converting a system Irom R12 to R600a, the displacement oI the compressor is increased
by approximately 90 while the charge oI the reIrigerant is reduced by 50.
Table 23 R600a Physical characteristics
Table 24 R 600a Ecological Characteristics
PLEASE NOTE: R600a is flammable and should then be handled by qualified personnel in accordance
with the rules and regulations now established for safe use.
6.4.2.2 System component compatibility
All oI the components in the reIrigeration system that may contain contaminants, should conIorm
to the requirements outlined in norm DIN8964
(1)
. The presence oI the contaminants paraIIin and
silicon are not permitted.
6.4.2.3 Expansion device
Generally, when changing a system Irom R12 to R600a, the same capillary tube can be used.
It is not recommended to use a capillary tube with an internal diameter less than 0.6 mm.
For each system the optimal dimensioning oI the capillary tube should be perIormed in an appro-
priate test laboratory, in order to obtain the best working conditions.
Recommended Purity 99.5
Maximum Allowable Impurities
Propane 0.2 maximum, Air100 pp max, Water 10
ppm max, Silicon Oil 5 ppm max, Sulphur and com-
pounds 1 ppm max, Nbutane 0.3 max.
Molecular Weight 58.1 (ReI.: R 12 120.9)
Critical Temperature 134.7 C (ReI.: R 12 111.8 C)
Critical Pressure 36.5 bar (ReI.: R 12 41.1 bar)
Boiling Point -11.7 C (ReI.: R 12 -29.8 C)
Flammability in Air
Minimum limit. LEL 1.8 in vol.;
Maximum limit UEL 8.5 in vol.
ODP (Ozone Depletion Potential) 0 (ReI.: R 12 1)
GWP (Global Warming Potential) 3 (100 years) (ReI.: R 12 8501)
(1) The soluble residual contents and solid residues must be less than 100mg /m
2
of system internal surface area. Of this,
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 53 - 98
6.4.2.4 Evaporator and condenser
Generally to convert a system Irom R-12 to R600a, the same evaporator and condenser may be
used.
The internal circuit oI the evaporator should be veriIied because there may be regions that may
tend to trap oil and can temporarily prevent reIrigerant Ilow.
6.4.2.5 Filter dryer
ReIrigerant R600a requires the use oI a normal Iilter drier type 4A-XH5 or better (see chapter
6.5 - Filter Dryer).
Always consult the manuIacturer Ior the proper selection oI the Iilter drier.
6.4.2.6 Evacuation and charging equipment
Generally the vacuum level Ior a R600a system is the same used Ior a system with R 12.
Good reIrigeration practice suggests system evacuation Irom both low side an d high side and
achieving a minimum level oI 0.14 mbar (100 Hg) with a non condensable value oI less than
0.3 by volume.
Use charging equipment suitable Ior use oI the reIrigerant R600a.
6.4.2.7 Refrigerant charge
Generally the quantity oI the reIrigerant R600a introduced into the system can be reduced Irom
50-60 compared to the required charge oI R 12.
This characteristic greatly reduces the legal risk oI Ilammability oI the reIrigerant in case oI a
system leak.
For each system, the optimal reIrigerant charge should be determined in an appropriate test lab-
oratory in order to obtain the best working conditions.
6.4.2.8 Moisture
In order to avoid problems that can shorten liIe oI the reIrigeration system, use components that
are internally dry and p roperly sealed to pre vent the entran ce oI moisture. These components
should remain sealed until they are used.
The moisture content in a system should conIorm t o norm DIN8964. The level oI moisture
present in the reIrigeration circuit should be below 40ppm and aIter the system has been operat-
ing, the Iilter dryer should remove moisture Irom the system Irom a level below 20ppm.
6.4.2.9 Leak control
It is recommended that special attention be given to the correct welding, or other Iorms oI union
oI the system components, to avoid the possibility oI leaks.
To guarantee the maximum eIIiciency in controlling leaks, it is recommended to use a leak de-
tector designed Ior use with reIrigerant R600a, or as an alternative, a detector designed Ior use
with Helium.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 54 - 98
6.4.3 Guide for the use of R404A
6.4.3.1 General information
ReIrigerant R404A can normally be used as a substitute to the Iollowing reIrigerants:
R22 Ior applications in medium temperatures
R502 Ior applications in low temperatures
Table 25 R 404A Physical Characteristics
Table 26 R 404A Ecological Characteristics
6.4.3.2 System components compatibility
All reIri geration system components should be compatible with the reIrigerant and lubricant
used in the compressor. Substances containing chlorine, mineral oils, paraffin and silicone are
not approved.
All equipment used in the reIrig erator manuIacturing process that require lubrication and may
come into contact with the reIrigeration system components, must use exclusively Polyolesther
oil as a lubricant (suggested viscosity 18 - 20 cSt 40 C). Due to the strict requirements asso-
ciated with the use oI the R404A, particular attention must be given to the internal cleanliness oI
the system. The above-mentioned substances as well as any solid residues (dust, metal particles,
etc...) must not be introduced into the system.
It is recommended that the maximum level oI the contamination should be 50 less than what
is prescribed in norm DIN 8964
(1)
.
6.4.3.3 Expansion device
Capillary tubes: For a new application, the Iirst component to be dimensioned should be the
capillary tube. To prepare the prototype, use chapter 6.6 - Capillary Tubes Selection as a reIer-
ence.
Generally, to convert a system Irom R502/R22 to R404A, the same capillary tube may be used.
It is not recommended to use a capillary tube with an internal diameter less than 0.6 mm.
For each system, the optimal dimensioning oI the capillary tube should be perIormed in an ap-
propriate test laboratory in order to obtain the best working conditions, and to avoid the return oI
liquid reIrigerant to the compressor.
Expansion Valve: Should be selected according to the working temperatures and pressure char-
acteristics oI reIrigerant R404A.
Near-azeotropic Mixture - Three HFC components
R 125 (pentaIluorethane)
44%
R 143a (111-triIluorethane)
52%
R 134a (1112 tetraIluorethane)
4%
Boiling Point Temperature 46.3 C (ReI.: R 12 29.8 C)
Glide ( evaporation temperature Ior the three components) < 0,5 C
ODP (Ozone Depletion Potential) 0 (ReI.: R 22 0,05)
GWP (Global Warming Potential) 3750 (100 years)
(ReI.: R 22 1700;
R 502 5590)
(1) The soluble residual contents and solid residues must be less than 100mg /m
2
of system internal surface area. Of this,
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 55 - 98
6.4.3.4 Evaporator and condenser
The operating pressures oI R404A are higher than those oI R22 and R502 and thereIore require
a larger condenser and evaporator than the systems using R22 or R502.
6.4.3.5 Filter dryer
It is recommended to use a Iilter dryer, such as XH9, that is compatible with the reIrig erant
R404A and the compressor oil. (ReIer to chapter 6.5 - Selection oI the Filter Dryer).
The Iilter should have a molecular sieve oI no less than 3 Angstroms.
It is suggested to increase the mass oI the molecular dryer 15 to 20, compared to the one used
with reIrigerant R502/R22.
Always consult the manuIacturer Ior the proper selection oI a Iilter dryer.
6.4.3.6 Evacuation and charging equipment
Generally the vacuum level Ior an R404A system is the same used Ior a system with R502/R22.
Good reIrigeration practice suggests system evacuation Irom both low side and high side, achiev-
ing a minimum level oI 0.14 mbar (100 Hg), with a non-condensable value oI less than 0.3
by volume.
Use charging equipment suitable Ior use oI the reIrigerant R404A, and iI possible, dedicate this
machine Ior use only with reIrigerant R404A.
6.4.3.7 Refrigerant charge
Generally, the quantity oI t he reIrigerant R404A introduced into the system can be reduced to
80-90 compared to the required charge oI R502/R22.
For each system the optimal reIrigerant charge should be accurately deIined (reduced to the min-
imum necessary) only aIter perIorming appropriate laboratory tests have been perIormed on the
system. This must be done in order to obtain the best working conditions and to avoid the return
oI liquid reIrigerant to the compressor during running and the migration oI gas during the oII-
cycle.
ReIrigerant R404A should not have any contamination; even a small amount oI a Chlorine-based
reIrigerant can cause problems.
ReIrigerant R404A, a near-azeotropic mixture, must be charged into the system only in the liquid
phase to guarantee that the composition oI the reIrigerant remains constant.
6.4.3.8 Moisture
In order to avoid problems that can shorten liIe oI the reIrigeration system, use components that
are internally dry and p roperly sealed to pre vent the entran ce oI moisture. These components
should remain sealed until they are used.
It is recommended to avoid leaving the compressor and components exposed to the ambient Ior
more than 15min.
II there are doubts about the presence oI moisture in a component, it may be dried by blowing
dry air (with a dew point below -40 C) through the internal surIace Ior a suIIicient time period.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 56 - 98
It is recommended to maintain moisture content in the system 50 lower than it is prescribed by
norm DIN8964
(1)
.
The level oI moisture present in the reIrigeration circuit should be below 40ppm. AIter the sys-
tem has been operating, the Iilter dryer should remove moisture Irom the system Irom a level be-
low 20ppm.
6.4.3.9 Leak control
It is recommended that special attention be given to the correct welding oI the system compo-
nents to avoid the possibility oI leaks. This is due to the smaller molecular dimensions oI reIrig-
erant R404A.
To guarantee the maximum eIIiciency in controlling leaks, it is recommended to use a leak de-
tector designed Ior use with reIrigerant R404A, or as an alternative, a detector designed Ior use
with Helium.
Note: Do not make a mixture of R404A and air to control leaks in the system.
6.4.3.10 High pressure limit control
To protect the system, it may be necessary to install a high pressure limit switch to control the
maximum discharge pressure. The settings on this limit switch should be in accordance with the
limits established in Chapter 7.1.3 - Discharge gas maximum pressures.
(1) The soluble residual contents and solid residues must be less than 100mg/m
2
of system internal surface area. Of this,
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 57 - 98
6.4.4 Guide for the use of R407C
6.4.4.1 General information
ReIrigerant R407C can normally be us ed as a substitute Ior reIri gerant R22 i n applications Ior
air conditioning and medium and high temperature applications.
Table 27 R 407C Physical Characteristics
Table 28 R 407C Ecological Characteristics
6.4.4.2 System components compatibility
All reIrigeration system components should be compatible with the reIrigerant and lubricant
used in the compressor. Substances containing chlorine, mineral oils, paraffin and silicone are
not approved.
All equipment used in the reIrigerator manuIacturing process that require lubrication and may
come into contact with the reIrigeration system components, must use exclusively Polyolesther
oil as a lubricant (suggested viscosity 18 - 20 cSt 40 C).
Due to the strict requirements associated with the use oI the R404A particular attention must be
given to the internal cleanliness oI the system. The above-mentioned substances as well as any
solid residues (dust, metal particles, etc...) must not be introduced into the system.
It is recommended that the maximum level oI the contamination should be 50 less than what
is prescribed in norm DIN 8964
(1)
6.4.4.3 Expansion device
For a new app lication, the Iirst co mponent to be dimensioned should be t he capillary tube. To
prepare the prototype, use chapter 6.6 - CAPILLARY TUBES as a reIerence.
Generally to convert a system Irom R22 to R407C, the same capillary tube may be used.
For each system, the optimal dimensioning oI the capillary tube should be perIormed in an ap-
propriate test laboratory in order to obtain the best working conditions, and to avoid the return oI
liquid reIrigerant to the compressor.
Zeotropic Mixture - Three HFC components
R 134a (1112 tetraIluorethane)
52%
R 125 (pentaIluorethane)
25%
R 32 (diIluoromethane)
23%
Boiling Point Temperature 43.6 C (ReI.: R 12 29.8 C)
Glide ( evaporation temperature Ior the three components) 7.1 C
ODP (Ozone Depletion Potential) 0 (ReI.: R 22 0,05)
GWP (Global Warming Potential) 1610 (20 years) (ReI.: R 22 1700)
(1) The soluble residual contents and solid residues must be less than 100mg /m
2
of system internal surface area. Of this,
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 58 - 98
6.4.4.4 Evaporator and condenser
The operating pressures oI R407C are higher than those oI R22, and thereIore, require a larger
condenser than the systems using R22.
6.4.4.5 Filter dryer
It is recommended to use a Iilter dryer, such as XH7, that is compatible with the reIri gerant
R407C and the compressor oil. (reIer to chapter 6.5 - Filter Dryer).
The Iilter should have a molecular sieve oI no less than 3 Angstroms.
It is suggested to increase the mass oI the molecular dryer 15 20 compared to the one used
with reIrigerant R22.
Always consult the manuIacturer Ior the proper selection oI a Iilter dryer.
6.4.4.6 Evacuation and charging equipment
Generally the vacuum level Ior an R407C system is the same used Ior a system with R22.
Good reIrigeration practice suggests system evacuation Irom both low side and high side, achiev-
ing a minimum level oI 0.14 mbar (100 Hg) with a non-condensable value oI less than 0.3 by
volume.
Use charging equipment suitable Ior use oI the reIrigerant R407C, and iI possible, dedicate this
machine Ior use only with reIrigerant R407C.
6.4.4.7 Refrigerant charge
Generally the quant ity oI the reIrigeran t R134a introduced into the system can be reduced to
80-90 compared to the required charge oI R22.
For each system, the optimalreIrigerant charge should be accurately deIined (reduced to the min-
imum necessary) only aIter execut ing appropriate laboratory tests have been perIormed on the
system. This must be done in order to obtain the best working conditions and to avoid the return
oI liquid reIrigerant to the compressor during running and the migration oI gas during the oII-
cycle.
ReIrigerant R407C should not have any contamination. Even a small amount oI a Chlorine-based
reIrigerant can cause problems.
ReIrigerant R407C, a zeotropic mixture, must be charged into the system only in the liquid phase
to guarantee that the composition oI the reIrigerant remains constant.
6.4.4.8 Moisture
In order to avoid problems that can shorten liIe oI the reIrigeration system, use components that
are i nternally dry and p roperly sealed t o prevent t he ent rance oI moisture. These components
should remain sealed until they are used.
It is recommended to avoid leaving the compressor and components exposed to the ambient Ior
more than 15min.
II there are doubts about the presence oI moisture in a component, it may be dried by blowing
dry air (with a dew point below -40 C) through the internal surIace Ior a suIIicient time period.
It is recommended to maintain moisture content in the system 50 lower than it is prescribed by
norm DIN 8964
(1)
.
(1) The soluble residual contents and solid residues must be less than 100mg/m
2
of system internal surface area. Of this
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 59 - 98
The level oI moisture present in the reIrigeration circuit should be below 40ppm. AIter the sys-
tem has been operating, the Iilter dryer should remove moisture Irom the system Irom a level be-
low 20ppm.
6.4.4.9 Leak control
It is recommended that special attention be given to the correct welding oI the system compo-
nents to avoid the possibility oI leaks. This is due to the smaller molecular dimensions oI reIrig-
erant R407C.
To guarantee the maximum eIIiciency in controlling leaks, it is recommended to use a leak de-
tector designed Ior use with reIrigerant R407C - R134a, or as an alternative, a detector designed
Ior use with Helium.
Note: Do not use a mixture of R407C and air to control leaks in the system.
6.4.4.10 High pressure limit control
To protect the system, it may be necessary to install a high pressure limit switch to control the
maximum discharge pressure. The settings on this limit switch should be in accordance with the
limits established in Chapter 7.1.3 - Discharge gas maximum pressures.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 60 - 98
6.4.5 Guide for the use of R290
6.4.5.1 General information
The refrigerant R290 (propane) is used to substitute R22, as well as R404A, for low and medium
back pressure applications, and air conditioning.
Before supplying compressors for use with R290, it is first necessary to perform an evaluation
of the risks involved with the use of this refrigerant. The customer should perform a risk assess-
ment to ensure proper knowledge about the handling and use of the R290 in the refrigerant sys-
tem (for further information please contact the Technical Assistant Department at Embraco
Europe).
Refrigerant R290 can normally be used in the same compressor designed for use with R22, but
with a different (hermetic type) thermal overload protector.
Tabella 29 R290 Physical Characteristics
Table 30 R290 Ecological Characteristics
PLEASE NOTE: R290 is flammable and should then be handled by qualified personnel in accordance
with the rules and regulations now established for safe use.
6.4.5.2 System component compatibility
All of the components in the refrigeration system that may contain contaminants should conform
to the requirements outlined in norm DIN 8964
(1)
.
The presence of the contaminants paraffin and silicon is not permitted.
6.4.5.3 Expansion device
For a new application the first component to be dimensioned should be the capillary tube. To pre-
pare the prototype, use chapter 6.6 - CAPILLARY TUBES as a reference.
Generally, when changing a system from R22 to R290, the same capillary tube can be used al-
though the length should be decreased by approximately 5%.
It is not recommended to use a capillary tube with an internal diameter less than 0.6 mm.
For each system the optimal dimensioning of the capillary tube should be performed in an appro-
priate test laboratory, in order to obtain the best working conditions.
6.4.5.4 Evaporator and condenser
Generally to convert a system from R22 to R290, the same evaporator and condenser may be used.
Molecular Weight 44.1 kg / kmole (Ref.: R 22 = 86.5)
Critical Temperature 96.8 C (Ref.: R 22 = 96.1 C)
Critical Pressure 42.5 bar (Ref.: R 22 = 49.8 bar)
Boiling Point -42.1 C (Ref.: R 22 = -40.8 C)
Flammability in Air
Minimum limit. LEL = 2.1% in vol.;
Maximum limit UEL = 9.5% in vol.
ODP (Ozone Depletion Potential) 0 (Ref.: R 22 = 0.05)
GWP (Global Warming Potential) 3 (100 years) (Ref.: R 22 = 1700)
(1) The soluble residual contents and solid residues must be less than 100mg /m
2
of system internal surface area. Of this, a
maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/soluble
and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 61 - 98
6.4.5.5 Filter dryer
Refrigerant R290 requires the use of a normal filter drier type XH-9 (See Chapter
Dryer)
6.5 - Filter
Always consult the manufacturer for the proper selection of the filter drier.
6.4.5.6 Evacuation and charging equipment
Generally the vacuum level for an R290 system is the same used for a system with R22.
Good refrigeration practice suggests system evacuation from both low side and high side, achiev-
ing a minimum level of 0.14 mbar (100 Hg) with a non-condensable value of less than 0.3% by
volume.
Use charging equipment suitable for use of the refrigerant R290, and if possible, dedicate this
equipment for use only with this refrigerant.
6.4.5.7 Refrigerant charge
Generally the quantity of the refrigerant R600a introduced into the system can be reduced from
50% 60% compared to the required charge of R22.
This characteristic greatly reduces the legal risk of flammability of the refrigerant in case of a
system leak.
For each system the optimal refrigerant charge should be determined in an appropriate test lab-
oratory in order to obtain the best working conditions.
6.4.5.8 Moisture
In order to avoid problems that can shorten life of the refrigeration system, use components that
are supplied internally dried and properly sealed to prevent the entrance of moisture. These com-
ponents should remain sealed until they are used.
The moisture content in a system should conform to norm DIN 8964
(1)
.
The level of moisture present in the refrigeration circuit should be below 40ppm and after the
system has been operating, the filter dryer should remove moisture from the system from a level
below 20ppm.
6.4.5.9 Leak control
It is recommended that special attention be given to the correct welding, or other forms of union
of the system components, to avoid the possibility of leaks.
To guarantee the maximum efficiency in controlling leaks, it is recommended to use a leak de-
tector designed for use with refrigerant R290, or as an alternative, a detector designed for use
with Helium.
6.4.5.10 High pressure limit control
To protect the system, it may be necessary to install a high pressure limit switch to control the
maximum discharge pressure. The settings on this limit switch should be in accordance with the
limits established in Chapter 7.1.3 - Discharge gas maximum pressures.
(1) The soluble residual contents and solid residues must be less than 100mg/m
2
of system internal surface area. Of this
a maximum of 40 mg/m
2
can be soluble and the maximum of 60mg /m
2
can be insoluble (for the definitions of solid/
soluble and additional details refer to the norm mentioned above).
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 62 - 98
6.5 FILTER DRYER
The filter drier must be chosen with the molecular sieve suitable to the refrigerant type used in
the system as indicated in the Table 31.
Table 31 Suggested Filter Dryer
For the applications with R134a - R404A, we suggest to increase the weight of the molecular
sieve by 10% 15% compared to the corresponding applications with R12 - R502. The filter dri-
er must be properly protected from absorption of ambient humidity during assembly of the sys-
tem according to the following practices:
Remove the protection caps from the filter shortly before welding.
The filters supplied without protection caps, in blister or in hermetic boxes must be duly
protected to avoid moisture absorption before welding.
A reduced absorption capacity can cause an incomplete water absorption by the molecular
sieve, therefore, the moisture could circulate freely in the system with the following effects
indicated in Table 32.
Table 32 Inconvenient caused by moisture in the system
REFRIGERANT MOLECULAR SIEVE
8 ( 5 - H X - A 4 a 0 0 6 R - 2 1 R = 12)
R 22 - R 502 (R 12 - R 600a) 4A-XH-6 (8 = 12)
R 134a (R 12 - R 600a - R 407C) XH-7 (8 x 12)
R 404A - R 402A- R 402B - R 401A - R 401B -
R 507 - R 290
(R 12 - R 600a - R 134a - R 22 - R 502 - R 407C)
XH-9 (8 = 12)
1 Ice build-up:
Reduces the cross-sectional area of the capillary tube, or expansion
valve, up to their complete obstruction.
2 Acid build-up:
Causes serious problems in the compressor and to the molecular sieve of
the filter. Typical marks and consequences are:
Copper plating of valve plate, valve reeds, crankshaft bearings, etc.
Etching of electric motor insulation by acids, with burning of motor
windings.
Destruction of the filter with disintegration of molecular sieve and
build-up of dusts.
Wears and blocks alternative and rotating mechanical parts.
3 Oil
contamination:
Causes acidification and reduction of its lubricating power, with change
of oil color (brown). It can cause build-up of sludge, with subsequent
poor lubrication of compressor.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 63 - 98
6.6 CAPILLARY TUBES
During the initial steps of the design of a new cabinet Table 33 can provide a helpful guidance
for selecting the most appropriate capillary tube dimensions to start with. The exact size of the
capillary must however be found according to the results of the laboratory tests performed on the
prototype cabinets.
The values, indicated on Table 33, have been determined according to the following considera-
tions:
LBP-MBP-HBP Applications: with heat exchanger of minimum length 0.9 m and with 0
C sub-cooling.
Air Conditioning Applications: with condensing temperature of 54 C, sub-cooling of 8 C,
return gas temperature 18 C.
Table 33 Choice of Capillary
R 600a - LBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 30C to 15C
evap. temp.)
(from 15C to 5C
evap. temp.)
EMU26CLC 50 Hz 0.66 mm I.D. = 4.00 m 0.66 mm I.D. = 3.45 m
EMT26CLP 50 Hz 0.66 mm I.D. = 3.80 m 0.66 mm I.D. = 3.30 m
EMU32CLC 50 Hz 0.66 mm I.D. = 3.60 m 0.78 mm I.D. = 3.60 m
EMT32CLP 50 Hz 0.78 mm I.D. = 3.60 m 0.91 mm I.D. = 3.60 m
EMT40CLP-EMU40CLC 50 Hz 0.78 mm I.D. = 3.50 m 0.91 mm I.D. = 3.50 m
NBM1112Y - NBT1112Y
NBU1112Y
EMT45CLP - EMU46CLC
50 Hz 0.78 mm I.D. = 3.40 m 0.91 mm I.D. = 3.40 m
NBM1114Y NBU1114Y
NBT1114Y EMT56CLP
50 Hz 0.78 mm I.D. = 3.20m 0.91 mm I.D. =
3.20 m
NBK1116Y NBU1116Y
NBT1116Y
50 Hz 0.78 mm I.D. = 3.00 m 0.91 mm I.D. = 3.00 m
NBK1118Y NBU1118Y
NBT1118Y
50 Hz 0.91 mm I.D. = 3.60 m 1.06 mm I.D. = 3.60 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 64 - 98
R22 - LBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 30C to 5C
evap. temp.)
NE2125E
50 Hz 0.91 mm I.D. = 3.2 m
60 Hz 0.91 mm I.D. = 2.85 m
NE2134E
50 Hz 0.91 mm I.D. = 2.8 m
60 Hz 0.91 mm I.D. = 2.5 m
T2140E
50 Hz 0.91 mm I.D. = 2.6 m
60 Hz 0.91 mm I.D. = 2.3 m
T2155E
50 Hz 1.20 mm I.D. = 3.9 m
60 Hz 1.20 mm I.D. = 3.5 m
T2168E
50 Hz 1.20 mm I.D. = 3.3 m
60 Hz 1.20 mm I.D. = 2.8 m
NJ2178E 50 Hz 1.20 mm I.D. = 3.0 m
NJ2190E 50 Hz 1.20 mm I.D. = 2.5 m
R22 - MBP/HBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 20C to 5C
evap. temp.)
(from 5C to +10C
evap. temp.)
NB6144E
50 Hz 1.06 mm I.D. = 3.5 m 1.06 mm I.D. = 3.0 m
60 Hz 1.06 mm I.D. = 3.0 m 1.06 mm I.D. = 2.6 m
NB6152E
50 Hz 1.06 mm I.D. = 3.3 m 1.06 mm I.D. = 2.7 m
60 Hz 1.06 mm I.D. = 2.8 m 1.06 mm I.D. = 2.3 m
NB5165E - NB6152E
50 Hz 1.06 mm I.D. = 3.0 m 1.20 mm I.D. = 3.5 m
60 Hz 1.06 mm I.D. = 2.6 m 1.20 mm I.D. = 3.0 m
NE5181E - NE6181E
50 Hz 1.20 mm I.D. = 3.2 m 1.20 mm I.D. = 2.5 m
60 Hz 1.20 mm I.D. = 2.75 m 1.20 mm I.D. = 2.2 m
NE5195E - NE6195E 60 Hz 1.20 mm I.D. = 3.0 m 1.27 mm I.D. = 2.8 m
NE5195E - NE6210E
50 Hz 1.20 mm I.D. = 2.9 m 1.27 mm I.D. = 2.6 m
60 Hz 1.20 mm I.D. = 2.5 m 1.27 mm I.D. = 2.3 m
NE9213E - NE7213F
50 Hz 1.27 mm I.D. = 2.7 m 1.27 mm I.D. = 1.9 m
60 Hz 1.27 mm I.D. = 2.35 m 1.27 mm I.D. = 1.65 m
T6217E 50 Hz 1.27 mm I.D. = 2.3 m 1.27 mm I.D. = 1.6 m
T6220E 50 Hz 1.37 mm I.D. = 2.0 m 1.37 mm I.D. = 1.6 m
NJ9226E - NJ9226P - NJ7225F
50 Hz 1.63 mm I.D. = 2.9 m 1.63 mm I.D. = 1.7 m
60 Hz 1.63 mm I.D. = 2.5 m 1.90 mm I.D. = 1.9 m
NJ7228F - NJ7228P - NJ7228E
50 Hz 1.63 mm I.D. = 2.4 m 1.90 mm I.D. = 1.9 m
60 Hz 1.90 mm I.D. = 2.5 m 2.16 mm I.D. = 2.0 m
NJ9232E - NJ9232P - NJ7231F
NJ7231P
50 Hz 1.90 mm I.D. = 2.8 m 2.16 mm I.D. = 2.2 m
60 Hz 1.90 mm I.D. = 2.15 m 2.16 mm I.D. = 1.7 m
NJ9238E - NJ9238P
NJ7238E - NJ7238P
50 Hz 2.16 mm I.D. = 2.6 m 2 = 1.63 mm I.D. = 1.8 m
60 Hz 2.16 mm I.D. = 2.0 m 2 = 2.16 mm I.D. = 2.5 m
NJ7240F - NJ7240P
50 Hz 2.16 mm I.D. = 2.3 m 2 = 2.16 mm I.D. = 2.8 m
60 Hz 2 = 1.63 mm I.D. = 2.0 m 2 = 2.16 mm I.D. = 2.3 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 65 - 98
R 22 - Air Conditioning Applications
COMPRESSOR FREQUENCY DIMENSION
NE7213E
50 Hz 1.24 mm I.D. = 1.05 m
60 Hz 1.24 mm I.D. = 1.0 m
NE7215E
50 Hz 1.24 mm I.D. = 1.0 m
60 Hz 1.24 mm I.D. = 0.95 m
T7220E - T7220F
50 Hz 1.37 mm I.D. = 1.0 m
60 Hz 1.37 mm I.D. = 0.95 m
T7223E - T7223F
50 Hz 1.5 mm I.D. = 1.05 m
60 Hz 1.5 mm I.D. = 1.0 m
NJ7225E - NJ7225F
50 Hz 2.16 mm I.D. = 2.0 m
60 Hz 2.16 mm I.D. = 1.8 m
NJ7228E - NJ7228F
50 Hz 2.16 mm I.D. = 1.9 m
60 Hz 2.16 mm I.D. = 1.7 m
NJ7231E - NJ7231F -NJ7231P
50 Hz 2.16 mm I.D. = 1.6 m
60 Hz 2.16 mm I.D. = 1.4 m
NJ7238E - NJ7238P
50 Hz 2 = 2.16 mm I.D. = 2.5 m
60 Hz 2 = 2.16 mm I.D. = 2.3 m
NJ7240E - NJ7240F - NJ7240P
50 Hz 2 = 2.16 mm =I.D. = 2.3 m
60 Hz 2 = 2.16 mm I.D. = 2.1 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 66 - 98
R134a - LBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 30C to 15C
evap. temp.)
(from 15C to 5C
evap. temp.)
EMT22H 50 Hz 0.61 mm I.D. = 4.0 m 0.61 mm I.D. = 3.5 m
EMT36H 50 Hz 0.78 mm I.D. = 4.0 m 0.91 mm I.D. = 4.0 m
EMT43H 50 Hz 0.78 mm I.D. = 3.7 m 0.91 mm I.D. = 3.7 m
EMT49H 50 Hz 0.78 mm I.D. = 3.5 m 0.91 mm I.D. = 3.5 m
NB2116Z -
NB1116Z - EMT60H
50 Hz 0.78 mm I.D. = 3.3 m 0.91 mm I.D. = 3.3 m
60 Hz 0.78 mm I.D. = 2.75 m 0.91 mm I.D. = 2.75 m
NB 1118Z -
NB2118Z
50 Hz 0.91 mm I.D. = 4.0 m 1.06 mm I.D. = 4.0 m
60 Hz 0.91 mm I.D. = 3.3 m 1.06 mm I.D. = 3.3 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 67 - 98
R134a - HBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 15C to 5C
evap. temp.)
(from 5C to +10C
evap. temp.)
NB5125Z
50 Hz 0.78 mm I.D. = 2.5 m 0.91 mm I.D. = 2.4 m
60 Hz 0.78 mm I.D. = 2.1 m 0.91 mm I.D. = 2.0 m
NB5128Z
50 Hz 0.78 mm I.D. = 2.4 m 0.91 mm I.D. = 2.3 m
60 Hz 0.78 mm I.D. = 2.0 m 0.91 mm I.D. = 1.9 m
NB5132Z - NB6132Z
50 Hz 0.78 mm I.D. = 2.3 m 0.91 mm I.D. = 2.2 m
60 Hz 0.78 mm I.D. = 1.9 m 0.91 mm I.D. = 1.8 m
NB5144Z - NB6144Z
NEK5144Z - EMT6144Z
50 Hz 0.91 mm I.D. = 2.9 m 1.06 mm I.D. = 2.7 m
60 Hz 0.91 mm I.D. = 2.4 m 1.06 mm I.D. = 2.3 m
NE5160Z - NE6160Z
NEK6160Z - EMT6160Z
50 Hz 0.91 mm I.D. = 2.4 m 1.06 mm I.D. = 2.5 m
60 Hz 0.91 mm I.D. = 2.1 m 1.06 mm I.D. = 2.2 m
NE5170Z - NE6170Z
EMT6170Z
NEK5170Z - NEK6170Z
50 Hz 1.06 mm I.D. = 3.2 m 1.27 mm I.D. = 3.3 m
60 Hz 1.06 mm I.D. = 2.65 m 1.27 mm I.D. = 2.75 m
NE5187Z - NE6187Z
NEK6187Z
50 Hz 1.24 mm I.D. = 4.0 m 1.37 mm I.D. = 3.3 m
60 Hz 1.24 mm I.D. = 3.4 m 1.37 mm I.D. = 2.9 m
NE6210Z - NEK6210Z 60 Hz 1.37 mm I.D. = 3.5 m 1.50 mm I.D. = 3.3 m
NEK6212Z 60 Hz 1.37 mm I.D. = 3.3 m 1.50 mm I.D. = 3.1 m
T6213Z
50 Hz 1.37 mm I.D. = 3.5 m 1.50 mm I.D. = 3.3 m
60 Hz 1.37 mm I.D. = 3.1 m 1.50 mm I.D. = 2.9 m
T6215Z - T6217Z
50 Hz 1.37 mm I.D. = 3.1 m 1.50 mm I.D. = 2.9 m
60 Hz 1.37 mm I.D. = 2.7 m 1.50 mm I.D. = 2.5 m
NJ6220Z - NJ6220ZX
50 Hz 1.63 mm I.D. = 3.6 m 1.78 mm I.D. = 3.3 m
60 Hz 1.63 mm I.D. = 3.0 m 1.78 mm I.D. = 2.75 m
NJ6226Z - NJ6226ZX
50 Hz 2 = 1.50 mm I.D. = 4.0 m 2 = 1.63 mm I.D. = 3.0 m
60 Hz 2 = 1.50 mm I.D. = 3.4 m 2 = 1.63 mm I.D. = 2.5 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01E+ 2000-04 0 20-02 68 - 98
R 290 - R 404A - R 507 - LBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 40C to 10C
evap. temp.)
NEK2121U - NEK2125U
EMT2121U - EMT2125U
NE2125GK - NEK2125GK
EMT2125GK - EMT2125GK
50 Hz 0.91 mm I.D. = 4.0 m -
60 Hz 0.91 mm I.D. = 3.5 m -
NEK2130GK - NEK2134GK
NE2134GK - NEK2134U
50 Hz 0.91 mm I.D. = 3.0 m -
60 Hz 0.91 mm I.D. = 2.65 m -
T2140GK - NEK2150U
50 Hz 0.91 mm I.D. = 2.7 m -
60 Hz 0.91 mm I.D. = 2.4 m -
T2155GK
50 Hz 1.20 mm I.D. = 4.1 m -
60 Hz 1.20 mm I.D. = 3.6 m -
T2168GK - NT2168GK
50 Hz 1.20 mm I.D. = 3.4 m -
60 Hz 1.20 mm I.D. = 3.0 m -
T2178GK
NT2178GK - NT2160U
NT2180GK - NT2170U
50 Hz 1.20 mm I.D. = 3.1 m -
60 Hz 1.20 mm I.D. = 2.75 m -
T2180GK 50 Hz 1.20 mm I.D. = 2.9 m -
60 Hz 1.20 mm I.D. = 2.55 m -
NJ2192GK - NJ2192GS
NT2192GK - N2180U
50 Hz 1.40 mm I.D. = 3.5 m -
60 Hz 1.40 mm I.D. = 3.1 m -
NJ2212GK - NJ2212GS
50 Hz 1.60 mm I.D. = 3.5 m -
60 Hz 1.60 mm I.D. = 3.1 m -
NJ2212GK - NJ2212GS
NT2212GK
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 69 - 98
R 290 - R 404A - R 507 - MBP Applications
COMPRESSOR FREQUENCY
DIMENSION
(from 20C to 5C
evap. temp.)
(from 5C to +15C
evap. temp.)
NB6144GK - NEK6144GK
EMT6144U - EMT6144GK
50 Hz 1.06 mm I.D. = 3.30 m 1.06 mm I.D. = 2.80 m
60 Hz 1.06 mm I.D. = 2.80 m 1.06 mm I.D. = 2.45 m
NB6152GK - NEK6152U
EMT6152U - EMT6152GK
50 Hz 1.06 mm I.D. = 3.10 m 1.06 mm I.D. = 2.55 m
60 Hz 1.06 mm I.D. = 2.65 m 1.06 mm I.D. = 2.15 m
NB5165GK
EMT6165U - EMT6165GK
NB6165GK - NEK6165GK
50 Hz 1.06 mm I.D. = 2.80 m 1.20 mm I.D. = 3.30 m
60 Hz 1.06 mm I.D. = 2.45 m 1.20 mm I.D. = 2.85 m
NE5181GK - NEK6181U
NE6181GK - NEK 6181GK
50 Hz 1.20 mm I.D. = 3.00 m 1.20 mm I.D. = 2.35 m
60 Hz 1.20 mm I.D. = 2.60 m 1.20 mm I.D. = 2.05 m
NE5195GK
NE6195GK
60 Hz 1.20 mm I.D. = 2.80 m 1.27 mm I.D. = 2.65 m
NEK 6210U
NE6210GK - NEK6210GK
50 Hz 1.20 mm I.D. = 2.75 m 1.27 mm I.D. = 2.45 m
60 Hz 1.20 mm I.D. = 2.35 m 1.27 mm I.D. = 2.15 m
NEK6213U - NEK6213GK
NE9213GK
50 Hz 1.27 mm I.D. = 2.55 m 1.27 mm I.D. = 1.80 m
60 Hz 1.27 mm I.D. = 2.20 m 1.27 mm I.D. = 1.55 m
T6217GK
NT6217U - NT6217GK
50 Hz 1.27 mm I.D. = 2.15 m 1.27 mm I.D. = 1.50 m
60 Hz 1.27 mm I.D. = 1.85 m 1.37 mm I.D. = 1.60 m
T6220GK
50 Hz 1.37 mm I.D. = 1.90 m 1.37 mm I.D. = 1.50 m
60 Hz 1.37 mm I.D. = 1.65 m 1.63 mm I.D. = 1.75 m
T6222GK
NT6220U - NT6220GK
NT6222U - NT6222GK
50 Hz 1.37 mm I.D. = 1.60 m 1.63 mm I.D. = 1.70 m
60 Hz 1.63 mm I.D. = 2.85 m 1.63 mm I.D. = 1.55 m
NJ9226GK
NT6224U - NT6226GK
50 Hz 1.63 mm I.D. = 2.75 m 1.63 mm I.D. = 1.60 m
60 Hz 1.63 mm I.D. = 2.35 m 1.90 mm I.D. = 1.80 m
NJ9232GK
50 Hz 1.90 mm I.D. = 2.65 m 2.16 mm I.D. = 2.05 m
60 Hz 1.90 mm I.D. = 2.00 m 2.16 mm I.D. = 1.60 m
NJ9238GK
50 Hz 2.16 mm I.D. = 2.45 m 2=1.63 mm I.D. = 1.70 m
60 Hz 2.16 mm I.D. = 1.90 m 2=2.16 mm I.D. = 2.35 m
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 70 - 98
6.7 APPLICATION OF RUBBER GROMMETS
Alternating Iorces oI Iirst order, such as rotating masses and masses having rectilinear and alter-
nating motion, are duly balanced inside the compressor. Inertial alternating Iorces oI greater or-
der are not balanced, however, they are partially absorbed by the internal suspension springs and
partially by the rubber grommets, when correctly applied to the external mounting base. The rub-
ber grommets and the sleeves, have been selected in order to guarantee the Iollowing character-
istics:
Reduction oI vibrations transmission oI more than 50.
Absorption oI inertial, tangential Iorces and relative moments, particularly noticeable at com-
pressor, start and stop.
The components oI this external suspension system are supplied partly by Embraco Europe (rub-
ber grommets and sleeves) while the remaining components Ior their blocking screws, washers
and nuts (or suitable alternate systems), must be Iurnished by the customer. It is very important
that these components be assemb led correctly in order to guarantee, as in dicated in Figure 30,
the proper clearance between the rubber grommet and Ilat washer, Iixed between nut and sleeve.
This clearance allows the improved damping oI the vibrations transmitted by the compress or,
isolating it Irom base plate. For each compressor series, a rubber grommet has been deIined to
be coupled to the relative sleeve as indicated in Table 34.
Legend 6 Rubber Grommets Assembling Process
Figure 30 Rubber Grommets Assembling Process
PLEASE NOTE: The use of grommets and sleeves different from the ones designated may decrease
the absorption of vibration resulting in a subsequent noise increase.
A Washer F Mounting Base
B Gap G Clip
C Sleeve H Screw M6 (M8)
D Grommets I Pin
E Base plate
Correct Mounting of Rubber Grommets
by means of Nut and Bolt by means of Stud and Clamp
Incorrect Mounting of Rubber Grommets
A
B
C
D
H
E
F
A
I
F
E
D
G
A
C
D
H
E
F
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 71 - 98
Table 34 Rubber Grommets
Figure 31 Rubber Grommets
COD. A B C D E F G H L M N P Q R S T
AM01 17.2 9 6.6 16.7 5 3 10.5 3 20.8 16 10.5 8.5 19 25
AM02 16.6 11.1 8.7 16.7 10.5 3 23.8 17.5 11.1 28.6
AM03 18.3 11.1 8.7 17.5 4.7 9.5 4 23.8 19 11.1 17.5 31.8
AM04 17.2 9 6.6 16.7 11 3 10.5 3 23.8 16 11 8.5 22 28.6
AM05 23 11.1 8.7 23 9.4 3.2 3.2 15 4 23.8 19 14.3 11.1 19 25.3 31.7
SERIES GROMMETS AND SLEEVES
1 1 0 . 1 2 2 . 2 1 0 M A 2.222.018
EM
1 0 0 . 1 2 2 . 2 2 0 M A 2.222.014
NE
(not standard)
(will substitute
version AM04)
Q
S
T
N
P
M
L
F
E
D
H
A
C
B
P
T
N
M
L
D
H
A
C
B
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 72 - 98
SERIES GROMMETS AND SLEEVES
3 0 0 . 1 2 2 . 2 3 0 M A 2.222.015
NB
NE
Only for models
with Universal
baseplate
9 0 0 . 1 2 2 . 2 4 0 M A 2.222.018
NB
NE
All models
with European
baseplate
4 0 0 . 1 2 2 . 2 5 0 M A 2.222.016
T - NT
NJ
R
T
N
M
L
G
D
H
P
A
C
B
Q
T
R
N
M
L
G
E
D
H
P
A
C
B
Q
T
S
R
N
M
L
G
E
F
D
H
P
A
C
B
(will be
substituted by
version AM01)
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 73 - 98
6.8 WELDING OF CONNECTION TUBES
During brazing oI the connectors on the compressor's copper tubes, the Iollowing instructions
must be observed:
DO NOT ALLOW the Ilame Irom the torch to reach the housing during the welding oI the
compressor tube in order to avoid overheating, damages to welding, and oil carbonization on
the compressor's internal walls.
DO NOT ALLOW the Ilame Irom the torch to approach the 'hermetic terminal in order to
avoid the cracking oI the glass insulating material oI the three pins and subsequent gas leaks.
The welding oI the connections on copper tubes can be done with welding material with low sil-
ver contents, or, exclusively Ior 'copper/copper connections. It can be advantageous to use the
'phosphorous copper.
Proper welding is characterized by a good penetration oI weld material, to guarantee a good me-
chanical resistance, and a lack oI leaks Irom the connection.
These characteristics are obtained with the use oI suitable materials and a perIectly perIormed
welding, as well as with a correct sizing oI the tubes to be coupled in order to guarantee the op-
timum clearance. 'Tight clearance determines a bad penetration oI weld material, while 'large
clearance causes penetration oI weld material and de-oxidizers inside the tube and compressor.
To limit the internal contamination by the de-oxidizing Ilux, we suggest applying small quanti-
ties oI de-oxidizer on the connection tube aIter connecting it to the compressor tube.
During the welding operation, avoid overheating oI the connection. This reduces the Iormation
oI oxide contaminants inside oI the tubes. It is suggested, during the welding operation, to blow
nitrogen through the tubes, particularly Ior R404A applications.
With the use oI R13 4a, the possibility oI reIr igerant gas leak s through deIective welds i s in-
creased due to the smaller size oI the molecule oI R134a.
We also suggest taking particular care in perIorming the welding and leak detection, which must
be carried out with equipment sensitive to the reIrigerant type used.
6.9 ROTALOCK VALVES
For J series compressors, a special version can be supplied only upon the Customer's request.
This conIiguration has, in place oI the suction tube, a threaded union welded on the cover oI the
housing, suitable Ior Iixing a Rotalock suction valve.
A cap screwed on the union guarantees its protection and the internal pressurization oI the com-
pressor. This special version can be supplied in two ways:
Compressor with union Ior valve but with no Rotalock valve supplied.
Compressor with union Ior valve, unassembled Rotalock valve, and equipped with the appro-
priate sealing gasket.
The threading oI the uni on oI 1" - 14 NS-2 accepts Rotalock valves wit h diIIerent dimensions
according to the compressor type, as indicated on the Compressor Catalog. The assembly oI the
valve on the compressor union must be done by inserting the gasket on its seat on the union, aIter
dampening both with a light oil Iilm (oI the same type charged into the compressor). The valve
nut should be tightened to the torque indicated on the Iollowing table. The valve can be oriented,
as necessary, within 360. II necessary it can be easily replaced using a new gasket seal.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 74 - 98
In the Iollowing table, indicated are the suggested tightening torques:
Table 35 Suggested tightening torques
For the valves with sweat connections, in order to avoid overheating during welding, which can
damage the gasket, we suggest to eIIect the welding beIore applying the gasket, and to connect
the valve to the compressor.
Legend 7 Rotalock Valve
Figure 32 Rotalock Valve
ELEMENT DIMENSION
TIGHTENING TORQUE
Nm Kgm
Stem opening/closing
(1)
Valve 1/2" SAE 9.311.3 0.95 1.15
Valve 5/8" SAE 11.313.7 1.15 1.40
Fixing nut orientation Valve 1/2" SAE 6782 6.85 8.35
Valve 5/8" SAE 6782 6.85 8.35
Service nut 1/4" Valve 1/4" SAE 10.816.3 1.10 1.66
(1) The opening and closing of the valve stem can be effected with electric or pneumatic drivers having a speed lower than 360 rpm.
Higher speed damages the stem and valve body tightness seats.
It is a good rule to try to keep the welding time to a minimum in order to not overheat the stem tight-
ness, even if produced with material resistant to high temperatures.
1 Attachment Ior service or Ior a manometer A & B Service caps (hexagonal nuts)
2 Connection to the receiver or to the compressor
3 Main port
4 Connections Ior pressure-stat
Mechanical connection aID001f Soldered connection aID001s
2
3
4
B
A
1
2
3
4
B
A
1
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 75 - 98
Figure 33 Valve Position
6.10 COMPRESSOR COOLING
Throughout the Embraco Europe compressor range, there are compressors with diIIerent cooling
requirements:
The static cooling (without Ian cooler) compressor requires that the compressor is positioned
in the appl ication in order to be co oled directly by an air current at ambient temperature,
through suIIicient openings placed in the application body.
The fan cooling compressor requires the use oI a Ian cooler (normally inlet type) positioned
in such a way that the Ilow is introduced to the compressor sideways (on the longer side op-
posite to that where it is placed the thermal protector).
The thermal protector, iI cooled by the air Ilow, may not trip, and may not protect the compressor
properly.
We suggest to maintain a distance oI 0.2 0.3 m Irom compressor Ian blades.
The Ian cooler can be chosen according to the air Ilow indicated in Table 36:
Table 36 Fan Coolers Characteristics
With raised stem - service port
closed aID002f
With the stem in the middle
position - all ports open aID003f
With the stem completely at the
bottom - main port closed aID004f
COMPRESSOR SERIES NB %-NE-T-.4 .J
FREE AIR FLOW (m
3
/h) 270 520 800
4
3
4
3
1
4
1
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 76 - 98
6.11 VACUUM OPERATIONS
It is fundamental to perform a proper evacuation of the refrigeration system to ensure proper run-
ning of the refrigerating machine, and to preserve the life of the compressor. A proper evacua-
tion process assures that the air and moisture contents are below the allowed limits.
The introduction of new refrigerants require the use of new polyester oils with characteristics of
high hygroscopicity which require the greatest care in system evacuation. There are various
methods to evacuate a refrigeration system: one-side (low pressure side), two-side (low and high
pressure sides), at different times, with phases of refrigerant pre-charge, etc. We must aim to
reach a vacuum value (measured at its stabilization on both the low and high pressure sides), bet-
ter than 0.14 mbar (100 Hg), and the maximum level of non-condensable must not exceed
0.3%.
6.12 REFRIGERANT CHARGE
After the vacuum operation, the system must be charged with the refrigerant type indicated on
the compressor nameplate or one of the alternate allowed types, in the pre-determined quantity.
For a correct charge we suggest, after carrying out the vacuum, to pump part of the refrigerant
into the compressor to break the vacuum; then start the compressor to draw the remaining part
of the charge.
In the small refrigerating systems utilizing few grams of charge, the refrigerant is usually
pumped into the compressor through the service tube. In this case you must wait 5 to 10 minutes
(time depending on the refrigerant quantity and on the ambient temperature), before starting the
compressor. This to allow partial refrigerant evaporation and to avoid the suction of liquid refrig-
erant into the compressor cylinder.
Table 37 Maximum Refrigerant Charge
In case the refrigerant charge should exceed the max values allowed for the compressor, take care
that the circuit is equipped with liquid receiver, and, for larger systems, an oil heater in the com-
pressor housing to avoid mixing of refrigerant in the oil, foaming with subsequent liquid suction
and pumping. If it becomes necessary for a technician to recharge the system in the field, he
should first remove all of the remaining original charge, and then recharge the system in accord-
ance with the refrigerant quantity indicated on the data plate.
PLEASE NOTE: To avoid irreparable damages to the compressor, never start it under vacuum (without
refrigerant charge).
PLEASE NOTE: The refrigerant mixtures must be charged in the system exclusively at liquid state.
SERIES EM - NE T NJ - NT
REFRGERANT
CHARGE (g)
350 500 800
PLEASE NOTE: The use of the compressor outside the intended working range cannot make use of the
warranty.
COMPRESSORS
HANDBOOK
Chapter
INFORMATION ABOUT CORRECT COMPRESSOR INSTALLATION
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 77 - 98
6.13 REFRIGERANT LEAKS CONTROL
A reIrigeration system can work normally Ior the entire liIe oI the compressor, only iI attention
is given to the proper installation. One oI the most important aspects is the absence oI reIrigerant
leaks.
We estimate that a 10 leak oI the reIrigerant charge over 15 years oI running the compressor;
will still allow Ior proper running oI the reIrigerating system.
With the new reIrigerants (R134a and mixtures), the possibility oI reIrigerant leaks through im-
proper welding increase due to th e reduced molecular size oI the reIrigerants. This adds to the
increase in the percentage oI leaks, due to the reduced charge compared to traditional reIriger-
ants. For above reasons, it is essential that accurate controls oI leaks are perIormed on the welds
with methods and equipment suitable to the applied reIrigerant type.
For the leak test of R134a, use equipment designed exclusively for that refrigerant.
6.14 ELECTRIC SUPPLY
The compressor assembled in the reIrig eration system must be connected to a vol tage supply
within the limits indicated in Table 5 - Voltages & Frequencies on page 15. Due to voltage drops
on the supply circuit, the voltage must be that measured at the compressor hermetic terminal. On
the same table, indicated are the minimum starting voltages at which the compressor can start
without load. In paragraph 7.1 - COMPRESSOR RUNNING LIMITS - 7.1.6 - Start conditions
- are indicated, Ior compressor start, the limit values oI suction pressure, discharge pressure and
supply voltage.
The correct sizing oI the cables is important to guarantee low voltage drops on running and dur-
ing the phases oI compressor start, and it must be determined according to the locked rotor cur-
rent indicated on the 'Electric Components List. A subsequent protection Iuse can also be sized:
225 oI the compressor running current plus 100 oI current input oI all other electric mo-
tors employed.
For three-phase models, use remote control, so sized switches that each contactor can with-
stand the current input value oI compressor.
PLEASE NOTE: R404A-R402A-R402B refrigerants must not be mixed to the air during leak detection,
neither be used nor let in presence of high air concentrations above atmospheric pressure at high tempera-
tures.
PLEASE NOTE: The electrical wiring must be performed according to the laws and regulations in the
country in which the refrigeration system will operate.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 78 - 98
7 RUNNING DATA AND COMPRESSOR
CHECKING PROCEDURES
7.1 COMPRESSOR RUNNING LIMITS
The sizing oI the system components must be perIormed in a way that the limits oI the charac-
teristics indicated below are not exceeded. During operation in the Iield, the system can encoun-
ter some Iactors wo rsening t he wo rking conditions, such as g as leaks, red uction o I t he
eIIectiveness on the condenser due to clogging, etc. Because oI these Iactors, it is recommend to
size the system with a good margin oI saIety, to allow the system to operate within the prescribed
limits.
7.1.1 Maximum temperature of electric motor stator windings
130 C max, under normal running conditions.
The temperature measurement can be done while the compressor is running through compatible
equipment (Ior inst. SILYTESTER oI BIDDLE USA), or through the met hod oI ohmic resist-
ance measurement, by disconnecting the compressor supply.
This method requires the availability oI instruments Ior measuring the ohmic resistance (digital
Ohmmeter, Wheatstone's bridge) and the temperature.
a) Measure the ohmic resistance RI oI the main winding (run) between the pins oI the hermetic
terminal C 'common (above) and R 'run (below on the right) and oI the corresponding sta-
bilized reIerence temperature TI.
b) Measure the ohmic resistance Rc oI the main winding (run) with hot motor between the pins
C and R at the Tc temperature to calculate.
c) Calculate the Tc temperature with the Iollowing Iormula:
Where:
Legend 8
Tc Unknown temperature with hot motor
Tf Motor temperature measured at the stabilized reIerence temperature
Rc Measured ohmic resistance, corresponding to the Tc temperature
Rf Measured ohmic resistance, corresponding to the Tf temperature
Tc
Rc Rf ( )
Rf
------------------------ 234,5 Tf + ( ) Tf + =
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 79 - 98
7.1.2 Discharge gas maximum temperature
Maximum temperature indicated in Table 38, measured on discharge tube at a distance of
50mm from compressor housing, under continuous running conditions.
7.1.3 Discharge gas maximum pressures
Pressure max peak, under Pull-down, as indicated in Table 38.
Maximum pressures, under continuous running, as indicated in Table 38.
Table 38 Discharge gas maximum pressures
Make sure that at the maximum ambient temperature anticipated the compressor operates
within the operating field indicated in the following section.
7.1.4 Suction gas overheating
Maintain the suction gas temperature overheating as low as possible (min 5 C), taking care
that there is no return of liquid.
Length of heat exchanger from 0.9 m to 1.3 m.
Refrigerant
PULLDOWN
MAXIMUM PEAK
MAXIMUM VALUE
CONDITION
MAX. TEMP.
DISCHARGE
GAS
kg/cm
2
(rel.) kg/cm
2
(rel.) C
R22 23.2 22.8 20.7 20.3 125
R290 (Propane) 21.1 19.8 18.1 17.7 110
R134a 15.8 15.5 13.9 13.6 140
R600a (Isobutane) 7.7 7.5 6.7 6.6 110
R407C 24.2 23.8 21.4 21.0 140
R404A 27.7 27.2 24.7 24.2 140
R507 28.5 27.9 25.4 24.9 140
bar (rel.) bar (rel.)
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 80 - 98
7.1.5 Compressor operating fields
Within the minimum and maximum values typical for each model.
In the diagrams represented on the following pages, indicated are the limits of evaporating, con-
densing, ambient and return gas temperatures.
The compressor can operate within the limits of evaporating and condensing temperatures de-
fined by the outlined area bordered by a continuous line, at the indicated conditions of ambient
and return gas temperature.
Outside these operating fields, the system operates at high pressures and high temperatures, and
cause early defects in the compressor.
The compressor defects caused by applications operating outside the prescribed fields will not
be considered under warranty.
7.1.5.1 R22 Compressors operating field
The production of R22 compressors was required for the replacement of R12 - R502 refrigerants
and the choice has been obliged by the non availability at that moment of other suitable alterna-
tive gases.
For low and medium temperature R22 cabinets, compressors must be selected according to the
limits associated with this type of gas, that was developed for high evaporating temperatures,
thus characterized by restrictive limits.
7.1.5.2 R404A - R507 - R600a - R134a - R22 R290 compressors operating field
The working fields represented in this section are related to all model and series of compressors
that take the indicated refrigerant.
1 LBP: R134a R600a
2 LBP: R404A R507 R290
3 MBP: R404A R507 R290
4 HBP: R134a R600a R 22
5 LBP: R 22
6 AC
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 81 - 98
Legend 9
Tc Condensing Temperature k Ambient 32 C and return gas 20 C
Te Evaporating Temperature m Ambient 32 C and return gas 20 C
(for a transitory period)
1 - REFRIGERANT R134a - R600a - APPLICATION LBP 2 - REFRIGERANT R404A - R507 - R290 - APPLICATION LBP
3 - REFRIGERANT R404A - R507 - R290 - APPLICATION MBP 4 - REFRIGERANT R134a - R600a - R22 - APPLICATION HBP
3 - REFRIGERANT R22 - APPLICATION LBP 4 - APPLICATION AC
35
40
45
50
55
60
$C
$C
-35 -30 -25 -20 -15 -10 -5
Te
T
c
k
m
35
40
45
50
55
60
$C
$C
-45 -40 -35 -30 -25 -20 -15 -10
Te
T
c
k
m
35
40
45
50
55
60
$C
$C
-25 -20 -15 -10 -5 0 5 10
Te
T
c
k
m
m
35
40
45
50
55
60
$C
$C
-20 -15 -10 -5 0 5 10 15
Te
T
c
k
m
35
40
45
50
55
60
$C
$C
-40 -35 -30 -25 -20 -15 -10 -5
Te
T
c
k
m
35
40
45
50
55
60
$C
$C
-10 -5 0 5 10 15 20 25
Te
T
c
k
m
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 82 - 98
7.1.6 Start conditions
On Table 39, indicated are the pressure limits to start the compressor at nominal or higher
voltage than 90% of rated values. (Equal or higher than 85% of rated value for AC models).
For applications where the pressure and voltage are outside the indicated limits, compressor
start is not guaranteed.
Table 39 Pressure limit value
7.1.7 Oil cooler temperatures
Equal inlet and outlet gas temperatures or with a maximum difference of 3 C.
We suggest to connect the condenser to the oil cooler at 1/3 of its total length (the final 2/3
of condenser after oil cooler).
APPLICATION
TYPE
STARTING
TORQUE TYPE
REFRIGERANT
TYPE
GAUGE PRESSURE
SUCTION DISCHARGE
Kg/cm
2
Kg/cm
2
LBP
LST
R134a 5.1 5.0 5.1 5.0
R 600a 2.2 2.1 2.2 2.1
R 22 8.6 8.4 8.6 8.4
R404A 10.5 10.3 10.5 10.3
R507 10.9 10.7 10.9 10.7
R290 7.8 7.4 7.8 7.4
HST
R134a 1.0 1.0 12.2 11.9
R600a 0.1 0.1 5.8 5.7
R22 2.5 2.5 18.4 18.1
R404A 3.3 3.3 22.0 21.5
R507 3.5 3.4 22.6 22.2
R290 2.4 2.4 16.1 15.8
MBP
HBP
LST
R134a 12.5 12.3 12.5 12.3
R600a 2.7 2.6 2.7 2.6
R 22 10.0 9.8 10.0 9.8
R404A 12.1 11.9 12.1 11.9
R507 12.5 12.3 12.5 12.3
R290 9.0 8.8 9.0 8.8
HST
R134a 2.9 2.8 13.9 13.6
R600a 1.0 1.0 6.7 6.6
R22 5.4 5.3 20.7 20.3
R404A 6.7 6.6 24.7 24.3
R507 7.0 6.9 25.4 24.9
R290 5.0 4.9 18.1 17.7
AC HST/LST
R 22 10.9 10.7 10.9 10.7
R407C 10.7 10.5 10.7 10.5
PLEASE NOTE: In order to avoid irreparable damages to the compressor, never apply voltage when
the system is under vacuum.
bar bar
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 83 - 98
7.1.8 Running time
Size the systems Ior max 80 oI normal running time.
100, under heavy load and ambient temperature conditions.
7.1.9 Cycling
The systems must be sized Ior max 5 cycles / hour (average cycling).
Compressors with PTC starting devices must be re-started aIter a minimum time oI 5 minutes
Irom their oII cycle.
The trip oI thermal /current protection requires that the compressor re-s tart occurs aIter the
necessary time Ior the protector to reset.
7.2 COMPRESSOR CONTROL PROCEDURES
The operational Iailures that may happen to the reIrigeration system can be, in most cases, iden-
tiIied and eliminated by consulting Table 40 - Troubleshooting and service chart.
The diagnostic control Ior identiIication oI the deIected component or the electrical Iailure in the
circuit can be handled by Iollowing the steps listed in the chapter 7.4 - ELECTRIC CIRCUITS
CONTROL.
7.3 TROUBLESHOOTING AND SERVICE CHART
This list oIIers the possibility to quickly identiIy, according to the apparent deIect, the possible
causes and the subsequent repairs to be made.
The listed deIects are among the most common to be Iound in established applications. For other
possible deIects which do not appear in the list or Ior running problems in the design phase oI
the application, please contact Embraco Europe Technicians in the Sales Department.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 84 - 98
Table 40 Troubleshooting and service chart
PR0BLEM POSSIBLE CAUSE REPAIR
1 Compressor will not start - No hum. 1.1 Line disconnected. S tarting relay
open
Check th e line a nd the sta rting re lay
contacts.
1.2 Fuse removed or blown. Replace the Iuse.
1.3 Overload protector tripping. Check the electrical connections.
1.4 Pressure-switch in open position. Replace the Pressure-switch.
1.5 Thermostat not correctly adjusted. Reset or replace the thermostat.
1.6 Electrical connections improper or
loose.
Check wiring against diagram, or
tighten the connections.
2 Compressor will not start (hums) but
trip on the overload protector.
2.1 Improperly wired. Check wiring against diagram. Redo the
electrical connections according to the
electrical diagram.
2.2 Low voltage at the compressor. Determine reason and correct.
2.3 Start capacitor deIective. Determine reason and replace the capac-
itor iI necessary.
2.4 Relay Iailing to close. Determine re ason a nd corr ect, r eplace
the relay iI necessary.
2.5 Compressor motor has a winding
open or shorted.
Replace the compressor.
2.6 Internal mechanical problem in
compressor.
Replace the compressor.
3 Compressor star ts, but does not
switch oII oI start winding.
3.1 Improperly wired. Check wiring against diagram.
3.2 Low voltage at the compressor. Determine reason and correct.
3.3 Run capacitor deIective. Determine reason and replace.
3.4 Relay Iailing to open. Determine reason and correct, replace iI
necessary.
3.5 Excessively high dischar ge pres-
sure.
Check discharge shut-oII valve, possible
overcharge, or insuI Iicient cooling at
condenser.
3.6 Compressor motor has a winding
open or shorted.
Replace the compressor.
3.7 Internal mechanical problem in
compressor (tight).
Replace the compressor.
4 Compressor starts and r uns, but short
cycles on overload protector.
4.1 Additional current passing through
overload protector.
Check wiring diagram. Check Ior added
Ian motors, pump, etc. connected to the
wrong side oI protector.
4.2 Low voltage at compressor (or
unbalanced iI three phase).
Determine reason and correct.
4.3 Overload protector deIective. Check current, replace protector.
4.4 Run capacitor deIective. Determine reason and replace.
4.5 Excessively high dischar ge pres-
sure.
Check ventilation, restrictions in cooling
medium, restriction in reIrigeration sys-
tem.
4.6 Excessively high suction pressure. Check Ior possibility oI incorrect appli-
cation. Use stronger unit.
4.7 Compressor too hot. Return gas
hot.
Check reIrigeran t ch arge, repair leaks,
and add gas iI necessary.
4.8 Compressor motor has a winding
shorted
Replace the compressor.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 85 - 98
5 Unit runs OK but short cycles on. 5.1 Overload protector. See section 4.
5.2 Thermostat. DiIIerential set too close. Widen.
5.3 High pressure cut-out due to insuI-
Iicient air or water supply.
Check and correct air or water supply to
condenser.
5.4 High pressure cut-out due to gas
overcharge.
Reduce the reIrigerant charge.
5.5 High pressure cut-out due to air in
the system.
Repeat vacuum and reIrigerant charge.
5.6 Low pressure cut-out due to liquid
line solenoid leaking.
Replace solenoid valve.
5.7 Low pressure cut-out due to com-
pressor valve leak.
Replace valve.
5.8 Low pressure cut-out due to gas
undercharge.
Repair leak and add reIrigerant.
5.9 Low pressur e cut-out due to
restriction in expansion valve.
Replace the expansion valve.
6 Unit operates long or continuously. 6.1 Low reIrigerant charge. Repair leak and add charge.
6.2 Control contacts stuck or Irozen
closed.
Clean contacts or replace control.
6.3 ReIrigerated or air conditioned
space has excessive load or poor
insulation.
Determine Iault and correct.
6.4 System inadequate to handle load. Replace with larger system.
6.5 Evaporator coil iced. DeIrost.
6.6 Restriction in reIrigeration system. Determine location and remove.
6.7 Dirty condenser. Clean condenser.
6.8 Dirty Iilter. Clean or replace.
7 Start capacitor open, shorted or
blown.
7.1 Relay contacts not operating prop-
erly.
Clean contacts or replace relay iI neces-
sary.
7.2 Prolonged operation on start cycle
due to low voltage to unit.
Determine reason and correct.
7.3 Prolonged operation on start cycle
due to improperly relay.
Replace the starting relay.
7.4 Prolonged operation on start cycle
due to starting load too high.
Correct by using pump down ar range-
ment iI necessary.
7.5 Excessive short cycling. Determine reason Ior short cy cling (see
section 5) and correct.
7.6 Improper start capacitor. Determine correct size and replace.
8 Run capacito r open, sho rted or
blown.
8.1 Improper run capacitor. Determine correct size and replace.
8.2 Excessively high line voltage (out
oI the allowable limit).
Determine reason and correct.
9 Relay deIective or burned out. 9.1 Incorrect starting relay. Check and replace.
9.2 Incorrect mounting angle. Remount relay in correct position.
9.3 Line voltage too high or too low. Determine reason and correct.
9.4 Excessive short cycle. Determine r eason (see section 5) and
correct.
9.5 Relay being inIluenced by loose
vibrating, mounting.
Remount tightly.
9.6 Incorrect run capacitor. Replace with proper capacitor.
10 Space temperature too high. 10.1 Control setting too high. Reset control.
10.2 Expansion valve too small. Use larger valve.
10.3 Cooling coils too small. Add surIace or replace.
10.4 Inadequate air circulation. Improve air movement.
PR0BLEM POSSIBLE CAUSE REPAIR
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 86 - 98
11 Suction line Irosted or sweating. 11.1 Expansion valv e passing ex cess
reIrigerant or is oversized.
Readjust valve or replace with smaller
valve.
11.2 Expansion valve stuck open. Clean valve oI Ioreign particles, r eplace
iI necessary.
11.3 Evaporator Ian-motor not running. Determine reason and correct.
11.4 Overcharge oI reIrigerant. Correct charge.
12 Liquid line Irosted or sweating. 12.1 Restriction in drier or strainer. Replace part.
12.2 Liquid shut-oI I (main valve) par-
tially closed.
Open valve Iully.
13 Unit noisy. 13.1 Loose parts or mountings. Locate and tighten.
13.2 Rubber grommets mounted with-
out sleeves or in correctly assem-
bled.
Add the sleeves or mount correctly.
13.3 Tubing rattle. ReIorm to be Iree oI contact.
13.4 Bent Ian blade causing vibration. Replace Ian.
13.5 Fan motor bearing worn. Replace Ian-motor.
13.6 Tubes joint incorrect (gas noise). Reconnect joint correctly.
PR0BLEM POSSIBLE CAUSE REPAIR
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 87 - 98
7.4 ELECTRIC CIRCUITS CONTROL
The electric tests reported in this chapter allow to determine the causes oI possible anomalies or
deIects oI electric components, electric motor and wiring Ior each type oI electric motor. In case
the problems appear during the Ii nal testing oI the reIrigerating application, beIore starting the
check procedures, it is better to be sure that the connections are correct according to the electric
wiring diagrams represented in Chapter 2.9. To carry out the check, it is necessary to use suitable
instruments Ior checking the cont inuity and Ior measuring the ohmic resistance, respecting the
indicated sequence and reIerring to the electric diagrams (see chapter 2.9). Consider that the con-
tinuous lines represent the leads belonging to the electric component, or to the supplied wiring,
while the dashed lines represent the suggested connection leads pertaining to the customer.
7.4.1 Standard version RSIR - RSCR EM Series with PTC starting device
(Refer to the RSIR and RSCR electric diagrams represented in Figure 9, page 24)
VeriIy, with a voltmeter, the presence oI the correct voltage on the 'L2 and 'N terminals oI
the terminal board. II there is insuIIicient voltage, the thermostat is deIective due to open con-
tacts, connections or an interruption in the cables.
Disconnect the other electrical components iI present (motor Ian, gear motor, etc.), disconnect
the voltage to the circuit at the supply line, and carry out the Iollowing operations and checks:
1. Check the continuity on the terminals L1 - L2 oI the terminal board. II there is no continuity,
the thermostat must be replaced due to open contacts.
2. Take oII the PTC starting device Irom the hermetic terminal.
3. II there is a capacitor (RSCR version), disconnect it.
4. Take oII the protector Irom the PTC starting device and check between points 1 and 3. II there
is no continuity, be sure that the prot ector has no op en contacts due to its trip. In t his case
repeat the check aIter about 10 minutes. Otherwise, the protector is deIective due to open con-
tacts.
5. Check the electric motor according to the procedure described at par. 7.5.1.
6. Check the ohmic resistance oI the stator run and start windin gs according to the procedure
described in par.7.5.2.
7. On the PTC starting device, check between the two Iastons '1 and '3 the ohmic resistance
oI the PTC pill which must be 816 / Ior the 230V model and 24 / Ior the 115V model,
at the ambient temperature oI 25 C. (CAUTION: the ohmic resistance values measured with
a normal tester can be out oI the indicated values by as much as 25 30).
8. II there is a run capacitor (RSCR version), check it according to the procedure described in
section 7.5.3.
II Irom all the above checks no problem was Iound, there is no capillary clogging and the system
does not yet run correctly, replace the compressor.
PLEASE NOTE: Wiring carried out differently from the ones indicated on the Compressor Handbook
may require a different check procedure and measurement from the one indicated.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 88 - 98
7.4.2 Standard version RSIR - RSCR EM Series with PTC starting device
(Refer to the RSIR e RSCR electric diagrams represented on Figure 10, page 24)
Verify with a voltmeter the presence of the correct voltage on the L and N terminals of the
PTC starting device. If there is insufficient voltage, the thermostat is defective due to open con-
tacts, connections, or an interruption in the cables.
Disconnect the other electrical components if present (motor fan, gear motor, etc.), disconnect
the voltage to the circuit at the supply line, and carry out the following operations and checks:
1. Check the continuity on the terminals L3 of PTC starting device. If continuity lack,s the ther-
mostat must be replaced due to open contacts.
2. Take off the PTC starting device from the hermetic terminal.
3. If there is a run capacitor (RSCR version) disconnect it.
4. Take off the protector from the PTC starting device and check between points 1 and 3. If there
is no continuity, be sure that the protector has no open contacts due to its trip. In this case,
repeat the check after about 10 minutes. Otherwise, the protector is defective due to open con-
tacts.
5. Check the electric motor according to the procedure described in par.7.5.1.
6. Check the ohmic resistance of the stator run and start windings according to the procedure
described in par.7.5.2.
7. On the PTC starting device check between the two fastons N and 2, the ohmic resistance of
the PTC pill which must be 816 for the 230V model and 24 for the 115V model, at
the ambient temperature of 25 C. (CAUTION: the ohmic resistance values measured with a
normal tester can be out of the indicated by as much as 25% 30%).
8. If there is a run capacitor (RSCR version), check it according to the procedure described in
section 7.5.3.
If from all the above checks no problem was found, there is no capillary clogging and the system
does not yet run correctly, replace the compressor.
7.4.3 Standard version RSIR NB - NE - NT - T Series with electromagnetic
current relay
(Refer to the RSIR electric diagram represented in Figure 11, page 25)
Verify with a voltmeter the presence of the correct voltage on terminals 1 of relay and 3 of
protector. If there is insufficient voltage, the thermostat is defective due to open contacts, con-
nections, or there is an interruption in the cables.
Disconnect the other electric components if present (motor fan, gear motor, etc.), disconnect the
voltage to the circuit at the supply line, and carry out the following operations and checks:
1. Check the continuity between the points 1 - 3 of protector: If there is no continuity, be
sure that the protector has no open contacts due to its trip. In this case, repeat the check after
about 10 minutes.
2. Take off the start relay from the hermetic terminal and keeping it in the same vertical posi-
tion, (do not incline or overturn) carry out the following continuity checks.
3. Between the terminals 1 and S on the relay: If there no continuity the relay is faulty due
to closed contacts.
PLEASE NOTE: The contacts of the starting relay are normally open.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 89 - 98
4. Between the terminals 1 and R of relay: If there is no continuity the relay has an open
coil.
5. Check the electric motor according to the procedure described in par. 7.5.1.
6. Check the ohmic resistance of the stator run and start windings according to the procedure
described in par. 7.5.2.
If from all above checks, no problem was found, there is no capillary clogging, and the system
does not yet run correctly, replace the starting relay, excluding possible faults of contacts open-
ing and closing (pick-up and drop-out current) that can not to be determined with above checks.
If the compressor does not yet run correctly, it must be replaced due to internal defects.
7.4.4 Standard version CSIR NB - NE - NT Series with electromagnetic current
relay
(Refer to the electric diagram CSIR represented in Figure 11, page 25)
Verify with a voltmeter the presence of the correct voltage on the terminals 2 of relay and 3 of
protector. If there is insufficient voltage, the thermostat is defective due to open contacts, con-
nections, or there is an interruption in the cables. Disconnect the other electric components if
present (motor fan, gear motor, etc.), disconnect the voltage to the circuit at the supply line and
carry out the following operations and checks:
1. Check the continuity between the points 1 and 3 of the protector. If continuity lacks, be sure
that the protector has no open contacts due to its trip. In this case repeat the check after about
10 minutes.
2. Take off the start relay from the hermetic terminal and keep it in the same vertical position
(do not incline or overturn). Carry out the following continuity checks:
3. Between the terminals 1 and S on the relay: if there is continuity the relay is faulty due to
closed contacts.
4. Between the terminals 2 and R of relay: if there is no continuity the relay coil is open.
5. Check the electric motor according to the procedure described in section 7.5.1.
6. Check the ohmic resistance of the stator run and start windings according to the procedure
described on section 7.5.2.
7. Check the start capacitor according to the procedure indicated on section 7.5.3.
If from all the above checks, a problem was not found, there is no clogging in the expansion de-
vice and the system does not yet run correctly, replace the starting relay, excluding possible faults
of the contacts opening and closing (pick-up and drop-out currents) that can not be determined
with above checks.
If the compressor does not yet run correctly, it must be replaced due to internal defects.
PLEASE NOTE: The contacts of starting relay are normally open.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 90 - 98
7.4.5 Terminal board version RSIR NB - NE - T Series with electromagnetic
current relay
(For T Series, refer to the RSIR electric diagram represented in Figure 12, page 25)
(For NB-NE Series, refer to the RSIR electric diagram represented in Figure 13, page 26)
Verify with a voltmeter the presence of the correct voltage on the terminals 1 and N of the
terminal board. If there is insufficient voltage, the thermostat is defective due to open contacts,
connections, or there is an interruption in the cables.
Disconnect the other electric components if present (motor fan, gear motor, etc.), disconnect the
voltage to the circuit at the supply line and carry out the following operations and checks:
1. Remove the terminal board, take off the starting relay and disconnect the protector cable from
the hermetic terminal.
2. Protector: Check the continuity between the points 1 of protector, and 1 of terminal
board. If there is no continuity, the protector can be:
faulty due to open contacts
tripped; then repeat the check after about 10 minutes
not connected to the terminal board.
3. Keep the start relay in the same vertical position as assembled on the hermetic terminal (do
not incline or overturn), and carry out the following continuity checks:
4. Between the terminals N on the terminal board and S on the relay: if there is continuity
the relay is defective due to closed contacts.
5. Between the terminals N on the terminal board and R of relay: if there is no continuity,
the defect can be due to:
relay with open coil
relay not connected to the terminal board.
6. Check the electric motor according to the procedure described on section 7.5.1.
7. Check the ohmic resistance of the stator run and start windings according to the procedure
described in section 7.5.2.
If from all above checks, a problem was not found, there is no capillary clogging, and the system
does not yet run correctly, replace the starting relay, excluding possible faults of contacts open-
ing and closing (pick-up and drop-out currents) that can not be determined with above checks.
If the compressor does not yet run correctly, it must be replaced due to internal defects.
7.4.6 Terminal board version CSIR NB - NE - NT - T Series with electro-
magnetic current relay
(For T Series, refer to the electric diagram CSIR represented on Figure 12, page 25)
(For NB-NE Series, refer to the electric diagram CSIR represented on Figure 13, page 26)
Disconnect the other electric components if present (motor fan, gear motor, etc.), disconnect
voltage to the circuit at the supply line, and carry out the following operations and checks:
PLEASE NOTE: The contacts of the starting relay are normally open.
PLEASE NOTE: The contacts of starting relay are normally open.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 91 - 98
1. Remove the terminal board, take oII the start relay and disconnect the protector cable Irom
the hermetic terminal.
2. Protector: check the continuity between the points '1 oI protector, and '1 oI terminal board.
II there is no continuity, the protector can be:
Iaulty due to open contacts
tripped; then repeat the check aIter about 10 minutes
not connected to the terminal board.
3. Keeping the starting relay in the same vertical position as assembled on the hermetic terminal
(do not incline or overturn), carry out the Iollowing continuity checks.
4. Between the terminals N on the terminal board and R oI rel ay: iI there is no continuity, the
deIect can be due to:
relay with coil breaking
relay not connected to the terminal board.
5. Between the terminals 1 and S oI relay: iI there is continuity, the relay is Iaulty due to closed
contacts.
6. Check the electric motor according to the procedure described in par. 7.5.1.
7. Check the ohmic resistance oI the stator run and starting windings according to the procedure
described in par. 7.5.2.
8. Check the starting capacitor according to the procedure indicated in par. 7.5.3.
II Irom all above checks no problem was Iound, there are no cl ogging in the expansion device
and the system does not yet run correctly, replace the starting relay, excluding possible Iaults oI
contacts opening and closing (pick-up and drop-out currents) that can not be determined with
above checks.
II the compressor does not yet run correctly, it must be replaced due to internal deIects.
7.4.7 Terminal board version RSIR and RSCR NB Series with PTC starting
device
(Refer to the electric diagrams RSIR and RSCR PTC represented on Figure 14, page 26)
Disconnect electrically, other electric components iI present (motor Ian, gear motor, etc.), inter-
rupt the voltage to the circuit disconnecting it Irom the supply line, and carry out the Iollowing
operations and checks:
1. Remove the terminal board, take oII the PTC starting device Irom the hermetic terminal and
disconnect the protector lead Irom the hermetic terminal.
2. Check on the protector the con tinuity bet ween t he points 1 oI protector and 1 o I t erminal
board. II continuity lacks the protector can be:
Iaulty Ior open contacts
tripped, then repeat the check aIter about 10 minutes
not connected to the terminal board.
3. Check, on the PTC starting device, the continuity between the points oI PTC starting device
and N oI terminal board. II continuity lacks check the lead and its connections.
4. II there is a run capacitor (RSCR version), disconnect it.
5. Check the electric motor according to the procedure described in section 7.5.1.
6. Check the ohmic resistance oI the stator run and start windin gs according to the procedure
described in section 7.5.2.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 92 - 98
7. On PTC starting device check, between the two faston terminals 1 and 3 the ohmic resistance
of the PTC pill which must be 816 for the model at 230V and 24 for the model at
115V, at the ambient temperature of 25 C.
8. If there is the run capacitor (RSCR version), check it according to the procedure described in
par. 7.5.3.
If from all the above checks, no problem was found, there is no capillary clogging and the system
does not yet run correctly, replace the compressor.
7.4.8 Standard version PSC NE - NT - NJ Series
(Refer to the electric diagrams PSC represented on Figure 15, page 27)
Verify with a voltmeter the presence of the correct voltage between the terminals R and C of the
hermetic terminal (version with internal protector), or between R on hermetic terminal, and 1 on
external overload protector. If there is insufficient voltage, the thermostat is faulty due to open
contacts or there is an interruption on the cables or on the connections.
Disconnect the other electric components if present (motor fan, gear motor, etc.), interrupt volt-
age to the circuit atom the supply line, and carry out the following operations and checks:
1. If there is an external overload protector, check the continuity between points 1 and 3. If there
is no continuity, the protector can be faulty, or there could have been a trip, so repeat the
check after about 10 minutes.
2. Check the electric motor according to the procedure described in section 7.5.1.
3. Check the ohmic resistance of the stator run and start windings according to the procedure
described in section 7.5.2.
4. Check the run capacitor according to the procedure indicated in section 7.5.3.
If from all above checks, no problem was found, there are no clogging in the expansion device,
and the system does not yet run correctly, replace the compressor.
7.4.9 Standard versions CSR - CSR BOX NE - NT - NJ Series with potential
current relay
(Refer to the electric diagrams CSR represented in Figure 15, page 27)
(Refer to the electric diagrams CSR BOX represented in Figure 16, page 27)
Verify with a voltmeter the presence of the correct voltage on the terminals 4 and 5 of the starting
relay. If there is insufficient voltage, the thermostat is faulty due to open contacts, connections,
or there is an interruption in the cables.
Disconnect the other electric components if present (motor fan, gear motor, etc.), interrupt the
voltage to the circuit disconnecting it from the supply line and carry out the following operations
and checks:
1. Disconnect all the connections on terminals 2 and 5 of the starting relay.
2. Check the continuity between terminals 2 and 5 of the starting relay. If there is no continuity,
there is a broken coil and the relay must be replaced.
3. Check the continuity between the terminals 1 and 2 of the starting relay. If there is no conti-
nuity, the contact is open and the relay must be replaced.
4. If there is an external overload protector, check, according to the type, the continuity between
the terminals 1 and 3 or 1 and 2. If there is no continuity, the protector can be faulty or there
could have been a trip, so repeat the check after about 10 minutes.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 93 - 98
5. Check the electric motor according to the procedure described in section 7.5.1.
6. Check the ohmic resistance of the stator run and start windings according to the procedure
described in section 7.5.2.
7. Disconnect one of the two cables of the starting capacitor.
8. Check the start and run capacitors according to the procedure described in section 7.5.3.
9. Check the continuity of the cables disconnected from the 2 and 5 terminals of the starting re-
lay.
If from all above checks, no problem was found, there is no clogging in the expansion device,
and the system does not yet run correctly, replace the starting relay, excluding possible mistakes
of opening and closing of the contacts (pick-up and drop-out currents) that can not be found with
above checks.
If the compressor does not yet run correctly, it must be replaced due to internal defects.
7.4.10 Standard versions CSIR and CSIR BOX NT and NJ Series with current
electromagnetic relay
(Refer to electric diagrams CSIR represented on Figure 17, page 28)
(Refer to electric diagrams CSIR BOX represented on Figure 18, page 28)
Verify with a voltmeter the presence of the correct net voltage on the terminals 3 and 5 of the
starting relay. If there is insufficient voltage, the thermostat is defective due to open contacts,
connections, or there is a break in the cables.
Disconnect the other electric components, if present (motor fan, gear-motor, etc.), interrupt the
voltage to the circuit at the supply line, and carry out the following operations and checks:
1. Disconnect all connections on terminal 3 of the starting relay.
2. Keeping the start relay in the same vertical position as assembled on the hermetic terminal
(do not incline or overturn), carry out the following continuity checks:
3. Check the continuity between the terminals 3 and 4 of the starting relay. If there is no conti-
nuity, the coil is interrupted and the relay must be replaced.
4. Check the continuity between the terminals 1 and 2 of the starting relay. If there is continuity,
the contact is closed and the relay must be replaced.
5. Check the protector continuity between points 1 and 3. If there is no continuity, the protector
can be:
defective
tripped; then repeat the check after about 10 minutes.
6. Check the electric motor according to the procedure described in section. 7.5.1.
7. Check the ohmic resistance of the stator start and run windings according to the procedure
described in section 7.5.2.
8. Check the start capacitor according to the procedure indicated in section 7.5.3.
9. Check the continuity of the cables disconnected from terminal 3 of the start relay.
If from all above checks, no problem was found, there is no clogging in the expansion device,
and the system does not yet run correctly, replace the starting relay, excluding possible mistakes
of opening and closing of the contacts (pick-up and drop-out currents) that can not be found with
PLEASE NOTE: The contacts of the starting relay are normally open.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 94 - 98
above checks.
If the compressor does not yet run correctly it must be replaced due to an internal defects.
7.4.11 Standard version CSIR NJ Series with current electromagnetic relay
(Refer to the electric wiring CSIR BOX represented in Figure 19, page 29)
Verify with a voltmeter the correct voltage on the terminals 4 and 5 of the starting relay. If there
is insufficient voltage, the thermostat is defective due to open contacts, connections, or there is
an interruption in the cables.
Disconnect the other electric components if present (motor fan, motor-gear, etc.), interrupt the
voltage to the circuit at the supply line, and carry out the following operations and checks:
1. Disconnect all the connections on terminals 2 and 5 of the starting relay.
2. Check the continuity between terminals 2 and 5 of the starting relay. If there is no continuity,
there is an interruption on the coil and the relay must be replaced.
3. Check the continuity between the terminals 1 and 2 of the starting relay. If there is continuity,
the contact is open and the relay must be replaced.
4. Check the protector the continuity between the points 1 and 3. If there is no continuity, the
protector can be defective or tripped, then repeat the check after about 10 minutes.
5. Check the electric motor according to the procedure described in section 7.5.1.
6. Check the ohmic resistance of the stator run and start windings according to the procedure
described in section 7.5.2.
7. Check the start capacitor according to the procedure described in section 7.5.3.
8. Check the continuity of the cables disconnected from the terminals 2 and 5 of the start relay.
If from all above checks, no problem was found, there is no clogging in the expansion device and
the system does not yet run correctly, replace the starting relay, excluding possible mistakes of
opening and closing of the contacts (pick-up and drop-out currents) that cannot be determined
with above checks.
If the compressor does not yet run correctly it must be replaced due to an internal defects.
7.4.12 Three-Phase Version NJ
(Refer to the electric wiring THREE-PHASE represented in Figure 20, page 29)
Verify with a voltmeter the presence of the correct voltage of the three phases, on the three pins
of the hermetic terminal. If there is insufficient voltage, check the presence of a break on the con-
tacts of relay, cables and connections.
Disconnect the other electric components if present (motor fan, motor-gear, etc.), interrupt the
voltage to the circuit at the supply line, and carry out the following checks:
1. Check the continuity of the windings of the three phase electric motor, among the pins of the
hermetic terminal (3 measures carried out between 2 pins at a time). The lack of continuity
indicates an interruption in the electric motor winding.
2. Check the continuity among the three pins of the hermetic terminal and the ground plate on
the compressor. If there is continuity, the electric motor has the windings shorted.
3. Check with a suitable instrument the ohmic resistance of the three phases of the stator wind-
ings, through the three pins of the hermetic terminal on the compressor.
COMPRESSORS
HANDBOOK
Chapter
RUNNING DATA AND COMPRESSOR CHECKING PROCEDURES
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 95 - 98
The values oI resistance indicated on the Electric Components List must result within the toler-
ance oI +10 at the ambient temperature oI 25 C.
II Irom all above checks no problem was Iound, there is no clogging in the expansion device and
the system still does not run correctly, replace the compressor.
7.5 CONTROL PROCEDURES
7.5.1 Control of electric motor stator windings
Check the continuity between the pins C and S oI the hermetic terminal. II there is no conti-
nuity, there is an interruption in the electric motor start winding.
Check the continuity between the pins C and R oI the hermetic terminal. II there is no conti-
nuity, there is an interruption in the electric motor run winding.
Check the continuity between the pin C oI the hermetic terminal and the ground plate on the
compressor. II there is continuity, the electric motor windings are shorted to ground.
7.5.2 Control of stator windings ohmic resistance
Check with a suitab le instrument the ohmic resistance oI the start and run stator windings
through the three pins oI hermetic terminal on compressor.
The values Rm and Ra indicated on the Electric Components List must be within the tolerance
oI +10 at ambient temperature oI 25 C, measured on the pins C-R Ior run and C-S Ior start.
7.5.3 Control of start and run capacitors
BeIore checking the electrolytic start capacitor, unsolder one oI the two wire terminals oI the
bleed resistor which is connected between the two terminals.
Check the start and run capacitor on the two terminals, using an indicating pointer instrument
set as in the Iollowing:
With ohmmeter scale R x 10: iI t he pointer moves rapidly Irom inIinity position to zero
returning to the inIinity position, the capacitor is good.
With ohmmeter scale R x 10: measuring continuity (resistance near to zero) the capacitor
is short-circuited and must be replaced.
With ohmmeter scale R x 100000: iI no indication is given by the instrument, the capacitor
is internally interrupted and it must be replaced.
PLEASE NOTE: Each of the three phases can have different ohmic resistance values.
COMPRESSORS
HANDBOOK
Chapter
HOW TO RETURN SUPPLIED PRODUCTS TO EMBRACO EUROPE
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 96 - 98
8 HOW TO RETURN SUPPLIED PRODUCTS
TO EMBRACO EUROPE
8.1 CONDITIONS
For the warranty on products supplied by Embraco Europe Srl, reIer to what is indicated in the
sales conditions.
The validity oI the warranty is subject to the Iollowing conditions and to the results oI the Tech-
nical Report sent to the Customer by the Sales and Marketing Department. The Customer must
advise the Sales and Marketing Department about the deIect Iound on the product and supply all
useIul data Ior a preliminary analysis. II necessary, it can be agreed upon with the Customer that
the return oI deIective material can be sent to Embraco Europe Product Quality Assurance Lab-
oratory with detailed inIormation on the deIect, which is necessary Ior a rapid and accurate anal-
ysis. The Bill oI Lading accompanying the material should report the Iollowing description:
1. Return of rejected product: deIective material to be returned Ior analysis. In this case,
depending upon the warranty conditions and the analysis results, the material can be replaced
with new components.
2. Sending for destructive tests: Ior material to be submitted to destructive tests, without
warranty conditions. In this case, all or some oI the deIective material can be returned to the
customer, iI required.
In case oI incorrectly shipped material, the customer, with reIerence to the Embraco Bill oI Lad-
ing, must inIorm the Sales Department, who will see to correct the error.
The Bill oI Lading accompanying the material should report the Iollowing desctiption:
1. Returned material not corresponding to the order, Ior the mat erial shipped not in ac-
cordance to the order.
2. Returned material in quantity exceeding the order, Ior the material supplied in greater
quantity versus the order.
The deIective material sent to Embraco Europe by the Customer, must comply to the Iollowing
conditions:
The compressors must:
be provided with nameplate and sealed with original plugs.
not be emptied oI the oil remaining aIter the disassembling Irom the system.
be handled and transported in order not to suIIer strong shocks, Ialls and possible damag-
es.
be equi pped with electrical components, pro perly marked (compressor an d electrical
components) to allow their correct coupling.
All materials must be properly packaged according to the type oI shipment and in order not
to suIIer damages during transport.
The material returned Ior analysis must be accompanied by a detailed description oI the Iail-
ure, how it happened and all useIul data Ior a correct diagnosis oI the deIect.
PLEASE NOTE: Due to administrative reasons, never indicate on the delivery note in vision account
or in pending account.
COMPRESSORS
HANDBOOK
Chapter
HOW TO RETURN SUPPLIED PRODUCTS TO EMBRACO EUROPE
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 97 - 98
Do not return defective compressors as a consequence of mishandling.
Do not return open compressors or tampered components. (To avoid erroneous diagno-
sis, the compressors must be opened with suitable tools, available only at Embraco Europe).
The material that does not correspond to the above requirements may be considered not valid Ior
analysis and may void the warranty.
All the material that, aIter analysis, may appear to be working and are Iree oI quality problems,
can neither be returned nor replaced (the complete analysis involves the opening oI the compres-
sor and its disassembling).
The analyzed product, beIore its dismantling, remains at the customer`s disposal Ior a minimum
period oI 30 days starting Irom the date in the Technical Report issued by the Sales and Market-
ing Department.
For the Aspera compressors returned to Embraco Europe, the Customer will get a credit based
on the scrap value oI the dismantled material.
8.2 TESTS ON THE CUSTOMER APPLICATIONS
Embraco Europe Srl puts at the customer`s disposal the 'Application Tests Laboratory, to per-
Iorm the tests Ior veriIying the running oI their equipment; Ior deIining the compressor and the
main components oI the reIrigeration system (condenser, evaporator, capillary) and other special
tests.
The customer can request Irom the 'Technical Liaison - Sales & Marketing Department to agree
on the Ieasibility oI the requested test, the delivery oI the equipment and the terms, according to
the development program oI the laboratory tests.
The equipment must be sent to the 'Application Tests Laboratory with the Bill oI Lading re-
porting the Iollowing description:
1. For destructive tests The equipment will not to be returned to the Customer unless agreed
diIIerently.
The test results will be given to the customer, who can use them as inIormation or to deIine or
modiIy his application.
PLEASE NOTE: THE TRANSPORT EXPENSES ARE CHARGED TO THE CUSTOMER
PLEASE NOTE: THE TEST RESULTS CANNOT BE USED IN CASE OF CONTROVERSY AND ACTIONS
BROUGHT AGAINST A THIRD PARTY, UNLESS THERE IS A WRITTEN AUTHORIZATION FROM EMBRACO
EUROPE Srl.
COMPRESSORS
HANDBOOK
Chapter
HOW TO RETURN SUPPLIED PRODUCTS TO EMBRACO EUROPE
Doc. Code Emission Revision Date Page
MP01EH 2000-04 07 2010-02 98 - 98
Rui Barbosa, 1020 - P.O. BOX 91
89219-901 - Joinville - SC - Brazil
Phone: +55 47 3441-2121
Fax: +55 47 3441-2780
^
C
o
d
e
M
P
0
1
E
H
-
D
a
t
e
F
e
b
r
u
a
r
y
2
0
1
0
-
V
e
r
s
io
n
0
7
-
S
u
b
je
c
t
t
o
a
lt
e
r
a
t
io
n
w
it
h
o
u
t
p
r
e
v
io
u
s
n
o
t
ic
e