0% found this document useful (0 votes)
55 views1 page

Calibration Tolerances

This document provides calibration tolerances and nominal loop resistance specifications for various thermocouple wire types including J, K, E, T, R, S, B, N, JX, KX, EX, TX, and NX. The calibration tolerances are specified for standard and special conditions within defined temperature ranges. The nominal loop resistances are provided in ohms per meter at 20°C for solid and flexible conductor wire with varying gauges and diameters.

Uploaded by

Samir Sabic
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
55 views1 page

Calibration Tolerances

This document provides calibration tolerances and nominal loop resistance specifications for various thermocouple wire types including J, K, E, T, R, S, B, N, JX, KX, EX, TX, and NX. The calibration tolerances are specified for standard and special conditions within defined temperature ranges. The nominal loop resistances are provided in ohms per meter at 20°C for solid and flexible conductor wire with varying gauges and diameters.

Uploaded by

Samir Sabic
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Quality System

TEMPERATURE CONTROLS PTY LTD


ACN: 650 190 183 ABN: 96 650 190 183
Quality

THERMOCOUPLE WIRE DATA SHEET


Endorsed
Company

SAI GLOBAL

Calibration Tolerances
ISO9001:2000
Lic 14412

Reference Junction 0°C


Calibration-Temperature Tolerances
Calibration Range (whichever is GREATER)
Type Type ature °C °C
Standard Special s GRE
THERMOCOUPLE-GRADE WIRE
J 0 to 750°C ±2.2°c or ±0.75% ±1.1°C or ±0.4%
K 0 to 1250°C ±2.2°C or ±0.75% ±1.1°C or ±0.4%
E 0 to 900°C ±1.7°C or ±0.5% ±1.0°C or ±0.4%
T 0 to 350°C ±1.0°C or ±0.75% ±0.5°C or ±0.4%
R or S 0 to 1450°C ±1.5°C or ±0.25% ±0.6°C or ±0.4%
B 870 to 1700°C ±0.5%
N 0 to 1250°C ±2.2°C or ±0.75% ±1.1°C or ±0.4%

Calibration- Temperature Tolerances


Calibration Range Tolerances
Type Type °C
°C StandardStandard Special
EXTENSION-GRADE WIRE
JX 0 to 200°C ±2.2°C ±1.1°C
KX 0 to 200°C ±2.2°C ±1.1°C
EX 0 to 200°C ±1.7°C ±1.0°C
TX 0 to 100°C ±1.0°C ±0.5°C
NX 0 to 200°C ±2.2°C ±1.1°C

NOMINAL LOOP RESISTANCE Ohms/Metre at 20°

CONDUCTOR Approx
KX EX JX TX NX Gauge
SOLID FLEXIBLE No.
AWG
NO. / SIZE MM
1/0.3 14.00 16.97 8.91 7.18 19.31
7/0.2 4.59 5.57 2.92 2.35 6.33
1/0.5 5.04 6.11 3.21 2.58 6.95 24
13/0.2 2.47 2.997 1.574 1.267 3.41
1/0.8 1.970 2.387 1.253 1.009 2.72 20
16/0.2 2.009 2.435 1.279 1.029 2.77
1/1.0 1.261 1.528 0.802 0.646 1.738 18
24/0.2 1.339 1.624 0.852 0.686 1.847
1/1.29 0.746 0.904 0.475 0.382 1.004 16