Digital Axle Counter
Digital Axle Counter
Digital Axle Counter
G.D.CHANDOLIA
IT IS MEANS FOR DETECTION OF TRAIN ON A TRACK. IT IS HAVING TWO SETS OF TRANSDUCERS & A PROCESSSOR. ONE SET IS INSTALLED AT THE ENTRANCE OF LENGTH OF TRACK WHICH COUNTS IN. ANOTHER SET IS INSTALLED AT THE EXIT OF LENGTH OF TRACK WHICH COUNTS OUT. THE PROCESSOR PROCESS THE COUNTS IN & COUNTS OUT AND CLEAR THE LINE IF THEY ARE EQUAL & SHOWS OCCUPIED IF THEY ARE NOT EQUAL.
MONITORS VERY LONG TRACK SECTIONS IMMUNE TO BALLAST RESISTANCE INSENSITIVE TO TEMPERATURE VARIATION INDEPENDENT OF TYPE & QUALITY OF RAILS, SAND FORMATION & WATER LOGGED TRACKS IMMUNE TO TRACTION RETURN CURRENTS
TRACK CIRCUITING OF BERTHING TRACKS TRACK CIRCUITING OF POINT ZONE TRACKS VERIFICATION OF COMPLETE ARRIVAL OF TRAIN INTERMEDIATE BLOCK SIGNALLING AUTOMATIC SIGNALLING TRAIN ACTUATED WARNING DEVICE
4 5
1994 2002
7000 100
Rx1
RX1 AXLE DETECTOR
SCC1
MLB 1
MODEM
TO NEXT SSDAC
TX2
SCC2
RX2
PULSE 2
MLB 2
AXLE DETECTOR
LEGEND SCC 1 & 2 : SIGNAL CONDITIONER CARD MLB 1 & 2 : MICROCONTROLLER LOGIC BLOCK
1 NO. (COMMON RESETTING) 2 NOS. (INDEPENDENT RESETTING) VITAL RELAY - QS3 ( 24V) 2 NO. POWER SUPPLY ARRANGEMENT 24 V DC(2 Nos.) AS PER
AXLE DETECTORS
FREQUENCY OF 21KHz & 23KHz TX/RX COILS ARE USED. WEB TYPE AXLE DETECTORS DEFLECTOR BRACKET ASSEMBLY COMPATIBLE WITH 90R,52 KG & 60 KG RAIL PROFILES DETECTION OF ALL WHEELS WITH WHEEL DIA > 400 MM
ADJ
ADJ Tx
CLOCK MLB 1 CLEAR CLOCK MLB 2 CLEAR RELAY DRIVE OCCUPIED CLEAR OCCUPIED CLEAR
2.2V DC
2.2V DC
STATUS SIGNALS
STATUS SIGNALS
Rx MODE CD
0V DC
0V DC
PULSE OK LD OK OSC OK
PULSE OK LD OK
+15V ISO
OSC OK
SCC - 1
SCC - 2
MLB1
MLB2
MODEM CARD
RELAY CARD
DC- DC
GENERATION OF CARRIER SIGNAL FOR TX COILS DEMODULATION OF SIGNAL FROM RX COILS GENERATION OF VALID PULSES COUNT THE PULSES TO COMPUTE THE NUMBER OF PASSING WHEELS EXCHANGE & COMPARISON OF COUNTS BETWEEN TWO SSDAC UNITS GIVING A VITAL RELAY OUTPUT ERROR CHECKING AND DISPLAY
DESIGNED AS PER CENELEC STANDARDS OF HIGHEST SAFETY INTEGRITY LEVEL 4 (SIL-4). BASED ON FAIL SAFE PRINCIPLE BASED ON 2 OUT OF 2 LOGIC ALL THE CARDS ARE OF EXTENDED SINGLE EURO SIZE(220mmX100mm) MOTHERBOARD FOR INTER CARD CONNECTIONS PHYSICAL DIMENSIONS 300X133X300mm FIRST TIME DEVELOPED INDIGENOUSLY BY CEL & RDSO.
CARD 1 CARD 2 CARD 3 CARD CARD 4 CARD CARD 5 CARD 6 CARD 7 CARD 8
SIGNAL CONDITIONING CARD FOR 21 KHz SIGNAL CONDITIONING CARD FOR 23 KHz MICRO CONTROLLER LOGIC & ERROR DISPLAY MICRO CONTROLLER LOGIC & ERROR DISPLAY EVENT LOGGER CARD(OPTIONAL) MODEM CARD RELAY DRIVER CARD DC-DC CONVERTOR CARD
GENERATION OF CARRIER SIGNALS OF 21 KHz OR OF 23 KHz FOR TX COILS DEMODULATION OF RECEIVER COIL SIGNAL OF 21 KHz OR OF 23 KHz FROM RX COILS ADJUSTMENT OF RECEIVER SIGNAL WITH POTENTIOMETER GENERATION OF WHEEL PULSE PULSE SHAPING TROLLEY SUPPRESSION TRACK CIRCUIT GENERATION OF SUPERVISORY SIGNAL
THE CARRIER SIGNALS OF 21 KHz OR OF 23 KHz FOR TX COILS ARE GENERATED WITH OUTPUT VOLTAGE AS 30V TO 40V rms & FREQUENCY VARIATION OF 20 KHz. THERE IS A LEVEL DETECTOR CIRCUIT WHICH CHECKS THE LEVEL OF RECEIVER COIL OUTPUT TO ADJUST THE LEVEL OF DEMODULATED SIGNAL FROM RX COIL, POTENTIOMETER HAS BEEN PROVIDED. TO INHIBITE COUNTING DUE TO TROLLEYS , TRACK CIRCUIT CONTACTS ARE CONNECTED PULSE SHAPER CIRCUIT HAS BEEN PROVIDED BY USING HYBRIDS .
TWO IDENTICAL CARDS TO HAVE 2 OUT OF 2 LOGIC MONITOR & RECEIVE PULSE SIGNAL OUTPUT PULSE SIGNAL TO OTHER MICRO CONTROLLER LOGIC CARD DETECT THE DIRECTION OF MOVEMENT COUNTING THE WHEELS PASSSING OVER DETECTOR SUPERVISION OF AXLE DETECTORS, PRESENCE OF CARDS CODE MESSAGE PACKETS FOR TRANSMISSION TO REMOTE COUNTING UNIT
DECODE MESSAGE PACKETS RECEIVED FROM REMOTE COUNTING UNIT DETERMINE THE NUMBER OF AXLES IN THE SECTION CONTROL & SUPERVISE THE STATUS OF VITAL RELAY. GENERATION OF SYSTEM ERROR CODES GENERATION OF CLOCK RECEIVING THE RESET COMMAND FROM MODEM CARD
MICRO CONTROLLER IS BASED ON STANDARD 89C51 RS232 COMPATIBLE SERIAL PORT FOR MODEM CONNECTIVITY
1OK BYTE ON CHIP FLASH ROM FOR PROGRAM STORAGE 256 BYTE ON CHIP RAM PARALLEL PORTS FOR ADDRESS /MODE INPUT, PULSE INPUTS & VITAL RELAY OUTPUT
LED DISPLAY FOR COUNT PROGRESS/ ERROR DISPLAY LED INDICATORS FOR SECTION STATUS
ON ON
1 4 10 40
2 8 20 80
LIST OF ERRORS
S.NO 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. CARD_TEST RELAY_TEST CARD_TEST_INLINE LINK_ERROR SEQUENCE_ERROR SELF_COUNT_MISMATCH INPUT_ERROR OUT_B4_IN_ERROR NEGATIVE_COUNT_ERROR SHUNT_ERROR SUP_ERROR COMM_ERROR ERROR ERROR NUMBER (HEX NUMBER) 14 15 24 30 31 32 33 34 35 36 37 40
IT PROVIDES SIGNAL CONVERSION FROM DIGITAL TO ANALOG AND VICE-VERSA AS PER CCITT V.21 STANDARD.
IT IS USED FOR COMMUNICATION BETWEEN TWO COUNTING UNITS WHICH IS IN THE FORM OF DATA PACKETS
DATA PACKETS CONSISTS OF COUNT CHANGE INFORMATION, COUNT UPDATE INFORMATION, POWER ON/RESET INFORMATION & ERROR INFORMATION IF ANY.
IT INTERFACES WITH SERIAL RS232C PORT OF BOTH MICRO CONTROLLER LOGIC CARDS.
MULTIPLEXES THE TWO SERIAL PORTS AMD 7911 FSK MODEM CHIP V.21 MODE OF OPERATION (2 WIRE) 300 BAUD RATE TRANSMISSION SETTING IN ORIGINATOR(ENTRY UNIT) & ANSWERER(EXIT UNIT) MODE.
SWITCH SELECTABLE GAINS IN RECEIVE & TRANSMIT PATH LED INDICATORS FOR SECTION STATUS
TX RX
FLASHING FLASHING
TRANSMITTING THE SIGNAL RECEIVING THE SIGNAL NOT IN NETWORKING CARRIER IS DETECTED
MODE OFF CD ON
IT CHECKS & GENERATES THE VITAL RELAY DRIVE OUTPUT. THIS OUTPUT IS USED TO DRIVE FAIL SAFE VITAL RELAY THE OUTPUT IS GENERATED ONLY WHEN THE SELF COUNT & REMOTE COUNTS ARE MATCHED AND EQUAL
DUAL CLOCK CHECKING CIRCUIT OPTO ISOLATOR CIRCUIT VITAL RELAY DRIVE OUTPUT CIRCUIT LED INDICATORS FOR CLOCK. CLEAR PULSE RELAY DRIVER OUTPUT
MLB1 BALANCED MLB1 CLOCK MLB2 BALANCED MLB2 CLOCK RELAY DRIVE
COUNTS ARE SECTION IS CLEAR COUNTS ARE SECTION IS CLEAR 24V DC AVAILABLE
IT RECEIVES 24V BATTERY/IPS INPUT. IT GENERATES 5V,12V,24V OUTPUT WITH COMMON GROUND
INPUT RANGE IS 18V TO 30V OUTPUT RATING 5V 2A, 12V 200mA, 24V 300mA & 15V100mA
LOAD REGULATION 0.1% & 0.5% INPUT & OUTPUT PROTECTED AGAINST SHORT CIRCUIT INPUT REVERSE POLARITY PROTECTION LOW RIPPLE, EFFICIENCY BETTER THAN 50%, NO OVERSHOOT/UNDERSHOOT.
ON ON ON ON
IT IS REQUIRED TO MAKE THE SYSTEM NORMAL IN CASE AXLE COUNTER HAS FAILED/SWITCHING ON POWER SUPPLY.
AS PER SAFETY REQUIREMENT, TO NORMALISE THE AXLE COUNTER, THE FIRST TRAIN SHALL BE PILOTED IN THE SECTION AFTER RESETTING TO REGISTER BALANCE OF COUNTS IN THE SYSTEM
IT IS HAVING LED INDICATION FOR SECTION STATUS IT IS HAVING SMS KEY ACTUATOR & RESET BUTTON COUNTER FOR RECORDING NO. OF RESET PREPARATORY RESET RELAY (PPR1) MINITURE RELAY INPUT VOLTAGE 24V DC 24V TO 48V DC- DC CONVERTOR 48V IS USED FOR RESETTING
ON ON
ON
PRESENCE OF 24V
TYPICAL 10 - 20 KM AS 4
VITAL RELAY POWER
4 2
4 SSDAC-2
4
VITAL RELAY POWER
BLOCK/ INTERLOCKING EQUIPMENT
SSDAC-1
THANKS