Load Demand For A Four Bedroom Two Bathroom Dwelling
Load Demand For A Four Bedroom Two Bathroom Dwelling
Load Demand For A Four Bedroom Two Bathroom Dwelling
Watt-hour of
essential(W) W) Usage(hr) Essential
load(Wh)
1-18.2cu. ft 300 8 2400
Refrigerator
1-TV 120 4 480
2-DVD 80 - -
1-Washing 500 - -
Machine
1-Laptop 30 3 90
Lighting 250 4 1000
1-Desktop PC 100 - -
1-Fan 20 6 120
1-Microwave 800 - -
1-Kettle 800 - -
1-Iron 800 1 800
1-Blender 350 - -
1-Component 60 - -
Set
1-CD Radio 30 - -
1-Air Dryer 1000 - -
Total 4890Wh
Load demand for a four bedroom two bathroom dwelling
Total Demand /day (Wh)
Total demand =
Efficiency
4890
=
0.695
= 7041.6Wh
7041.6
=
5
= 1408.32
Solar Array
Number of PV panels =
PV watt rating
1408.32
=
120
= 11.736 ≈ 12
= 1520 + 456
= 1976W
4890∗3
= 12.24
= 1198.53Ah
= 6.86 * 12 * 1.44
= 118.54A
Inverter Rating: 24V DC to AC 2300 Watt continuous power, 4600 watts peak power, Input
voltage range 20-30VDC
Installation Cost(JMD)
PV Panels $491904
Overhead cost $45000
Drawing and estimate $25000
Inverter, charge controller $35000
Roof and Wall $30000
Refurbishing
Battery Pack construction $50000
Protection system $25000
Total $701904
Table 2 – Installation cost
University of Technology
Energy Conservation
Lecturer: Mr. E. Gallimore
Assignment #3
Date: 24-3-11