Reference Manual: Next Generation FDU
Reference Manual: Next Generation FDU
PK3536_01_08
Next Generation Front Desk Unit
Reference Manual
First Edition
A publication of
KABA ILCO Inc.
7301 Decarie Blvd.
Montreal, Quebec,
Canada H4P 2G7
No part of this book may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying, recording, or by any information storage and retrieval system,
without prior written permission from the Publisher.
The information contained in this publication is accurate to the best of KABA ILCO Inc.’s knowledge.
PK3536_01_08
Next Generation FDU User Guide
Note:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
The user may find the following booklet prepared by the federal Communications Commission helpful:
'How to identify and Resolve Radio-TV interference Problems." This booklet is available from the
Government Printing Office, Washington, DC, 20402. Stock # 004-000-00345-4.
PK3536 01_08 1
Next Generation FDU User Guide
Table of Contents
Introduction 4
Keycards 5
PK3536 01_08 2
Next Generation FDU User Guide
Chapter 8: Programming 63
8.1 Lock Programming 63
8.2 Another FDU 71
PK3536 01_08 3
Next Generation FDU User Guide
Introduction
This Reference Manual outlines how to use the Next Generation Front Desk Unit
(FDU).
Guest Service Attendants at the front desk use the FDU primarily to encode
Guest keycards, while management can use the FDU to make staff (submaster)
keycards and to set system parameters.
Generation E-760 The Electronic 770 Solitaire 710-II The Contactless 790
The additional read-write features of the Contactless 790 (that do not apply to the
other lock models) are outlined in this manual. The associated Remote Access
Controllers (RACs) and Exit Device Operators are also referenced.
PK3536 01_08 4
Next Generation FDU User Guide
Keycards
The FDU can encode two types of keycards: magstripe or Mifare (ISO 14443)
keycards for the Contactless 790 lock.
Magstripe Keycards:
Available in Low or High Coervicity. High Coervicity keycards are slighty more
expensive but are less likely to demagnetize. No audit trail is memorized. Hotels
can have either Low or High Coervivity encoding, not both.
The following table outlines the different types of keycard that are available and
compatible with each lock and their usages.
Lock
Keycard Use
Compatibility
Contactless 790
Solitaire 710-II
Electronic 770
Keycard Type Action
FDU Lock
Guest Staff
Auth. Audit
or
Reset
Magstripe
Low Coercivity
Magstripe
High Coercivity
MIFARE Mini
(Guest)
MIFARE 1k
(Staff)
MIFARE 4k
(Audit)
PK3536 01_08 5
Next Generation FDU User Guide
(Note: When FDA or FDA PIN# is used, default menu is set to enter
room number for guest keycard.)
2. Press 1 to select “Guest Keycard” menu.
3. Press 1 to select “Guest” menu.
4. Enter room number 101 (example).
5. Other options can be changed such as Nights, Expiry Hour, New or
Duplicate Key, and any other options enabled in the FDU. Use the arrow
down <T> button to change selections.
6. When all options are set to encode the keycard, press < >.
7. Insert and swipe a blank guest keycard and/or present up to two cards at
a time to Contactless Encoder (for 790 locks)
8. Your Guest Keycard has now been created for room 101.
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 2 to select “Adjoining Suite” menu.
5. Enter Main room number 106 (example).
6. Use arrow down <T> to add other rooms.
PK3536 01_08 6
Next Generation FDU User Guide
7. Press the right <X> arrow to access the available rooms to be selected,
such as 107 and 108 (example).
8. When all the rooms have been chosen, press < >.
9. Other options can be changed such as Nights, Expiry Hour, New or
Duplicate Key, and any other options enabled in the FDU. Use the arrow
down <T> button to change selections.
10. When all options are set to encode the keycard, press < >.
11. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
12. Your Adjoining Suite keycard has now been created for rooms 106,107
and 108.
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 3 to select “Common Door Suite” menu.
5. Enter Main Suite number 250 (example).
6. Use arrow down <T> to add other suite rooms.
7. Press the right <X> arrow to access the available Suites to be selected,
such as 251, and 252, (example).
8. When all the suites have been chosen, press < >.
9. Other options can be changed such as Nights, Expiry Hour, New or
Duplicate Key, and any other options enabled in the FDU. Use the arrow
down <T> button to change selections.
10. When all options are set to encode the keycard. Press < >.
11. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
PK3536 01_08 7
Next Generation FDU User Guide
12. Your Common Door Suite keycard has now been created for rooms 250,
251, and 252.
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 4 to select “One Shot” menu.
5. Enter room number 101 (example) and press < >.
6. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
7. Your Guest One Shot keycard has now been created for room 101.
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 5 to select “One Shot” menu.
5. Enter Suite number 200 (example).
6. Other options can be changed such as Nights, Expiry Hour, New or
Duplicate Key, and any other options enabled in the FDU. Use the arrow
down <T> button to change selections.
7. When all options are set to encode the keycard, press < >.
PK3536 01_08 8
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 6 to select “Pre-Registered Guest” menu.
5. Enter room number 350 (example).
6. Press the right <X> arrow to access the Date menu when the Keycard
will be used in the lock. Note: Pre-Registered cards can be made up to
10 days in advance maximum. Press < > when Date has been chosen.
7. Other options can be changed such as, Expiry Hour, New or Duplicate
Key, and any other options enabled in the FDU. Use the arrow down
<T> button to change selections.
8. When all options are set to encode the keycard, press < >.
9. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
10. Your Pre-Registered Guest keycard has now been created for Room 350
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 1 to select “Guest Keycard” menu.
4. Press 7 to select “Pre-Registered Adjoining Suite” menu.
PK3536 01_08 9
Next Generation FDU User Guide
PK3536 01_08 10
Next Generation FDU User Guide
can be made up to 10 days in advance maximum. Press < > when Date
has been chosen.
10. Other options can be changed such as, Expiry Hour, New or Duplicate
Key, and any other options enabled in the FDU. Use the arrow down
<T> button to change selections.
11. When all options are set to encode the keycard, press < >.
12. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
13. Your Pre-Registered Common Door Suite keycard has now been created
for Rooms 574, 575, and 576.
PK3536 01_08 11
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 2 to select “Read/Verify.”
PK3536 01_08 12
Next Generation FDU User Guide
PK3536 01_08 13
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
5. FDU is now in PMS mode. FDU will display “Strike <X> to Quit Interface.”
2. Enter 2 to log off the current authorization without exiting the PMS
interface.
3. The FDU is still communicating with the PMS and is waiting for a valid
Authorization before Keycards can be encoded.
PK3536 01_08 14
Next Generation FDU User Guide
PK3536 01_08 15
Next Generation FDU User Guide
PK3536 01_08 16
Next Generation FDU User Guide
PK3536 01_08 17
Next Generation FDU User Guide
PK3536 01_08 18
Next Generation FDU User Guide
PK3536 01_08 19
Next Generation FDU User Guide
PK3536 01_08 20
Next Generation FDU User Guide
PK3536 01_08 21
Next Generation FDU User Guide
PK3536 01_08 22
Next Generation FDU User Guide
Used to create a lock audit keycard that will carry the audits from the lock back to
the FDU. See section 9.1.2 for more information.
This step is not for cancelling Grand Master or Emergency keycards if they have
been lost or misplaced, if this happens use the relevant Reset Keycards.
PK3536 01_08 23
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 5 to select “Reset Keycard” menu.
4. Press 1 to select “Reset Guest” menu.
5. Press 1 to select “Guest” menu.
6. Enter room number 101 (example).
7. Use the arrow down <T> button to change keycard quantity.
8. When quantity is set, press < > to encode keycard(s).
9. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
10. Your Reset Guest keycard has now been created for room 101.
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 5 to select “Reset Keycard” menu.
PK3536 01_08 24
Next Generation FDU User Guide
PK3536 01_08 25
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 5 to select “Reset Keycard” menu.
4. Press 4 to select “Reset One Shot” menu.
5. Enter room number 101 (example).
6. When options are set to encode the keycard, press < >.
7. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
8. Your Guest One Shot keycard has now been created for room 101.
5.1.5 Reset Convention Suite
1. Swipe or present a GMA authorized level keycard.
(Note: You cannot use FDA keycard or PIN to access this Function)
2. Press 5 to select “Reset Guest Keycard” menu.
3. Press 5 to select “Reset One Shot” menu.
4. Enter Suite number 200 (example).
5. When options are set to encode the keycard, press < >.
6. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
7. Your Reset Convention Suite keycard has now been created for Suite
200.
PK3536 01_08 26
Next Generation FDU User Guide
5. When options are set to encode the keycard, press < >.
6. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
7. Your Pre-Registered Guest keycard has now been created for Room 350
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 5 to select the “Reset Keycard” menu.
4. Press 2 to select the “Reset Passage” menu.
5. Press 1 to select the “Guest Room”.
6. Use the arrow down <T> button to select Room #.
7. Enter room number 101 (example).
8. Use the arrow down <T> button to change keycard quantity.
9. When quantity is set, press < > to encode keycard(s).
10. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
11. Your Reset Guest Passage keycard has now been created for room 101.
PK3536 01_08 27
Next Generation FDU User Guide
PK3536 01_08 28
Next Generation FDU User Guide
2. If the user level is FDA, press the < > key to reach the main screen.
3. Press 5 to select “Reset Keycard” menu.
4. Press 2 to select “Reset Passage” menu.
5. Press 4 to select “Restricted Area”.
6. Use the arrow down <T> button to select Restricted Area #.
7. Enter the area number 84 (example).
8. Use the arrow down <T> button to change keycard quantity.
9. When quantity is set, press < > to encode keycard(s).
10. Insert and swipe a blank keycard and/or present keycard to Contactless
Encoder (for 790 locks).
11. A Reset Passage Restricted Area #84 keycard has been created.
PK3536 01_08 29
Next Generation FDU User Guide
PK3536 01_08 30
Next Generation FDU User Guide
PK3536 01_08 31
Next Generation FDU User Guide
PK3536 01_08 32
Next Generation FDU User Guide
PK3536 01_08 33
Next Generation FDU User Guide
For hotels using 760, 770 or 710-II locks, standard magstripe keycards are used
for Submaster Keycards. For hotels using the Contactless 790, either 1K or 4K
Mifare keycards can be used. 1k keycards will record a staff movement audit trail
of 70 events and 4k keycards will record a staff movement audit trail of 300
events. Refer to the section “Staff Keycard Audit” (applicable only to the
Contactless 790) for the steps.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 1 to select “Submaster” menu.
4. Press 1 to select “Section.”
5. Enter section number 1 (example). Note: The number entered must be
pre-programmed into the lock(s) or the card will not work. Level Staff
range is from 1 to 255.
6. Use the arrow down <T> button to change New or Duplicate: (Note:
Select Duplicate if adding keycard to existing cards already in use.
Otherwise Select New to remake all cards.)
7. Use the arrow down <T> button to add Guest or Staff Common Areas if
active, and to enter keycard quantity.
PK3536 01_08 34
Next Generation FDU User Guide
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 1 to select “Submaster” menu.
4. Press 2 to select “Floor.”
5. Enter floor number 2 (example). Note: The number entered must be pre-
programmed into the lock(s) or the card will not work. Level Staff range is
from 1 to 255.
6. Use the arrow down <T> button to change New or Duplicate: (Note:
Select Duplicate if adding keycard to existing cards already in use.
Otherwise Select New to remake all cards.)
7. Use the arrow down <T> button to add Guest or Staff Common Areas if
active, and to enter keycard quantity.
8. When quantity is set, press < > to encode keycard(s).
9. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
10. Your Floor #2 keycard has now been created.
2. (Note: You cannot use FDA Keycard or PIN to access this Function)
PK3536 01_08 35
Next Generation FDU User Guide
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 1 to select “Submaster” menu.
4. Press 4 to select “Zone.”
5. Enter zone number 4 (example). Note: The number entered must be pre-
programmed into the lock(s) or the card will not work. Level Staff range is
from 1 to 255.
6. Use the arrow down <T> button to change New or Duplicate: (Note:
Select Duplicate if adding keycard to existing cards already in use.
Otherwise Select New to remake all cards.)
7. Use the arrow down <T> button to add Guest or Staff Common Areas if
active, and to enter keycard quantity.
8. When quantity is set, press < > to encode keycard(s).
PK3536 01_08 36
Next Generation FDU User Guide
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 1 to select “Submaster” menu and press 5 to select “Area.”
4. Enter zone number 5 (example). Note: The number entered must be pre-
programmed into the lock(s) or the card will not work. Level Staff range is
from 1 to 255.
5. Use the arrow down <T> button to change New or Duplicate: (Note:
Select Duplicate if adding keycard to existing cards already in use.
Otherwise Select New to remake all cards.)
6. Use the arrow down <T> button to add Guest or Staff Common Areas if
active, and to enter keycard quantity.
7. When quantity is set, press < > to encode keycard(s).
8. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
9. Your Area #5 keycard has now been created.
To create a PIN #, the FDU must be configured to allow this function. FDU
default is disabled (see section 7.3).
PK3536 01_08 37
Next Generation FDU User Guide
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 2 to select “FDU Authorization” menu.
4. Press the right <X> arrow to select “Front Desk.”
5. Use the arrow down <T> button to enter the Authorization #. (Each card
must be made separately and have individual # between 1-100.)
6. Enter authorization number 55 (example).
7. Use the arrow down <T> button to enable the Authorization PIN #. (This
will be displayed if PIN option is enabled.)
8. Use the arrow down <T> button to enter PIN# 1234 (example) (Each
card must have a separate PIN #). Press < >.
9. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
10. Your Front Desk Authorization #55 keycard has now been created.
11. The PIN# 1234 can replace the FDA #55 card to access the FDU.
To create a POS Keycard, the FDU must be configured to allow this function.
FDU default is disabled. Please see Chapter 7 FDU Setup
(Note: You cannot use FDA Keycard or PIN to access this Function)
PK3536 01_08 38
Next Generation FDU User Guide
10. Your POS Authorization #135 keycard has now been created.
11. The PIN# 3456 can replace the POS# 135 card to access the FDU.
12. The POS Authorization only gives access to the Read/Verify Function.
Although the POS Authorization uses the same numbers as other
Authorization Cards. Its use will not invalidate the other keycard or vice-
versa.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 2 to select “FDU Authorization” menu.
4. Press the right <X> arrow to select “Bellman’s.”
PK3536 01_08 39
Next Generation FDU User Guide
5. Use the arrow down <T> button to enter the Authorization #. (Each card
must be made separately and have individual # between 121-160)
6. Enter authorization number 121 (example). Press < >.
7. Use the arrow down <T> button to enable the Authorization PIN #. (This
will be displayed if PIN option is enabled.)
8. Use the arrow down <T> button to enter PIN# 5678 (example) (Each
card must have a separate PIN #). Press < >.
9. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
10. Your Bellman’s Authorization #121 keycard has now been created.
11. The PIN# 5678 can replace the BA# 121 card to access the FDU.
To create a PA Keycard, the FDU must be configured to allow this function. FDU
default is disabled. Please see Chapter 7 FDU Setup
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 2 to select “FDU Authorization” menu.
4. Press the right <X> arrow to select “Programming.”
5. Use the arrow down <T> button to enter the Authorization #. (Each card
must be made separately and have individual # between 101-120)
6. Enter authorization number 101 (example). Press < >.
7. Use the arrow down <T> button to enable the Authorization PIN #. (This
will be displayed if PIN option is enabled.)
8. Use the arrow down <T> button to enter PIN# 9012 (example) (Each
card must have a separate 4 digit PIN #). Press < >.
PK3536 01_08 40
Next Generation FDU User Guide
10. Your Programming Authorization #101 keycard has now been created.
11. Note: The PIN# 9012 can replace the BA# 101 card to access the FDU.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 2 to select “FDU Authorization” menu.
4. Press the right <X> arrow to select “Master.”
5. Use the arrow down <T> button to enter the Authorization #. (Each card
must be made separately and have individual # between 161-180.)
6. Enter authorization number 166 (example). Press < >.
7. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
8. Your Master Authorization #166 keycard has now been created.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 2 to select “FDU Authorization” menu.
PK3536 01_08 41
Next Generation FDU User Guide
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 3 to select “Restricted Area” menu.
4. Enter restricted number 100 (example). Note: The number entered must
be pre-programmed into the lock(s) or the card will not work. Restricted
Area range is from 1 to 200.
5. Use the arrow down <T> button to change New or Duplicate: (Note:
Select Duplicate if adding keycard to existing cards already in use.
Otherwise Select New to remake all cards.)
6. Use the arrow down <T> button to change keycard quantity.
7. When quantity is set, press < > to encode keycard(s).
8. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
9. Your Restricted Area #100 keycard has now been created.
PK3536 01_08 42
Next Generation FDU User Guide
Zones with this keycard, because the expiry should be set to the length of a shift
(or less) in the Expiry Menu.
(Note: You cannot use FDA Keycard or PIN to access this Function).
2. Press 6 to select “Staff Keycard” menu.
3. Press 4 to select “Bellman’s Master” menu.
4. Press the right <X> arrow to allow access to available Guest Common
Areas if option is enabled. Once Common areas are selected, press
< >.
5. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press the right <X> arrow to allow access to available Guest Common
Areas if option is enabled. Once Common areas are selected press < >.
3. Insert and swipe a blank guest keycard and/or present card to
Contactless Encoder (for 790 locks)
PK3536 01_08 43
Next Generation FDU User Guide
Lockout, Room Lockout or Hotel Lockout. The Grand Master keycard opens all
Common Area doors, but may be restricted to specific Time Zones.
Use of the Grand Master keycard should be tightly restricted since it can open
any room in the property and is usually set for a relatively long expiry.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 5 to select “Grand Master” menu.
4. Press the right <X> arrow to allow access to available Time Zones if
option is enabled. Once Time Zones are set, press < >
5. Use the arrow down <T> button to change keycard quantity.
6.6 Emergency
The Emergency keycard can open ANY door in ANY situation, if the lock is
working properly. The Emergency keycard overrides the deadbolt or privacy lock,
as well as the Room, Hotel and Salesman’s Lockouts.
Use of the Emergency keycard is usually restricted to the security staff and is
strictly controlled because a lost keycard can open any room in the property.
(Note: You cannot use FDA Keycard or PIN to access this Function)
2. Press 6 to select “Staff Keycard” menu.
3. Press 6 to select “Emergency” menu.
PK3536 01_08 44
Next Generation FDU User Guide
PK3536 01_08 45
Next Generation FDU User Guide
PK3536 01_08 46
Next Generation FDU User Guide
PK3536 01_08 47
Next Generation FDU User Guide
9. Adjoining Suite, Common Door Suite, One Shot and Convention Suite
Pre-register can be changed using same method. Use the arrow down
<T> button to change selections.
10. When all options are set, press < >.
11. Your Reset Guest keycard expiry selections have now been saved.
PK3536 01_08 48
Next Generation FDU User Guide
PK3536 01_08 49
Next Generation FDU User Guide
Options
1. Swipe an authorized GMA keycard.
For Contactless 790, present valid FDU Authorization Keycard to
external Contactless Encoder.
2. Press 7 to select “FDU Setup” menu.
PK3536 01_08 50
Next Generation FDU User Guide
PK3536 01_08 51
Next Generation FDU User Guide
PK3536 01_08 52
Next Generation FDU User Guide
PK3536 01_08 53
Next Generation FDU User Guide
10. When all options are set, press < >. Your selections have been saved.
Fixed Timezones
There are six fixed time zones that can be used to limit staff access to any lock in
the system, except for the RAC Model 3.5, 4 and 4XT Card Readers.
PK3536 01_08 54
Next Generation FDU User Guide
7.4.2 Timeouts
The time-out is the period of time between operations during which the Front
Desk Unit remains authorized, before returning to the main screen and requiring
the swipe of a new authorization keycard or PIN.
PK3536 01_08 55
Next Generation FDU User Guide
PK3536 01_08 56
Next Generation FDU User Guide
6. Press the right <X> arrow to change PA Level Enable. With this option
enabled, FDU can now make PA keycard. See: Staff Keycard Chapter 6.
7. Arrow down <T> to change POS. Press the right <X> arrow to adjust.
8. Arrow down <T> to change Accept PIN? Press the right <X> arrow to
adjust. Yes = FDA keycard can be replaced by entering PIN# into FDU.
See: Staff Keycard Chapter 6.
9. Arrow down <T> to change Create PIN? Press the right <X> arrow to
adjust. Yes = When making Authorization keycard, you can assign a
unique PIN# for the keycard being made. See: Staff Keycard Chapter 6.
10. Arrow down <T> to change Folio/Track 2 enable/disable. This is
available for FDU-B units only. When enabled Guest keycards (all types)
will have ability to create number to track …
11. When all options are set, press < >. Your selections have been saved.
5. Press the right <X> arrow to change Common Door Privacy Override.
Yes= with this function enabled, once Common Door lock is
programmed. If the lock has the deadbolt engaged, the guest keycard
will override the deadbolt. No= with function off, once lock is
programmed, if lock has deadbolt engaged, guest card will not gain
entry.
6. Arrow down <T> to Change Privacy Override. Press the right <X>
arrow to activate Yes / No Option.
7. Press the right <X> arrow to change Yes / No option. This function
enables the option to use Global Privacy Override Option.
8. Arrow down <T> to change Global Privacy Override. Press the right
<X> arrow to activate Yes / No Option.
PK3536 01_08 57
Next Generation FDU User Guide
10. Local time: should be 1 hour ahead with <star> after time. This would
mean unit is set for DST. DST begins 2nd Sunday @ 2am of March, ends
1st Sunday @ 2am of November.
11. When option is set, press < >. Your selections have been saved.
Guest, Staff and Passage keycards can be assigned to one of the Flexible Time
Zones that are programmed into the Model 3.5, 4 and 4XT RACs and the
Contactless 790 Lock.
Each Flexible Time Zone consists of four intervals that can be individually
selected. All keycards of the appropriate type (Guest, Staff or Passage) will be
valid during the intervals in the assigned Flexible Time Zone, and are not valid
(access denied) outside of those intervals. The Passage keycard swiped outside
the intervals will put the door in Passage mode at the proper time.
6. Arrow down <T> to change Times, press the right <X> arrow.
7. Type in Start Time 6:00a (example). Press the right <X> arrow to
change am/pm.
PK3536 01_08 58
Next Generation FDU User Guide
8. Arrow down <T> to change End Time type 10:00. Press the right <X>
arrow. Change to pm. When Start/End is set, press < >.
9. The FDU screen should now display the changes made for Timezone #1.
10. When all Timezones are set, press < >. Your selections have been
saved. (Note: Timezone settings are only used in Remote Access
Controller.)
PK3536 01_08 59
Next Generation FDU User Guide
An FDU can be configured to encode only magstripe keycards (for 700, 710,
760,770 and 710-11 locks) or Mifare (contactless) keycards for the Contactless
790 or both.
PK3536 01_08 60
Next Generation FDU User Guide
7.7 Volume
1. Swipe an authorized GMA keycard.
7.8 Contrast
1. Swipe an authorized GMA keycard.
PK3536 01_08 61
Next Generation FDU User Guide
5. Press < > to save the new contrast setting. (Note: Contrast can also be
adjusted without using keycard. Simply press arrow left or right at main
screen. Then press < > when done.)
PK3536 01_08 62
Next Generation FDU User Guide
Chapter 8 Programming
PK3536 01_08 63
Next Generation FDU User Guide
15. The lock is now programmed as Room 100 with Staff Section #1 access.
Note: This step should not be done if Backup Keycards have been preset in all
guest room doors.
PK3536 01_08 64
Next Generation FDU User Guide
6. Use the arrow down <T> button to select room number. Type in room #
151(example)
7. Use the arrow down <T> button to select Staff Submaster options.
8. When all options are set, press < >. FDU is ready to send new
configuration.
10. Connect the communication cable from the FDU, firmly onto lock and
press < > on the FDU. The following message is displayed:
PK3536 01_08 65
Next Generation FDU User Guide
PK3536 01_08 66
Next Generation FDU User Guide
5. Press the right <X> arrow to change Area Type Guest/Staff. Note: Only
one type of Common Area Guest or Staff can be chosen per lock.
6. Use the arrow down <T> button to select Area Number(s)
7. Press the right <X> arrow to add Guest/Staff Area #.
8. Press the right <X> arrow to change option Yes = Enabled, No =
Disabled.
9. When all options are set, press < >.
10. Guest Flex, Staff Flex, and Passage Flex Not available for Ilco Kaba
Lock.
11. Press < >. FDU display: FDU is ready to send new configuration.
12. Swipe a Programming keycard into lock (or present keycard to the
reader, for the Contactless 790). Solid Green L.E.D. will come on
activating program mode in lock.
13. Connect the communication cable from the FDU, firmly onto lock and
press < > on the FDU. The following message is displayed:
14. “Communication Successfully Completed. Press any key to continue.”
15. The Lock is now programmed as a Guest or Staff Common Area.
If this is a first time installation, insert the Initialization keycard in the RAC swipe
reader. The red and green L.E.D.’s should flash, then the green L.E.D. should
flash once more.
PK3536 01_08 67
Next Generation FDU User Guide
PK3536 01_08 68
Next Generation FDU User Guide
6. Use the arrow down <T> button to add Passage Flexible Timezone.
7. Note: Passage Flexible Timezone option is not available for regular
guest room doors. Only used for RAC unit; when Remote Access
Controller is programmed as restricted area this feature can be used.
Passage Flexible Timezones must be preset prior to selecting Timezone.
See Chapter 7 FDU setup.
8. When all options are set press < >. FDU is ready to send new
configuration.
9. Swipe a Programming keycard into lock (or present keycard to the
reader, for the Contactless 790). Solid Green L.E.D. will come on
activating program mode in lock.
10. Connect the communication cable from the FDU, firmly onto lock and
press < > on the FDU. The following message is displayed:
PK3536 01_08 69
Next Generation FDU User Guide
6. Connect the communication cable from the FDU, firmly onto lock and
press < > on the FDU. The following message is displayed:
PK3536 01_08 70
Next Generation FDU User Guide
7. “Trying to establish link with lock.” You will hear the motor engaging.
Cables required:
FDU G4 (blue screen) to FDU G4 (blue screen): Female-to-Female DB9 Null Modem.
FDU G4 (blue screen) to FDU G3 (green screen): Female-to-Female DB9 Null Modem.
10. “Trying to establish link with lock.” You will hear the motor engaging.
12. The lock is in override mode, simply use handle to open door.
PK3536 01_08 71
Next Generation FDU User Guide
PK3536 01_08 72
Next Generation FDU User Guide
PK3536 01_08 73
Next Generation FDU User Guide
PK3536 01_08 74
Next Generation FDU User Guide
PK3536 01_08 75
Next Generation FDU User Guide
19. When all options are set Press < >. FDU is ready to start the audit
report.
20. When viewing the audit on the FDU screen, use the <S> and <T> keys
to scroll through the list of entries. The first two screens will show
information about the lock itself. Followed by information of the lock
audit.
PK3536 01_08 76
Next Generation FDU User Guide
PK3536 01_08 77
Next Generation FDU User Guide
PK3536 01_08 78
Next Generation FDU User Guide
PK3536 01_08 79
Next Generation FDU User Guide
http://connect.kabalodging.com
The Technical Support Product Specialists operating our Emergency Hotline are
available 24/7
PK3536 01_08 80
Next Generation FDU User Guide
Swipe a Cleaning keycard through the Front Desk Unit 10 to 15 time once a
week.
Do not use chemical cleaners or abrasives, they will damage the finish.
The magnetic reader head should be cleaned every month. Simply insert and
withdraw a cleaning card several times in each lock. If your locks are exposed to
high levels of dust or salt, or are exterior they should be cleaned more often
(once a month).
PK3536 01_08 81
Next Generation FDU User Guide
1. Label the two Front Desk Units to differentiate the one that must receive
the data (new) from the one that must send the data (old or Master
FDU).
2. As a property may have previous versions of Kaba’s FDU system as well
as the new generation model different types of cables may be required
for the FDU to FDU transfer. If the version of FDU is unknown please
contact Kaba Technical Support.
Based on the table below, connect the required FDU to FDU communication
cable to the Serial Port on the rear panel of each Front Desk Unit.
3. On the FDU that will receive data, swipe a keycard having a GMA or MA
authorized user level.
For Contactless 790, present valid FDU Authorization Keycard to
external Contactless Encoder.
4. Press 8, or use the down <T> arrow followed by < > to reach the
“Programming FDU/Lock” menu.
5. Press 2, or use the down <T> arrow followed by < > to reach the
“Another FDU” menu.
6. Press 1, or use the down <T> arrow followed by < > for “Receive
Configuration” to put the receiving FDU in receive mode.
PK3536 01_08 82
Next Generation FDU User Guide
7. On the FDU that will transmit the data, swipe a keycard with a GMA or
MA authorized user level.
8. Press 8, or use the down <T> arrow followed by < > to reach the
“Programming FDU/Lock” menu.
9. Press 2, or use the down <T> arrow followed by < > to reach the
“Another FDU” menu.
10. Press 2, or use the down <T> arrow followed by < > for “Send
Configuration” to put the transmitting FDU into send mode.
After the data is transmitted, both FDU screens will give the following
message.
NOTE: The information shown above is when both FDUs are of the latest
generation model. An FDU to FDU transfer using one FDU of previous
generation will be slightly different. For any required support please
contact Kaba Technical Support.
PK3536 01_08 83
Kaba Lodging Systems
7301 Boul. Décarie Montréal (QC) H4P 2G7
Technical Support:
1.800.906.4526
Customer Service:
T: 1.877.468.3555
PK3536_01_08 Printed in Canada
F: 514.735.6589
General Information:
www.kabalodging.com
To access all of our easy steps, please visit our Support Website:
http://connect.kabalodging.com