This spreadsheet calculates the time required to purge pipes or tubes of different diameters based on the specified volume changes and flow rate. It provides purge times in seconds and minutes per foot for various pipe sizes ranging from 0.5 to 36 inches in diameter, based on 5 volume changes at a flow rate of 25 cubic feet per hour. The calculations are not affected by whether pipe diameter is specified as nominal pipe size or inner diameter.

Uploaded by

Mohamad Arraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
358 views1 page

Purge Time 7-00

This spreadsheet calculates the time required to purge pipes or tubes of different diameters based on the specified volume changes and flow rate. It provides purge times in seconds and minutes per foot for various pipe sizes ranging from 0.5 to 36 inches in diameter, based on 5 volume changes at a flow rate of 25 cubic feet per hour. The calculations are not affected by whether pipe diameter is specified as nominal pipe size or inner diameter.

Uploaded by

Mohamad Arraj
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 1

54382721.

xls

Pipe and Tube Purge Times


This spreadsheet calculates time for various pipe or tube sizes
based on the flow rate and volume changes specified

Use of pipe diameter as either NPS or ID is inconsequential


and does not affect the efficacy of the calculations

Volume Changes: 5
Flow Rate CFH: 25

Inside Diameter Purge time (s) Purge Time (min) Seconds Minutes
or NPS Seconds/foot Minutes/foot per 10 ft. (s) per 10 ft. (min.)

0.5 1 9.8
0.75 2 22.1
1 4 39.3
1.5 9 88.3 1.5
2 16 157.0 2.6
2.5 25 245.3 4.1
3 35 353.3 5.9
3.5 48 480.8 8.0
4 63 1.0 628.0 10.5
4.5 79 1.3 794.8 13.2
5 98 1.6 981.3 16.4
6 141 2.4 1413.0 23.6
8 251 4.2 2512.0 41.9
10 393 6.5
12 565 9.4
14 769 12.8
16 1005 16.7
18 1272 21.2
20 1570 26.2
24 2261 37.7
30 3533 58.9
36 5087 84.8

Basis: seconds will it take to purge 1 foot of pipe using 5 volume changes at 50 CFH
sec/ft= 5 * π * radius^2 (in^2) *(ft^3/1728 in^3)*(3600 s/hr)*(hr/50ft^3)*12 in/ft

5 X pi X radius^2 X 3600 X 12 reduces to 5 X pi X radius^2 X 3600


1728 X 50 144 X 50