This document provides sizing calculations for a proposed solar project in Spring Hope, FL. It lists derate factors used to calculate the overall DC to AC derate factor of 0.771. Solar panel specifications are provided for GE 185W panels, including dimensions, weight, and design voltage. NREL's PVWatts viewer estimates the monthly and annual AC energy output would be approximately 270 MWh if the solar array uses 1-axis tracking at a 35.9 degree tilt.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
70 views1 page
Solar Project
This document provides sizing calculations for a proposed solar project in Spring Hope, FL. It lists derate factors used to calculate the overall DC to AC derate factor of 0.771. Solar panel specifications are provided for GE 185W panels, including dimensions, weight, and design voltage. NREL's PVWatts viewer estimates the monthly and annual AC energy output would be approximately 270 MWh if the solar array uses 1-axis tracking at a 35.9 degree tilt.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Mills Engineering SPRING HOPE SOLAR Form xxx
1649 Smugglers Cove BASE CASE
Gulf Breeze, FL 32563 KJMills, PE 410 739-2127 SOLAR PROJECT SIZING Doc No… DERATE FACTOR Component Accepta SOLAR PANEL Derate Values Range Manufacturer GE PV module nameplate DC rating 0.95 0.80 - 1.05 Model Inverter and Transformer 0.97 0.88 - 0.98 Crystal Mismatch 0.98 0.97 - 0.995 Rating (watt) 185 Diodes and connections 0.995 0.99 - 0.997 Length 39.60 DC wiring 0.98 0.97 - 0.99 Width 25.70 Area (ft2) 7.1 AC wiring 0.99 0.98 - 0.993 Thickness (in.) 2.3 Soiling 0.95 0.30 - 0.995 Weight (lbs) lbs / ft2 roof load System availability 0.98 0.00 - 0.995 Design Fall-Off Voltage 13.2 Shading 1 0.00 - 1.00 Sun-tracking 0.95 0.95 - 1.00 Age 1 0.70 - 1.00 OVERALL DC to AC derate factor 0.771
NREL'ss PVWATTS VIEWER
NREL INVERTER SIZING 1 Axis Tracking Array Tilt 35.9 Solar AC Radiation Energy Month (kWh/m2/day) (kWh) Jan 4.08 19319 Feb 4.57 19376 Mar 5.63 25644 Apr 6.07 25980 May 5.95 25370 Jun 6.07 24706 Jul 5.61 23488 Aug 5.22 21939 Sep 5.61 23193 Oct 5.42 23874 Nov 4.33 19022 Dec 3.90 18080 Year 5.21 269991