0% found this document useful (0 votes)
41 views

Triangular

The document describes how to build and test triangular and square wave generators using a 741 opamp. It lists the required components including a CRO, resistors, signal generator, oscilloscope probes, 741 opamp, capacitors, and multimeters. The design equations for the triangular wave amplitude and frequency are given. The procedure involves wiring the circuit, varying a 1K potentiometer to obtain the maximum output voltage, and applying a DC voltage to vary the square/triangular pulse width. Plots of the first and second stage outputs are to be recorded.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
41 views

Triangular

The document describes how to build and test triangular and square wave generators using a 741 opamp. It lists the required components including a CRO, resistors, signal generator, oscilloscope probes, 741 opamp, capacitors, and multimeters. The design equations for the triangular wave amplitude and frequency are given. The procedure involves wiring the circuit, varying a 1K potentiometer to obtain the maximum output voltage, and applying a DC voltage to vary the square/triangular pulse width. Plots of the first and second stage outputs are to be recorded.
Copyright
© Attribution Non-Commercial (BY-NC)
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 2

08.

408 Analog Integrated circuits Lab Manual Triangular wave generator and square wave generator using 741 opamp Aim: To test and generate a triangular wave generator and square wave generator using 741 opamp Components required : CRO (20Mhz ,dual channel) Resistors Signal generator Oscilloscope probes ua741 opamp, capacitors,multimeters

Design : Vtrp-p=2 R1/R2.Vsat fo=R2/4R1R3C1 f0'=fo(1-(Vref/Vsat)2) duty cycle T1/T=0.5(1-Vref/Vsat) Procedure :a)Wire up the circuit as in circuit b) Vary the 1K ohm pot to get maximum voltage output of the wave form (triangle or square). c) Apply a dc voltage to the non- inverting terminal of the second stage to vary the pulse Dept of ECE,VKCET

08.408 Analog Integrated circuits Lab Manual width of the square/triangular pulse. d) Plot the output of the first and second stages and record the result Result: The Vpp of the triangular wave and square wave generator using opamp is ..V and ..V The fo of the triangular wave is ...Hz and the duty cycle is = ..

Dept of ECE,VKCET

You might also like