Orifice Size Calculation: A. Input Data

1. The document provides calculations for determining the size of an orifice based on input data including flow rate, nozzle diameter, pressure difference, and fluid density. 2. It presents the calculation formulas and shows applying the formulas to sample input data values to determine the orifice diameter. 3. The results of the sample calculation determine the recommended orifice size as 3.346 mm based on the input flow rate of 0.25 kg/s and other provided parameter values.

Uploaded by

kangrim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
159 views5 pages

Orifice Size Calculation: A. Input Data

1. The document provides calculations for determining the size of an orifice based on input data including flow rate, nozzle diameter, pressure difference, and fluid density. 2. It presents the calculation formulas and shows applying the formulas to sample input data values to determine the orifice diameter. 3. The results of the sample calculation determine the recommended orifice size as 3.346 mm based on the input flow rate of 0.25 kg/s and other provided parameter values.

Uploaded by

kangrim
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

ORIFICE SIZE CALCULATION

A. INPUT DATA
Vent sat. water flowrate

Qm

900

kg/h

0.250000

kg/s

Vent nozzle dia.

0.0143

Diff. Pressure

dp

11.00

bar

1100000

pa

988

kg/m3

Vent sat. water dens.

B. FORMULAR
d^2 =

4Qm / (0.61 D^2 (2 dp r)^0.5) =

d=

0.2340 mm

C. VENT DIA.
dxD=

3.3455 mm

SIZE ========>

3.346 mm

0.054734

ORIFICE SIZE CALCULATION


ORIFICE CALCULATION
1

LIQUID

Calculation formula
Q

* a

2g ( h1 - h2 )

* a

2g ( p1 - p2 )/

m = a / A = d2 / D2

----

( 1 )

----

( 2 )

----

( 3 )

( 1 ) , ( 2 )
Q

=
=

Data

Q
m

D
d
a
A
p1
p2

:
:
:
:
:
:
:
:
:
:

12511 * m * * D2

( p1 - p2 )/

138.132 m3/h
Capacity
a / A
Flow coefficient
Pipe india.
Orifice india
Area of orifice india.
Area of pipe inside
Press. Of inlet
Press. Of outlet
Density of liquid
at orifice inlet

=
=
=
=
=
=
=
=
=
=

138.1319966
1
0.62
0.10226
0.10226
0.008212993
0.008212993
0.29
0
1000

m3/h

m
m
m2
m2
kg/m2
kg/m2
kg/m3

100
125
150
200
250

102.3
126.6
151
199.9
248.8

pipe size
40

102.26

orifice
102.26 mm
21.375
327
305.625

mm

Medium GAS

<< Air >>

-100
-50
-20
0
20
40
60
80
100
120
140
160
180
200
250
300
350
400
500
600
800
1000

kg/m3
1.984
1.533
1.348
1.251
1.166
1.091
1.026
0.968
0.916
0.869
0.827
0.789
0.754
0.722
0.652
0.596
0.548
0.508
0.442
0.391
0.319
0.265

* *
40
50
60

1.091
1.0585
1.026

kcal/kg
0.2410
0.2400
0.2400
0.2400
0.2400
0.2410
0.2410
0.2410
0.2420
0.2420
0.2430
0.2430
0.2440
0.2450
0.2470
0.2500
0.2530
0.2550
0.2610
0.2670
0.2760
0.2850

Prandtl
kgs/m2
m2/s
kcal/mh
1.2100
0.0600
0.0135
0.770
1.4900
0.0950
0.0172
0.730
1.6500
0.1200
0.0193
0.730
1.7600
0.1380
0.0207
0.720
1.8600
0.1560
0.0221
0.710
1.9500
0.1750
0.0234
0.710
2.0500
0.1960
0.0247
0.710
2.1400
0.2170
0.0260
0.700
2.2300
0.2390
0.0272
0.700
2.3200
0.2620
0.0285
0.700
2.4000
0.2850
0.2970
0.690
2.4800
0.3080
0.0309
0.690
2.5600
0.3330
0.0320
0.690
2.6400
0.3580
0.0332
0.690
2.8300
0.4260
0.0359
0.690
3.0100
0.4950
0.0386
0.690
3.1800
0.5690
0.0412
0.690
3.3400
0.6450
0.0437
0.690
3.6500
0.8100
0.0483
0.700
3.9400
0.9890
0.0527
0.700
4.4700
1.3700
0.0610
0.710
4.9400
1.8300
0.0690
0.720

You might also like