UF Table For Lighting

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Web hosting

Table 12.

Custom Email

SiteBuilder

Utilization Factor for Typical Luminaires of the Five Classifications of Lighting


Systems
Ceiling

Luminaires Type

70%

Semi-direct
25 / 60
Maintenance Factor
Good.................0.75
Average............0.65
Poor..................0.55

General Direct

39 / 45

30%

Walls 50% 30% 10% 50% 30% 10% 30% 10%


Room
Index

Direct
0 / 79
Maintenance Factor
Good.................0.75
Average............0.65
Poor..................0.55

50%

Utilization Factors

J
I
H
G
F
E
D
C
B
A

0.37
0.45
0.49
0.53
0.56
0.61
0.66
0.67
0.71
0.72

0.31
0.41
0.45
0.49
0.53
0.58
0.63
0.65
0.68
0.70

0.27
0.37
0.42
0.46
0.49
0.53
0.60
0.62
0.66
0.67

0.36
0.45
0.49
0.53
0.55
0.60
0.64
0.66
0.69
0.71

0.31
0.40
0.45
0.49
0.52
0.57
0.62
0.64
0.67
0.68

0.27
0.37
0.42
0.46
0.49
0.55
0.60
0.62
0.65
0.67

0.31
0.40
0.45
0.48
0.51
0.56
0.61
0.63
0.66
0.67

0.27
0.37
0.42
0.46
0.49
0.55
0.60
0.61
0.64
0.66

J
I
H
G
F
E
D
C
B

0.27
0.35
0.37
0.43
0.46
0.50
0.55
0.58
0.62

0.25
0.29
0.34
0.38
0.41
0.46
0.50
0.53
0.57

0.19
0.26
0.30
0.34
0.37
0.42
0.46
0.49
0.53

0.26
0.33
0.36
0.40
0.43
0.47
0.51
0.53
0.57

0.22
0.28
0.32
0.36
0.39
0.43
0.47
0.49
0.53

0.16
0.25
0.29
0.32
0.35
0.40
0.44
0.46
0.51

0.20
0.27
0.30
0.33
0.37
0.40
0.44
0.46
0.50

0.18
0.24
0.28
0.31
0.33
0.38
0.42
0.44
0.48

0.64

0.60

0.56

0.59

0.55

0.52

0.51

0.49

J
I
H
G

0.24
0.29
0.33
0 37

0.19
0.25
0.28
0 32

0.16
0.22
0.26
0 29

0.22
0.27
0.30
0 33

0.18
0.23
0.26
0 29

0.15
0.20
0.24
0 26

0.16
0.21
0.24
0 26

0.14
0.19
0.21
0 24

Maintenance Factor
Good.................0.75
Average............0.65
Poor..................0.55

Semi-indirect
66 / 20
Maintenance Factor
Good.................0.75
Average............0.65
Poor..................0.55

Idirect
80 / 0
Maintenance Factor
Good.................0.75
Average............0.65
Poor..................0.55

G
F
E
D
C
B
A

0.37
0.40
0.45
0.48
0.51
0.55
0.57

0.32
0.36
0.40
0.43
0.46
0.50
0.53

0.29
0.31
0.36
0.39
0.42
0.47
0.49

0.33
0.36
0.40
0.43
0.45
0.49
0.51

0.29
0.32
0.36
0.39
0.41
0.45
0.47

0.26
0.29
0.33
0.36
0.38
0.42
0.44

0.26
0.29
0.32
0.34
0.37
0.40
0.41

0.24
0.26
0.29
0.33
0.34
0.38
0.40

J
I
H
G
F
E
D
C
B
A

0.20
0.24
0.28
0.31
0.34
0.38
0.42
0.45
0.49
0.51

0.16
0.20
0.24
0.27
0.30
0.34
0.38
0.41
0.45
0.47

0.13
0.18
0.21
0.24
0.27
0.31
0.35
0.37
0.42
0.44

0.16
0.20
0.23
0.26
0.28
0.31
0.34
0.36
0.39
0.41

0.13
0.17
0.19
0.22
0.24
0.27
0.30
0.32
0.36
0.38

0.11
0.15
0.17
0.20
0.22
0.25
0.28
0.30
0.34
0.36

0.10
0.13
0.15
0.17
0.19
0.21
0.23
0.25
0.27
0.28

0.09
0.12
0.13
0.15
0.17
0.19
0.22
0.23
0.25
0.27

J
I
H
G
F
E
D
C
B
A

0.15
0.19
0.22
0.26
0.28
0.32
0.35
0.38
0.42
0.43

0.11
0.15
0.19
0.22
0.24
0.28
0.31
0.34
0.39
0.41

0.10
0.13
0.16
0.19
0.21
0.25
0.29
0.31
0.36
0.38

0.09
0.12
0.14
0.17
0.19
0.21
0.23
0.25
0.27
0.29

0.08
0.10
0.12
0.14
0.16
0.18
0.21
0.22
0.25
0.27

0.06
0.09
0.10
0.13
0.14
0.17
0.19
0.21
0.24
0.25

0.04
0.06
0.07
0.08
0.09
0.11
0.12
0.13
0.15
0.16

0.03
0.04
0.05
0.07
0.08
0.10
0.11
0.12
0.14
0.15

Utilization Factor for Typical Luminaires of the Five Classifications of Lighting


Systems

we b hosting dom a in nam e s


we b de sign online ga m e s

You might also like